Home
TB-6593 - Desco Industries Inc.
Contents
1. Selenoid for a amp Emergeny passing Home pos MS Turnstile Mechanism Tumming gt MS EDSUK reserves the right to make changes at any time without any notice All rights reserved Page 6 of 16 Copyright EDS Electrical Data Security Ltd The Service Provider www edsuk com Tel 0870 735 5050 Fax 0870 735 5533 e S EDSUKTHH28 Half Height Turnstile Operation and Maintenance Manual BM32 Turnstile control module Manufactured with reliable 8051 micro controller technology it has two main modes as operating and programming Operating mode can be programmed according to the list below Keypad Input output and mode keys are available on BM 32 card Programming mode or operating mode can be selected by the mode key Input and output keys provide entry and exit right while the turnstile is in Operating mode In programming mode it is used for adjustment of turnstile as indicated the table above K ir B1 Input Red Grey Red Blue Red Brown White Yellow Green White Yellow Green Pink Black Yellow Black Output Figure 3 BM32 Card Connectors Cable Colors and Keypad Operating Mode Input Output Required key combination for programming Press M and simultaneously press G or C until 0 Locked Locked input and output displays turn to red until LD14 and LD15 LEDs are turned off The following modes are written assuming that the operating mode of the turnst
2. e ON O H kl Figure 11 Mounting Drawing for EDSUKTHH28 EDSUKTHH28 Material List M10x85 Steel Anchor M10x20 Inbus Bolt M10 Washer 4 pieces 4 pieces 4 pieces EDSUKTHH28 Turnstile Maintenance Instructions 1 The clothing of the turnstile must be cleaned with wet rag 2 The connection screws of turnstile should be visually checked every 6 months 3 Turnstile arm connection must be visually checked NOTE Turnstile must have maintenance service by authorized service or distributors periodically In case it is not able to contact with an authorized service or dealer get into contact with producer firm and obtain information on periodical maintenance EDSUKTHH28 Electro mechanic Turnstile Turnstile Mechanism Solenoids __ fi2 months Control Cleaning oe e e gt jena _______omponents femos Control Lubrication Electronic Card Electrical Connections 12 months Indicator Cards 12 months Control Cleaning Electronic Cards 12 months Control EDSUK reserves the right to make changes at any time without any notice All rights reserved Page 14 of 16 Copyright EDS Electrical Data Security Ltd The Service Provider www edsuk com Tel 0870 735 5050 Fax 0870 735 5533 e S EDSUKTHH28 Half Height Turnstile Operation and Maintenance Manual Turnstile Troubleshooting Fault Reasons Solution Electricity is on the arms cannot be locked the displays are turned off and the tu
3. Employee Owned 5 The relay terminal will activate and unlock the Calibration turnstile if the defined tests are passed Pass through the turnstile The turnstile will re lock Frequency of recalibration should be based on the after one rotation critical nature of those ESD sensitive items handled and the risk of failure for the ESD protective equipment NOTE The turnstile will remain unlocked until either and materials In general EMIT recommends that the operator passes through or 15 seconds expire calibration be performed annually Use the EMIT 50424 Limit Comparator to perform periodic testing once every 6 12 months of the SmartLog V5 The Limit Comparator can be used on the shop floor within a few minutes virtually eliminating downtime verifying that the tester is operating within tolerances See TB 6581 for more information Figure 7 EMIT 50424 Limit Comparator EMIT 3651 Walnut Avenue Chino CA 91710 909 664 9980 Website DescoEMIT com TB 6593 Page 4 of 5 2015 DESCO INDUSTRIES INC Employee Owned Specifications SMARTLOG V5 WITH TURNSTILE SMARTLOG V5 TESTER Operating Voltage 220 VAC 50 60 Hz Operating Voltage 100 240 VAC 50 60 Hz Operating Temperature 0 to 40 C 32 F to 104 F Operating Temperature 32 F to 104 F 0 to 40 C Dimensions Crated 47 x 31 x 54 Dimensions 8 3 x 5 8 x 1 9 119cm x 78cm x 137cm 21 1cm x 14 7cm x 4 8cm Dimensions Uncrated See Figure 8 Weight 2
4. In T Mek A models Solenoids draw 300 mA continuous Constant current with 24 V supply In T Mek B models Solenoids draw 1500 mA continuous constant current with 24 V supply Counters 24 V Mechanic or Electronic Counter can be used Power Supply Model Mean Well trade mark 25 W 24V S 25 24 power supply is used On the right The Picture of the power supply EDSUK reserves the right to make changes at any time without any notice All rights reserved Page 12 of 16 Copyright EDS Electrical Data Security Ltd The Service Provider www edsuk com Tel 0870 735 5050 Fax 0870 735 5533 eds EDSUKTHH28 Half Height Turnstile Operation and Maintenance Manual Heating and Air Circulation Circuit For air circulation 90 90 fan is used It operates when the temperature of the turnstile heated over 35 C For heating 200 W heater is used When the internal temperature of turnstile is below 10 C it starts to operate automatically with fan The heating and air circulation circuits can be set by thermostat it can be set to different degrees depends on demand Fuse Protected by 2 A automatic fuse Turnstile Electrical Circuit Diagram omer BM32 ii Turnike Kontrol Karti Turnstile Mechanism Mikro Switchs Power Supply MEANWELL S 25 ran iren Parca o ooa o O ai wano fror forcen Sara f I isi
5. The turnstile is configured to Fail Safe Loss of Power Operation Should loss of power occur the turnstile s arms will unlock and rotate freely in both directions to allow operators to pass through The EMIT 50777 SmartLog V5 with Turnstile has an input voltage of 220 VAC ESD Association Information Compliance verification should be performed prior to each use daily shift change etc The accumulation of insulative materials may increase the foot grounder system resistance If foot grounders are worn outside the ESD protected area testing for functionality before reentry to the ESD protected area should be considered ESD SP9 2 APPENDIX B Foot Grounder Usage Guidance Process monitoring measurements shall be conducted in accordance with a Compliance Verification Plan that identifies the technical requirements to be verified the measurements limits and the frequency at which those verifications shall occur Compliance verification records shall be established and maintained to provide evidence of conformity to the technical requirements The test equipment selected shall be capable of making the measurements defined in the Compliance Verification Plan ANSI ESD 20 20 section 7 3 ANSI ESD 20 20 Table 1 Flooring Footwear Systems Technical Requirements Recommended Range less than 3 5 x 10 ohms measured per ANSI ESD STM 97 1 Typical test programs recommend that wrist straps that are used dail
6. at the turnstile s entrance Figure 5 Installing the Dual Independent Foot Plate 8 Complete the installation by establishing communication to the SmartLog V5 via the Ethernet cable See the Ethernet Setup procedure in TB 6584 for more information Operation NOTE The SmartLog V5 must first be programmed with the user ID table using the TEAM5 Software before being deployed for employee use or the default test settings will be applied See the TEAM5 User Manual for more information 1 Initiate the test procedure by identifying yourself to the SmartLog This may be done using the keypad barcode badge scanner or proximity badge reader if supplied Follow the prompt on the SmartLog s display 3 When performing a footwear test be sure to place both feet on the dual foot plate one foot per plate When performing a wrist strap test be sure to completely plug in the wrist cord into the tester s jack Press and hold the metal touch plate on the tester to perform the test Hold your finger on the touch plate until the results of the test are displayed If performing a wrist strap test and the wrist strap status LEDs do not illuminate verify that the wrist cord is correctly inserted into the tester Figure 6 Using the SmartLog V5 with Turnstile EMIT 3651 Walnut Avenue Chino CA 91710 909 664 9980 Website DescoEMIT com TB 6593 Page 3 of 5 2015 DESCO INDUSTRIES INC
7. enough to trigger the input EDSUK reserves the right to make changes at any time without any notice All rights reserved Page 9 of 16 Copyright EDS Electrical Data Security Ltd The Service Provider www edsuk com Tel 0870 735 5050 Fax 0870 735 5533 e S EDSUKTHH28 Half Height Turnstile Operation and Maintenance Manual Home and Turn Microswitch Inputs 5VDC r A 2 0 A i f Voci LD3 Ww j LD4 5 Py AN P34 a S a 4 x Z 9 lt 4K7 lt 4K7 P3 5 J11 1 TurnMs1 Microcontroller C gt tww 47 J11 2 TurnMs2 J12 1 HomeMs 1 e WAT J12 2 HomeMs 2 47 is e 100n 100n GND 4 ad e Figure 6 Home and Turn Microswitches Connection Equivalent Circuit NO contacts of the Microswitches on the mechanism are connected via BM 32 card s TurnMS and HomeMS inputs EDSUK reserves the right to make changes at any time without any notice All rights reserved Page 10 of 16 Copyright EDS Electrical Data Security Ltd The Service Provider www edsuk com Tel 0870 735 5050 Fax 0870 735 5533 e s EDSUKTHH28 Half Height Turnstile Operation and Maintenance Manual Passing Counter Audio and Indicator Control Outputs 24 VDC 22k 22k J4 1 Sound 5 VOC 4k7 4k7 J4 2 Sound L013 Y LD12 J4 3 Count a 4k7 4k7 4k7 4k7 F ji HA Count 2 Voci J J9 1 24 Pis PS ra e n Output P7 i indicator J9 2 In_Sig gt gt lt Merocontoller P 4k7 i
8. the mounting bracket by removing the 4 40 pan head screw located on the left hand side of the tester Open the turnstile s cover using the included keys Set the power switch located on the power box to the ON position Route the Ethernet cable through the turnstile and SmartLog bracket NOTE Cat5e cable is recommended for Ethernet wiring Cat6 cable may prove to be too rigid for most installations inside the SmartLog s mounting bracket Follow Figure 3 to learn where to connect the Ethernet cable on the SmartLog V5 Foot Plate Ethernet Figure 2 Connections to the SmartLog V5 right view cover off 5 Align the slots on the back of the SmartLog V5 with the hooks on the turnstile bracket Figure 3 Locating the mounting hooks on the bracket EMIT 3651 Walnut Avenue Chino CA 91710 909 664 9980 Website DescoEMIT com TB 6593 Page 2 of 5 2015 DESCO INDUSTRIES INC Employee Owned 6 Slide the SmartLog V5 into the bracket from the top to bottom Secure the SmartLog V5 to the bracket by fastening the 4 40 screw to the left side of the tester slide down ORT ere g the SmartLog V5 into the bracket and securing it into place with the 4 40 screw 7 Locate the foot plate cable at the base of the turnstile and connect it to the Dual Independent Foot Plate Place the foot plate at the base of the turnstile so operators can place their feet on it while performing tests
9. 0 Ibs 0 9 kg Weight Crated 257 Ibs 116 4 kg DUAL INDEPENDENT FOOT PLATE Weight Uncrated 135 Ibs 61 4 kg Dimensions e A E Weight 7 5 lbs 3 4 kg TURNSTILE CERTIFICATIONS e CE Certificates are available upon request to EMIT Customer Service 47 1 41 3 120 cm 105 cm ye a 11 0 28 cm Figure 8 Dimensions of the EMIT 50777 SmartLog V5 Turnstile Limited Warranty Warranty Exclusions Limit of Liability and RMA Request Instructions See EMIT s Warranty http emit descoindustries com Warranty aspx EMIT 3651 Walnut Avenue Chino CA 91710 909 664 9980 Website DescoEMIT com TB 6593 Page 5 of 5 2015 DESCO INDUSTRIES INC Employee Owned eds EDSUKTHH28 Half Height Turnstile Operation and Maintenance Manual EDSUKTHH28 Turnstile Operation and Maintenance Manual A EDSUK reserves the right to make changes at any time without any notice All rights reserved Page 1 of 16 Copyright EDS Electrical Data Security Ltd The Service Provider www edsuk com Tel 0870 735 5050 Fax 0870 735 5533 eds EDSUKTHH28 Half Height Turnstile Operation and Maintenance Manual Before You Start 3 EDSUKTHH28 Turnstile System Technical Specifications 5 Dimensions 6 Modules 6 EDSUKTHH28_A Turnstile Block Diagram 7 BM32 Turnstile control module 7 Keypad 7 Programming 8 Input and Output Ports 9 BM 29 Indicator Cards 12 Other Equipments 13 Turnstile Electrical Circuit Diagram 1
10. 3 EDSUKTHH28 Turnstile Mechanic Mounting Instructions 13 Mounting Drawing for EDSUKTHH28 13 EDSUKTHH28 Material List 13 EDSUKTHH28 Turnstile Maintenance Instructions 14 Turnstile Troubleshooting 14 EDSUK reserves the right to make changes at any time without any notice All rights reserved Page 2 of 16 Copyright EDS Electrical Data Security Ltd The Service Provider www edsuk com Tel 0870 735 5050 Fax 0870 735 5533 e S EDSUKTHH28 Half Height Turnstile Operation and Maintenance Manual Before You Start Thank you for purchasing EDSUKTHH28 Electro mechanic Turnstile Please carefully read the instructions contained in this manual and keep the manual for future references TURNSTILE SAFETY INSTRUCTIONS e It is recommended to read all safety and maintenance instructions before installing and using the turnstile e Read the manual before operating the turnstile e Do not open the turnstile due to safety precautions e Any repairs must be done by authorized services only Modifications made by user may result in danger for the turnstile and people e Do not operate damaged turnstiles and call an authorized service immediately e Comply with the power and voltage values specified in the technical specifications of turnstile e Comply with the operating temperature range specified in the technical specifications of turnstile e Check the power supply and control the card connections before re energizing the turnstile afterw
11. 33 module It is possible to command additional warning caution devices that can be mounted on Turnstile through 3 extra dry contact relays when used with BM33 module It is possible to use with all kinds of Access control units System Micro Controller was designed based on Modular structure Turnstile is a combination of the modules that fit for your requirements Thereby in comparison with complicated systems it eliminates the additional costs to be paid for the modules you do not require as well as avoiding the defects from the parts which do not belong to system and the extra power consumption used by them When used with PC if required it is possible to follow how many passes were made through the turnstile It was designed so as to operate bidirectional If required it can be transformed so as to operate bidirectional or to a free turnstile only with setting Emergency Mode When the power supply of the turnstile is cut passing becomes free in both directions When the free button is pressed passing becomes free in both directions In models with retractable arms when the panic button is pressed arms drop down automatically and passageway is opened entirely Passage Signs There are indicators with two colored lights on both sides at entry and exit Indicators On stand by state it indicates that the turnstile is ready with continuous green arrow Flashing green arrow in passing direction indicates free passing
12. EM IT TECHNICAL BULLETIN TB 6593 SmartLog V5 with Turnstile Installation Operation and Maintenance Figure 1 EMIT 50777 SmartLog V5 with Turnstile Description The EMIT 50777 SmartLog V5 with EDS EDSUKTHH28 Half Height Turnstile verifies the functionality of an operator s wrist strap and footwear and controls access to the ESD Protected Area The turnstile activates after the operator s wrist strap and or footwear is determined to act as a path to ground By touching the solid state switch once the SmartLog V5 independently tests the resistance path limits of both the wrist strap and ESD footwear in less than 2 seconds It may also test a worn ESD garment if it is used as part of personnel grounding path Test results are electronically stored in the SmartLog V5 and easily downloaded to a PC for logging records and evaluation This product can be used as one of the tools to fulfill the ANSI ESD 20 20 section 7 3 Compliance Verification Plan See TB 6584 for more information on the patented EMIT SmartLog V5 The EDS EDSUKTHH28 Half Height Turnstile is a bidirectional tripod swing turnstile Both its cabinet and tripod rotors are composed of stainless steel LED passage signs are located at both the entry and exit sides A flashing green arrow indicates when to pass and a red X indicates when the turnstile is closed Va D ais Made in the United States of America and Britain
13. afety instructions indicated above EDSUK reserves the right to make changes at any time without any notice All rights reserved Page 4 of 16 Copyright EDS Electrical Data Security Ltd The Service Provider www edsuk com Tel 0870 735 5050 Fax 0870 735 5533 e S EDSUKTHH28 Half Height Turnstile Operation and Maintenance Manual EDSUKTHH28 Turnstile System Technical Specifications Power 220 V AC or 24 V DC 30W Operating Voltage 24 V DC 20 Operating Temp 20 C 70 C Dimensions 280x950x1050 mm Weight 75 kg Body Features Waterproof body with 1 5mm 304 grade stainless steel Outdoor Use Turnstiles are designed for outdoor use Tripod Block With controlled tripod arms positioned with at 120 degrees Arms Polished stainless pipe 32x2mm Each arm can be demounted Tripod Lock It is locked with 24DC solenoids locks when the solenoids are pulled In emergency the system is shut down and turnstiles provide free passing in both directions Motion Control When the cycle starts to one direction the reverse is blocked and after a half turn the rest of the cycle is completed automatically and smoothly by a hydraulic shock absorber Optional Accessories Electronic control unit Remote unit Button unit Modular Platform Control It is commanded by TTL CMOS and Dry Contact for pass triggering Additionally it can be commanded by RS 232 RS422 and RS485 through PC with BM
14. and continuous red X sign in opposite direction indicates that passing though the opposite direction is opened and waiting is required An audio alarm indicates that passing is opened at the time of passing Audio alarm will accelerate and indicate lapse of time close to end of the time given for passing Quality System Manufacture process of our turnstiles is assured under ISO 9001 2000 quality system Compliance with relevant EN DIN and TSE standards are based on for all kinds of product used in production EDSUK reserves the right to make changes at any time without any notice All rights reserved Page 5 of 16 Copyright EDS Electrical Data Security Ltd The Service Provider www edsuk com Tel 0870 735 5050 Fax 0870 735 5533 e S EDSUKTHH28 Half Height Turnstile Operation and Maintenance Manual Dimensions 1050 mm Figure 1 Dimensions of EDSUKTHH28 Turnstile Modules 700 mm EDSUKTHH28 Turnstile Block Diagram Work station 220 VAC i Token Mechanism inputs BM33 RS 232 or RS 422 RS 485 gt Serial communication control card optional ry gt 24 V DC POWER SUPPLY pe Heating and ventilation circuit Figure 2 Turnstile Block Diagram BM32 Turnstile Control Card BM29 A Turnstile indicator card for input BM29 A Turnstile Indicator card for output gt gt Buzzer Pass Counter Token Counter v Selenoid For Input Selenoid For Output
15. ards any maintenance or damage e Use certificated spare parts and accessories approved by EDSUK e If any problem switch off the electrical connections of the turnstile and call EDSUK e During the cleaning and maintenance cut off the electrical connections Otherwise damage to the parts may result e Use wet rag for cleaning e Keep the turnstile away from over heated or fire environment Over heat may result in a damage to the turnstile e Do not use the turnstile in high magnetic areas e Do not expose the turnstile to excessive water in order to prevent any penetration EDSUK reserves the right to make changes at any time without any notice All rights reserved Page 3 of 16 Copyright EDS Electrical Data Security Ltd The Service Provider www edsuk com Tel 0870 735 5050 Fax 0870 735 5533 e S EDSUKTHH28 Half Height Turnstile Operation and Maintenance Manual TURNSTILE USAGE INSTRUCTIONS The turnstile is designed so as to allow one person to pass each time and more than one person mustn t try to pass at the same time In case of not functioning properly avoid actions that may result in damage to the turnstile In case of any malfunctioning and in order to avoid further damage T he system should be switched off and not used Substances harmful to turnstile mustn t be used for cleaning The manufacturer will not accept any responsibility for any inquiry or damage resulting from incompliance with the security and s
16. ctor J 2 provides 12 V supply voltage required for Token mechanism The Token was dropped signal which is produced by the mechanism is taken from this connector 12 VDC r I I 24 VDC 4 I I N Figure 4 Token Mechanism and Token Counter Connection Equivalent Circuit It produces one passing right to entry side signal in return for token was dropped signal and the signal required for increasing the value on the token counter by one level Avoid drawing current more than 0 mA instantly and 100 mA continuously from the J 3 2 J SA connector EDSUK reserves the right to make changes at any time without any notice All rights reserved Page 8 of 16 Copyright EDS Electrical Data Security Ltd The Service Provider www edsuk com Tel 0870 735 5050 Fax 0870 735 5533 e S EDSUKTHH28 Half Height Turnstile Operation and Maintenance Manual Free Authorize entry and Authorize exit Inputs 5 VDC Los y oz y Loe y Seale J a SLA Na See A a a a gt 4K7 4K7 gt 4K7 J5 3 Inp Vect 4 A IR NAA P 2 P30 J5 4 inp 47 J5 5 Out gt 2 WN e 3 pa J5 6 Out 47 DO ee 4 Microcontroller J5 1 Emg A 5 e AA e P3 2 J5 2 Emg 47 i ll 100n 100n 100n GNO 0 GND p e e e Figure 5 Input Output and Free Ports Equivalent Circuit As indicated in the diagram turning the ports to low position or to GND by dry contact is
17. ile is 0 1 Controlled Controlled M4G4G4C4C4M Passing Passing Controlled 2 Locked Passing M C C M 3 Controlled Locked M G G4M Passing 4 Fie Contones M G4C C HM Passing 5 Controlled Free M4G 4G 4C4M Passing 6 Locked Free M C M 7 Free Locked M G M 9 Free Free M G C M EDSUK reserves the right to make changes at any time without any notice All rights reserved Page 7 of 16 Copyright EDS Electrical Data Security Ltd The Service Provider www edsuk com Tel 0870 735 5050 Fax 0870 735 5533 e S EDSUKTHH28 Half Height Turnstile Operation and Maintenance Manual Programming For entering and exiting to programming mode Mode Key is used In Programming Mode e Entry key changes the passing right among Free Controlled passing and Locked respectively Exit key changes the passing right among Free Controlled passing and Locked respectively e In Free state indicator is green and no buzzer audio e Controlled Passing state indicator is green and buzzer alarms e In Locked state the indicator is red Use mode Key to exit from programming mode When not in programming mode Entry key gives entry right e Exit key gives exit right Input and Output Ports 24 VDC supply It connects via J 1 connector All voltage levels necessary for circuit is obtained from this source Token Signal and Token Counter Ports Token mechanism connects via J 2 conne
18. is J9 3 Gnd P2 Le a x lt 4k7 gt pala 4 eS r le J10 1 24 GND gt 1 Input J10 2 Out_Sig Indicator J10 3 Gnd Figure 7 Passing Counter Audio and Indicator Ports Equivalent Circuit Passing counter audio and indicators are open collector type outputs C iw Solenoid Control Outputs e a 5 VDC 22k 22k 22k e LD13 Y LD13 v L013 Y Ru RL2 RLS a a a A A A lt 4k7 4k7 4k7 2 T J6 1 Emergeny Pass Vect e mas J6 2 24V 5 e i J7 1 Selenoid Input pia z J7 2 24V Momncontoiior MELI Pua lt at 8 1 Selenoid Output J8 2 24V oo RL1 RL2 RL3 10 Figure 8 Solenoid Ports Equivalent Circuit Solenoid outputs are dry contact and normally in open relay type EDSUK reserves the right to make changes at any time without any notice All rights reserved Page 11 of 16 Copyright EDS Electrical Data Security Ltd The Service Provider www edsuk com Tel 0870 735 5050 Fax 0870 735 5533 eds EDSUKTHH28 Half Height Turnstile Operation and Maintenance Manual BM 29 Indicator Cards Connector includes 24 V Supply pin GND pin and Signal pin The green allow or red allow flashes according to the information coming from the Signal pin under power supply 24 VDC 4k7 B 24V WN 33K 150R a Green YW Red i x 80 R e Z o Figure 9 BM29 Equivalent Diagram Other Equipments Solenoids
19. n ree Cw ee ee a z SI 1250A_T2 Devre Semasi aa MAKIM Mo 1 F 05 Rev Tun hekieri Maime aittir Irinei copalt tenes Figure 10 Circuit Diagram EDSUKTHH28 Turnstile Mechanic Mounting Instructions 1 Select a proper location so as not to obstruct turnstile s operation 2 Check the structure of the ground of installation site to ensure the necessary stability requirements 3 Mark the hole places on the ground in which the turnstile will be mounted 4 Drill the marked mounting holes by 10 drill bit and clean the dust inside the hole by the help of the air 5 Fix the steel anchors to the drilled holes If the ground is not strong fix the steel anchors after using chemical soil mixture Wait 20 minutes for hardening of chemical soil mixture 6 Pass the power and data cables which are prepared before through the hole on mounting plate 7 Put the mounting plate on the steel anchors and after putting the washer and nuts fix the ground 8 After putting the turnstile on the fixed mounting frames screw the bolts connecting the turnstile and mounting plate to each other EDSUK reserves the right to make changes at any time without any notice All rights reserved Page 13 of 16 Copyright EDS Electrical Data Security Ltd The Service Provider www edsuk com Tel 0870 735 5050 Fax 0870 735 5533 e S EDSUKTHH28 Half Height Turnstile Operation and Maintenance Manual Mounting Drawing for EDSUKTHH28
20. or its cables may be unplugged 2 Lock pins could malfunction 3 The turnstile could be set to free Mode to operate in one direction 1 Replace the solenoid and check the cables 2 Set the turnstile to the wanted Mode EDSUK reserves the right to make changes at any time without any notice All rights reserved Page 16 of 16 Copyright EDS Electrical Data Security Ltd The Service Provider www edsuk com Tel 0870 735 5050 Fax 0870 735 5533
21. rnstile is functionless 1 Power supply may be off or broken 2 Electrical fuse could be blown out 1 Check whether the electrical cable is plugged in 2 Change power supply if needed After one pass the turnstile is not locked and it allows multiple passes 1 Direction sensor micro switches could be broken 2 Electronic card could be broken 1 Replace micro switches 2 Replace electronic card Although indicators and buzzer work the turnstile does not allow pass Electricity is on the arms are turning freely 1 There may be a cable preventing the solenoid to open 2 Electronic card could be broken 3 Solenoid could be broken or there may be connection defects 1 Solenoid could be broken or there may be connection defects 2 Electronic card could be broken 1 The problematic cable is fixed 2 Replace electronic card 3 Replace solenoid and also check the connections 1 Replace solenoid and also check the connections 2 Replace electronic card The turnstile does not send info after pass 1 Cycle sensor micro switches could be broken or there may be connection defects 2 There may be defects in the cable transferring data 3 Electronic card could be broken 1 Replace microswitches and check the connections 2 Ckeck the cables carrying data 3 Replace electronic card Turnstile arms are giving noise due to friction while turning The oil wi
22. thin the rotor wheels could be dirty or runs out Lubricate the rotor wheels In winter or summer turnstiles do not operate smoothly Due to the changes in temperature the damper oil may not work properly Choose the wanted calibration smoothness using the cap screw behind the dumper EDSUK reserves the right to make changes at any time without any notice All rights reserved Page 15 of 16 Copyright EDS Electrical Data Security Ltd The Service Provider www edsuk com Tel 0870 735 5050 Fax 0870 735 5533 e S EDSUKTHH28 Half Height Turnstile Operation and Maintenance Manual Arms remain crosswise after pass and they do not return to initial position 1 The spring in the mechanism may be loosen up 2 Hydraulic damper or its calibration may be at fault 1 The spring is adjusted or replaced 2 Hydraulic damper setting is adjusted with the help of the cap screw behind the dumper or replaced Although the pass signal is given the turnstile does not allow passing 1 There may be problems in the signal sender card reader remote control button or its connections 2 Electronic card could be broken 3 Solenoid could be broken 4 Lock pins could malfunction 1 Replace the signal sender and check the connections 2 Replace electronic card 3 Replace the solenoid The turnstile allows multiple passes continuously 1 Solenoid could be broken
23. y should be tested daily However if the products that are being produced are of such value that knowledge of a continuous reliable ground is needed and then continuous monitoring should be considered or even required ESD Handbook ESD TR 20 20 section 5 3 2 4 4 US Patents 6 078 875 and 6 809 522 EMIT 3651 Walnut Avenue Chino CA 91710 909 664 9980 Website DescoEMIT com TB 6593 Page 1 of 5 April 2015 2015 DESCO INDUSTRIES INC Employee Owned Packaging SmartLog V5 with Turnstile Wall Mounting Bracket Connection Cover Dual Independent Foot Plate Wall Mounting Anchors Wall Mounting Screws 10 x 1 1 2 Turnstile Keys Certificate of Calibration lt AD AO AD ee ee oe Installation Installing the Turnstile A 220 VAC power line and Ethernet line are needed at the installation location of every SmartLog V5 with Turnstile Be sure to route these lines to the installation site prior to anchoring your turnstile See the attached EDS Operation and Maintenance Manual for instructions on anchoring and wiring the turnstile Do not use the SmartLog V5 until the turnstile is properly anchored and wired Installing the SmartLog V5 to the Turnstile See TB 6584 to learn more about the features and components of the SmartLog V5 EMIT recommends making any adjustments to its clock or test configurations prior to deployment for operator use 1 Disconnect the SmartLog V5 tester from