Home

SPM Flex Presentation v11 3.12.2015

image

Contents

1. Facilities In the event something breaks quickly get it fixed and get back to work Easy and intuitive to use means people are more likely to use the equipment correctly or leverage advanced features Also training time is expensive It takes people away from their day jobs sometimes requires overtime to get done and has to be refreshed every few years How many people onsite will use the unit What do they get paid including overheads How long do they go between use For places where uptime money this is a huge deal They probably know what time is worth so how much of their process is impacted by an outage A minute or two can be the difference between finding a leak in time or evacuating a building And don t forget once a building has been evacuated it s not just the restart time you also have to deal with the old product that may need to be scraped What extra equipment do they have to keep in case of process changes and how often do they make them How much capital is required for spares How much time is spent qualifying or maintaining vendors All the main components are serviceable in under 5 min much faster than competitive products and most items except for the battery are serviceable by the end user which can avoid a lengthy return process to the OEM Do they keep extra units around for when one breaks and are they a drop in replacement What is their backup validation for their detection systems A
2. SPM Flex Advanced Capabilities Ready When You Are SPM Flex Overview Key Differentiators Detection Type Gases Detected Installation Type Flow System Ji gt 1 gt A Lj a a a a a B a 8 is D a Communications Operating Conditions Honeywell The newest ChemCassette tape based gas detector for low level toxics from Honeywell Analytics Building off the legacy of the original SPM the SPM Flex has been redesigned from the ground up to provide maximum safety and productivity for users e Highly Automated To Improve Safety Accuracy And Usability e Flexible Application And Rugged Design e Easy To Service And Backed By Honeywell Tape based with advanced self monitoring optics design Hydrides Mineral Acids Oxidizers Diisocyanates and More Fixed Or Portable With Same Base Unit Automatic flow control sample up to 100 ft Relays 4 20mA Ethernet Modbus TCP IP USB 0 C to 40 C 0 100 Non Condensing Humidity 1 Contact HA For Latest Gas List Availability 2 For Most Gases Applications Sample line requires additional hardware to remove moisture in high RH conditions where condensing may occur Dry conditions may require humidification Newest Member Of The Honeywell Gas Detection Family HONEYWELL CONFIDENTIAL Multiple Use Cases Honeywell Quick Start Up Ease Of Gas An Industry Leading Selection Of Installable A
3. Gas data is stored on the ChemCassette so you always have the latest information including gas curves and alarm levels no need to What is the risk of user error when trying for manual intervention to monitor for gas What is the value of a piece of equipment o Automating Calibration that s clear and easy to use Automatic Flow Control the SPM Flex optimizes the flow eliminating the need for a user to adjust it prior to use Self Monitoring Optics the optics system has been designed to automatically monitor output eliminating the need for calibration with a stain card Eliminating Potential Mistakes Keeping Users Safer HONEYWELL CONFIDENTIAL Easy To Use Interface loneywei 15 42 01 J E Intuitive Operation And Menus Gas summary Gas selection tables use abbreviation and gas name which reduces the likelihood of selecting the wrong gas Gas concentration bar gives clear status vs alarm levels Current gas H2S Hydrogen Sulfide Alarm 1 5 pam Common language menus a Disabled Universal green yellow red status indication LDL Disabled ill Instrument l Alarm 2 Concentration Monitor Inhibit nee mode ym Mute indicator Fult indicator Indicator Battery How much training does your current dia ba P Clock li equipment require z S 15 42 01 J Ad OORD 5 5 Menu Main menu How many diiterent users might need to 0 1 gt 3 ane access a piece of equipment O Reset alarms
4. 674561 1874 0112 Power Supplies SPMF PCON SPMF ECON SPMF CCON 1265 2014 0235 0095 102599 100440 Install Accessories SPMEF MBST SPMF MBREF Mounting Universal Power Supply no cord North America 120VAC Power Cord Australia Power Cord Great Britain Denmark Switzerland Europe Japan 100VAC 6 Power Cable with Weather proof connector 10 Ethernet Cable with Weather proof connector Communication SPM Flex side connector and 6 communication cable with Weather proof SPM Flex Optics Test Card Union fitting use to connect disposible end of Tubing 1 4 O D x 1 8 LD FEP for sample Tubing polypropylene 1 4 O D x 3 15 LO for standard Mounting Bracket for Fixed Unit Retro Fit Mounting Bracket for Fixed Unit compatible with original SPM Electrical Spares Mechanical Spares Consumables 126540070 126540074 1265 0153 126540321 126540511 1265 0167 0140 0013 126540413 126540422 126540182 1265 0163 SPMF DCET SPMF DCCO SPMF DCPO 1991 0147 780248 6 1134 710235 HONEYWELL CONFIDENTIAL Honeywell Main PCB User interface display PCB User interface ribbon cable RFID PCB RFID Hall Effect cable assembly Hall effect PCB 9 Cell Battery pack factory only Coin battery CR2302 Energizer Pump Optics and Gate motor assembly Tape advance stepper motor Clear door Replacement latch assembly for clear door Power switch USB cover Warning label for power switch USB
5. LCD Light Audible option 4 20mA Relays SD Memory Card 5 to 40C NEMA 4X 20 Gases Up to 60 day Up to 150 ft in 25 ft out Z Purge Option Yes SPM Flex Fase Of Use e Highly Automated To Reduce Training And Operator Workload Clear Status Indications e High Visibility Even Far Away Flexible Configuration e Same Base Fixed Or Portable Data Tracking Capability e Automatic Built In Data Logging Configurable e Software Enabled User Customization Durability e Purpose Built IP65 Rated Serviceability e Key Components In Under 5 Min Backed Up By Global Service Org HONEYWELL CONFIDENTIAL Honeywell CL1 e Most Functions Manual User Error Common e Small Monochrome Screen Light Tree Needed e Multiple Units Needed e SD Card e Factory Configuration Only e NEMA 4 Enclosure e Older Components Difficult To Source CL1 Certification Issues Page 2 Of the DOD CL1 Manual 0 F DECLARATION OF CONFORMITY DOD TECHNOLOGIES INC 740 McA miie DR Unit C Crystal Lake Mimis 60014 We declare under our sole responsibility that the product described as ChemLogic 1 CLI Complies with the requirements of the Directives Machinery Directive INITEC amended Low Voltage Directive 2005 95 80 Electromagnetic Compatibility Directive 2004108 EC Standards considered EN 12100 1 EN 12100 2 EN 0204 1 EN 61000 6 2 EN 61000 6 4 Date 12 3 2007 At 10 00 am Daniel
6. O Donnell Honeywell EN12100 1 EN12100 2 and EN 60204 1 are machinery standards for the Machinery Directive Gas detection equipment with primarily electric operation doesnt fall under this certification The standards considered don t show compliance with the Low Voltage Directive which is not legal EMC standards noted require no performance testing they are just generic industrial standards However EN 50270 which most companies follow for gas detection equipment requires performance testing HONEYWELL CONFIDENTIAL 34 SPM Flex Advantages Primary Advantage Honeywell Who cares Why What s It Worth Highly Automated Easy To Use Quick Start Up Flexible Application Port Fixed Indoors Outdoors Easy To Service Backed By HON Safety May go long periods of time without using the equipment so easy to use less room for mistakes safer Facilities People spend less time in training because its easy to learn Safety Respond faster to emergency address a small problem before it s a big problem Facilities Get back to producing product quicker Safety Lots of flexibility on how to keep people safe and locations covered no matter what changes are being made in a plant Facilities Qualify one supplier simplifies maintenance schedule less spares needed Safety Reputable vendor that stands behind their products and can always provide service or expertise
7. SD Card 5 to 35C No 20 Built In Cals 15 day No No 31 Fixed Competitors List Price Company Size Weight Display Alarm Comms Data Storage Op Temp Weatherproof Gases Tape Lengths Sample Distance Haz Areas Tape Saver 8 100 9 375 Honeywell 13 2 H x 7 2W x 6 41 Unit 9 1 lbs bracket 3 4 Ibs Full Color LCD LED 90 DB buzzer 4 20mA 3x Relays Modbus TCP IP Web Rolling 90 Days O to 40C Yes IP65 Rated 30 Gases Custom Lvis Up to 90 day Up to 100 ft total in out Not Currently Duty Cycle In Process Honeywell 7 500 DOD Technologies 12 5 H x 10 3W x 9 0D 30 lbs Backlit monochrome LCD Light Audible option 4 20mA Relays SD Memory Card 5 to 40C NEMA 4X 20 Gases Up to 60 day Up to 150 ft in 25 ft out Z Purge Option Yes HONEYWELL CONFIDENTIAL SPM Flex vs CL1 Key Specs SPM Flex List Price Company Size Weight Display Alarm Comms Data Storage Op Temp Weatherproof Gases Tape Lengths Sample Distance Haz Areas Tape Saver 32 8 100 9 375 Honeywell 13 2 H x 7 2W x 6 4T Unit 9 1 lbs bracket 3 4 lbs Full Color LCD LED 90 DB buzzer 4 20mA 3x Relays Modbus TCP IP Web Rolling 90 Days 0 to 40C Yes IP65 Rated 30 Gases Custom Lvls Up to 90 day Up to 100 ft total in out Not Currently Duty Cycle In Process CL1 DOD Technologies 12 5 x 10 3W x 9 0D 30 lbs Backlit monochrome
8. What are the advantages of the SPM Flex versus my current SPM or TLD A The SPM Flex has been designed from the ground up to be the most flexible user friendly portable detector for low level toxics available today The unit starts up quickly and all necessary operating information is stored on the ChemCassette no more ChemKey s or feeding of tapes so you can quickly respond to an alarm Additionally thanks to the intuitive user interface your employees can take advantage of its advanced capabilities no expertise required Q What are the advantages of the SPM Flex versus other competitor products A The SPM Flex has a number of features which set it apart from the competition Its crisp full color LCD display and LED status bar allow you to quickly see the condition of the unit even from a distance and that same information is available remotely via the built in web page access And while you re there export the up to 90 days of event history which is stored via the units on board memory Q Is it a fixed or a portable unit A Both The SPM Flex shines as a portable unit but with up to 90 day tapes and the ability to hardwire communications and power connections it also performs well as a fixed or semi fixed unit which means less training and fewer spare parts And every unit comes with a battery so even if you lose power you re still protected Honeywell Q Is there any calibration required A Th
9. is 1265 4012 1265 3012 The low level HF tapes 1265 4001 1265 3001 do require a license and follow the normal approval process Q Does it have Duty Cycle Currently no but that is a popular option on the legacy SPM so we re looking at providing that as a future software upgrade Note that unreleased functionality cannot be guaranteed Honeywell Q Can use my old optics card No the stain color is different as is the shape and depth of this card This is a new optics block using a new LED and therefore requires a new card to test That said optics verification is not required so there isn t a reason why a user would ever need a card it s for piece of mind and old habits only Q Why don t need to do optics verification The SPM Flex uses a closed loop optics verification system meaning a reference diode measures the intensity of the LED and takes into account as well as corrects any shifts that may naturally occur as the LED ages This is part of the automation built into the SPM Flex that keeps users safer and improve accuracy HONEYWELL CONFIDENTIAL
10. 550 ppm 5ppm pf ppm 25 ppm ppm 0 ax Ca 1255 1265 NS NIC AS 0 6 Ea b 5ppb STEL pS crop 05200 ppb Se eet Hydrazine MH 3 1000 ppb 10 ppb 5ppb Sppb 10 ppb 130 3 15 00 RH Monomethy GN Dimethyl Hydra Under Development Expected April 2015 zine CHAN i O EEE pe p ee ee Sls MEMES Sm Ozone O 10 1000 ppb 100 ppb 50 ppb E nofilter FlexCC Ozone Or 125 3p 15 90 FH Hydrogen Peroxide H 0 Under Development See ee March 2015 Gas List Detection Levels Subject To Change Check With Product Management For Latest Release Schedule Industry Leading Gas Selection 15 HONEYWELL CONFIDENTIAL Honeywell Ordering HONEYWELL CONFIDENTIAL How To Order Fixed Portable Optional Accessories SPMF F TAU SPMF F1CH SPMF F1DK SPMF FIEU SPMF F1GB SPMF F1JP SPMF F1US SPMF P1AU SPMF P1CH SPMF P1DK SPMF P1EU SPMF P1GB SPMF P1JP SPMF P1US SPMF WAND SPMF STRP SPMF ANDL SPMF WTHR SPM Flex Fixed Unit for Australia OPM Flex Fixed Unit for Switzerland SPM Flex Fixed Unit for Denmark SPM Flex Fixed Unit for Europe SPM Flex Fixed Unit for Great Britain SPM Flex Fixed Unit for Japan SPM Flex Fixed Unit for North America SPM Flex Portable Unit for Australia SPM Flex Portable Unit for Switzerland SPM Flex Portable Unit for Denmark SPM Flex Portable Unit for Europe SPM Flex Portable Unit for Great Britain SPM Flex Portable Unit for Japan SPM Flex Por
11. Edition and EN 62133 2003 No certifications N A N A N A N A X N A N A N A N A N A N A N A N A Lead Acid Lead Acid Lead Acid No Bat By Far The Most Comprehensive Set Of Certifications 36 for most gases HONEYWELL CONFIDENTIAL DRAFT NOT FOR RELEASE 37 Likely Objections The Flex has been designed to be highly ergonomic and the portable version comes standard with a shoulder strap Its slightly heavier than the TLD but much lighter than the SPM No Try arm curls We sell those too That said sometimes there s no substitute for paper tape due to cross sensitivities physical evidence or LDL s Does your EC sensor get to the Arsine LDL It s required to protect the unit and in the event of a power loss ensures the unit reboots I m sure you have backup power systems but do they always work seamlessly We addressed a lot of challenges with this unit some of which took longer than expected to address The SPM Flex is the worlds most advanced single point tape based gas detector when you consider the value it provides we think the unit speaks for itself It s fixed Take the battery out and lower the price You ve been promising this for 2 yrs It s A Lot Of Money For A Portable Based on early feedback from customers Note that the semi sarcastic tone of some answers is for reading amuseme
12. NTIAL Built In Data Logging Honeywell 15 42 01 Standard Automatic Data Logging Event list l The SPM Flex stores up to 3 months of event history O XX XX ppm YYYY MM DD 00 00 00 Alarms Gas Concentrations and Configuration Changes along with corresponding date and time information are a XX XX ppm YYYY MM DD 00 00 00 l i all saved for review later CA oo IB bois e olin Easily export the history for analysis or archiving via the USB port or download it from the built in webpage CA 000 YYYY MM DD 00 00 00 D n record of vents l o you need a record of gas events Zero concentration readings are recorded every 15 seconds Would it be helpful to know what changes were made and when With gas present recordings are made every 1 second Note that due to the increased record frequency during gas events the amount of prior history that can be stored is Shortened Is data easy to extract from your current unit or even available Data Logging Ensures You Always Know What Happened HONEYWELL CONFIDENTIAL Multiple Security Levels 7 ri o User login L t Please enter your password Access Rights a amp v 2 Advanced Maintneanc o o mu o dl mu 4h o a O Not Logged In 5 Factory Service Can multiple personal access the unit Are you sure that everyone working with a piece of equipment know how to use it Security Levels Help Protect
13. Questions Q What ChemCassettes are available A Honeywell Analytics is proud to offer a wide range of detectable gases on ChemCassettes at launch in both two week thirty day and ninety day configurations At launch You can expect our full range of typical semiconductor gases including Hydrides Mineral Acids Oxidizers and Amines We re also pleased to offer popular Industrial gases such as Phosgene and if you don t see a gas you re looking for be sure to check with us as we continue to roll out new calibrations Q What maintenance is required A Periodic preventative maintenance is strongly recommended in order to keep the SPM Flex running smoothly Activities include replacing filters checking for system leaks and verifying optics and other mechanical elements are working as expected all of which are easily performed by the user Refer to the manual for a detailed service schedule Q What is serviceable by the end user A Most of the critical components in the SPM Flex have been designed to be user serviceable in under five minutes including the pump filters stepper motor and gate motor Notable exceptions include the battery and the main PCB board which should be serviced by Honeywell Analytics However one thing you ll never have to send the unit back for is updating the software just download it from our website and update it via the USB Refer to the manual for detailed service information Users s
14. Unauthorized Or Unsafe Access 10 HONEYWELL CONFIDENTIAL Honeywell j Rugged Design e Designed With The User In Mind The SPM Flex is ergonomically designed to be easy to carry and the display faces up so it s easy to read even if you have it suspended by the shoulder strap Wearing industrial gloves The monitor has large easy to use buttons even with protective equipment on Hazmat suit obscuring your vision The large color display and status bar means you ll always be able to see what s going on Is it hard to turn small knobs or press small buttons in hazmat gear e Stands Up To Harsh Conditions Are challenging environmental Need to install the SPM Flex outside No problem conditions hard on your equipment Thanks to it s fully weatherproof case it s ready to go Is your current equipment Clean room Exposed to toxic gas or caustic liquid Just hose it down 2 ES Ear The SPM Flex has a Teflon coating that doesn t attract dust so it s cleanroom and decontamination wipe safe Asturdy design means the SPM Flex is ready for years of hard use with uncompromising accuracy Purpose Built For The Users We Serve Note The SPM Flex is designed for use in temperatures 0 to 40 C and non condensing humidity of 0 to 100 although the pe sample line may require additional hardware to add remove moisture Refer to the manual for more information Easily Serviceable Honeywell e Designed With Ser
15. ame Base Kit Does supporting different fleets for fixed vs portable use Fixed Configuration force you to stock more spare parts i Foo J Include Standard Wall Mounting Bracket imp Battery Power Supply Regional Power Cord CD Quick Start Guide Increase training requirements Make it harder to track maintenance te Ld Optional Accessory Weather Shield m m s Flexible Configura tions Lowers Cost Of Ownership HONEYWELL CONFIDENTIAL Fully Configurable Honeywell 15 42 01 MA J Customizable Across Wide Range Of Options Configuration Manager set up l General Power Up Defaults Unit ID s Software Updates Please select what type of setting s you would like to load Alarms LDL Alarm 1 amp 2 Set Points Non Latching Communications 4 20mA Min Max Values Normal Relay state Ethernet Modbus TCP Options a Gas Related E Non Gas realted TWA Mode Fixed Start Or Floating Duration Security Outputs Screen Brightness Alarm Volumes Is it easy to update your equipment for Rapid Configuration Deployment new standards Configure Copy Config Deploy To Are site specific monitoring standards One Unit To USB Entire Fleet hard to enforce How much time does it take to deploy equipment configurations across your fleet Quick And Easy To Update Software And Configuration HONEYWELL CONFIDE
16. anks to the RFID enabled ChemCassette all necessary calibration information is updated automatically including flow control and default alarm set points so all you have to do is choose the right ChemCassette pick the gas you want from the on screen menu and go Q What are the operating parameters A The SPM Flex is a rugged purpose built piece of equipment Its weatherproof design IP 65 rated means it s well equipped to withstand changes in temperature and moisture and thanks to its Teflon coating it doesn t attract dust so it s cleanroom safe And if it s ever exposed to toxic gas or caustic liquid just hose it down or use a decontamination wipe Operating temperature ranges from 0 40 C 32 104 F which is largely limited by the ChemCassette technology Note that ChemCassette tapes should be stored at less than 0 C 32 F when not in use and are typically shipped with a shelf life of approximately 12 months Q Can set custom configurations A The SPM Flex is highly customizable including up to four levels of user access rights giving administrators unparalleled control Users can also set individual gas parameters for settings such as LDL and Alarm Levels 1 and 2 Once you have those configurations set quickly deploy them across multiple units using the USB For elevations in excess of 3 000ft above sea level some adjustments may be required HONEYWELL CONFIDENTIAL 26 Frequently Asked
17. cover Clear door gasket Dust cover For Ethernet port SPMF DCET Dust cover For Comm port SPMF DCCO Dust cover For power port Corrosive end of line filter Standard end of line filter Small acid scrubber f filter Standard size acid scrubber filter Portable Accessories Mal Sample Wand Kit SPMF WAND For use with portable units the sample wand kit enables users to pinpoint pesky leaks and the integrated holder within the handle provides a convenient way to install inline filters Cleanroom Suitable Strap SPMF STRP Made from cleanroom suitable materials the SPM Flex STRAP is a great way to transport the unit Note that the handle accessory is required SPMF HNDL due to the connection points required HONEYWELL CONFIDENTIAL 20 Fixed Accessories Mounting Bracket SPMF MBST or SPMF MBRF Need to mount the SPM Flex to the wall No problem The standard mounting bracket fits nicely behind the unit and the key hole design means the unit can easily be slid off the wall for maintenance or to go check for a leak Already have a legacy SPM We can handle that too The retrofit bracket SPMF MBRF will work in the existing holes y i ta e a HONEYWELL CONFIDENTIAL Honeywell Weather Shield SPMF WTHR Installing your unit outdoors While the unit is IP 65 rated we highly recommend protecting it from the sun and rain Wecan provide a custom weather shield which will help ensure
18. e a delivery date or even with certainty that we will do it Likewise no guarantees of backwards compatibility should be made All that said we see this as very do able Q Is it approved for hazardous areas A Not at this time The SPM Flex has not been designed for potentially explosive environments are another matter Currently this isn t something we ve incorporated into the design This is also something we re looking at for future and have reason to believe it could be done with some reasonable alterations to the unit However we have questions as to the viability of this market so at this time we re really just in the VOC phases HONEYWELL CONFIDENTIAL 41 More Frequently Asked Questions Q Can use a competitor s paper tape A The SPM Flex is purpose built for life safety gas detection and is specifically designed to work with genuine ChemCassette tapes Honeywell Analytics takes our responsibility for protecting the lives of workers very seriously and as such we strongly object to the use of imitation tapes in any of our products as we cannot and will not guarantee the performance of the device if used And it wouldn t work anyway The SPM Flex is the first product specifically built with an encrypted RFID to ensure a genuine ChemCassette is always used Q What is the lead time Our supply chain team is closely monitoring lead times during the first few months after launch Longer t
19. emCassette identification At this time it is not class 1 div 2 certified and should not be used in potentially explosive environments HONEYWELL CONFIDENTIAL Honeywell Internal Honeywell Use Only Product Comparisons SPM Flex Key Feature Updates Flow Control i Optics Verification Software Update Gas Information User Customization Start Up o Serviceability o Weight 28 Manual Set At Factory Calibration With Optics Card Return To Honeywell 2 4 weeks Tape Separate ChemKey Required Limited New ChemKey Required Highly Manual Multiple Parts Training Required Rats Nest Old Hard To Source Components Up To 30 Pounds SPM TLD HONEYWELL CONFIDENTIAL Honeywell Automatic Optimized To Tape Self Monitoring Never Needs Calibration Download Via The Web 5 min Stored On Cartridge With RFID Full Customization Via Software Highly Automated Up And Running In Under 2 Min Modular Key Components Serviceable In Under 5 Min Approximately 10 Pounds SPM Flex SPM Flex Customer Value Drivers Honeywell a ee pal idad rie SPM Flex Competitors Speed Of Response 9 Up And Running In Under 5 Min e As Much As 30 Minutes Ease Of Use o Os anata mane toe Clear Status Indications Ss 9 High Visibility Even Far Away Small Monochrome Screen Flexible Configuration Ss Ss e Same Base Fixed Or Portable e Multiple Units Needed Data Tracking Capabil
20. erm we expect lead times to be consistent with legacy SPMs or TLDs We will be closely monitoring and communicating lead times For large orders exceptional demand please communicate with the team prior to committing to a date Q Why doesn t it come with a ChemCassette Is the first ChemCassette free No a ChemCassette must be purchased in addition to the unit Due to the wide variety of ChemCassettes offered we felt that this was the easiest option for our customers TBD While the first ChemCassette is not free there will be a product registration card with the unit We will send a voucher via email for a free 15 day ChemCassette to any customers who register their units online Honeywell Q Is there any start up required No the SPM Flex is designed to work straight out of the box In fact if you re using it as a portable you should be up and running in a matter of a few minutes Q Is the battery serviceable No due to regulations regarding the battery it is not serviceable by the end user or even Honeywell Field Service Engineers For units which require a replacement battery they must be returned to the factory Q When do I have to send it to the factory Rarely Most components are easily serviceable in 5 min and if you have a relatively clean environment it s unlikely you would need to send it in for cleaning The top three items most likely to require you to return a unit to the factory for ser
21. faults H2S Hydrogen Sulfide 0 Monitor mode 0 Change Chemcassette Q In monitor Bar graph Gas name Units w upper lower Highlighted Scroll bar Gas concentration alarm limits option Monitor mode indicator Advanced Capabilities No Expertise Required HONEYWELL CONFIDENTIAL Clear Status Indications Local LCD The crisp full color LCD display is easy to read and interpret clearly fee showing gas concentration and other H25 Hydrogen Sulfide data no matter what the conditions Instrument Fault BAD HAUG ee ed rente 0 123 LED Status Bar Thanks to the color coded LED bar on top of the SPM Flex you can see alarm status even from across the factory floor Is your current device easy to read Does it have clear notifications for faults and warnings Web Page Access Know what your units is doing in real time even if you re remote with full webpage access built right in and even download event history and other details Can you access it from anywhere or reset acknowledge faults and alarms How much time ts wasted looking for the point of gas detection with an issue HONEYWELL CONFIDENTIAL Flexible Configuration someywen UR e Portable Configuration Includes Handle Assembly Clean Room Suitable Shoulder Strap Battery Power Supply Regional Power Cord CD Quick Start Guide Optional Accessory Sample Wand Kit S
22. hould contact a qualified electrician for details and to ensure any installation complies with local regulations Honeywell Q What type of battery is included A The SPM Flex comes standard with a lithium ion battery pack that provides continuous operation of up to 12 hours depending on sampling conditions and unit configuration and takes approximately 4 hours to charge The battery is estimated to have approximately 4 hours of life at full charge after 1000 cycles Q What are the power requirements A The SPM Flex comes standard with an external power supply that can be plugged into a standard wall outlet and features a fully weatherproof connector For fixed applications a 1 conduit connection can be used to supply power Q What communication protocols are available A The SPM Flex comes standard with a wide range of communication protocols for integration into building management systems including Modbus TCP over Ethernet 4 20mA and relays 3x fault alarm and user configurable Additionally the USB port can be used to extract event history configure device settings and even update the software Q What certifications are available A As a global product the SPM Flex was tested and certified for use by UL to applicable USA Canadian and European LVD and EMC requirements for safety in non hazardous locations It was also tested by UL for applicable FCC IC and NOB requirements for the radio frequency Ch
23. ity 9 Built In Data Logging Some Capability Via SD Card Highly Configurable O ee ee User Factory Configuration Only Rugged Durable 9 Purpose Built IP65 Rated rea aoa Easy To Service 9s Ss Key Components In Under 5 Min i ri Difficult SPM Flex CLPX CL1 Critical High Value Helpful But Not Mandatory bs y E 3 E l Low Impact Value o o _ HONEYWELL CONFIDENTIAL 30 Portable Competitors Specs List Price Company Size Weight Display Alarm Comms Data Storage Op Temp Weatherproof Gases Tape Lengths Haz Areas Tape Saver 8 100 9 375 Honeywell 13 21 x 7 2W x 6 4T 10 5 lbs with handle Full Color LCD LED 90 DB buzzer 4 20mA 3x Relays Modbus TCP IP Web Rolling 90 Days 0 to 40C Yes IP65 Rated 30 Gases Custom Lvls Up to 90 day Not Currently Duty Cycle In Process for most gases 5 000 Honeywell TLD 8 x8 x 9 TLD 9lbs Single Line LCD Light Audible 2x Relays External via 4 20mA 0 to 40C No 30 Gases 50 CKs 15 day No no 6 900 Honeywell SPM 12 x12 x 8 SPM Up to 25lbs Single Line LCD Light Audible RS422 3x Relays External via 4 20mA 0 to 40C NEMA 4X Enclosure 30 50 CKs Up to 90 day Z purge option Yes Option HONEYWELL CONFIDENTIAL Honeywell 6 700 DOD Technologies 11 0 L x 4 0W x 8 5T 6 lbs Backlit Monochrome 85db buzzer None Micro
24. nt only and NOT an endorsement of how we actually suggest responding to customers but every response here is true The CLPX ls Lighter The CLPX Boots Up Quickly The CL1 Uses Off The Shelf Parts The CL1 Is A Nice Unit The CLPX Is Cheaper HONEYWELL CONFIDENTIAL Honeywell General Vs Key Competitors It Seems Heavy On paper but also less ergonomic and a lot less capable Pick up a CLPX and a Flex at the same time and see if you still feel that way But there s more to it than that did you know that you re supposed to check the flow with a flow meter before each use But bet that s quick and easy Because there s no guarantee they ll be around in 10 years The Flex is backed up by Honeywell And by the way we sold the last SPM for 30 yrs Actually we agree As a fixed unit it s a solid piece of equipment But it has no portable capabilities limited communications functionality and zero certifications ltdoes however have a CE sticker with a web address to buy CE stickers Yep Honeywell Internal Honeywell Use Only Frequently Asked Questions 39 More Frequently Asked Questions Q called to order a SPM TLD Why should consider the SPM Flex As the newest member of the Honeywell Analytics toxic gas monitoring family the SPM Flex has been designed from the ground up to be the mo
25. oking to make large purchases should contact their RSM Q What comes in the box Do have to buy anything other than the unit All units come standard with battery power supply regional power cord user manual on CD and Quick Start Guide Depending on which configuration you go with the SPM Flex comes packaged with different accessories The Fixed unit includes a Standard Wall Mounting Bracket while the portable unit includes a handle assembly and clean room suitable shoulder strap No matter what configuration is ordered a SPM specific ChemCassette will also be required for operation Q What about ChemKeys You won t be needing any of those with the SPM Flex All the necessary information is built into the ChemCassette and any custom configuration is handled by the unit Honeywell Q Can install it via conduit A Yes an electrical connection can be made via 1 NPT conduit directly to the ports or via the connector Please contact a local electrician to ensure compliance with local codes Q I m going to hardwire the unit Can take the battery out A No the battery is integral to the operation of the unit and cannot be removed by the user or HA Q Does it have wifi A Not at this time but the team is looking at options to add that functionality in the future However we ultimately can t guarantee any non released functionality While we think this is something we want to do we can t promis
26. onsistent with past practices we ll give adequate time for customers to place any final orders for new production units as well as support any spares or consumables for at least five years While we have no obligation to support ChemCassette tapes beyond that period it has been our past practice to do so as long as it remains economically viable We are tentatively looking to announced EOL plans in January 2015 with 6 to 9 months for any final new product buys Q Are you doing a buyback program No we don t have any plans to do a buyback program at this time We ve seen very strong interest and we re confident in the customer value the Flex creates Consequently discounts and other incentives aren t in our current thinking Customers with large fleets should contact their RSM to discuss any specific commercial considerations RSMs have flexibility to offer certain terms and buybacks will be weighed with other discounts to maximize the value captured by HA HONEYWELL CONFIDENTIAL 40 More Frequently Asked Questions Q What about discounts used to get a good discount on SPM TLD As is typical with any new highly in demand product discounting is not a tool we re currently using Both the SPM and TLD were established products and while still very capable units candidly were in need of a refresh to bring them up to today s standard something we accounted for when pricing them Again customers lo
27. or for the unit and in certain applications Modbus TCP IP could be a spec which competitors can t easily meet Flexibility gives people a lot of options and helps future proof the product A strong industrial design makes the unit easier to interact with from up close or far away when mounted or fixed or semi fixed etc which means users are more likely to be willing to use it And all things being equal wouldn t you want the unit that s more updated and modern HONEYWELL CONFIDENTIAL Certifications Certification Description Honeywell CPLX CL1 Safety N America Safety Europe Unit EMC Radio Transmission Environmental Safety Safety N America Battery Safety Europe Battery N one UL Certified for USA and Canada to UL 61010 1 3rd Edition and CAN CSA C22 2 No 61010 1 31 Edition UL IEC CB Report for EN61010 3rd Edition European LVD UL Tested and Certified in USA Canada Europe Australia Korea Taiwan Singapore and China UL Tested and Certified in USA FCC Canada IC Europe R amp I TE Australia Korea Taiwan Singapore Malaysia and China Meets all applicable European Directives including ROHS WEEE Packaging Directive Battery Directive and REACH Intertek Certified for USA to UL 61010B 1 1st Edition UL Tested and Certified to UL 2054 2nd Edition UL 60950 1 2nd Edition and CAN CSA C22 2 No 60950 1 07 UL Report for IEC 62133 1st
28. re they in a location with service How often do they have to send units back to the factory HONEYWELL CONFIDENTIAL 35 SPM Flex Advantages Secondary Honeywell Advantage Highly Configurable Rugged Design Maximum Communications Options Superior User Experience for most gases Safety Much easier to comply with site specific rules or company policies Also updates via USB and the built in RFID mean they don t have to worry about being up to date Facilities Unit can be tailored to a specific job or worksite and with security in place its easy to ensure users only change what they really should be touching Safety take the unit anywhere there is an emergency and no need to baby it when you get there Facilities Durable design means it will last for a long time Safety amp Facilities Many different ways to interact with the unit Any end user Use the equipment every day so want it to be nice Harder to quantify and will likely be on a case by case basis That said How often do they update corporate policies How much customization are in those policies vs standard NIOSH recommendations How sensitive are their work areas Do lots of people have access Are their current units cleanroom compatible Can they just spray them off How much does the equipment get beat up and does it maintain the correct calibration when it does Built in webpage access is a major differentiat
29. s Both A Fixed And A Selection And Rugged Design Gases With More On The Way Portable Unit The SPM Flex Goes Ensure The SPM Flex Is Always Ensures You Always Have The Where You Need It With A Wide Ready When You Need It Detection You Need Array Of Communications Protocols To Keep You Informed Maximum Flexibility For Low Level Toxics Gases HONEYWELL CONFIDENTIAL Honeywell Designed For Rapid Response e Streamlined Steps To Monitor Power On Rapid boot sequence preps the unit for monitoring Load ChemCassette Simple to use cartridge design means no need to spool or wind tape Select The Gas Onscreen menu automatically shows available gases Need to monitor for a gas in a different family Just swap out the ChemCassette tape and choose the new gas Respond Significant automation on the SPM Flex handles the rest allowing users to focus on the task at hand What are minutes worth when responding to an alarm Would your users be able to respond in time to prevent an incident from becoming an emergency Flare eee ae Take up spindle Ready To Go In Under 2 Min So You Can Respond Quickly HONEYWELL CONFIDENTIAL Automation Of Critical Functions Homer RFID Populates Gas Information All necessary information about a ChemCassette is stored on the built in RFID including All available gases for that ChemCassette Default alarm levels for each gas Optimal flow settings for the tape
30. st flexible user friendly portable detector for low level toxics available today Automation has been greatly increased making it quicker easier and safer to use We ve also leveraged the same base unit for both portable and fixed configurations making it the most flexible monitor we ve ever made Refer to the sales presentation or brochure for additional details Q Does this replace the SPM or TLD Yes this product is ultimately designed to replace both the SPM and the TLD albeit while greatly adding functionality increased automation and improved usability to provide a best in class experience Q Why buy a new SPM TLDs if the Flex is so great We understand that customers sometimes want a consistent experience across their fleet The SPM and TLD remain tried and true products and we take pride in their longevity That said we re also confident in the customer value the Flex creates and once customers are ready to make the switch we ll work with them to ensure a smooth transition Honeywell Q So when are you announcing End of Life EOL on TLD and SPM While we don t currently have a publicly announced EOL on those products it doesn t make business sense to produce both the Flex and these very old 25 years units Once we re satisfied that SPM Flex production has stabilized and we re consistently delivering on our commitments to customers we will likely announce end of life plans C
31. table Unit for North America Sample Wand Kit Clean Room Suitable Shoulder Strap Handle for Portable configuration Weather Shield for use in Fixed configuration Questions Contact Honeywell Analytics For More Information Up To 2 Week Up To 30 Days Up To 90 Days 1265 4000 1265 4001 1265 4002 1265 4003 1265 4004 1265 4005 1265 4007 1265 4008 1265 4009 1265 4010 1265 4011 1265 4012 1265 3004 1265 3005 1265 3006 1265 3008 1265 3010 1265 3011 1265 3000 1265 3001 1265 3002 1265 3003 1265 3007 1265 3012 HONEYWELL CONFIDENTIAL Honeywell Base Unit Required ChemCassettes Required SPM Flex CC S XP Hydrides SPM Flex CC 5 XP Mineral Acids SPM Flex CC 5 XP Chlorine SPM Flex CC 5 XP Ammonia SPM Flex CC 5 Fluorine Oxidizers SPM Flex CC 5 Sulfur Dioxide SPM Flex CC 5 Diisocyanates SPM Flex CC 5 XP Phosgene SPM Flex CC 5 Hydrazine SPM Flex CC 5 Hydrogen Cyanide SPM Flex CC 5 Hydrogen Peroxide SPM Flex CC 5 Ozone SPM Flex CC 5 U XP Mineral Acids SPM Flex CC Fluorine Oxidizers 30 SPM Flex CC Sulfur Dioxide 30 SPM Flex CC Diisocyanates 30 SPM Flex CC Hydrazine 30 SPM Flex CC Hydrogen Peroxide 30 SPM Flex CC Ozone 30 SPM Flex CC XP Hydrides 90 SPM Flex CC XP Mineral Acids 90 SPM Flex CC XP Chlorine 90 SPM Flex CC XP Ammonia 90 SPM Flex CC XP Phosgene 90 SPM Flex CC U XP Mineral Acids 90 How To Order Optional SPMF PWRS 674333 674557 674556 674559 674560
32. vice are 1 replacement of the main battery 2 an issue with the PCB or 3 cleaning for customers with challenging environments such as diisocyanates Issues with the PCB require factory service due to the always on nature of the board In short it s a safety thing Q How do the gases compare to SPM amp TLD The SPM Flex has similar detection levels to the Vertex and is therefore superior to the SPM or TLD Please refer to A PAGE WE RE STILL WORKING ON for more information HONEYWELL CONFIDENTIAL 42 More Frequently Asked Questions Q Once A Custom Gas Setting Is Made How Long Is It Kept As long as the same ChemCassette type is used the last user settings will be maintained for all gasses within that ChemCassette type However once a user switches to a new ChemCassette type the gasses will start with the defaults from the gas tables Q How long is the warranty The SPM Flex is warranted under proper use 12 months from the date of first turn on or 18 months from delivery whichever is less ChemCassette cartridges are warranted for until the expiration date printed on each package and tape reel Q Do we have low level HF and what is the process for ordering it Because the calibration is stored on the RFID the ChemCassette is controlled rather than the unit or the software on the unit Standard calibration ChemCassette U meaning unrestricted for HF which does not require a license
33. viceability In Mind Highly user serviceable Pump filters stepper motor and gate motor are all serviceable by the end user in under 5 minutes Backed by the experts at Honeywell Send in your units only when you need to Comprehensive inspection cleaning and systems tests are recommended periodically depending on usage site conditions and gases monitored Maintenance Intervals months How easy is it to service your current Description equipment Authorized Honeywell preventive maintenance Replace the end of line filter What is the required maintenance today Oho er Checkforsystemieats and how much time does that take Verity optic system response Replace internal filters Replace real time coin battery or as needed Modular Design Improves Serviceability 12 HONEYWELL CONFIDENTIAL HONEYWELL CONFIDENTIAL Honeywell Gas List Honeywell ES CER Diborane BH 51000 pp awe CS ECOS OO poemas e ae Ee ll jeje e sxe em oo avon J gt EOI peel Le amine EC er A IAE Puan ES A E dE sem ECO ECC Industry Leading Gas Selec tion Gas List Detection Levels Subject To Change Check With Product Management For Latest Release Schedule 14 HONEYWELL CONFIDENTIAL Gas List tl Honeywell 5 90 RH 90 0 35 5 90 RH 0 90 RH fuente in pom o mn ZEN Cimethylanine OMA H ChSi 0 560pem Seem cee 0
34. years of reliable use a ae Also requires mounting bracket New Standard In Portable Gas Detection Honeywell Highly Automated Intuitive Operation Automation Improves Safety Accuracy And Usability RFID On Tape Sets Calibration And Flow Control Intuitive Easy To Understand User Interface e Flexible Application And Rugged Design Portable amp Fixed Means Less Spares And Training Industry Leading Gas Selection Up To 90 Day Tapes Software Enables Maximum Configurability e Easy To Service Reliable Use Critical Components Serviceable In Under 5 Min Stands Up To Changes In Temperature And Humidity Built For Long Lasting Operation Backed By Honeywell Advanced Capabilities Ready When You Are HONEYWELL CONFIDENTIAL 0000 al gt 4 Y ated Capabilities By Ready When You Are Key Components Top Assembly Seinen E mn EA pa em Gas Outlet Gate Assembly Interface Board Pump Gate Motor Filter Optics Not shown location only Block Stepper Motor RFID Not shown behind cover l Interface Cable Pump Quick Disconnect Tape Encoder 23 HONEYWELL CONFIDENTIAL Key Components Bottom Assembly Ethernet Modbus TCP Port os FA 7 H y I if 7 n Main Battery And Power Terminals Connector Flow amp Leak Sensors 24 HONEYWELL CONFIDENTIAL 25 Frequently Asked Questions Q

Download Pdf Manuals

image

Related Search

Related Contents

OM, Zenoah, BCZ2600, 刈払機, 2000-01  Philips Fiber optic cable SWA4302H  643 09 05 Rev1 UM Sanduicheira Bello Pane Inox 773470  Samsung 2243FW Užívateľská príručka  Griffin FireWave™ - Support  NIプライマー  NEC RWC-4717 User's Manual  PayPal Mobile Express Checkout Library - 2012 iOS Developer's Guide  Zotac ZBox AD06  musashi  

Copyright © All rights reserved.