1.    ChromaFlash    Plant Chromatin  Extraction Kit    Base Catalog   P 2022    PLEASE READ THIS ENTIRE USER GUIDE BEFORE USE    Uses  The ChromaFlash    Plant Chromatin Extraction Kit is suitable for isolating chromatin or DNA   protein complex from plants in a simple and rapid format  Chromatin prepared by using this kit can be  used in a variety of chromatin immunoprecipitation methods  It is the optimal method for preparing  chromatin required by Epigentek   s one hour ChIP procedure using the ChromaFlash    One Step ChIP  Kit  P 2025  or the ChromaFlash    Magnetic ChIP Kit  P 2026   The isolated chromatin can also be  used in other chromatin related applications such as in vitro protein DNA binding assays or nuclear  enzyme assays     Starting Material and Input amount  Starting materials can include various types of plant tissue   such as flowers  leaves  and young seedlings  The amount of tissue for each preparation can be  100 mg to 1 g  A total of 50 standard extractions can be performed with this kit  use 200 mg of  tissue per extraction   Yield of chromatin is approximately 0 5 to 2 ug per 200 mg of tissue   depending on the tissue type     Precautions  To avoid cross contamination  carefully pipette the sample or solution into the strip  wells  Use aerosol barrier pipette tips and always change pipette tips between liquid transfers   Wear gloves throughout the entire procedure  In case of contact between gloves and sample   change gloves immediately     110 Bi Coun
2.  in living cells by combining it with PCR  ChIP PCR   microarray  ChIP chip    or sequencing  ChIP Seq  techniques  When performing ChIP  chromatin or DNA protein  complex in plant tissues need to be first isolated in an efficient manner  However  the existing  methods used for plant chromatin preparation are inconvenient and time consuming  The  ChromaFlash    Plant Chromatin Extraction Kit addresses these issues by introducing the  following features     e Extremely fast procedure  the entire procedure from cell tissue sample to ready to use  chromatin is less than 2 hours     e Convenient and flexible  the kit is suitable for preparing both native chromatin and cross   linked chromatin from monolayer or Suspension cells  or from tissues     e Unsheared chromatin makes it customizable for various analysis workflows that require either  intact or fragmented chromatin  including ChIP  in vitro protein DNA interaction analysis   nuclear enzyme assay  etc     110 Bi County Blvd  Ste  122  Farmingdale  NY 11735 Page 3    Tel  1 877 374 4368 m Fax  1 718 484 3956 m E mail  info epigentek com m Web  www epigentek com    Printed 2013 12 13       Epigentek Group Inc  All rights reserved  Products are for research use only        PRINCIPLE  amp  PROCEDURE    The ChromaFlash Plant Chromatin Extraction Kit contains all the reagents required for carrying  out a successful chromatin extraction directly from plant tissues  Cell membranes of the sample   with or without cross linking  are 
3. broken down using the provided lysis buffer  Chromatin or DNA   protein complex is then extracted with the extraction buffer  The extracted chromatin can then be  diluted with chromatin buffer and stored at the appropriate temperature     Start with flowers  leaves        or seedlings 20  18  l 16  14  a 12  Lyse sample with lysis    buffer a 10       s  J     4  Extract chromatin with 9  extraction butter  rh     gc Trim ethyl H3 K27  Obtain isolated  chromatin  ChIP analysis of tri methyl H3 K27 enriched in  AGAMOUS gene with chromatin extract prepared  Schematic procedure of the ChromaFlash    from 2 week old icu2 1 icu2 1 seedlings using the  Plant Chromatin Extraction Kit  ChromaFlash    Plant Chromatin Extraction Kit     Assay Protocol    For the best results  please read the protocol in its entirety prior to starting your experiment   Starting Materials    Input Amount  Harvest 0 2 to 1 g of plant tissue  flowers  leaves  or young seedlings  after growth in  soil or in vitro in a 50 ml Falcon tube     Expected Yield  5 preparations can be performed when 1 g of tissue is used  0 2 g per extraction    1  Preparation of Working Buffers and Solutions    a  Prepare Working Lysis Buffer by adding 1 ml of 5X Lysis Buffer to every 4 ml of distilled water   Then add 4 ul of BME to every 10 ml of diluted Working Lysis Buffer  1X      b  Prepare Working Extraction Buffer A by adding 1 ul of BME to every 1 ml of Extraction Buffer A   c  Prepare Working Extraction Buffer B by addin
4. g 1 ul of BME to every 1 ml of Extraction Buffer B   110 Bi County Blvd  Ste  122  Farmingdale  NY 11735 Page A    Tel  1 877 374 4368 m Fax  1 718 484 3956 m E mail  info epigentek com m Web  www epigentek com Printed 2013 12 13     Epigentek Group Inc  All rights reserved  Products are for research use only     d        Prepare Working Extraction Buffer C by adding 1 ul of Protease Inhibitor Cocktail for every 1 ml of  Extraction Buffer C     Note  Put all working buffers on ice before use     2  Cell Collection and Cross Linking    Note  For tissues that are not cross linked  skip this section and go directly to step 3a of    Tissue Lysis  and Chromatin Extraction        Gently rinse tissue with 20 ml of deionized water  2 times  Remove as much water as possible from the  tissue  Place the tissue into a 50 ml conical tube  Then add 5 ml of 1 0  formaldehyde solution per  200 mg of tissue into the 50 ml conical tube     Stuff the top of the 50 ml conical tube  containing the formaldehyde soaked tissue  with nylon mesh to  keep the tissue immersed during vacuum infiltration  and to aid later rinse steps   Then poke several  needle sized holes in the cap of the conical tube and screw the cap on     Vacuum infiltrate the tissue for 10 minutes in a desiccator attached to a vacuum pump  The  formaldehyde solution should boil     Quench cross linking by adding 0 3 ml of 2M glycine per 5 ml of 1 0  formaldehyde solution  final  glycine concentration is 0 125M   Then continue vacuu
5. ich is  extraction reagents  6 months from the time of shipment  Expired  reagents may cause an inefficient extraction     Incorrect temperature and or Ensure the incubation times and  insufficient time during temperatures described in the protocol are  extraction  followed correctly     Chromatin Improper sample storage  Chromatin sample should be stored at  80  C  degradation  3 6 months   Avoid repeated freeze thawing  cycles        RELATED PRODUCTS    Chromatin Shearing and Cleanup    P 1006 DNA Concentrator Kit  Sonication Instruments  EQC 1000 EpiSonic    Multi Functional Bioprocessor 1000  ChIP Reaction  P 2025 ChromaFlash    One Step ChIP Kit  P 2026 ChromaFlash    Magnetic ChIP kit  PCR Analysis  P 1029 EpiQuik Quantitative PCR Fast Kit  110 Bi County Blvd  Ste  122  Farmingdale  NY 11735 Page 6    Tel  1 877 374 4368 m Fax  1 718 484 3956 m  E mail  info epigentek com m Web  www epigentek com    j   i 13 12 1     Epigentek Group Inc  All rights reserved  Products are for research use only  SAAE a i    
6. les at 20 seconds per cycle to increase chromatin extraction  Allow the  sample to cool on ice between sonication pulses for 30 seconds  For example  sonication can be  carried out with a microtip attached to Branson 450 sonifier  using the 25  power output setting     110 Bi County Blvd  Ste  122  Farmingdale  NY 11735 Page 5    Tel  1 877 374 4368 m Fax  1 718 484 3956 m E mail  info epigentek com m Web  www epigentek com    Printed 2013 12 13       Epigentek Group Inc  All rights reserved  Products are for research use only        g  Centrifuge at 12 000 rom at 4  C for 10 min     h  Transfer supernatant to a new vial     i  Add Chromatin Buffer at a 1 1 ratio  e g   add 50 ul of Chromatin Buffer to 50 ul of re suspended  chromatin      Now the chromatin solution can be used immediately or stored at    80   C after aliquoting until further  use  Avoid repeated freeze thaw cycles     TROUBLESHOOTING    Problem Possible Cause Suggestion    Low chromatin yield Insufficient sample size  To obtain the best results the sample size per  ChIP reaction should be between 100 200  mg of tissue     Insufficient chromatin  a  Check that all of the reagents have been   extraction  added in the correct volumes and in the  correct order based on the sample amount    b  check sample lysis under microscope  after addition of lysis buffer  and  c  check if  the plant tissue type is compatible with this  extraction procedure     Use of expired lysis or Check the expiration date of the kit  wh
7. m infiltration for an additional 5 minutes     Remove the formaldehyde and rinse the tissue 2 times with 20 ml of deionized water  After the rinses   remove as much water as possible  at this stage the cross linked tissue can be either frozen in liquid  nitrogen and stored at    80  C or used directly for chromatin extraction      3  Tissue Lysis and Chromatin Extraction    a     Grind the tissue in liquid nitrogen to a fine powder  Pour the powder into a 50 ml conical tube and add  4 ml of cold Working Lysis Buffer  1X  per 200 mg of tissue  Vortex and place on ice     Filter the solution through 2 layers of Miracloth into a 50 ml conical tube and centrifuge the filtered  solution at 4000 rom  1900X G  for 20 minutes     Remove supernatant and re suspend the pellet in 0 3 ml of Working Extraction Buffer A per 200 mg  of tissues  Transfer the resuspended pellet to 1 5 ml vial and centrifuge at 12 000 rom for 10 minutes  at 4  C to pellet nuclei  white pellet should be seen at this stage      Remove supernatant and re suspend the pellet in 100 ul of Working Extraction Buffer B per 200 mg  of tissues     Add 200 ul of Working Extraction Buffer B  per 200 mg of tissue  into a new 1 5 ml microcentrifuge  tube  Layer the re suspended pellet from Step 3d on top of this 200 ul cushion and centrifuge at  14 000 rpm for 45 min at 4  C     Remove supernatant and re suspend chromatin pellet in 50 ul of Working Extraction Buffer C per  200 mg of tissue     Note   Optional  Sonicate 2 cyc
8. ng step     Vacuum dessicator  for optional cross linking step     0 OF O 0 OQ    Nylon mesh  for optional cross linking step     GENERAL PRODUCT INFORMATION    Quality Control  Each lot of the ChromaFlash    Plant Chromatin Extraction Kit is tested against  predetermined specifications to ensure consistent product quality  Epigentek guarantees the  performance of all products in the manner described in our product instructions    Product Warranty  If this product does not meet your expectations  simply contact our technical  support unit or your regional distributor  We also encourage you to contact us if you have any  suggestions about product performance or new applications and techniques     Safety  Suitable lab coat  disposable gloves  and proper eye protection are required when working  with this product     Product Updates  Epigentek reserves the right to change or modify any product to enhance its  performance and design  The information in this User Guide is subject to change at any time without  notice  Thus  only use the User Guide that was supplied with the kit when using that kit     Usage Limitation  The ChromaFlash    Plant Chromatin Extraction Kit is for research use only  and is not intended for diagnostic or therapeutic application     A BRIEF OVERVIEW    Chromatin immunoprecipitation  ChIP  offers an advantageous tool for studying protein DNA  interaction  With ChIP  the experimenter can determine if a specific protein binds to specific  sequences of a gene
9. ty Blvd  Ste  122  Farmingdale  NY 11735 Page 1  Tel  1 877 374 4368 m Fax  1 718 484 3956 m E mail  info epigentek com   Web  www epigentek com Printed 2013 12 13     Epigentek Group Inc  All rights reserved  Products are for research use only        KIT CONTENTS    P 2022 050 o Receipt  aeaa o OO         Spin the solution down to the bottom prior to use     SHIPPING  amp  STORAGE    The kit is shipped in two parts  the first part at ambient room temperature and the second part on  frozen ice packs at 4  C     Upon receipt   1  Store Protease Inhibitor Cocktails at 4  C   2  Store remaining components at  room temperature     All components of the kit are stable for 6 months from the date of shipment  when stored properly     MATERIALS REQUIRED BUT NOT SUPPLIED    Sonicator   Vortex mixer   Centrifuge including desktop centrifuge  up to 14 000 rpm   Pipettes and pipette tips   1 5 ml microcentrifuge tubes   15 ml conical tube   50 ml conical tubes   Cells or tissues   Cell culture medium   B mercaptoethanol  BME     1X PBS    Oo 0 O OF 0 0 0 O0 O0 OO O OQ    Distilled water    110 Bi County Blvd  Ste  122  Farmingdale  NY 11735 Page 2  Tel  1 877 374 4368 m Fax  1 718 484 3956 m E mail  info epigentek com m Web  www epigentek com Printed 2013 12 13     Epigentek Group Inc  All rights reserved  Products are for research use only        Miracloth or similar filtration material    37  formaldehyde  for optional cross linking step   2 M glycine solution  for optional cross linki
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
ライカ DM750 取扱説明書 - Leica Microsystems  Avaya 1416 and 1408 Digital Telephones Release 4 Service Pack 2 User's Manual  Tripp Lite External Battery Frame for Extended Runtime for select SmartOnline 20kVA & 30kVA 3-Phase UPS Systems  Nokia 6110 Navigator Black  Owner's manual · Anleitung Handleiding · Mode d - NT    Copyright © All rights reserved. 