Home

PEL 100 Series - Chauvin Arnoux Group

image

Contents

1. J Power amp Energy Logger oe PEL 100 Series 3 gt Simple To Use Models PEL 102 amp PEL 103 7 Simpla to usa singla T PAIET fen dual split phase and Ba ls RN ENTS a i ia three phase Y A power _ All You Need For wer amp Energy Logge Ae and energy loggers fe gt Designed to work in 1000V CAT III and 600V CAT IV environments and fits in many distribution panels ee PAS gt Power measurements E E VA W and var E gt Energy measurements j VAh Wh Source load and ath 4 qlladtants fy gt Dataview software Mres storage real time display i analysis and report generation i with supplied pre defined ory fhe ae Dn i gt inimal p oan rN gt Etherne hcomipatible pe Boctoll Class 1 en ommuni ation up to Loo S way m Batistes the requirements of POWER amp ENERGY LOGGER ON OFF 1 START STOP reo ff o s gt ED NEC 22087 g g p A e HT Ak i 2 _ ET 44 DA z S n i f a7 ohFEr GAFE ame A 1000V ER E D gt CAT III ER Our products are backed by over 100 years of experience in test and measurement equipment and encompass the latest international standards for quality and safety R J Technical Hotline 800 343 1391 AEMCG INSTRUMENTS o www aemc com CHAUVIN ARNOUX GROUP Sa PEL 100 Series MODEL PEL 102 POWER amp ENERGY LOGGER Model PEL 102
2. Model PEL 103 The PEL 100 series is a low cost simple to use single dual split phase and three phase Y A power and energy data logger There are two models available Model PEL 102 no display and Model PEL 103 with a backlit digital display This product is ideal for electricians engineers and contractors doing work in the area of building and system monitoring and upgrades as well as residential and overall energy audits All vital energy data is easily measured recorded and analyzed Reports can be generated with confidence with minimal configuration time and effort Standard and Customizable Reports supplied The PEL 100 series has many up to date features demanded by the present market conditions for energy and power consumption information needs The instrument s design enables it to be installed inside a load center panel including the current sensors allowing the door to close on most panels The PEL 100 series offers all the essential functions for logging power and energy data from most electrical power networks in use today across the world 17 network set ups provided The PEL 100 series power and energy loggers measure and record three voltage inputs and current inputs Watts VARS VA and Energy kWh and kVA Power Factor PF Displacement Power Factor DPF Crest Factor Frequency and THD are calculated and recorded as well Individual harmonic information from 1 to the 50th harmonic are r
3. 50mA 305 5 EET 5 a 190mm 400Aac 20 to 500A 1 0 2A 05 0 5 swan azwan efe Traan 5 7 0 78 200Aac oe to 100A ae poe ae 0 8 100A 20mm soo ean aeea 1 2008 nS mf ali _ see oza 20mm 250mA to 6A 1 1 7 0 5 5A 100Aac Dc 2 0r OMEO Maximum current reduced by a factor of 2 for 400Hz fundamental frequency Max Conductor Size Sensor Type MiniFlex MA193 10 Sensor 290mm MN93 AC DC Current Probe BNC Adapter for Model SL261 only Catalog 2140 40 INSTRUMENTS Technical Assistance 800 343 1391 www aemc com 5 Key Features of the PEL 103 Display Measured Phase Indicator Measurement Values K O ee ek M 14 15 E 7y Information Display Bar E gt T E T SES D T D lt A X Bargraph gt Load factor Min Max The bargraph indicates the percentage 0 to 100 of full range or full load as L2 L3 E lt programmed into the PEL by the user through the DataView software E gt D D D T D Ee D lt A se i C E C C A lt Measurement Units D D E D CES Sy D S A lt T g C a C nnsa o o A D DD D D OD marz Page Tie E A AD A A AN AN AN war E z E 9 te Mode Selection Display Bar Top and Bottom Display Bars Indicate the Following DESCRIPTION Phase Sequenc
4. In this display the network hook up PT and CT primary and secondary values can be displayed as well as the IP address if connected to the Ethernet Software and Firmware version and serial number www aemc com 7 Datav ew CONTROL PANEL DataView software provides a convenient way to configure and control power and energy tests from a computer Through the use of clear and easy to use tabbed dialog boxes all PEL 100 series functions can be configured and tests can be initiated Results can be displayed in real time and stored on a PC Reports may be printed along with the operator s comments and analysis General Communication Measurement Recording Meters Instrument identification Model PEL 103 AEMC Serial number PROTO 005 Name Control Room C l 32 characters max Location Foxborough MA 32 characters max Auto power off Contrast 3min 10min Normal mode brightness 15min Disable Stand by mode brightness E Lock out the Control button on the instrument front panel This will prevent the start and stop of recording also the enabling and disabling of Bluetooth at the instrument The instrument dock differs from this computer s dock by 22171 second s Basic information regarding Auto Power Off instrument name and location display brightness and contrast Model PEL 103 setting of the real time clock and SD card formatting is easily accomplished
5. Jf ric eat ve mame Took Hep or tabular lists eH BBWeSlsiaalxXiQAnaaakeaoo m Tools Menu Bar Alsologger lt f Gence a a a Parameter selection when J grr e E Selection Buttons multiple loggers f B worsen cain Con Cari aA cane windon MN Wadon NE Wacon are detected is rue d eee eee Tabular Listing of Data accomplished i at Cursor Position in the control ae M Ree Movable Cursor Data Plot Listing Area 3 12 2012 11 15 00 AM 1 min Div Logger Navigation Tree GJ AEMC INSTRUMENTS Technical Assistance 800 343 1391 www aemc com 9 Four safety banana jack voltage measurement terminals Rigid molded casing over molded with thermo adhesive rubber gt gt MODEL PEL 103 Digital LCD displaying measured calculated and parameterizing quantities PEL 103 only Two PEL 102 or four PEL 103 function buttons POWER amp ENERGY LOGGER LED status indicators ON OFF START STOP se oL S gt ED Standard IEC C7 terminal non polarized power connector for 110 250 Vac power source SD memory card USB Port Terminal cover caps not shown MOUNTING F Models PEL 102 and PEL 103 can be mounted on a door or other object using the Multifix mounting attachment included Models PEL 102 and PEL 103 are equipped with four power
6. Multifix Universal Mounting System Cat 5000 44 pb TE YA A A oxen Eo e OE 25 12 Color coded ID Markers 3 MiniFlex Sensors Model MA193 10 BK for Test Leads Cat 2140 48 4 Black Test Leads and Alligator Clips Cat 2140 45 Included with select models Cat 2137 76 PusdsuUeAL y 1 5ft USB Cable 1 USB Stick with DataView 1 USB SD Card Cat 2140 46 and User Manual Reader for PC Cat 5000 45 1 Power Cord Cat 5000 14 CJ AEMC INSTRUMENTS Technical Assistance 800 343 1391 www aemc com 11 Model PEL 102 is a cost effective energy monitoring solution that can be mounted in unattended areas allowing real time and recorded data to be reviewed remotely via Ethernet or Bluetooth communication DESCRIPTION CATALOG NO Models PEL 102 and PEL 103 include Small Classic Tool Bag Three MiniFlex MA193 10 BK Sensors included with select models 5 ft USB Cable Four Black Test Leads and Alligator Clips Power Cord 12 Color coded ID Markers Multifix Mounting System Safety Card for the PEL Sensor Compliance Sheet 2 GB SD Card with USB SD Card Reader Quick Start User Guide and USB Stick with DataView and User Manual Power amp Energy Logger Model PEL 102 no LCD w 3 MA193 10 BK sensors 2137 51 Power amp Energy Logger Model PEL 103 with LCD w 3 MA193 10 BK sensors 2137 52 Power amp Energy Logger Model PEL 102 no LCD no sensors 2137 61 Power amp Energy Logger Mod
7. 91 508 698 2115 Fax 508 698 2118 Export Department 603 749 6434 ext 520 Fax 603 742 2346 E mail export aemc com Visit our website at www aemc com 950 BR PEL100_ 1213 Rev01 Printed in the USA
8. e reversal indicator or missing phase displayed in 3 Phase distribution systems Data available for recording non display indicates possible internal problem Measurement Mode Real Time values The backlit display on the Model PEL 103 can be read in dark areas showing the real time measurements MC 6 www aemc com Technical Assistance 800 343 1391 INSTRUMENTS The PEL 103 display provides real time information for all the measured and calculated values that are recorded The left right navigation button scrolls through the display modes while the up down navigation button scrolls through the available real time measurements for the selected display mode Measurement Mode NY W im Nw O Real time updates are displayed for voltage current power frequency power factor and tangent Energy Mode Real and apparent energy can be displayed along with an indicator identifying whether the energy is used by the load or supplied back to the source Reactive energy can also be displayed with source load capacitive or inductive properties indicated AEMG Technical Assistance 800 343 1391 Harmonic Mode O Total Harmonic Distortion THD can be displayed by phase or phase to phase Neutral current THD can also be displayed Min Max Mode Min Max values for voltage current including neutral current power and harmonics Information Mode Jf a IL IAN _ N W m SO amp
9. ecorded at the operator s choice All variables are recorded and stored at a one second interval and on user selectable demand intervals from 1 to 60 minutes Energy costs can be calculated and displayed quickly and easily by simply inputting the unit cost for a kilowatt hour into the software Data is stored on a removable SD card Data can be retrieved using a USB cable Bluetooth and or the Ethernet local or internet connection or by transporting the 2 www aemc com SD card back to a PC The comprehensive DataView software included provides the ability to view data from several hundred PEL 100 series instruments on a local network or over the internet allowing the user to evaluate energy usage ina department or facility basis a remote site or even in a city anywhere in the world DataView allows measurements to be viewed in real time on a PC and stored data to be downloaded for analysis and report generation Configuration of the PEL 100 series instruments is accomplished through DataView software either locally or remotely Most of the configured parameters are pre set in the instrument keeping the user interface very simple and straightforward Current probes are automatically detected and scaled to a pre defined or user specified configuration when connected to the instrument User selections include network type demand interval recording length voltage and current ratios where necessary recording duration defin
10. ed either by time and or date and communication method Password protection can be configured for Bluetooth and network communication to guard against unauthorized access and protection of data integrity The DataView software provides the ability to view power harmonic for AC measurements and RMS as well as DC data in real time and download recorded sessions for more extensive analysis and report generation One second trend data demand interval trend graphs and tabular listings can be displayed and printed Energy costs can be calculated from the downloaded session Source and load graphs can be plotted Individual phase and the sum of all phases can be evaluated Once data is downloaded and displayed the user has access to a variety of tools to analyze individual data points or sections of the recorded data without the frustration of having to deal with layers of button pushing This simple to use yet comprehensive power and energy logger will be an invaluable asset to your power and energy monitoring and analysis needs POWER amp ENERGY LOGGEN pa i The PEL 100 series energy loggers can safely and easily facilitate voltage and current hook ups M Technical Assistance 800 343 1391 INSTRUMENTS gt FEATURES gt Simple to use single dual split phase gt DISTRIBUTION SYSTEMS and three phase Y A power and energy loggers Provides all the necessary functions for Power and Energy data l
11. el PEL 103 with LCD no sensors 2137 62 Accessories and Replacement Parts Optional AC DC Current Probe Model MR193 BK 2140 28 AC Current Probe Model MN93 BK 2140 32 AC Current Probe Model SR193 BK 2140 33 AmpFlex Sensor 24 Model 193 24 BK 2140 34 AmpFlex Sensor 36 Model 193 36 BK 2140 35 AC Current Probe Model MN193 BK 2140 36 MiniFlex Current Sensor 10 Model MA193 10 BK 2140 48 AC DC Current Probe Model SL261 1201 51 Replacement Small classic tool bag 2133 72 Replacement Battery custom factory replacement NiMH AAA 8 4V 2137 75 Replacement Set of 4 black test leads 10 ft 8m 4 black alligator clips and 12 color coded ID markers 2137 76 Replacement Set of 12 color coded input ID markers 2140 45 Replacement USB cable A B 5 ft 1 5m 2140 46 Replacement Power cord 5 ft 1 5m 115V 5000 14 Replacement Multifix universal mounting system 5000 44 Replacement USB SD card reader for PC 5000 45 USB cable A B 10 ft 8m 2136 80 BNC adapter for SL261 current probe Anti thief Kensington Laptop Security Cable available in most office supply stores AEMC CI source For All Your Electrical Test amp Measurement Instruments Call the AEMC Instruments Technical Assistance Hotline for immediate consultation with an applications engineer 800 343 1391 Chauvin Arnoux Inc d b a AEMC Instruments 200 Foxborough Blvd e Foxborough MA 02035 USA e 800 343 13
12. from the General tab Nominal voltage and voltage ratios Set a Voltage Transformer Ratio Primary 100 v 50 650000 Phase to phase Phase to neutral Secondary 100 v 50 650000 Phase to phase Phase to neutral Current measurement AmpFLEX MiniFLEX MN93A damp 5 A Range 100A 2000A F An external CT is used 400A 10000A Primary 10000 Number of primary wraps 1 1 2or 3 Secondary 5 Multiple primary wraps will increase the sensitivity of the however the nominal current will be 5 A adapter box divided by the number of primary wraps F An external CT is used For example with 2 primary wraps for a 2000 A range Primary 10000 the nominal current will be 1000 A instead of 2000 A Secondary 5 Current sensor with BNC adapter Nominal current 1000 A 1 25000 Output voltage 1 v Sensor output voltage must not exceed 1 7 V peak The Measurement tab specifies the electrical distribution system voltage ratios nominal frequency and current probe options and ratios 8 www aemc com Visible Invisbh PEL 103 PROT 301 MAC address 00 0B8 3C 32 2E FE Enable DHCP IP address MB ei e nt UDP portnumber 3041 Bluetooth Network password V Enable password protection Password 0000 16 characters max This password will be required when configuring the instrument via Bluetooth and Ethernet network connections The Communication tab provides
13. ful magnets for mounting the instrument on a metallic surface 10 www aemc com Ethernet RJ 45 Port Three current input terminals on the top of the instrument with automatic recognition of the current sensors Mounting magnets molded into the rubber casing Keyhole mounting bracket Mounting magnets molded into the rubber casing Io CE gt SI CAT I oe CAT Ill ETHERNET Anti theft Kensington Security Slot on side not shown Compact side view of Models PEL 102 and PEL 103 Models PEL 102 and PEL 103 easily mount in a panel with the cover in place CJ AEMC Technical Assistance 800 343 1391 INSTRUMENTS Assurance Guaranteed The PEL 102 and PEL 103 power and energy loggers come complete with all the required components and accessories to conduct your power and energy recording data analysis and report generation No worrying or second guessing if you purchased everything to get the job done It all comes neatly packaged in a convenient canvas carrying bag with multiple pockets to store all the components with easy access when needed gt INCLUDED WITH EACH MODEL MODEL PEL 102 MODEL PEL 103 1 Small Classic Tool Bag Cat 2133 72 1 Power Energy Logger PEL 102 no LCD w 3 MA193 10 BK sensors Cat 2137 51 PEL 103 with LCD w 3 MA193 10 BK sensors Cat 2137 52 PEL 102 no LCD no sensors Cat 2137 61 PEL 103 with LCD no sensors Cat 2137 62 1
14. gers with DataView File Edit View Instrument Tools Help SS Ase AXAR AA RT O m e Display real time data on a PC TE pram gt Configure all PEL 100 series functions Toa and parameters from your PC Q Real time Data kes gt Poll multiple energy loggers from your PC 5 My Open Sessions jpa gt Customize views templates and reports E serors to meet specific needs E Batiment C Bima gt Export data to spreadsheets gt Zoom in and out and pan through sections of the graph to analyze the data gt Display trend graphs harmonic spectrums text summaries and event logs atten aaa gt Print reports using supplied pre defined ae ia aaa oS or custom templates eeren gt Selectively review values phases or Reports can be displayed on a PC and printed Each report includes all test total network recordings results in a tabular and graphic format as well as operator and test site gt Keep track of accumulated energy and information Comments typed by the operator will also be included cost over time gt Create user specific cover sheets for reports that identify specific data that includes operator tests site and narrative In the PEL control panel you associated with the data will find all the necessary tools and selection buttons to review recorded data ye Cool Pare Clee eee TEE _ lt __ TTitle Bar AS trend Plots
15. information about the various communication mediums supported by the instrument with clear and easy setup of all functions from one dialog box E Schedule recording Startdate 6 19 2012 OY Start time 12 05 54PM Enddate 6 19 2012 Jy End time 8 05 54PM H Reset StartDate Time Trends demand interval Period The aggregation starts at rounded hours Recording options F Record one second trends F Record current and voltage harmonics Longest possible recording is 47 days because of the limitation of file size 4 GB in FAT32 regardless of available memory Caution Recording harmonics will consume a considerable amount of storage space and will greatly increase download and analysis time see help for more information Installed SD Card status 1 07 of the SD Card space has been used 1898 MB is available on the installed SD Card 1919 MBis the total capacity of the SD Card In the Recording tab configure the instrument to measure and record over a user selectable recording period from a few hours to a month or longer Select demand intervals from one to sixty minutes and view available memory for data storage M Technical Assistance 800 343 1391 INSTRUMENTS DataView a DataView is 2g included with NEW amp Models PEL 102 IMPROVED E and PEL 103 on a USB stick SOFTWARE ne ort NE Configure all functions of the PEL 100 Series Log
16. le slot on back side Kensington anti theft system Security DISPLAY Display Type for Model PEL 103 ENVIRONMENTAL Operating Temperature Relative Humidity 32 to 122 F 0 to 50 C up to 85 Storage Temperature 4 to 122 F 20 to 50 C with batteries 4 to 158 F 20 to 70 C without batteries SAFETY 2 63 x 2 16 67 x 55mm four line monochrome backlit LCD with adjustable brightness and contrast Safety Rating CE Rating Complies with IEC 61010 1 Ed3 and IEC 61010 2 030 Ed1 for 1000V CAT III 600V CAT IV Pollution Degree 2 CE Marked Maximum value is current probe dependent Computers with Class Il Bluetooth will restrict range to 40ft Computers without Bluetooth will require a Class or Class Il Bluetooth radio adapter Maximum current reduced by a factor of 2 for 400Hz fundamental frequency c 4 www aemc com Technical Assistance 800 343 1391 INSTRUMENTS A complete family of current measurement probes to meet most AC or DC measurement applications up to 10 000Arms Typical Maximum Typical Nominal RMS or DC Accuracy Error Error Error Current Current ROF a Oe on at 50 60Hz 50 60Hz 400Hz 2000Aac 100 to 2400A 41 1A aa 70mm 10 10 000AK 900 to 12 500 0 12 0008 08 8 08 5 MR193 50101008 1 5 1A 25 4 5 A 0 _ O 1000Aac 1000A 52mm 100 to 1200A 0 3 0 2 0 7 AmpFlex 193 100k 5 to BWIA 1
17. ogging for 50Hz 60Hz 400Hz and DC distribution systems Current measurements from 200mA up to 10 000A using flexible current sensors Power measurements VA W and var Energy measurements VAh Wh source load indication and varh including quadrant indication Record cost of energy usage Power Factor PF Cos Tan and DPF Crest Factor Total Harmonic Distortion THD for voltages and currents Harmonics up to the 50 order for 50 60Hz voltages and currents and 7th order for 400Hz Freq uency measurements Simultaneous RMS measurements of each phase 128 samples cycle and DC Bright blue four line LCD on the Model PEL 103 3 phases shown simultaneously Storage of measured and calculated values on a SD Card or SDHC Card Automatic recognition of the connected current sensors probes Configuration of current and voltage ratios to external PT and CT ratios 17 types of hook ups for supported electrical distribution systems USB LAN and Bluetooth communication Includes DataView software for data storage real time display analysis and report generation with supplied pre defined or custom templates CJ AEMC INSTRUMENTS Technical Assistance 800 343 1391 SUPPORTED gt Single Phase 2 Wire gt Single Phase 3 Wire Split phase from a center tap transformer Three Phase 3 Wire Power Networks gt Three phase 3 wire A with two current sensors gt Three phase 3 wire A with three curren
18. se Crest Factor CF Cos f DPF 2GB SD card included is used for storage SD cards up to 2GB SDHC cards 4 to 32GB formatted FAT32 are supported INPUTS Current _ 3 current input channels via custom 4 pin jacks that accept AEMC probes and sensors shown on page 5 ELECTRICAL VOLTAGE MEASUREMENT RANGE RESOLUTION ACCURACY of Reading HOH HP 0 2 Rdg 0 4 T r 1 Rdg 1V 1 Rdg 1V 100 to 1000V 1 Rdg 3V typical PT Ratios Programmable from 50V to 65 0000V 0 01V to 0 1V primary and secondary CURRENT MEASUREMENT Current Probe MiniFlex Sensor MA193 1 2 0 2A For further specifications and other compatible oiim ont probes meee hart on page Programmable from 1 1 to 25 000 1 probe dependent POWER MEASUREMENTS ENERGY MEASUREMENTS Active Energy EP Reactive Energy EQ Apparent Energy ES 0to4x10 0 5 Rdg Oto 4 x 10 2 Rdg Oto 4 x 10 0 5 Rdg 655 1 to 50 displayed in percentage 1 to 7 at 400Hz THD Individual Harmonics External Supply 110V 250V 10 50 60Hz 400Hz Back Up Power Source Charge Time Rechargeable 8 4V NiMH battery pack Approximately 5 hours MECHANICAL Communication Ports USB 2 0 Ethernet RJ45 Wireless Bluetooth Class 1 10 08 x 4 92 x 1 46 256 x 125 x 37mm lt 1kg Case Index of Protection Double insulated rubber over molded polycarbonate UL94 V1 rated IP54 non operating Embedded magnets on back side keyho
19. t sensors gt Three phase 3 wire Open A with two current sensors gt Three phase 3 wire Open A with three current sensors gt Three phase 3 wire Y with two current sensors gt Three phase 3 wire Y with three current sensors gt Three phase 3 wire A Balanced with one current sensor Three phase 4 Wire Y Power Networks gt Three phase 4 wire Y with three current sensors gt Three phase 4 wire Y Balanced gt Three phase 4 wire Y 2 2 Element gt Three phase 4 wire A gt Three phase 4 wire Open A DC Power Networks gt DC 2 wire gt DC 3 wire gt DC 4 wire gt APPLICATIONS gt Measure efficiency and find areas for potential savings gt Track sub billing occupants for energy costs gt Assign energy costs to departments or operations within a department gt Track peak demand periods and find opportunities for surcharge reductions gt Determine present capacity and circumvent unnecessary electrical expansion costs gt Verify the reliability and operation of electrical machinery gt Improve response time to solve power related problems gt Track energy availability and reliability of supply gt Reduce field service time at sub stations gt Baseline studies for system upgrades in high rise and office buildings www aemc com 3 GENERAL Recorded Parameters V W VA var PF Tan Wh Vah varh THD V and Single and Poly Phase Individual harmonics from 1 through 50 per pha

Download Pdf Manuals

image

Related Search

Related Contents

INSPECCION INTERIOR DE AERONAVE  PDFファイル  PRELIMINARY USER MANUAL - AV-iQ  69-2698EFS-01 - FocusPRO TH5000 Series  Nokia 6555 2" 97g  installation instructions  Nokia Lumia 925 User Guide PDF - File Delivery Service  User Manual - Administration - Enterprise Resource Planning  Wentronic 93426-GB networking cable  KV-21CE10E  