Home

WR-3 User Manual

image

Contents

1. button pressed for 2 seconds when function selected Mode 4 Average speed current speed depends on selection in the setting menu SETTINGS By holding the left button F pressed after 4 seconds the menus for different groups of settings will start appearing in 1 second steps Release the button on selected menu With presses of left or right button you can the adjust the value or select between options within the selected menu After 5 seconds of non pressing the button instrument will return to normal operation Menus Adjust alarm limit Select the average period for average speed 10 sec 30 sec 2 min or 5 min Select the address correspondent to sensor address from which you wish to receive data Select the unit of wind soeed measurement m s km h knots or mph Select the unit of temperature measurement C or F ed a TEMPERATURE MEASUREMENT The temperature sensor is located within the sensor It can take up to 30 minutes to sensor reach the surrounding air temperature SENSOR ADDRESS Always set the address correspondent to address of sensor from which the receiver will receive the data Address of sensor is marked on sensor and also in the interior of battery compartment ALARM When the current wind speed exceed the pre set value the H i sign blinks on the display At SWR3 A type audible alarm is also activated WINDCHILL Wind cill function gives us information how cold it feels because of combined effect
2. of current air temperature and wind speed The anemometer automatically calculates and displays this subjective temperature according to the latest formula BATTERY REPLACEMENT Sensor when the sign Lb starts appearing on the display replace the sensor battery Take off the battery cover by turning it anti clockwise Pull out the battery holder and insert new battery NOTE Do not open battery cover unnecessarily It is sealed with sealant Display unit when display starts losing contrast replace the battery Battery is placed under the lid at the backside of the display unit RANGE Connection between sensor and display unit work on free 868 MHz band Reach is up to 400 meters when no obstacle is between sensor and display unit Inside the building the range is much shorter Normally the signal can go through two to three walls TECHNICAL DATA Wind speed measurement range 0 8 50 m s Temperature measurement range 30 60 C Wind speed units m s km h knots mph Bft Temperature units ICPF Wind speed resolution 0 1 unit under 9 9 1 unit above 10 Temperature resolution T C Wind speed accuracy typ 3 Temperature accuracy 1 C Averaging period settable 10 sec 30 Sec 2 min or 5 min Display updating every 2 sec Data transmission every 2 sec Transmission frequency 868 MHz Battery Sensor 3 6 V lithium battery AA mignon Battery receiver AA mignon alkaline Dimensions Sensor height 210 mm Sensor diameter
3. Long Range Wireless Anemometer SWR 3 User Manual Date 2014 7 21 Operation Sensor Unit Switches ON automatically when the anemometer cups revolve It switches OFF 2 minutes after the anemometer cups stop revolving Display Unit Switching ON Press the right button Switching OFF Long press the right button for 3 seconds Backlighting Short press right button when device is ON In the case display unit has no signal from sensor or sensor is out of range for 10 unites it switches to power saving mode In that mode it checks every 10 seconds if sensor sends data Due to power saving mode the first wind speed value can be delayed up to 10 seconds before it is displayed As soon as display unit detects sensor it switches to normal mode and displays current values every 2 seconds In the case display unit has no valid data from sensor for 10 seconds it displays two dashes Segment 12 of Bft graph blinks when the display unit receive data from the sensor Functions Wind speed measurement in m s km h knots or mph Current average and maximum wind speed Bar graph for wind speed in Beaufort scale always shows current speed Temperature Wind chill SELECTING THE FUNCTIONS ON LOWER DIGITS By pressing the left button F four different functions will alternate on lower digits Mode 1 Temperatuer Mode 2 Wind chill Mode 3 Maximum speed maximum current speed since Power ON Maximum speed reset by holding the left
4. cup to cup 120 mm Display unit 94X63x28mm Alternations in specification are subject to changes without notice MASTER RESET OF DISPLAY UNIT Hold pressed left button when insert the battery This will reset the receiver and return parameters to factory settings Press adjust the corresponding sensor address after resetting the receiver Limited warranty This product is guaranteed for one year after date of purchase During limited warranty period any defective product will be repair or replace with comparable product without charges The limited warranty does not cover battery and damages of any kind including physical caused accidentally or from misses Manufacturer s responsibility is limited to repair replace the only when returned to the store where it was purchased together with original invoice FUNTION Mode 1 Mode 2 Mode 3 Mode 4 Wind speed Wind speed Wind speed Wind speed Maximum wind speed Average wind speed Temperature Wind chill temperature short press co H short press Che dJe Alternate press button for 2 sec to reset max speed SETTINGS Menu 1 Menu 2 Menu 3 Menu 4 Menu 5 Alarm Averaging Sensor Wind speed Temperature limit Jn address unit unit Hold down the left button 4 SeS g a 1 1 1 f4 second Ru id EEs Adjust with iR Select with Select with J Select with 3 Select we f left and right button left and nght en left and right button left and right button ef and nigh b
5. utor 4 4 3 10 10s m s or 30 30s 5 i 2 2 min km h gt E 5 5 min kn mph x CE