1. Sadlean 2 CPAP Sanitizer User Guide Thank You Thank you for your purchase of the SoClean 2 CPAP sanitizing system At Better Rest Solutions we are committed to providing innovative and safe methods that can improve the health and well being of our customers We hope that the SoClean will do just that for you Please familiarize yourself with this manual and the operation of the unit After a few easy steps you ll find that daily sanitizing of your CPAP equipment has never been easier This unique process eliminates bacteria mold viruses and other pathogens It does all this by using gaseous activated oxygen alone no need for liquid sanitizers or messy preparations Please feel free to contact us with any questions or concerns you might have BetterRest Contents 1 Safety and Technical Specifications oooooconicnconononnnncnnononononanonararcnnnnns 4 2 Included with your SoClean ana ee 5 Se Important SUP DIGS permanencia 6 Ah Getting A ina E i AEE EA AEDA Ea vine a ENEA EA 7 Sy YOUR SOC am TIME amp DISplay ada 11 o E a E es 15 7 Maintaining your SoClean ssssseesssesttttstrtn ttrt rrtt tt tt tEEE EEEn EErEE EEEEE EEE 17 Cy E CO PA A Po A 18 Safety and Technical Specs T DANGER Keep away from water sources including rain bathtubs sinks and pools DANGER Keep away from children It is not a toy DANGER Do not use in explosive air environments near gas vapors or other flammables
2. This would indicate that the SoClean did not carry out its scheduled sanitizing Common reasons for this are that the lid was not securely closed there was no mask in the chamber at cleaning time or the open hose slot plug is missing or not properly seated 7 What if missed my scheduled sanitizing time but still wish to sanitize my equipment In these instances you can use the Manual feature See your User Guide on how to do this see page 13 8 Why does my display say Order Filter Kit This message appears approximately every 6 months depending upon usage as a reminder to regularly replace the filter and check valve assembly 9 Are there materials that should avoid putting into the SoClean Nylon and natural rubber break down when exposed to activated oxygen Most manufacturers typically do not use these materials in their reservoirs hoses masks or headgear If you have questions in this regard contact your CPAP manufacturer supplier or Better Rest Solutions 10 Will I ever need to wash my CPAP equipment again The SoClean is intended to supplement not replace the manufacturer s recommendations for cleaning their equipment For further questions or concerns please feel free to search our website www betterrestsolutions com or contact us at 866 501 3705 19 USER GUIDE For more information about SoClean 2 or our other innovative products please visit www betterrestsolutions com Copyrig
3. etc DANGER Do not place any items on top of SoClean Unit particularly flammables or ignitable items DANGER Never place any living thing including pets inside WARNING Do not dismantle the SoClean unit WARNING Do not run the SoClean for more than 30 minutes consecutively WARNING Please be aware that there are sensitive electronics inside the SoClean If you need to clean your SoClean wipe with a damp cloth Do not submerge your SoClean or use any chemical cleaners to clean out the inside of the SoClean chamber P gt Rr gt gt gt gt Weight 5 6 lbs Dimension 7 5 x 6 5 w x 8 5 h Cord Length 4 8 Electrical 12 VDC Power consumption 5 Watts Warranty 1 year warranty Included with your SoClean Removable hose slot plug installed To O E filter cartridge installed AC power adapter SoClean check valve assembly with injection fitting and hose installed Neutralizing pre wash Important supplies Ly Check Valve Assembly installed Prevents water in your humidifier reservoir from backing up into your SoClean machine If you can see water in the clear tube replace the check valve assembly immediately Replace every 6 months Filter Cartridge installed This filter converts activated oxygen back into normal oxygen Replace every 6 months Neutralizing Pre Wash Fragrance free hypoallergenic
4. hose slot Note The SoClean gives you the option of inserting your mask and hose from either side of the machine To change sides remove the hose slot plug from its position by lifting it straight out and insert it into the slot on the opposite side 3 Close the lid The SoClean will now automatically operate according to its preset time and duration Note The SoClean will never operate without the mask and hose present in the securely closed chamber Additionally the SoClean will not operate if the hose slot plug is missing or improperly seated Important Even though the actual run time of the SoClean may only be 5 to 10 minutes it is necessary to let the mask remain in the closed chamber for at least 2 more hours After that pe riod the cycle indicator light will shine green as a sign that all sanitizing is complete and the mask is ready to be removed from the chamber Maintaining Your SoClean To remove dust you may wipe down the SoClean with a damp cloth The SoClean check valve assembly and filter cartridge should be replaced every 6 months A reminder message on the display will appear after approximately 6 months depending upon usage Visit www BetterRestSolutions com or an authorized distributor to purchase a Cartridge Filter Kit a 1 ce Check Valve Assembly REPLACE EVERY 6 MONTHS Cartridge Filter REPLACE EVERY 6 MONTHS 17 FAQ 1 Will my CPAP equi
5. Press the button to save your setting 13 Your SoClean Timer amp Display continued Hose a manuan presen E Order Gant R iter Ni E E K Cycle Indicator Light The lighted bar below the clock display indicates which stage of the sanitizing cycle the SoClean is in RED when the SoClean is operating and generating activated oxygen YELLOW when the SoClean is in its 2 hour sanitizing cycle GREEN when sanitizing has been successfully completed The lighted display will turn off once the lid is lifted Display Messages Hose not present Cycle will not run This message displays during the manual mode when there is no mask hose in the SoClean the lid is not properly closed or the hose slot plug is missing or improperly seated Order filter kit This message displays after approximately 6 months of use as a reminder to order a replacement filter and check valve kit Using Your SoClean After the initial setup using your SoClean unit is extremely easy You will not need to disassemble any components to sanitize you equipment daily 1 Open the lid 15 16 Using Your SoClean continued 2 Insert your mask into the chamber al lowing its attached hose to rest in the open
6. cleaning solution The pre wash neutralizes any pre existing odors from detergents and removes any residue from the manufacturing process that could react with activated oxygen Use the pre wash whenever you hand wash your CPAP equipment Getting Started 1 Pre washing your Equipment Use of the included pre wash with a gallon of water to wash your CPAP equipment mask hose and reservoir then rinse thoroughly with clean water Note The SoClean uses no fluids in its operation The pre wash is supplied for hand washing your CPAP equipment only 2 Installing the Injection Fitting With humidifier Disconnect your CPAP hose from your CPAP machine Position the injection fitting onto the port of your reservoir allowing the smaller hose to enter into and rest on or near the bottom of the reservoir If necessary trim the injection hose if to fit in the reservoir Note If you keep water in the reservoir it is recommended to keep the end of the injection hose below the water level Getting Started continued Remove small _ injection hose first A do not insert into CPAP machine ARS S L MIIE S T NY GZ UM rri Pr Now connect your CPAP hose to the end of the injection fitting Note Different reservoirs may require different approaches to hose insertion If you have difficulty visit www BetterRestSolutions com for informatio
7. ht 2011 2013 www betterrestsolutions com is a division of Inceptus Inc SoClean is a trademark of Inceptus Inc Uxbridge MA 01569 2001 Edition 10 01 13
8. minutes am ua MANUAL MANUAL MANUAL 1 n MANUAL Setting the Clock Press the button Change the time by pushing either the El or EB button until your current time is reached By holding down the button the time moves faster Press the button once more to store your time and return to the home screen Setting the Run Time and Duration Press the button Press the or BB button to decrease or increase the number of minutes of your run time Note A run time of 5 to 10 minutes should be enough to completely sanitize your equipment ee Bo SIC X 6 Press the button again and you will be prompted to set the time of day you would like to run your SoClean Use the or WB button to reach the desired time Press the button once more to store your settings and return to the home screen Manual Mode For those times when you wish to sanitize your equipment other than during your scheduled cycle simply place your mask inside the SoClean like you normally would and press the WS button The SoClean will then operate according to your preset run time Your timer settings will not be affected As with your normal sanitizing procedure wait for the green light before removing your mask 24 Hour Clock If you prefer your clock to display in the 24 hour format military time press the BB and buttons You will then be prompted to choose either the 12 or 24 hour format
9. n on various humidifier models or contact Better Rest Solutions directly at 1 866 501 3705 Without humidifier If you are currently not using a humidifier remove the short length of black hose from the inside of the injection fitting by pulling it straight off and then attach the fitting directly to your CPAP machine Reconnect your CPAP hose to end of the injection fitting Getting Started continued La Getting Started continued 3 Power Up Plug your AC adapter into the back of the SoClean and then into a wall outlet Proceed to set your timer Your SoClean Timer amp Display Current Time Length of Cycle Cycle Start Time Manual Clock Set 9 MANUAL Sanitizing x Decrease Cycle Set Increase Sanitizing Cycle Indicator Light Your SoClean timer will allow you to completely automate your daily cleaning The SoClean comes preset to start a 7 minute cleaning cycle at 10 00 am First set the clock to match your current time You can easily change these settings by following the steps on the next page If you unplug the SoClean or experience a power loss you will need to reset the current time only The sanitizing settings will remain saved Your SoClean Timer amp Display continued 18 SIC BE SIC _ irn Set Current Time Im L Lip Set Current Time Set Run Time in minutes am wei Set Run Time in
10. pment be wet from the SoClean No The SoClean sanitizes with activated oxygen No fluids or water are used in this process 2 Is the SoClean harmful to me or the environment No The activated oxygen generator is always kept at a safe level and never reaches the outside environment 3 How do know that my SoClean is truly sanitizing After the sanitizing process has been successfully completed the cycle indicator light will shine green Your CPAP equipment will have a light clean scent 4 What if the scent the SoClean leaves is too strong for me If you have already treated your equipment with the Neutralizing Pre Wash and still feel that the scent is too strong there are a number of things you can do 1 Before wearing your mask at bedtime run your CPAP for 20 seconds to allow any residual scent to be blown out 2 Set the timer so that treatments take place earlier in the day allowing any residual scent to dissipate by nighttime 3 Reduce the treatment duration time You can cut back to as little as 5 minutes and still receive effective sanitizing 4 Sanitize your equipment every other day instead of daily 5 What if my indicator light is shining red or yellow This means that the sanitizing process is not yet complete Please wait until the light shines green to remove your CPAP equipment from the SoClean chamber See page 14 6 What if my indicator light is not shining after a scheduled cleaning time