1. L UEO MetroLED User Guide CI Models covered by this manual UFO MetroLED LW Light Wand UFO MetroLED LG L Shaped Gantry UFO MetroLED UG U Shaped Gantry UFO MetroLED FS Free Standing Gantry UFO MetroLED SP Special Extrusion Please read this manual fully before installing operating or performing maintenance on the system Universal Fibre Optics Home Place Coldstream TD12 4DT United Kingdom Tel 44 0 1890 883416 Fax 44 0 1890 883062 Issue 2 Revised 22082013 www fibreopticlighting com 1 INTRODUCTION Thank you for purchasing this UFO MetroLED lighting system Please read these instructions fully before performing any installation operation or maintenance on the system and before connecting to an electrical supply The UFO MetroLED is a fully configurable LED track lighting system which has been especially designed for ease of use and many installation environments Available in multiple configurations and with spotlight and linear lighting modules both available with a choice of 3000K or 4000K light outputs If your system requires reconfiguring with new parts please contact your UFO sales representative for advice n MetroLED Range 2 USER GUIDE Before assembly unpack the shipment and check that all component parts against the Component Parts List before commencing your build see the Component Parts Section in this User Guide 2 1 PREPARE THE 12V PSU The MetroLED flexible lig
2. eck output with Dimmer failed Check input and Renace drer output with DVM i Loose DC output wire or con Chad all connections LEDs on one track nection to that particular track not working but no MetroLED dimmer Dimmer output channel failed Replace dimmer or move overload LED Confirm by swapping output channel wire of faulty channel wires over to working channel Disconnect ve wire to over loaded track at dimmer If LED extinguishes track is overloaded Remove LED fittings until overload LED extinguishes LEDs on one track Track overloaded not working MetroLED dimmer overload LED illuminated Disconnect ve wire to overloaded track at MetroLED dimmer If LED remains illuminated replace dimmer Bad connection on rotating Inspect joint check connection LEDs on one part of Joint and ensure fully inserted fixture gantry not Open joint and inspect wire working Rotating joint failed connections if broken replace joint Bad connection on dimmer cable Check connections LEDs won t respond to remote dimmer Faulty dimmer box Replace dimmer box controls Dimmer failed Replace dimmer Poor light output on es individual LEDs LED failed Replace individual LED Please complete troubleshooting procedures before returning unit to us n MetroLED Range MetroLED dimmer faulty 4 LED SPECIFICATIONS Spotlight Spotlight Linear Light 45mm Linear Light 45mm Linear Light 95mm Linear Light 95mm Li
3. etroLED dimmer O Dimmer Terminal nnector Description Wire Colour ouor rommer ote From DAME CONTROL CARE Red OUTPUTTODINMER POTS CONTROLI DINNER CONTROL CABLE ORANGE OUTPUTTO DINMER POTs CONTROLZ DINNER CONTROL CABLE GREEN avec TO TRACKS F osmive TRACKPOMERCABLE RED MetroLED Dimmer Output to ins Dimmer sv DE Over Pots Tracks Load 5y DC CIC o ED UP Plug 5V Supply in here TRACK POWER CABLE DIMMER CONTROL CABLE DIMMER CONTROL MetroLED Range 2 USER GUIDE 2 7 ELECTRICAL CONNECTIONS The MetroLED Dimmer unit has two ve track outputs which are limited to 3 Amps exceeding the load on either track will cause the overloaded track to shut down and the overload indicator LED to illuminate Turn the dimming controls and check that the appropriate track dims and brightens Plug the mains plug into the electrical supply socket Switch on power the LEDs on the track will illuminate If no light is produced consult the TROUBLESHOOTING section 2 7 MAINTENANCE Please Note that a record of all maintenance MUST be kept in the table below indicating what maintenance was undertaken and when This MUST be dated for warranty purposes Universal Fibre Optics 10 3 TROUBLESHOOTING Main supply off Check supply amp reinstate Loose main plugs Check plugs no Ma Apr Or Check all connections Unit is dead no light connection output from LEDs PSU failed Ch
4. fittings are removed from the track for any reason ensure they are the correct way round when replacing See examples below Correct pins facing the right way Incorrect pins facing the wrong way Pushing LED fittings on the wrong way will irreparably damage the spring contacts Correct pins facing the right way MetroLED Range 2 6 ASSEMBLY TWIST LOCK PARTS This is a2 part assembly see photographs below Assembly apart Push assembly firmly into Base turn the top assembly so that it sits across the base as shown Push the base assembly into the track Push down and twist the upper so that the connector pins line up with assembly through 90 degrees until it the two tracks required locks onto the track as shown below NOTE Care must be taken to push the fitting firmly down so that it is fully sitting in the track extrusion If not fully inserted when twisting to lock the plastic housing may become damaged which will result in the fitting not being locked in Universal Fibre Optics DI 2 USER GUIDE 2 7 ELECTRICAL CONNECTIONS There are 3 electrical connections required before connecting the system to the mains see drawing below 1 Connect the extrusion power In connector track power cable to the MetroLED dimmer ensuring correct wire colour codes 2 Connect the dimmer box and cable to MetroLED dimmer ensuring correct wire colour codes 3 Plug the 5V DC jack plug into the input socket on the M
5. hting track system is powered from EITHER a multifunction multi voltage 4 Amp desk top Power Supply Unit OR an IEC input multi voltage boxed PSU 2 2 4A DESKTOP PSU Remove the Desk Top PSU from its box This PSU is a multi plug device catering for UK European and USA plugs 4 Select the correct plug and push it into the receptacle and press down until it clicks securely into place as shown above The plug can be removed by squeezing together the locking pins and sliding the plug out as shown below Universal Fibre Optics 2 2 USER GUIDE 2 3 6A Desk Top PSU Remove the PSU from its packing This PSU is an IEC mains lead device catering for UK European and USA plugs Plug the mains lead into the IEC socket on the PSU see below The PSU is now ready for power DO NOT CONNECT PSU TO DIMMER UNTIL METROLED TRACK SYSTEM IS FULLY ASSEMBLED AND THE DIMMER IS CONNECTED 2 4 COMPONENT PARTS MetroLED component parts are detailed below 3000K spotlight 3000K spotlight note colour coded green dot on base Patent O o Oooo Plastic infill strip Linear wash LED strip 3000K or 4000K 3000K identified on base Di MetroLED Range 2 USER GUIDE 2 4 COMPONENT PARTS MetroLED component parts are detailed below Tem Decio OOOO o Extusionendcap O O OO Left hand rotating corner static corner also available Right hand rotating corner static corner also available Corner 30m foot unthreaded screw plate Standard r
6. near Light 245mm Linear Light 245mm MetroLED Driver 3000K 0 5W 4000K 0 5W 3000K 0 4W 4000K 0 4W 3000K 0 8W 3000K 2 3W 4000K 2 3W Version 2 N A 4000K 0 8W Available in spot and LOSE flood fitting Available in spot and name flood fitting pra 80mA 160mA 300mA per Overload indication and channel shut down 460mA Universal Fibre Optics 12 4 GENERAL TECHNICAL SPECIFICATIONS Main supply voltage PSU output Min ambient temperature Max ambient temperature Power connection LED type model LED linear CRI LED linear colour temperature LED linear optical efficiency LED linear current LED spot CRI LED spot colour temperature LED spot optical efficiency LED spot current LED life sw MetroLED Range 5 NOTES Universal Fibre Optics 1 5 NOTES 6 MetroLED Range 5 NOTES Universal Fibre Optics 5 NOTES 7 MetroLED Range 5 NOTES Universal Fibre Optics 1 _ UNIVERSAL FIBRE OPTICS Universal Fibre Optics Home Place Coldstream TD12 4DT United Kingdom Tel 44 0 1890 883416 Fax 44 0 1890 883062 www fibreopticlighting com
7. ound 42mm foot with threaded lock nut Standard round 30mm foot unthreaded screw plate NOTE ROTATING ELBOWS ARE DESIGNED TO ROTATE BY APPROXIMATELY 350 ONLY A SMALL PLASTIC END STOP INSIDE THE FITTING RESTRICTS THE TURN HOWEVER IT IS POSSIBLE TO FORCE THE TURN PAST THIS END STOP WHICH WILL EVENTUALLY LEAD TO THE FLEXIBLE CONNECTOR INSIDE THE FITTING BEING DAMAGED ROTATE THESE ELBOWS WITH CARE AND DO NOT FORCE PAST THE END STOP Universal Fibre Optics 4 RECOMMENDED MINIMUM SPACING Minimum 10mm Minimum 10mm Minimum 20mm MetroLED Range 2 USER GUIDE 2 5 ASSEMBLY Slide on Parts Most MetroLED systems are shipped either fully or partly assembled All LEDs should be already fitted to the 3 track extrusion Assembly therefore will generally involve fitting together extrusions Gantry Legs will be marked Left and Right to avoid confusion CAUTION fitting legs on the wrong side of a gantry can result in a rotating joint being incorrectly turned and damaged Assemble the MetroLED system as per instructions below All plastic MetroLED components fit into the matching keyed sections of the metal extrusions either by sliding on or by twisting and locking see 2 6 Push the fitting carefully but firmly into the extrusion taking great care to avoid damaging adjacent LEDs Make sure the plastic fitting is pushed fully home Universal Fibre Optics 6 2 USER GUIDE 2 5 ASSEMBLY If LED slide on