1. Upper air inlet Exhaust air outlet Lower air inlet Cable storage Drainage point with water stopper F ZA AA Water container Exhaust hose AY lt Active carbon filter My Remote control with LCD f Slide bar connector Telescopic slide bar Air outlet Control panel Carrying handle Caster wheels AUN D ON Du CONTROL PANEL Fan ON UP Clock OFF Timer DISPLAY Cooling Gr Sleep mode Fan speed Clock timer Temperature Timer settings INSTALLATION WARNING Before using the air conditioner it should be left in an upright position for at least 2 hours This unit can easily be moved from one room to another In doing so keep this in mind Ensure that the unit is positioned upright on a level surface and 50 cm away from obstacles To place the loose filters in the filter holder e Take the filter holder out of the air conditioner e Release the filter fixer and place the active carbon filter black in the filter holder e Place the filter fixer back in the holder e Place the filter holder back in the air conditioner Do not operate the unit inside the bathroom shower or in any other very humid environment Connect the hose to the unit by turning it clockwise at least 5 turns Similarly connect the hose to the slide bar connector as far as possible Place the telescopic slide bar in the open window or door and adjust the length to fillas much
2. or O to adjust the hour e Press the button briefly again the 2 right digits of the 4 digits are flashing e Press or to adjust the minutes of the clock in intervals of 5 minutes The timer is set After 10 seconds the time display returns Programming the timer for ON when the unit is OFF e Perform the standard steps as described above The circular time scale will be on between the ON programmed times until 24 00 The flashing bar on the time scale indicates the real time and moves a segment ahead every 30 minutes until it reaches the ON timer time then the black segments in the circular time scale will disappear OFF ON 5 Timer example Programming the timer for OFF when the unit is RUNNING Perform the standard steps as described above The circular time scale will be on between the present time to the OFF programmed time The flashing bar on the time scale indicates the real time and moves a segment ahead every 30 minutes until it reaches the OFF timer time then the black segments in the circular time scale will disappear Repeat OFF and ON Programming the timer for repeat OFF and ON when the unit is RUNNING Perform the standard steps as described above Repeat the above procedure while the digits are still flashing for setting the ON The circular time scale will be ON between 00 00 to the time set with the timer to OFF and from that time until 24 00 The flashing bar on the time scale ind
3. 220 240 50 1 Compressor model rotary Fan speeds 3 2 1 turbo Thermostatic range C 18 32 Refrigerant charge type g R410A 460 R410A 660 Dimensions w x h x d mm 555 x 800 x 455 Net weight kg 31 5 32 8 34 2 1 measured under enthalpy method with tolerance The above figures are subject to modifications without prior notice For greater precision please refer to the Reminder Waste electrical products must not be disposed of with household waste This product should be taken to your local recycling centre for safe treatment N AMCOR
4. the internal water container When the internal water container is full the backlight on teh LCD display flashes the unit will switch off automatically To empty the water container do the following e Switch off the unit and remove the plug from the wall socket 4 Do not move the unit Doing this can result in water leakage damaging your floor or carpet Place the water container on the floor underneath the permanent Za drainage point a Remove the water stopper and rubber plug from the drain and let the water run out The water container has to be emptied several times before all water will be drained ca 1 5 litres Replace the rubber plug and water stopper put the plug into the wall socket and switch the unit on The warning signal should be off NOTE When the air conditioner is in use under normal circumstances the condensed water will evaporate and then be discharged through the hot air outlet hose CONTINUOUS DRAINAGE Switch off the unit and remove the plug from the mains Remove the water stopper and rubber plug e Connect a drain tube 20 mm inner dimension onto the water outlet and extend with extra water tube if needed e Place the other end in a normal drain Make sure that the tube is free from twists and bends The tube must decline over its entire length WARNING First of all switch off the unit and remove the plug from the wall socket Clean the housing
5. with a soft damp cloth Never use aggressive chemicals petrol detergents or other cleansing solutions Clean the screen filter regularly with a vacuum cleaner See also air filter section NOTE Never use the air conditioner without the screen filter TROUBLE SHOOTING Never try to repair or dismantle the air conditioner yourself Incompetent repairs result in loss of warranty and can endanger the user and the property Problem Cause Solution The air No power supply Connect to a functioning outlet and switch on conditioner does js the LCD light flashing Empty the internal water container not function 3 Timerfunction is active Deactivate TIMER function The air In direct sunlight Close curtains conditioner does Windows or doors open many Close doors and windows place an extra air disease to people or a heat source in the room conditioner erform P Dirty filter Clean or replace the filter s Air inlet or air outlet blocked Remove the blockage Room temperature lower than the Change temperature selection selected value The unit is noisy Unit stands uneven Place on an even solid surface less vibrations The compressor The overheat protection is probably Wait 3 minutes until the temperature has does not work activated decreased then turn on the unit again The remote Distance too great Make sure the remote control is correctly control does not Remote
6. WY AMCOR ENGLISH INSTRUCTION MANUAL 0 Q gt re m A Q g J Q m 2 CE hours 9KE H 410 12KE H 410 15KE H 410 PLUS HEATER VERSIONS THANK YOU Thank you for choosing this innovative Amcor air conditioner We suggest that you keep this manual in a safe place for future reference It describes the many benefits and advanced features this unique product has to offer Before you use your new air conditioner you should carefully read these instructions to maximise this product s performance For over 50 years Amcor has specialised in complete indoor environmental control manufacturing and marketing dehumidifiers portable air conditioners coolers air purifiers ionisers and aroma therapy scent diffusers These world class products incorporate the latest technological developments ELECTRIC CONNECTION For your safety please read the following information Warning This appliance must be earthed The appliance is supplied with a moulded 13 amp 3 pin mains plug fitted with a 13 amp fuse Should the fuse require replacement it must be replaced with a fuse rated at 13 amp and approved to BS1362 The plug contains a removable fuse cover that must be refitted when the fuse is replaced In the event of the fuse cover being lost or damaged the plug must not be used until a replacement cover has been obtained If the moulded mains plug is unsuitable for the socket outlet in your home or is
7. an speed LOW e Press the J button to operate the sleep mode Press the J button again in order to cancel the sleep mode The set temperature will increase 1 C after 1 hour and a further 1 C after 2 hours No FAN mode under SLEEP mode operation Dehumidification If the unit will be used mainly as a dehumidifier just let the warm air return in the room Continuous drainage see separate chapter is then necessary and more efficient AIR FILTER This air conditioner is equipped with two filter sets 1 A multi layer filter in the upper air inlet to clean the circulated room air which includes a A screen filter to remove dust particles b An active carbon filter to remove odours 2 A screen filter in the lower air inlet to remove dust particles NOTE The active carbon filter is delivered in a plastic packaging Don t forget to install the filter The filter holder on the rear of the unit can be opened The active carbon filter can be installed or removed The screen filter is part of the filter holder see illustration Cleaning the air filters a The screen filters in the upper and lower air inlet should be cleaned regularly by rinsing the m under running water b The active carbon filter can be cleaned with a vacuum cleaner when dusty but has to be changed every 3 months Filter installation 1 2 3 e Slide out the filter holder from the unit e Separate the filter fixer from the filter holder see fig 1
8. control signal not detected aimed at the control panel function by the control panel The batteries are drained Replace the batteries To correct problems that have not been described in the table and or if the recommended solutions fail to solve the problem contact an authorized service centre _ Empty the internal water container Clean the screen filter Remove active carbon filter Remove active carbon filter before end of season storage and install new filter at the beginning of the new season The old filter can be disposed of in the Non biological rubbish container Replacement filter packages are available from Amcor Put the unit in Fan Only mode for a few hours to ensure that the inside becomes completely dry Store the cable as shown STORAGE Protect the unit against dust and store in a dry place not accessible to children TECHNICAL DATA Mode PCMA 9KE 410 PCMA12KE 410 PCMA15KE 410 PCMA 9KEH 410 IPCMA12KEH 410 IPCMA15KEH 410 2 measured conform EN 14511 rating label placed on the product BTU 9000 1200 15000 Cooling capacity 1 kW 2 6 3 5 44 Codin en BTU h 7500 9400 11300 siete lt kw 2 2 275 33 Heating capacity 2 BTU h 7500 9400 11130 kW 2 2 2 75 3 25 Power consumption _ cooling kW 0 8 1 1 1 5 heating EH only 0 7 1 0 1 4 Current cooling A 4 5 7 heat pump EH only 3 1 4 4 6 2 Mains V Hz PH
9. e Remove the active carbon filter black from its plastic bag Insert the active carbon filter into the filter holder see fig 2 Fix the filter by reassembling the fixer into the filter holder see fig 3 NOTE Remove active carbon filter before seasonal storage and install new filters at the beginning of the new season The old filters can be disposed in the Non biological garbage container Replacement filter packages are available directly from Amcor To run the unit without active carbon filter does not do any harm to the air conditioner In this case odours and unhealthy dust are not removed from the circulated air The screen filter must always be used REMOTE CONTROL The unit responds to all signals that are sent by the remote control There will be a beep sound from the unit after receiving the signal The operation of the unit by remote control is almost identical to the operation by the circular control panel The only exception is the clock function o Instead of the button for setting the actual time and for programming the as timer there are 3 push buttons on the remote control as follows an for setting the actual time WR THER TIMER ON for programming the time when the unit is ON o a TIMER OFF for programming the time when the unit is OFF 2 c ii p A EMPTYING THE INTERNAL WATER CONTAINER Under high humidity conditions it may be necessary to empty
10. icates the real time and moves a segment ahead every 30 minutes The unit will operate daily according to the timer setting Repeat ON and OFF Programming the timer for repeat ON and OFF when the unit is NOT RUNNING Perform the standard steps as described above Repeat the above procedure while the digits are still flashing for setting the OFF The circular time scale will be OFF between 00 00 to the time set with the timer to ON and from that time until 24 00 The flashing bar on the time scale indicates the real time and moves a segment ahead every 30 minutes The unit will operate daily according to the timer setting After a power failure or after the unit has been unplugged you will have to program the timer settings again Cancelling the timer function In order to cancel the timer programming press the button momentarily then it will return to the time display The daily mode will be cancelled as well The black segments in the circular time scale will disappear Air flow Direct the air flow by adjusting the grill on top of the air conditioner Move the grill by pushing or pulling in the middle see illustration This will avoid uneven positioning of the grill Adjusting the air flow is as also possible by moving the direction of the vertical louvres Sleep mode The sleep mode function adjusts the set temperature of the unit to the thermal needs of the body falling asleep as follow e Default f
11. mersing it in water Do not insert any object into the opening of the air conditioner Disconnect it from the mains before cleaning the unit or any of its components Never connect the unit to an electrical outlet using an extension cord If an outlet is not available one should be installed by a licensed electrician Any service other than regular cleaning or filter replacement should be performed by an authorized service representative Failure to do so could result in a loss of warranty A damaged supply cord should be replaced by the manufacturer its service agent or a qualified person in order to avoid a hazard WARNING e Never operate this appliance if it has a damaged cord or plug Do not lead the cord over sharp edges Don t lift or move by pushing the air conditioner at the rear but always at the front side e Keep a minimal 0 5 m safety distance between the appliance with the electrical heater and any inflammable surface Do not use a damaged cable Keep out of reach of children Do not place unevenly Do not place near a heat source Do not repair Do not spill d Do not place in front of an open window Do not immerse in water i Do not use an extension cord j Do not clamp or bend the cable h Do not bring in contact with chemicals Do not insert anything amo annaows iE SS TF Ba oe PARTS
12. open space as possible Put the slide bar connector in the opening in the telescopic slide bar Close the window or door as much as possible to prevent outside air entering the room Ensure that the slide bar connector has a free flow outside i a 50cm Important The flexible exhaust hose can be extended from 660 to 2000 mm for mounting This length has been designed especially according to the specifications of the air conditioner Do not use an extension or exchange for a different hose as that may lead to malfunctioning The exhaust air must flow freely any blockage can lead to overheating of the air conditioner Take care to prevent any sharp bow or bend in the exhaust OPERATION ON OFF Press to switch the unit on or off A buzzer will beep and the LCD will display 12 00 o clock as default Setting the clock Press the button for 3 seconds to set the clock The 2 left digits of the 4 digits on the LCD display will flash Press a or to adjust the hour Press CO momentarily the 2 right digits of the 4 digits will flash Press or to adjust the minutes of the clock Press the button for 3 seconds again to activate the clock Setting the temperature If you want to change the set temperature press or to set the temperature The 2 digit display will indicate the set temperature Note Reaching the set temperature depends on the room and outdoor climatic conditions Mode switch Pres
13. removed for any other reason then the fuse should be removed and the cut off plug disposed of safely to prevent the hazard of electric shock There is a danger of electric shock if the cut off plug is inserted into any 13 amp socket outlet Important The wires in the mains lead on this appliance are coloured in How to wire a 13 amp plug accordance with the following code Green and Yellow Earth Blue Neutral Brown Live As the colours may not correspond with the markings identifying the terminals in your plug proceed as follows The green and yellow wire must be connected to the terminal in the plug which is marked with the letter E or with the earth symbol or coloured green and yellow Cord clamp The blue wire must be connected to the terminal marked N or coloured black The brown wire must be connected to the terminal marked L or coloured red E SAFETY INSTRUCTIONS IMPORTANT e The unit is designed for indoor operation Rating This unit must be connected to a 220 240 V 50 Hz earthed outlet The installation must be in accordance with regulations of the country where the unit is used If you are in any doubt about the electrical installation have it checked and if necessary modified by a qualified electrician e The air conditioner is safe However as with other electrical appliances use it with care Keep out of the reach of children Do not clean the air conditioner by spraying it or im
14. s the button successively until the icon representing the desired mode is appearing gt Cool gt Fan gt Heat gt etc On the LCD display you will see Cooling EOR Fan only Heat Each time the unit starts it starts operating in cool mode with a set temperature of 22 C The fan speed will be selected automatically Heat mode is only available on EH models Fan speed If you prefer a constant fan speed instead of the auto fan speed press the button successively the fan icon on the LCD display will rotate accordingly e Fast for the turbo speed e Normal for the medium speed Slow for the slow speed e Alternating for the auto fan speed in the cooling mode only Switching LCD backlight ON OFF If you prefer to switch the LCD backlight off push the and buttons at the same time After blinking twice the backlihgt will be switched off after 3 sec e By pushing any button on the control panel the backlight will switch on again Heat pump With the mode switch select X set the desired temperature and the unit will heat unit this temperature is reached Fan speed is selected automatically Do not place the unit near anything that could catch fire or be scorched Do not obstruct the air outlet Timer For all of the following TIMER programming proceed firstly with these standard steps e Press the button briefly the 2 left digits of the 4 digits on the LCD display are flashing e Press