Home
eMOTION Powercap micro - Massoth Elektronik GmbH
Contents
1. Service Support MASSOTH warrants this product against defects in materials and workmanship for one year from the original date of purchase Other countries might have different legal warranty situations Normal wear and tear consumer modi fications as well as improper use or installation are not covered Peripheral component damage is not covered by this warranty Valid warranty claims will be serviced without charge within the warranty period For warranty service please return the product to you dealer or send it directly to the manufacturer Return shipping charges are not cov ered by MASSOTH Please include your proof of purchase with the returned goods Auf unserer Internetseite finden Sie die jeweils aktuellen Brosch ren Pro duktinformationen Dokumentation und Softwareprodukte rund um MASSOTH Produkte Irrt mer und nderungen vorbehalten 4 1 Hotline Serviceanfragen richten Sie bitte an Massoth Elektronik GmbH Mo 14 00 17 30 sowie Do 8 00 12 00 FON 49 0 6151 35077 38 FAX 49 0 6151 35077 44 hotline massoth de C Please check our web site for up to date brochures product information docu mentation and software updates Errors and changes excepted 4 1 Hotline For technical support contact Massoth Elektronik GmbH Germany Mo 2 00 5 30 p m Thu 8 00 12 00 a m FON 49 0 6151 3507738 FAX 49 0 6151 3507744 hotline massoth de Dieses Produkt entspricht den CE Konformit tsrichtlinien
2. f r elektrische Kleinger te in der aktuellen Fassung This unit conforms to the CE Standards Dieses Produkt ist nach den aktuellen EG Richtlinien 2 RoHS umgangssprachlich bleifrei hergestellt und damit RoHS konform This unit is manufactured according to the latest EG Standards for lead free manufacturing conforming to RoHS Standard wy Entsorgen Sie das Produkt nicht im Hausm ll IX Nutzen Sie bitte den daf r vorgesehenen Elektroschrott C3 Please dispose of according to your State regulations Werfen Sie das Produkt nicht in offenes Feuer oder durch Hitze entflammbare Brennstoffe Do not dispose of in open fire 11 GEHT Community QUALITY Massoth Elektronik GmbH E MADE IN Frankensteiner Str 28 D 64342 Seeheim Germany FON 49 0 6151 35077 0 FAX 49 0 6151 35077 44 a GERMANY email info massoth de www massoth de re D g 8151601_06_2012_ML
3. Bei Decodern ohne Steuerausgang BC Decoders without a buffer control con verbinden sie das wei e Kabel ber den nection can still be equipped with a buf beiliegenden Schalter mit dem schwar fer using the enclosed switch to connect zen Kabel GND Abbildung 4 5 In the white cable to the black one GND diesem fall muss bei der Programmie see illustration 4 5 In this case it is rung des Decoders die Ladefunktion required to switch off the charging func ber den Schalter ausgeschaltet werden tion in order to program the decoder f Ja z weiss an Schalter Rot an Dec white to switch red to Dec schwarz an Dec und Schalter black to Dec and switch Abbildung 4 Beispiel f r Anschluss an LGB 55021 L55021 Illustration 4 Connecting the Powercap to a LGB 55021 decoder 155021 Rot red eMOTION Schwarz black Powercap Weiss white Dekoder S Dekoder II Abbildung 5 Beispiel f r Anschluss an Fremddecoder ohne BC Illustration 5 Connecting the Powercap to a foreign decoder without BC Im Analogbetrieb mit Decoder kann das wei e Kabel auch direkt mit dem Schwarzen verbunden werden Beim Programmieren und Auslesen des De coders kann dies dann aber zu Fehlern f hren da Lade und Entladevorg nge den Programmiervorgang st ren k n nen Die Verwendung des Schalters wird deshalb prinzipiell empfohlen 2 1 Digitalbetrieb Der Powercap l dt sich w hrend des Betriebes automati
4. Zerst rung und kann Folgesch den an anderen Komponenten hervorrufen Der Powercap ist f r Gartenbahnloks mit einer maximalen Stromaufnah me von 1A oder f r Soundmodule konzipiert Das Modul darf nur f r die in der An leitung genannten Funktionen genutzt werden Eine anderweitige Verwen dung kann zur Zerst rung f hren Die Schaltung kann im Betrieb hei werden Bitte nicht ber hren Dieses Produkt ist kein Spielzeug 1 1 Warning Notes Please install this product closely following the documented wiring diagrams A connection error may result in product damage or loss e g mix up of red and black A faulty installation or incorrect decoder setting can result in uncon trolled locomotive operation as long as the Powercap is charged Massoth is not liable for resultant damages The Powercap must never be con nected directly to the track power This results in product damage and failure of other components The Powercap is especially designed for G scale locomotives or sound modules with a maximum power consumption of 1A The Powercap may be used only as stated in this manual Any other use may lead to destruction The circuitry may heat up during operation Do not touch This product is not a toy 1 2 Funktionsumfang Der Powercap micro dient zum berbr cken von kurzzeitigen Unterbrechungen der Gleisspannung bei Gartenbahn lokomotiven oder zur Pufferung von Ger uschen bei Analogbetrieb im Still stan
5. ance During programming procedures the Powercap is automatically deactivated if the decoder supports a buffer control con nection Otherwise the Powercap can be operated using the enclosed switch to deactivate the charging The flexible 3 piece design makes installation and fitting very easy and suitable for smaller G scale locomotives 1 3 Scope of Supply e Powercap micro three piece e slide switch e manual 2 Anschluss Der Powercap micro ist f r den Anschluss an Massoth eMOTION Decoder oder Soundmodule optimiert Er kann auch an jeden anderen Digital decoder angeschlossen werden der Anschl sse f r Decoder 22V und Decoder GND hinter dem Gleichrich ter zur Verf gung stellt Abbildung 1 2 e Das rote Kabel verbinden Sie mit Decoder 22V des Decoders e Das schwarze Kabel verbinden Sie mit Decoder GND des Decoders e Das wei e Kabel verbinden sie mit BC Buffer Control des Decoders Hinweise zum BC Anschluss finden sie in der jeweiligen Beschreibung des Decoders oder einer Lokbasiselektronik mit PluG Schnittstelle Rot red eMOTION Schwarz black Powercap Weiss white 2 Installation The Powercap micro is especially designed to connect with eMOTION decoders series by Massoth Neverthe less it can be connected to any other de coder if it offers the terminals Decoder 22V and Decoder GND behind the rectifier see illustration 1 2 e The r
6. d Der Motor und Sonderfunktionen werden w hrend dieser Unterbrechung aus dem Speicher versorgt Somit k nnen Lokomotiven problemlos ber Weichenherzst cke oder Isolierstellen fahren ohne stehen zu bleiben Die Dauer der Pufferung betr gt je nach angeschlossener Last Geschwindigkeit und Ladezustand bis zu 30 Sekunden Durch eine integrierte Steuerung wird der Puffer immer optimal an das aktuelle Betriebsverhalten angepasst Bei der Programmierung des Decoders wird der Puffer automatisch komplett abgeschaltet sofern die Elektronik das unterst tzt Ansonsten kann der Puffer mit dem mitgelieferten Schiebeschalter abgeschaltet werden Aufgrund der 3 teiligen Bauform l sst sich der Puffer auch in kleinere Gartenbahnfahrzeuge verbauen 1 3 Lieferumfang e Powercap Micro 3 teilig e Schiebeschalter e Bedienungsanleitung 1 2 Features The Powercap micro is used to compen sate short term track power interrup tions for G scale locomotives as well as standing sound operation in analog mode The motor and the locomotive functions are operated with the Power cap during a track power interruption Locomotives can easily cross switch point frogs or insulated track sections e g dirty track sections without stop ping The buffering time depends on the connected load driving speed and charge level and lasts up to 30 seconds The integrated electronic control always adapts the Powercap state to the cur rent operating perform
7. eMOTION Powercap micro 8151601 Inhaltsverzeichnis Einleitende Information Warnhinweise Funktionsumfang Lieferumfang ae Anschl ssen eine Digitalbetrieb Analogbetrieb Br Technische Daten Garantie Reparatur Kundendienst Hotline sessar 1 Einleitende Information Sehr geehrte Kunden wir empfeh len die Produktdokumentation und vor allem auch die Warnhinweise vor der Inbetriebnahme gr ndlich zu lesen und diese zu Beachten Table of contents Introduction eisen Wanin Note S russ Features Scope of supply is Stal AO Wess sts mas Digital Operation Analog Operation 1 Introduction Dear customer we strongly recom mend that you read this manual and the warning notes thoroughly before installing and operating this product 1 1 Warnhinweise Bauen Sie die Elektronik sorgf ltig nach den Anschlusspl nen ein Wer den beim Einbau Kabel vertauscht oder Kabel kurzgeschlossen z B Rot Schwarz kann dies zur Zerst rung der Elektronik f hren Ein fehlerhafter Anschluss oder eine unsachgem e Programmierung des Decoders kann dazu f hren das die Lok bei geladenem Powercap unkontrolliert weiterf hrt Die Firma Massoth Elektronik GmbH bernimmt f r die dadurch entstandenen Sch den keine Haftung Der Powercap darf niemals direkt an die Gleisspannung angeschlossen werden Dies f hrt zur
8. ed cable connects to Decoders 22V e The black cable connects to Decoder GND e The white cable connects to Buffer Control BC on the decoder Detailed information on the BC function ality can be found in the manual of the respective decoder or PluG interface S Decoder aS Decoder A Abbildung 1 Beispiel f r Anschluss an Massoth eMOTION Decoder mit BC Illustration 1 Connecting the Powercap to a Massoth eMOTION Decoder with BC rot an red to Dec schwarz an black to Dec J wei an white to BC Abbildung 2 Beispiel f r Anschluss an eMOTION XLS Decoder mit BC Illustration 2 Connecting the Powercap to aeMOTION XLS Decoder with BC Bei lteren Decodern kann BC auf Older decoders may not show the buffer einem Funktionsausgang des Decoders control connection BC but can offer it liegen z B A5 beim eMOTION XL on a function connection e g A5 on the Abbildung 3 eMOTION XL see illustration 3 Rot red VS aN SI Decoder IS Decoder ES lt T A4 A5 bei eMOTION Dec ohne BC A4 A5 on eMOTION Dec without BC eMOTION Schwarz black Powercap micro i Weiss white Abbildung 3 Beispiel f r Anschluss an Massoth eMOTION Decoder ohne BC Illustration 3 Connecting the Powercap to a Massoth eMOTION Decoder without BC Anschluss CV Wert M L XL XXL A5 CV118 31 8FL XLS alt ohne BC A4 CV116 31 old without BC
9. i schlagartigem Spannungsverlust z B in einer Trennstelle vor einem rotem Signal optimiert werden Pr fen sie anhand der Anleitung ihres Decoders ob und wie diese Funktion unterst tzt wird Das Laden des Puffers erfolgt abh ngig von der H he der anliegenden Gleis spannung Je h her die Spannung am Gleis ist umso st rker wird der Puffer geladen Der Puffer eignet sich auch zur Wieder gabe von Standger uschen bei Sound modulen wenn das Fahrzeug stromlos abgestellt wird Pr fen sie auch hierzu die Anleitung des Soundmoduls zur n tigen Einstellung e Deactivate analog operation with CV 29 bit 2 value 0 Please check the correct decoder setting corresponding to the respective manual Some decoders may offer a buffer timer to set the maximum buffering time This is helpful in case of an emergency stop as otherwise the locomotive will run indefinitely until the buffer is empty 2 2 Analog Operation In analog operation decoder required the Powercap can support a soft braking behavior when there is an abrupt loss of power Please check your decoders manual if analog braking is supported and how it can be set The charging behavior of the Powercap depends on the applied track voltage level The higher the voltage on the track the stronger and faster the buffer is loaded The Powercap also supports the operation of a standing sound when the locomotive is shut down Please check the manual of your decoder or s
10. ound module in order to adjust or activate this function 3 Technische Daten e Betriebsspannung 6 24V DC e Maximaler Ladestrom 500mA bei 22V Gleisspannung e Eigenverbrauch ca 10mA e Maximale Ausgangsspannung 18V bei voller Ladung e Maximale Stromabgabe 1A e Ladezeit ca 45 Sekunden bei vollst ndiger Entladung 22V konform zu RailCommunity Norm RCN 530 4 Garantie Reparatur Kundendienst MASSOTH gew hrt die Fehlerfreiheit dieses Produkts f r ein Jahr Die gesetz lichen Regelungen k nnen in einzelnen L ndern abweichen Verschlei teile sind von der Garantieleistung ausgeschlos sen Berechtigte Beanstandungen wer den kostenlos behoben F r Reparatur oder Serviceleistungen bergeben Sie das Produkt bitte Ihrem Fachh ndler oder senden es direkt an den Hersteller Unfrei zur ckgesendete Sendungen werden nicht angenommen Eine Kopie des Kaufbelegs wird vorausgesetzt F r Sch den durch unsachgem e Behandlung oder Fremdeingriff oder Ver nderung des Produkts besteht kein Garantieanspruch Der Anspruch auf Serviceleistungen erlischt unwiderruf lich 10 3 Technical specifications e Operating voltage 6 24V DC e Maximum charging current 500mA at 22V track voltage e Self Consumption 10mA e Maximum output voltage 18V at full charge e Maximum output current 1A e charging time ca 45 Seconds at total discharge 22V compliant with RailCommunity standard RCN 530 4 Warranty
11. sch auf Bei einer Spannungsunterbrechung auf dem Gleis versorgt der Speicher den Deco der ebenfalls automatisch mit Energie Der Analogbetrieb des Decoders muss unbedingt gesperrt werden Der Decoder wird sonst den Puffer f lschlicherweise als analoge Gleisspannung erkennen Die Lok kann hierdurch bei Unterbre chungen ihre Fahrtrichtung ndern The white cable may be connected directly to the black cable for analog operation mode only decoder required Programming and reading the decoder settings will lead to errors since loading and unloading procedures will interfere with the DCC operation It is therefore strongly recommended to use the enclosed switch 2 1 Digital Operation The Powercap is charged automatically during normal operation It will feed the decoder in case of a track power loss immediately The analog operation functionality needs to be switched off in the decoder Otherwise the decoder will recognize the buffer as analog track power and may result in uncontrolled locomotive operation change of direc tion etc e Analogbetrieb sperren mit CV 29 Bit 2 Wert 0 berpr fen Sie die richtige Einstellung bitte anhand Ihrer Decoderanleitung Bei einigen Decodern kann zus tzlich die maximale Pufferdauer eingestellt werden Damit kann die Lok z B bei Notaus der Zentrale nicht unbegrenzt weiterfahren 2 2 Analogbetrieb Im Analogbetrieb mit Lokdecoder kann ber den Puffer das Bremsverhalten be