1. 0 Options are Prt Pr Prt Co and Prt St If Prt Co TIE is chosen as the print mode PC will be automatically selected as the external devices O Prt rr manual print Deb r Fr E L A continuous print Prt 5t stable printing the weight of weighted articles should be more than 9 divisions Weighted articles should be removed and the scale goes back to zero before print out the next record 10 Press key MC CK to select external devices GELG Options are AH TDP ZEBRA TP SH EZ and PC PC 11 Press MR to switch On or OFF RTC function GELG ree OFF 12 When setting is completed press key ZERO to save and return to weighing mode JCL 11 8 Serial Interface lf external interface is needed please select the proper two in one board first which integrates RTC time display RS 232 and relay weight checking functional module onto one circuit board Only when this board is adopted the three functions can be enabled 8 1 RS 232 Connector RS2ZS2 RELAY 8 2 Single Option 1 RS 232 RTC Relay AH TDP ZEBRA TP SH EZ printer 2 RS 232 RTC Relay LED Light Tower Applicable to the quality control of the factory product quantity or weight and that of the total production line 3 RS 232 RTC Relay Computer 8 3 RS 232 Output Format Baud Rate 2400 4800 gt 9600 Data Bit 8 Parity gt N None Stop Bit 1 Code ASCII Bit Format JCL 12 Data Format Example GW 2
2. to confirm 7 Press key SMPL to save and then press key ZERO to return to the weighing mode 6 2 Linear Calibration 1 Press and hold key TARE while powering on fog the scale 2 Again press key gi enter zero point 7m pase Td Pd calibration mode with LIJI LI flashing on the weight screen M 3 Wait till LIZ J appears and flashes on weight window put weights of 1 3 of full load on e g 15k model 1 3 of full load is 5kg m J 4 Wait till t L appears and flashes on total weight screen put weights of 2 3 of full load on for 15k model 2 3 of full load is 10kg 5 Wait till LUM I appears and flashes on total weight screen put weights of full load on for 15k model full load is 15kg IEE f1 flashing and then take 6 The calibration Procedure is finished with a symbol of 4 away the weights 7 Press key TARE to return to weighing mode JCL 9 7 Setting Mode 1 Turn on the power while pressing key ZERO and setting mode starts Note The following Steps 2 11 do not require to operate in order 3 Press numeric key Oto shift backlight modes Options are On OFF and OnOFF anor Auto on with items greater than 9 divisions placed on the pan rr AFF No backlight on Backlight 4 Press numeric key 2 to set the level as in which the stable indication turns on filtering The lower the setting the faster stabilization time 5 Pr
3. dealer if you have complaints or if parts are missing The package should contain e Sc de body e User manual e Stainless steel and plastic weighing pans e Wire power cord 3 2 Installing Components 1 Before using the scale remove the shipping protection screw rotate counterclockwise which located underneath the scale and cork the plug buckle Note the JCL 30K model was shipped without the shipping protection screw 2 Cover the weighing pans on the scale body properly 3 3 Leveling the Scale To compensate for small irregularities or inclinations at the location the scale can be leveled The scale is equipped with a level indicator at the front panel Adjust the leveling feet until the air bubble in the indicator is centered as shown Note The scale should be leveled each time its location is changed JCL 1 4 Product Introduction 1 Leveler 3 RS 232 interface 2 Leveling foot 4 Plastic weighing pan 5 Stainless Steel weighing pan 6 On Off Switch 7 Two stage Switch 8 Power socket 9 Transport protection screw 10 Plug buckle 4 1 Specifications amp General Features Specifications Model JCL 1 5K JCL 3K JCL 6K JCL 7 5K JCL 15K JCL 30K Weighing units g amp lb kg amp lb Display 3 backlit LCD displays 6 5 6 Digits 294X228X13 5mm Power supply AC 110V 220V AC 10 or rechargeable battery 6V 4A JCL 2 gt E C General Features A D covered by aluminium plate prevent
4. PCB from static and moisture Tare Preset Tare auto zero tracking Automatic counting accuracy improvement ACAI for enhanced counting accuracy HI OK LO quantity checking function Stainless steel weighing pan Weighing platter easy to disassemble with anti cockroach design Dust proof PVC cover Low battery and charging status indication Accumulation of weight and quantity max 99 pieces Single point and linear calibration available Auto shut off for power saving 4 2 Front Panel 4 2 1 Display 15 1 Low battery indication 2 lt gt Tare or Preset Tare indication 3 O Center of Zero indication The zeroing range is 2 of weighing capacity 4 Charge Lamp JCL 5 Leveler 6 HI Lamp ON Indicating parameter item Lin is selected when setting buzz sounds See 5 Function Setting setting buzz sounds OK Lamp ON Indicating parameter item or AA is selected when setting buzz sounds LOW Lamp ON Indicating parameter item Lo is selected when setting buzz sounds 7 PRESET TARE Symbol VY points at PRESET TARE when Tare value entered via numeric keys 8 NET Net weight Gross weight minus Tare Symbol Y points at NET when TARE or PRESET TARE action is done 9 STABLE Stable indication Symbol dd appears at the top of STABLE when scale is in stable condition 10 ACAI Symbol Y points at ACAI when the average unit weight is c
5. Upper amp Lower Quantity Limit Checking 1 Under the weighing mode press and hold key 7 rl LA MC CK to initial upper lower limits setting 4 he is blinking 2 Use numeric keys to set the upper lower Limits ar ave Key e is to save upper limit value and advance to the lower limit setting 3 When setting is completed again press key MC CK to save and return to weighing and checking mode 4 To cancel checking action long Press key MC CK then press key e twice Checking rls action is cancelled with LE displays momentarily before the screen go back to zero mode 5 2 2 Entering a Known Unit Weight 1 Under the weighing mode use the numeric keys I S ma ma C3 My Mo CI Cc cS ma OF CD C m f c gt C gt 8 Co together with key e to input unit weight value and then press UWS 2 Put the article on the weighing pan the scale starts counting Note Y points at UW when entered unit weight is lower than 4 5 of scale division 5 2 3 Sample Counting amp ACAI 1 Place samples onto the weighing pan Or into a tared container and input the quantity with numeric keys wn ere J m 2 Press key SMPL The unit weight is calculated 44999 ca co Cc a with Symbol Y Pointing at ACAI Note e The larger the sample size the more accurate unit weight eSymbol points at SMPL when calculated unit weight is lower than 4 5 of scale divisi
6. 2352 kg U W 0 5352 g pcs Total 41 76 pcs Ib am wil te te 0 vj iwj fret ol ple s er F Tl ojt aj l l p e fs cr tr Example GW 2 2352 Ib U W 0 5352 lb pcs Total 4pcs G GROSS N NET 9 Troubleshooting and Error Message Error message Problems solutions Initial zero point exceeds 1 To check whether there are other alien rticl n th n rem h 30 take 30 as reference articles on the scale pan remove those articles 2 LOAD CELL failure which requires to be basis changed or to contact our Service Higher or lower than A D 1 Check whether it is A D failure if yes please resolution range replace AD 2 LOAD CELL failure replacement is required or contact our Service JCL 13 j r J EEPROM Chksum failure Re sold EEPROM or contact our Service err l The weighed articles are Do not load the item exceeds the maximum overload tolerance The accumulated number No more accumulation of weighments total count or weight exceeds display The quantity of weighed articles exceeds display range when the scale is under unit weight entering or sampling mode Low battery Recharge the battery The scale can be used while it is recharging JCL 14 JCL 15
7. Table of Contents Des MEE OCUICHON cescccndsee erscaterugeta E A 1 2s od 164 010 g ee ees nn eae een ee nee eae een eee ere ae ee er eee ee 1 3 Before Using the Product 3 Unpacking and GHECKING sas cssccme sacl crs heaws ee clan ae hee a oe aaa 1 3 2 Installing COMPONENTS erener crevasse dicdehimeeersadaeerid EE 1 OS HEVelINO ING SCale aidin aa i 1 4 Product Introduction 4 1 Specifications amp General Features cc cece cece cece ence eee e tence seat eeaeeeseeesaeeegaeeaas 2 4 2 Front Panel Ae VIS DIAY onion cern aetdeoiadianlentael en mainiaaiaeteaundeadintmeteuemiars E 3 4 2 2 WCyV DO AIG irnia EE EEEE E O edd lecenou sauce ih dhaa de een alana 4 A 3 PF OWE SUDO aeea E EE mendeose steamed eee ccaraataeie 5 5 Operation 5 1 Basic Weighing yale WAN Peer eo ee een en ea mec S a ne ene Re ae ee eee 6 5 1 2 Tare amp Preset lanes ieshotseeutsceidoetore than ine a a E E meen EON 6 STS UME SMET ODEA rinner n aT 6 5 2 Basic Counting 5 2 1 Upper amp Lower Quantity Limit Checking aaooounnnnnnnnnnnnsnrunrrrrrrrrnnnnnrrrrrrrrrnne 7 9 2 2 EMENGO a KNOWMUNICW EION was cnen nat einionsseed ad tint anid E A 7 5 2 3 Sample COUNTING SAGAN cessrissasnner EE teladiaasGienleeeea se 7 5 2 4 Accumulation Accumulation Display and Accumulation Clear cceeeeeeeee 8 6 Calibration 6 lromOle PON Gala Miwssss cores cay tei teasonsestocdsnnisuledavees rans edarwentacal au ydeieee tan debouleoes 9 62 PIMC AIC alll
8. alculated or recalculated 11 M Symbol VY points at M when scale is in accumulation mode 12 UW Under entering a known unit weight mode Symbol VY points at UW when entered unit weight is lower than 4 5 of scale division Unit weight is too small for ensuring accurate quantity calculations 13 SMPL Under the sample counting mode Symbol VY points at SMPL when calculated unit weight is lower than 4 5 of scale division or the quantity of sample is less than 10 pieces 14 UNIT WEIGHT Unit Weight Window Displays the average unit weight value or number of weighmenis 15 TOTAL COUNT Total count window Displays the calculated number of pieces on the weighing pan or accumulated piece count value 16 WEIGHT Weight Window Displays weight of object on weighing pan or accumulated weight value 4 2 2 Keyboard ro JE A EERE OYNORT 1 0 9 numeric keys Enters specific values for tare unit weight and other data entries JCL 4 2 key Decimal point toggles between upper limit and lower limit setting when HI LO OK function is enabled See 7 2 1 1 PRINT key Outputs data when Prt Pr print stably is selected as the print mode 2 ZEROkey Zeros the display within 2 of max capacity or cancels Tare action 3 TARE key Inputs the weight of the object on the weighing pan as a Tare value inputs the indicated value entered via the numeric keys as a pre set Tar
9. all Ol ciust ive a fetus ose su cnuus eeanneem asin oe a A E 9 Te DOUG IN OGG watcher tence E AE ee eons 10 8 Serial Interface SERO LLA GONO OE eeener ene ene sre tt mere en eto ae ee ee ee ner eer ee eer 40 B22 NIE OD NO Minie a tes Gu be wi uesadcnan ever 40 BG 292 OULU ONM Aleera EREKE RE NEKEA 40 9 Troubleshooting and Error Message ccceeceeeeee eee eeee eee 13 JCL 0 1 Introduction Thank you for deciding to purchase a JCL counting scale from Jadever This goods has the excellent performance and splendid properties under severe quality management It is recommended to read this manual in full before using it for good function application 2 Precautions P hce the scak on a fatand stabk surface See 3 3 Leveling the Scale for details Verify thatthe nputvolage and the pug type matches the bcalAC power supply See 4 3 Power Supply W arm up the scale for 15 minutes before using it the first time Keep the scak away from EMI noise stong wind and vbraton whith m ight cause incorrect reading Avoid sudden temperature changes suitable operating temperature is between 5 C 40 C D isconnectthe powersupply when ckanng the scak Do not immerse the scale in water or other liquids Service should be perfom ed by authorzed personnelony 3 Before Using the Product 3 1 Unpacking and Checking Open the package and check the instrument for transport damage Immediately inform your
10. e value cancel tare action 4 CEkey Clears the indicated input values 5 MC CK key Short press deletes accumulation records long press to initial Upper amp Lower Quantity Limit setting 6 MR key Recalls and displays the total Accumulation data weight total count and number of weightments and the first 10 records in details 7 UWS key Inputs the indicated unit weight value entered via numeric keys 8 M key Adds the indicated weight or piece count value into Accumulation memory 9 SMPLkey Short press enters the sampling mode 4 3 Power Supply Power supply Please verify the local AC power source and switch the two stage switch to the proper place before plugging into the power outlet Alternative power supply 1 AC 110V 220V AC 10 2 6V 4A internal rechargeable battery Power Consumption About 300mW without backlight About 380 mW with backlight Low battery warning When 2 appears in the upper left corner of the weight window the battery power requires recharging The charge lamp turns green from red when the recharging is completed which takes about 8 hours Disconnect the scale from power supply when it is fully charged A full charged battery can operate the scale for approximately 65 hrs with backlight 80hrs without backlight Note Battery is to replaced only by an authorized service dealer Risk of explosion can occur if replaced with the wrong type or connected improperly JCL 5 5 Operati
11. ess numeric key 3 to set the period l HE of inactivity before the scale automatically turns off Options are OFF Non power off 5 10 30 and UF 60 minutes 5 Press numeric key 4 to set the range in which the SEEY zero indication turns on Options are dO d1 d2 d3 d4 and d5 d scale division 6 Press numeric key 9 to set serial transmission SEES bAlid rates Options are 9600 4800 and 2400 7 Press numeric key f to set buzz sounds Options are Un In no Lo and nbEEP to y n Lin There will be a warning sound when the quantity of the articles exceeds upper limit t N There will be a warning sound when the quantity of the articles is between the upper and lower limit including the upper and lower limits no There will be a warning sound when the quantity of the material exceeds the upper and lower limits and the weight of the material is more than 20 divisions JCL 10 Se L There will be a warning sound when the quantity of material is less than the preset lower limit and the weight of the material is more than 20 divisions LEC NLET No sound alarm 8 Press numeric key 8 to select whether to save previously quantity checking values mun Previously set quantity checking values are not retained when the unit is turned on A wee oy iy MATI 11 0N Previously set quantity checking values are retained when the unit is turned on 9 Press numeric key 9 to shift print modes
12. f Cae Coe Cog cy 3 Put the second piece of load on then Press key M to add the second accumulation event into memory Repeat step 2 3 till accumulation actions are finished Note Maximum is 99 pieces Accumulation Display Press key MR to displays the total accumulation data weight count and number of weighments and the first 10 accumulation events in detail Accumulation clear To clear the total accumulation data or the first 10 accumulation events Press key MC CK while the data is displayed Symbol V disappears when the total accumulation data is deleted 6 Calibration 1 For best results calibrate the scale at regular intervals Temperature changes geographic gravity variations altitude changes and abuse are few reasons why a scale may need recalibration 2 Here we take JCL 15K as an example JCL 8 6 1 Single Point Calibration 1 Press and hold key SMPL while powering on the scale 2 Input 11 with numeric keys co T 3 Again press key SMPL to enter the zero point calibration modes rey 4 Wait till 2 1 LIIL flashes press numeric key 7 to select calibration weight Options are 1 3 of full load 2 3 of full load and full load E g options for JCL 15K are 5 10 and 15 kg Put the corresponding weights on the weighing pan H IIE E J al a 6 The calibration procedure is completed with a I tI flashing on the weight screen Now remove all the weights 5 Press key
13. on Here we take JCL 15k model as an example 5 1 Basic Weighing 5 1 1 Weighing Place item to be weighed on the scale The weight window shown is 2000g Gross Weight 5 1 2 Tare amp Preset Tare Mo cz co ca I Tare When weighing a sample that must be held in a container taring stores the container weight into memory 1 Under the weighing mode place the container on the scale weight window shown is 500g Press the key TARE to complete tare action The lt gt symbol appears and with Symbol Vv pointing at NET 2 To clear tare with an empty pan Press down the key TARE or key ZERO aI N N C3 cS gt cS c gt e3 O YU Preset Tare 1 Under the unload condition Enter tare value using the numeric keys together with cou key e then press key TARE The weight window displays the tare value 2 Put the load on the container the scale will automatically deduct the value of the container from the total value Note during the process of Tare or Preset Tare if the load and container are not removed press key Zero to check the gross weight 5 1 3 Unit Switch Operation 1 Press key SMPL while powering on the scale 2 Key in 1132 via numeric keys 3 Again press key SMPL to enter unit Selection GEL mi mode Numeric key J is to toggle between g kg and Lb units m mr cof n cof c JCL 4 Press key SMPL to save and then press key ZERO to return to the weighing mode 5 2 1
14. on or the quantity of sample is less than 10 pieces 3 Remove the samples and put the load on the scale begins to count 4 Press key CE to return to the weighing mode JCL 7 ACAI Automatic Counting Accuracy Improvement ACAI results in a more accurate count by increasing the reference weight without the need to count additional parts A higher reference weight is important when there is a risk of inconsistent piece weights or if the reference weight is close to the minimum ACAI uses an initial averaging unit weight to count additional pieces that are placed on the scale after a few seconds the scale gives a beep as the new higher reference weight is used to recalculate the averaging unit weight The process can be repeated as long as the additional weight is less than the previous reference weight Once this limit is exceeded ACAI is turned off 43393 Soe ee 5 2 4 Accumulation Accumulation Display and Accumulation Clear 1 Enter the indicated unit weight press key UWS 7000 AT CJ Co Co Co and put first piece of load on the weighing pan Or into a tared container Refer to 7 2 2 2 Press key M the first accumulation event a C3 cy cy is displayed momentarily before Symbol Vv pointing at M The display reverts to normal weighing mode in a second remove the first piece of load O i rc cc C3 ma J ee My Mo ID C58 nug Cofi nug e Mu Cof Cbf Cof Cof C co C gt Co
Download Pdf Manuals
Related Search
Related Contents
SlimPublisher 4.1 User Manual CMS-50D Fingertip Pulse Oximeter Manual LevelOne FCS-4400 MSI ER710 User Guide Manual - Downloaded from LpManual.com User Manual - Flash Manual de Instalação 1771-6.5.15, Bulletin 1771 Communication Controller Module User Samsung DVD-HD945 Manuel de l'utilisateur 接 の 新 ス テ ー ジ 接 の 新 ス テ ー ジ の 新 ス テ ー ジ の 新 ス テ ー ジ Copyright © All rights reserved.