Home

G50 GSM alarm User Manual - diy

image

Contents

1. Smoke sensor Gas sensor Glass break sensor Remote control Panic button Speaker External high sensitivity MIC Infrared Beam detector Infrared Fence detector etc Optional sirens Wired amp wireless indoor siren amp strobe siren Wired amp wireless outdoor strobe siren G50 GSM alarm user manual 1 4 Main unit layout LED Siren switch GSM antenna socket Siren socket Keypad MIC speaker socket SIM card socket Cover Le G Wy Ay Sa WA Fa Pp Sy 5 hy Si Ta le lon Mo Soy Mag Mg Ory Ory Disarm Year Month Day Hour Minute Main unit back Wired door sensor Reset Tamper switch ON WOO ON i Z i Power switch Relay output Resistor against cut ired sensor socket 2 Installation 2 1 Install main unit a Insert a valid SIM card into main unit Note Make sure the SIM card 1s valid G50 GSM alarm user manual b Install the GSM external antenna Note The main unit with internal antenna itself and external antenna available c Fix and hide main unit 2 2 Install accessories 2 2 1 Install the door window magnetic contact The principle of door window contact sensor The door window magnetic contact includes two parts The sensor will send the wireless signal to main unit immediately when the two parts depart more than 15 30mm The picture of the installation is as follows Double Faced Tape ya Alarm Indicator In some circumstances the wired
2. LCD display input 1 N OK the LCD flashes then trigger the remote controller immediately It means successful learning when the LCD background light stops flashing The learning time is 10s Note N stand for 01 02 03 04 16 total 16 remote controllers you can learn Example learn first remote controller input 101OK on keyboard of main unit b Cancel remote controller After passing the verification of administrator password press SET button when SET COM appears on the LCD display input N OK the LCD will flash three seconds then stop The remote controller is deleted successfully Note N stand for 01 02 03 04 16 3 3 2 Learn cancel wireless sensors a Learn wireless sensors After passing the verification of administrator password press SET button when SET COM appears on the LCD display input 2 N OK the LCD flashes then trigger the wireless sensor immediately It is learnt successfully when the LCD stops flashing The learning time is 10s Note N stand for 01 02 03 04 40 total 40 wireless sensors you can learn Zone 01 to 32 for common wireless sensors such as wireless PIR sensor door window magnetic contact glass break sensors etc Zone 33 to 36 for wireless fire alarm detectors such as wireless smoke gas detectors Zone 37 to 40 for wireless emergency button Example learn first wireless PIR sensors press 201OK on keyboard of main unit Learn first
3. to 28 and 31 32 33 36 24 hours full day arm fire alarm zone specially for wireless gas smoke detectors 37 40 24 hours full day arm emergency zone specially for wireless panic button Example CEO room GM Room Financial dept Personnel dept Marketing Dept Zone 29 Zone32 Zone Ol Zone 02 03 Customer service Dept Shipping dept Purchasing dept zone 04 R amp D dept zone 05 Engineering dept zone 06 zone 07 zone 08 Production dept Ware house 10 09 CEO with 15 remote controller General Manager with 16 remote controller Financial dept zone 01 is programmed as independent partial arm zone Personnel dept with 02 remote controller CEO arm disarm 15 remote controller all the zone is armed disarmed except for zone 32 and zone 01 e e G50 GSM alarm user manual General manager arm disarm 16 remote controller all the zones are arm disarm except for 29 and zone 01 Personal dept arm disarm 2 remote controller all the zones are armed disarmed except for zone29 32 01 Financial dept is independent partial arm zone only SMS can arm disarm it CEO room is triggered only send alert to the forth pre set phone No quietly General manager is triggered only alert to the fifth pre set phone No quietly Zone classification solution can prevent inside thief infectively 5 SMS control command 5 1 Set delete five mobile phone numbers for SMS alarm a Set the mobile phone No SMS format four digi
4. wireless smoke detectors press 2330K Learn the second wireless emergency button press 238OK b Cancel wireless sensors 12 G50 GSM alarm user manual After passing the verification of password press SET button when SET COM appears on the LCD display input N OK the LCD will flash three seconds then stop The wireless sensor is deleted successfully Note N stand for 01 02 03 04 40 3 3 3 Cancel all the wireless sensors amp accessories After passing the verification of password press SET button when SET COM appears on the LCD display input 999 OK on Main unit keyboard the LCD will stop to flash in 4s All of them are deleted 3 4 Connect wired sensors 3 4 Exit setting In the setting mode press ESC to exit The setting mode will exit automatically if no response within 15 seconds 4 Zone classification Total 40 wireless zones each zone can only learn one wireless sensors 01 28 common zones 01 24 can be programmed as independent partial arm zone please see for details 29 30 special zones Only fifteenth remote controller can arm disarm it Only send alert to the preset forth alarm receiving phone number The fifteenth remote controller can control 01 to 28 and 29 30 31 32 special zone only sixteenth remote controller can arm disarm it only send alert to the preset fifth alarm receiving phone number The sixteen remote controller can control 01
5. 0 C Humidity 20 to 95 Accessories 1 Remote controller Power Requirement DC12V Transmitting Freqency 3 15 0 2Mhz 433 0 2Mhz Transmit Distance more than 80m no obstacle Coding type Learning code Lifespan of battery half year trigger 20 times everyday 2 Wireless Door window magnetic contact Power requirement DC 12V 8 4V 23A DC 12V battery inside Wireless Freqency 3 15 0 2Mhz 433 0 2Mhz Transmit Distance more than 80m no obstacle Coding type Learning code Lifespan of battery half year trigger 20 times everyday Low voltage reminder value lt 10 5V 3 Wireless PIR motion sensor Power Requirements DC9V Wireless Freqency 3 15 0 2Mhz 433 0 2Mhz The largest coverage 12 12m Visual Angle 110 Bracket Adjustable Angle 45 to 45 Horizontal line Bracket Adjustable Angle 15 to 45 Vertical line e G50 GSM alarm user manual Coding Type Learning code Lifespan of battery half year trigger 20 times every day Low voltage reminder value lt 2 2V Siren Power Requirements DC12V Volume More than 110db Color black 1 3 Standard packing list Main unit x 1 GSM antenna x Remote control x 2 Wireless door window magnetic contact x Wireless PIR sensor x 1 Wired siren x 1 AC DC adapter x User manual x 1 Optional wired amp wireless accessories Door window magnetic contact Magnetic steel scrolling door sensor PIR motion sensor Curtain PIR sensor Ceiling PIR sensor Vibration sensor
6. 0 GSM alarm user manual the neighbors At the same time the system automatically sends SMS alert and auto dial the preset phone numbers The user can listen to the prerecorded voice warming and what happened in alarm area when any phone is answered and remotely operate as follow Press the Main unit armed Press 2 the Main unit disarmed Press 3 drive siren Press 4 close siren Press two way communication Press Stop to call the next phone numbers The system will auto dial the next phone number if the phone line 1s busy or can t put through It will stop to call the next one when somebody answer the phone and press If nobody answers the phone the system will stop dialing after auto dialing circularly for three times 6 6 Emergency alarm Press on remote control or the emergency button the Main unit auto dial the preset phone numbers and send SMS of Emergency alarm to ask for help 6 7 External power failure alarm When the system checks out that there is something wrong with the external power or the external power is off for more than 2 seconds it makes alarm call immediately and send SMS of External power failed The system stops alarming immediately and send SMS of External power is OK when the power supply is OK 6 8 Delay alarm setting
7. G50 GSM alarm user manual G50 GSM alarm User Manual Ver 1210 2008 12 10 G50 GSM alarm user manual Contents 1 Instruction 1 1 Function amp Feature 1 2 Specification 1 3 Standard packing list 1 4 Main unit layout 2 Installation 2 1 Install main unit 2 2 Install accessories 2 2 1 Install door window magnetic contact 2 2 2 Install PIR motion sensor 2 2 3 Install smoke gas detectors 3 Operation steps 3 1 Turn on 3 2 Keypad setting 3 2 1 Password verification 3 2 2 Set delete check 6 mobile phone numbers for SMS alarm 3 2 3 Set delete check 5 phone numbers for call alarm 3 2 4 Set delete check 1 SMS forwarding phone No 3 2 5 Recording voice 3 2 6 Change passwords 3 2 7 Change ID 3 2 8 Set date amp time of main unit 3 2 9 Set cancel fixed arm disarm partial arm time 3 3 Learning code 3 3 1 Learn cancel remote control 3 3 2 Learn cancel wireless sensors 3 3 3 Cancel all wireless accessories 3 4 Exit setting 4 Zone classfication 5 SMS command 5 1 Set delete 5 mobile phone numbers for SMS alarm 5 2 Set delete 5 phone numbers for call alarm 5 3 Set delete 1 SMS forwarding phone No 5 4 Change password 5 5 Arm disarm 5 6 Change zone name 5 7 Set inquiry delete independent partial arm zone 5 8 Inquire arm disarm status 5 9 Inquire external power status 5 10 Relay output 6 Usage 6 1 Arm disarm 6 2 Handfree mobile phone 6 3 Door window open reminder 6 4 Sensors low voltage remin
8. MS to user automatically e Work with monitoring center such as police station e One relay output control DVR Home appliance remotely e Sensors low voltage reminder e Learning code for wireless accessories e Voice operation reminder e Recording voice e Three level password management e With independent partial arm function e Zone classification prevent inside thieves effectively e Two fixed arm time two fixed disarm time and one fixed partial arm time e 2 wireless address encode reduce the rate of same code greatly e SMS control amp program e SMS modifies wireless zones name e Arm disarm by keypad remote controller phone or SMS e Call the main unit to listen in status whenever e Internal MIC or external high sensitivity MIC optional e Internal GSM antenna or external antenna optional e Main unit with tamper switch e External power failure alarm e Entry delay alarm e Two way communication G50 GSM alarm user manual e Handfree mobile phone 1 2 Specification Main unit 1 GSM freguency 900 1800MHz 850 1900MHz optional 2 External power failure alarm Start time less than 5s 3 Alarm response time Less than 10s GSM in normality 4 Delay arm time 30s 5 Power Power requirement AC110 220V 50Hz or 60Hz DC9V Working power consumption less than 3W Standby battery DC7 4V 7OOMAH Standby battery working hours more than 10 Hours 6 Working conditions Operating temperature 20 C 6
9. The zone and zone 2 have this function So zone sensor and zone 2 sensor can be installed on the way from the door to the GSOE machine With this function the user enter the room can have enough time to disarm the G50E Zone 1 send SMS 12341D00 Zone 2 send SMS 12342D00 1234 is the Administrator Password 00 is the delay alarm time It can be 00 seconds 15 seconds 30 seconds 45 seconds So you can send these messages to set up this function12341D00 12341D15 12341D30 12341D45 If you set up this function you enter the room can hear the sound DI DI DI DI DI DI DI DI DI DI until you disarm the system 7 Events record History record A After passing the verification of password press SET when SET Ea appears on the LCD display Press 00 01 02 03 32 check Then you can the see the message on the display likes this AO 09 02 08 13 20 AO 1s the code for the event 09 is the year 02 is the month 08 is the day 13 is the hour eit G50 GSM alarm user manual 20 is the minute 00 01 02 32 is the order of the event B The code for the events FF invalid event 71 arm by the keypad 12 arm by SMS or TEL 73 disarm by the keypad 74 disarm by SMS or TEL 75 partial arm by keypad 76 power off J7 power on 7F turn on the G50E 80 partial arm by first remote controller 81 partial arm by second remote controller 82 partial arm by third remote controller 83 partial arm by 4th remo
10. amp wireless Infrared Fence detector is more appropriate than magnetic sensors 1 e veranda picture window balcony boundary wall co a ET Wired or wireless glass break detector can also be used for window see below SS l The sensitivity is adjustable G50 GSM alarm user manual Wireless scroll steel door magnetic sensor for scrolling steel door Installation Please see below picture It is triggered when the two parts are separated to 3cm 5cm 2 2 2 Install PIR motion sensor PIR refers to passive Infra red A Passive Infra red Sensor is an electronic device that detects the motion or movement of some person or animal by sensing the heat emitted from the body Installation Wireless PIR motion sensor Horizontal angle 90 110 degree Vertical angle 30 50 degree 1 3m Surveillance Area PIR s diagram AE 3O 16 0 165 50 46 2 2 3 Install smoke gas detectors a Wired or wireless smoke detector This smoke detector detects smoke by a couple of infrared diodes which is suitable for detecting the smoke in house shop hotel restaurant office building school bank library and storehouse etc 8 G50 GSM alarm user manual TEST BUTTON INDICATOR b Wired or wireless gas detector The product is ceiling mounted gas detector with high stability It is used for detecting leaking gas and suitable for the safety of residential house villas
11. der 6 5 Deal with alarm 6 6 Emergency alarm 6 7 External power failure alarm 6 8 Delay alarm setting 7 Events record History record G50 GSM alarm user manual 1 Instruction The alarm system adopts SMS data transmission and voice platform of GSM network to send control command and receive alarm remotely which is designed for house office supermarket etc indoor use It will call amp send alarm SMS to user cellphones immediately when any sensor is triggered The system can also be used as handfree mobile phone for two ways communication The LCD on the alarm Main unit can show the time data operation guide alarm details and status of arm disarm GSM signal power etc With the LCD all the operation and program are visual and intuitive The system with human kind voice guide and can be recorded into all different kinds of languages and work well all over the world The low voltage warning for sensors and door window opened reminder make use more friendly The function in details as follows 1 1 Function amp Feature e Color LCD screen keypad with blue background light e Maximum 4 wireless panic buttons 4 wireless fire detectors 16 remote controllers 32 wireless intruder detectors e Maximum 8 wired zones Zone 1 and zone 2 for wired door window magnetic contact which will remind you if the door window 1s open e Send alarm SMS to 5 preset mobile phone No e Auto dial 5 preset user phone No e Forward mobile company S
12. ecord 3 2 6 Change password After passing the verification of administrator password press SET when SET PAS appears on the LCD display operate as below Factory password Changing command Check new password Administrator Password 1234 1 new password OK 3 Inquiry Password 9012 3 new password OK Example Set 4321 as the new administrator password Input 1 4321 OK then you will hear di di sound for confirmation 3 2 7 Change ID After passing the verification of administrator password press SET when SET ID appears on the LCD display input six new ID numbers OK Note the initial ID is 000000 Example Set 123456 as the new ID Input 123456 OK then two sounds of di di for confirmation Press check to inquiry the new ID 3 2 8 Set data amp time After passing the verification of password press SET when SET Ci appears on the LCD display Input year month day hour minute second each with two numbers OK then you will hear di d sound for confirmation Example Suppose the present time is 12 13 05 and the date is 08 01 2007 input 070108121305 OK 3 2 9 Set cancel fixed arm disarm partial arm time a Timing arm In arming status press SET when SET ey appears on the LCD display then Input N time hour minute OK Two sounds of di di will confirm the operation Note N stands for 1 and 2 total two fixed time you ca
13. ee level password protection G50 GSM alarm user manual Administrator 1934 Authorized to operation all E g set disarm Password inquiry remote control etc Only for check whether the program is correct 3 Inquiry Password 9012 or not 3 2 2 Set delete check five mobile phone numbers for SMS alarm a Set the mobile phone number After passing the verification of administrator password press SET button when SET SMS appears on the LCD display input N mobile phone number OK Note N stands for 1 2 3 4 5 One of them can be for monitoring center Max 18 digits of phone numbers Example Set 1368888888 as the first SMS receiving mobile phone number input 1 1368888888 OK then two sounds of d di for confirmation According to the method you can finish the setting of the other four mobile phone numbers b Delete the mobile phone number Input N OK for cancel c Check the mobile phone number Input N check the programmed phone numbers will appear on the LCD for check 3 2 3 Set delete check five phone numbers for call alarm a After passing the verification of administrator password press SET button when SET TEL appears on the LCD display Input N phone number OK Note N stands for 1 2 3 4 5 The phone number can be mobile phone or telephone Max 18 digits Example Set 1368888888 as the first alarm call receiving phone number input 1 1368888888 OK then
14. enters into disarm status after it makes di di sound and the mk is on Press mal on main uint keypad the Main unit speak please input password administrator password or Disarm password It is disarmed when you hear di The mi is on all the time 6 2 Handfree mobile phone The main unit can be used as mobile phone a Make a phone call Press the main unit LCD shows TEL then input phone number OK to make a call Press ESC to hand up the phone call CLS clear the wrong numbers a Answer the incoming call The main unit voice di di when there is a incoming call Press OK to answer it ESC button hand up the phone call 6 3 Door window open reminder The LCD show Door window is open with voice warming when user arm it if the door window in wired zone and zone 2 is not closed 6 4 Low voltage reminder for sensors The main unit sends SMS of the sensors with no voltage to first SMS receiving mobile phone and the LCD show DAT LO number with voice warming to remind of users change battery And if any sensor is low voltage the G50E will send a message to the host every 24 hours 6 5 Alarm and Handle 4 SMS TEL and zones appear on the LCD display in alarm mode P external power failure E Emergency alarm F fire alarm 01 32 wireless sensors alarm The siren sounds loudly for 90 seconds to inform 16 G5
15. ependent partial arm zone the one without the A just a gap isn t the partial arm zone By the SMS Send the SMS to the mail unit the SMS likes this Password AA Then the main unit will send the SMS back to you about the independent partial arm zone C Delete indepent partial arm zone Send the SMS likes this to the main unit Password AD zone 01 02 24 5 8 Inquire arm disarm status Send SMS 4 digits of password W1 Reply SMS The Main unit s arm disarm status 15 G50 GSM alarm user manual 5 9 Inguire external power status Send SMS 4 digits of password W2 Reply SMS The Main unit s external power status 5 10 Relay output control Send SMS 4 digits of password RI NC Send SMS 4 digits of password R2 NO Reply SMS relay output NC or NO 6 Usage 6 1 Arm disarm a Arm Press m on remote controller or main unit main unit will make di sound the LCD display is on fg is twinkling 30 seconds later the main unit enters into arm mode and the ml is on Please press on remote controller for immediate arm b Partial arm press f on remote controller or main unit the main unit will make di sound the LCD display is on Ll is twinkling 30 seconds later the main unit enters into partial arm mode and f is on Press the 4 on remote controller for immediate partial arm c Disarm Press m on remote controller to close the system the main unit
16. hotels boarding house etc Detecting the gas heavier than air installation height from floor 0 3m 1 0m semi diameter to gas sources lt 1 5m detecting the gas lighter than air installation height from ceiling 0 3m 1 0m semi diameter to gas sources lt 1 5m dm leri Open or close manipulator Test button Power LED green DIAM ETER Working LED 3M 3 Operation steps 3 1 Turn on Make sure that the power supply is connected correctly and turn on the main unit power switch It will search the GSM network automatically within 25 seconds after it 1s started Then the LCD display turns on and shows the model No and the status of arm disarm GSM signal etc GSM network is normal when LED indicators under the disarm button flash regularly When the external power is normal the LCD background light keeps on If there is no external power it is off automatically after operation 3 2 keyboard setting Note When setting by the keyboard every time you press the button you will hear di sound for confirmation Please press it again if there s no voice Press CLS button before inputting OK to cancel the input numbers If the LCD display shows FAIL check and reset it 3 2 1 Password verification Press SET input password OK then you will hear di di sound for confirmation While SET and SMS appear on LCD display it means that the password is correct Total thr
17. m 2E door or window zone 06 alarm 2F door or window zone 07 alarm 30 door or window zone 08 alarm 31 tamper switch alarm Operation Cautions 1 The eguipments are not water proof not suitable for outdoor use 2 Install the system in a hidden place 3 Turn off the power supply before insert take out the SIM card 4 Connect the power supply firmly and provide good heat dissipation 5 Don t install the system close to the objects which generate strong magnetic interference such as TV set and computer 6 Check all the detectors and their battery in time and change them when voltage is low 7 Check the GSM alarm system regularly 20
18. n set Example Set 16 08 and 22 30 as the auto arm time input 1 1608 OK and 2 2230 OK The Main unit will be armed automatically at 16 08 and 22 30 For inquiry press 1 check and 2 check To cancel it press N 9999 OK in arm mode b Timing partial arm 11 G50 GSM alarm user manual In partial arm status press SET when SET appears on the LCD display then input time hour minute OK Note Only one auto partial arm time can be programmed Example Set 16 25 as the auto partial arm time input 1625 OK then two sounds of di di for confirmation The Main unit will be in partial arm automatically at 16 25 For inquiry press check To cancel it press 9999 OK in partial arm mode c Timing disarm In disarming status press SET when SET appears on the LCD display then input N time hour minute OK Two sounds of di di will confirm the operation Note N stands for 3 and 4 total two fixed time you can set Example Set 19 25 and 7 30 as the auto disarm time input 3 1925 OK and 4 0730 OK The Main unit will be disarmed automatically at 19 25 and 7 30 For inquiry press 3 check and 4 check To cancel it press N 9999 OK in disarm mode 3 3 Learning code 3 3 1 learn cancel remote controller a Learn remote control After passing the verification of administrator password press SET button when SET COM appears on the
19. on the message will be forwarded to 1368888888 automatically 14 G50 GSM alarm user manual b delete the phone No SMS format four digits of password DT 6 5 4 Change password SMS format 4 digits of password DP 4 new numbers for password Example The initial password is 1234 if you want to set 5678 as the new password Send SMS 1234DP5678 5 5 Arm disarm Arm by SMS 4 digits of password A1 Disarm by SMS 4 digits of password A2 Example The Main unit s password is 1234 If you want to set the Main unit in arm mode Send SMS 1234A1 5 6 Change zone s name SMS format 4 digits of password DM zone s code 2 digits changed name Reply SMS the new zone s name Example The password is 1234 If you want to change zone 06 s name to be PIR alarm for bedroom Send SMS 1234DM06 PIR alarm for bedroom Note Changed name should be less than 24 characters 5 7 Set inquiry delete independent partial arm zone a Set partial arm zone Send the SMS to the main unit the SMS is like this Password AA Zone 01 02 03 23 24 The zone ol to zone 24 can be set as independent partial arm zone B Inquiry independent partial arm zone By the keypad After passing the verification of password press SET when SET TYPE appears on the LCD display press check Then all the Alarm receiver numbers can receive a SMS likes this Zone type 01 A 02 A 12 24 The zone with the A is ind
20. ote controller AB disarm by 12th remote controller AC disarm by 13th remote controller AD disarm by 14th remote controller AE disarm by 15th remote controller AF disarm by 16th remote controller 01 wireless zone alarm 02 wireless zone 2 alarm 03 wireless zone 3 alarm 04 wireless zone 4 alarm 05 wireless zone 5 alarm 06 wireless zone 6 alarm 07 wireless zone 7 alarm 08 wireless zone 8 alarm 09 wireless zone 9 alarm 0A wireless zone 10 alarm 0B wireless zone lalarm 0C wireless zone 12 alarm 0D wireless zone 13 alarm OE wireless zone 14 alarm OF wireless zone 15 alarm 10 wireless zone 16 alarm 11 wireless zone 17 alarm 12 wireless zone 18 alarm 13 wireless zone 19 alarm 14 wireless zone 20 alarm 15 wireless zone 21 alarm l6 wireless zone 22 alarm 17 wireless zone 23 alarm 18 wireless zone 24 alarm 19 wireless zone 25 alarm 1A wireless zone 26 alarm 1B wireless zone 27 alarm IC wireless zone 28 alarm 19 G50 GSM alarm user manual ID wireless Zone 29 alarm IE wireless zone 30 alarm IF wireless zone 31 alarm 20 wireless zone 32 alarm 21 fire zone Ol alarm 22 fire zone 02 alarm 23 fire zone 03 alarm 24 fire zone 04 alarm 25 emergency zone 01 alarm 26 emergency zone 02 alarm 2 emergency zone 03 alarm 28 emergency zone 04 alarm 29 door or window zone 01 alarm 2A door or window zone 02 alarm 2B door or window zone 03 alarm 20 door or window zone 04 alarm 2D door or window zone 05 alar
21. te controller 84 partial arm by 5th remote controller 85 partial arm by 6th remote controller 86 partial arm by 7th remote controller 87 partial arm by 8th remote controller 88 partial arm by 9th remote controller 89 partial arm by 10th remote controller BA partial arm by 11th remote controller 8B partial arm by 12th remote controller 8C partial arm by 13th remote controller 8D partial arm by 14th remote controller SE partial arm by 15th remote controller SF partial arm by 16th remote controller 90 arm by first remote controller 91 arm by second remote controller 92 arm by third remote controller 93 arm by 4th remote controller 94 arm by 5th remote controller 95 arm by 6th remote controller 96 arm by 7th remote controller 97 arm by 8th remote controller 98 arm by 9th remote controller 99 arm by 10th remote controller 9A arm by 11th remote controller 9B arm by 12th remote controller 9C arm by 13th remote controller 9D arm by 14th remote controller 9E arm by 15th remote controller OF arm by 16th remote controller 18 G50 GSM alarm user manual A0 disarm by first remote controller Al disarm by second remote controller A2 disarm by third remote controller A3 disarm by 4th remote controller A4 disarm by 5th remote controller A5 disarm by 6th remote controller A6 disarm by 7th remote controller A7 disarm by 8th remote controller AS disarm by 9th remote controller A9 disarm by 10th remote controller AA disarm by 11th rem
22. ts of password DS N mobile phone number Note N stands for 1 2 3 4 5 One of them can be for monitoring center Example Set 1388888888 as the first SMS receiving mobile phone number The Main unit s password is 1234 Send SMS 1234DS11388888888 b Delete the mobile phone No SMS format four digits of password DS N 5 2 Set delete five phone numbers for call alarm a Set the phone No SMS format 4 digits of password DT N phone number Note N stands for 1 2 3 4 5 The phone No can be telephone or cellphone Example Set 01088888888 as the first phone number for auto dialing alarm The Main unit s password is 1234 Send SMS 1234DT101088888888 b Delete the phone No SMS format four digits of password DT N 5 3 Set delete one SMS forwarding phone number The messages from the pre set phone number can be forwarded to the first alarm SMS receiving phone number Recommend users to set the mobile company phone number so that users can know the SIM card status of main unit timely to make sure normal communication a Set the phone No SMS format 4 digits of password DS N phone number Note N stands for 6 The phone No can be telephone or cellphone Example The mobile company phone number is 10086 The preset first alarm SMS receiving phone No is 1368888888 The password is 1234 Send SMS 1234DS610086 to main unit When the mobile company sends a SMS of Your mobile no enough money please charge so
23. two sounds of di di for confirmation b Delete the phone number Input N OK for cancel c Check the phone number Input N check the programmed phone numbers will appear on the LCD for check 3 2 4 Set delete check one SMS forwarding phone number The messages from the pre set phone number can be forwarded to the first alarm SMS receiving phone number Recommend users to set the mobile company phone number so that users can know the SIM card status of main unit timely to make sure normal communication a After passing the verification of administrator password press SET button when SET SMS appears on the LCD display Input N phone number OK Note N stands for 6 Example The mobile company phone number is 10086 The preset first alarm SMS receiving phone No is 1368888888 10 G50 GSM alarm user manual input 6 10086 OK then two sounds of di di for confirmation When the mobile company sends a SMS of Your mobile no enough money please charge soon the message will be forwarded to 1368888888 automatically Note The phone No can be deleted and checked as per the point b amp c of 3 2 2 2 2 3 3 2 5 Record voice After passing the verification of administrator password press SET when SET REC appear on the LCD display press OK to begin the 9 seconds record The main unit LCD starts to count down and exits automatically in 9 second Press CHECK to play the r