1. setting Why doesn t the Industrial Fast Ethernet Switch connect to the network Solution Check per the port LED on the Industrial Fast Ethernet Switch Try another port on the Industrial Fast Ethernet Switch Make to sure the cable is installed properly Make sure the cable is the right type Turn off the power After a while turn the power back on MC 4TX Series Industrial Ethernet Switch User Manual 23 Chapter 5 Troubleshooting 24 MC 4TX Series Industrial Ethernet Switch User Manual Appendix A Network Connection Switch s RJ 45 Pin Assignments 10 100Mbps 10 100Base TX RJ 45 Connector pin assignment MDI MDI X Contact Media Dependant Media Dependant Interface Interface Cross 1 Tx transmit Rx receive 2 Tx transmit Rx receive 3 Rx receive TX transmit 4 5 Not used 6 Rx receive Tx transmit 7 8 Not used RJ 45 Connector pin assignment 12345678 Me MC 4TX Series Industrial Ethernet Switch User Manual 25 Appendix A Network Connection The standard RJ 45 receptacle connector There are 8 wires on a standard UTP STP cable and each wire is color coded The following figure shows the pin allocation and color of the straight and crossover cable connection Straight Cable SIDE 1 SIDE 2 12345678 SIDE 1 1 White Orange 1 White Orange 2 Orange 2 Orange 3 White Green 3 White Green 4 Blue 4 Blue 5 White Blue 5 White Blue 12345678 SIDE 2 6 Green 6 G
2. throughput and availability Store and Forward store and Forward is one type of packet forwarding techniques A Store and Forward Industrial Switch stores the incoming frame in an internal buffer do the complete error checking before transmission Therefore no error packets occurrence it is the best choice when a network needs efficiency and stability The Industrial Fast Ethernet Switch scans the destination address from the packet header searches the routing table provided for the incoming port and forwards the packet only if required The fast forwarding makes the switch attractive for connecting servers directly to the network thereby increasing throughput and availability However the switch is most commonly used to segment existing hubs which nearly always improves overall performance An Ethernet Switching can be easily configured in any Ethernet network environment to significantly boost bandwidth using conventional cabling and adapters Due to the learning function of the Industrial Fast Ethernet Switch the source address and corresponding port number of each incoming and outgoing packet are stored in a routing table This information is subsequently used to filter packets whose destination address is on the same segment as the source address This confines network traffic to its respective domain reducing the overall load on the network The Industrial Fast Ethernet Switch performs Store and Forwara therefore no error pa
3. Gbps e Integrated address look up engine supports 2K absolute MAC addresses e Mbit on chip frame buffer on MC 4TX1FXMM 2km MC 4TX2FX Series e Automatic address learning and address aging e CSMA CD Protocol Industrial Case Installation e P 30 Metal case Protection e DIN Rail and Wall Mount Design MC 4TX Series Industrial Ethernet Switch User Manual 3 Chapter 1 Introduction 12 to 48V DC redundant power with polarity reverse protection function and connectivity with a removable terminal block for master and slave power 10 to 60 C operating temperature on the MC 4TX1FXMM 2km MC 4TX1FXSM 15KM MC 4T X2FX MC 4TX Series Industrial Ethernet Switch User Manual Chapter 1 Introduction Product Specifications Hardware Specification 4 x 10 100Base TX Auto negotiation Auto MDI MDI X Copper 10Base T 2 pair UTP Cat 3 4 5 cable 100meters max 100Base TX 2 pair UTP Cat 5 cable 100meters max Fiber Optical Multi mode Single mode 9 31 x 3 42 x 1 26 135 x 87 x 32mm Weight 0 965 lbs 436g 0 965 Ibs 436g 0 977 lbs 442g 12 48 VDC Power Requirement Redundant power with polarity reverse protection function Power Consumption 9 1 Watts 31BTU 11 6 Watts 40BTU 9 1 Watts 31BTU Dissipation Installation DIN rail kit and wall mount ear Switch Specification Switch Processing Store and Forward Scheme Address Table Butter iM Back pressure for half duple
4. Switch User Manual Chapter 1 Introduction MC 4TX1FXMM 2Km MC 4TX1FXSM 15Km MC 4TX2FX The IFS MC 4TX Series of Industrial Ethernet Switches is an industrially hardened Ethernet Switch specifically designed to operate reliably in electrically harsh and climatically demanding environments The IFS MC 4TX Series of Industrial Ethernet Switches has an IP 30 metal case Each of them is equipped with 4 10 100Base TX Auto negotiation ports and one or two 100Base FX optic fiber SC interfaces It provides a multi mode or single mode 100Base FX SC interface and the fiber transmission distance can be 2km or 15km away from the link to remote backbone MC 4TX Series Industrial Ethernet Switch User Manual Chapter 1 Introduction The IFS MC 4TX Series includes the following models MC 4TX1FXMM 2Km 4 1 100FX Port Multi mode Industrial Ethernet Switch SC MM 2km MC 4TX1FXSM 15Km 4 1 100FX Port Single mode Industrial Ethernet Switch SC SM 15km MC 4TX2FX 4 2 100FX Port Multi mode Industrial Ethernet Switch SC MM 2km Package Contents Check the contents of your package for following parts Industrial Fast Ethernet Switch x 1 User s Manual x 1 DIN Rail Kit x 1 Wall Mount Kit x 1 lf any of these are missing or damaged please contact your dealer immediately if possible retain the carton including the original packing material and use them against to repack the product in case there is a need to return it to us How to
5. a DIN Rail on the Industrial Fast Ethernet Switch please refer to following figures to screw the DIN Rail onto the Industrial Fast Ethernet Switch To hang the Industrial Fast Ethernet Switch follow the below steps 1 Screw the DIN Rail on the Industrial Fast Ethernet Switch 12 MC 4TX Series Industrial Ethernet Switch User Manual 2 Lightly press the button of DIN Rail into the track 3 Check the DIN Rail is tightly on the track MC 4TX Series Industrial Ethernet Switch User Manual Chapter 2 Installation Chapter 2 Installation 4 Please refer to following procedures to remove the Industrial Fast Ethernet Switch from the track 5 Lightly press the button of DIN Rail to remove it from the track Wall Plate Mounting To install the Industrial Fast Ethernet Switch on the wall please do the following 1 Remove the DIN Rail from the Industrial Fast Ethernet Switch loosen the screws to remove the DIN Rail 2 Place the wall mount plate on the rear panel of the Industrial Fast Ethernet Switch 14 MC 4TX Series Industrial Ethernet Switch User Manual Chapter 2 Installation 3 Use the screws to secure the wall mount plate on the Industrial Fast Ethernet Switch 4 Use the hook holes at the corners of the wall mount plate to hang the Industrial Fast Ethernet Switch on the wall 5 To remove the wall mount plate reverse the steps above MC 4TX Series Industrial Ethernet Switch User Manual 15 Ch
6. aa interlogix A UTC Fire amp Security Company IFS MC 4TX Series Industrial Ethernet Switch User Manual Copyright Disclaimer Trademarks and patents Intended use Manufacturer Certification FCC compliance ACMA compliance Canada European Union directives z Contact information Contact support 2011 UTC Fire amp Security All rights reserved This document may not be copied in whole or in part or otherwise reproduced without prior written consent from UTC Fire amp Security except where specifically permitted under US and international copyright law The information in this document is subject to change without notice UTC Fire amp Security assumes no responsibility for inaccuracies or omissions and specifically disclaims any liabilities losses or risks personal or otherwise incurred as a consequence directly or indirectly of the use or application of any of the contents of this document For the latest documentation contact your local supplier or visit us online at www interlogix com This publication may contain examples of screen captures and reports used in daily operations Examples may include fictitious names of individuals and companies Any similarity to names and addresses of actual businesses or persons is entirely coincidental The Interlogix name and logo are trademarks of UTC Fire amp Security The IFS name and logo are trademarks of UTC Fire amp Security Other trade names used
7. apter 3 Application In this section we describe how to install the Industrial Fast Ethernet Switch Serial over Ethernet device Industria z Switch I O Device Subway 2 m m e e e e e eeen 100Base TX UTP M 100Base FX Fiber optic EE DIDO Subway 1 MC 4TX Series Industrial Ethernet Switch User Manual Chapter 3 Application Industrial Switch Industrial Switch Warehouse PLC A oaoa i al Robot a A Robot nH E E E EE EE E EE EE EE EE HE EE EE E A 100Base T X UTP ee I I f 100Base FX Fiber optic I DIDO Factory F m m Installation Steps Unpack the Industrial Fast Ethernet Switch Check that the DIN Rail is screwed onto the Industrial Fast Ethernet Switch Please refer to DIN Rail Mounting section for DIN Rail installation If the DIN Rail is not screwed on the Industrial Fast Ethernet Switch If you want to wall mount the Industrial Fast Ethernet Switch then please refer to Wall Mount Plate Mounting section for wall mount plate installation To hang the Industrial Fast Ethernet Switch on the DIN Rail track or wall please refer to the Mounting Installation section Supply power to the Industrial Fast Ethernet Switch Please refer to the Wiring the Power Inputs section for power input The power LED on the Industrial Fast Ethernet Switch will light up Please refer to the LED Indicators s
8. ause radio interference in which case the user may be required to take adequate measures This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme a la norme NMB 003du Canada 2004 108 EC EMC Directive Hereby UTC Fire amp Security declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 2004 108 EC 2002 96 EC WEEE directive Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union For proper recycling return this product to your local supplier upon the purchase of equivalent new equipment or dispose of it at designated collection points For more information see www recyclethis info For contact information see our Web site www interlogix com www interlogix com customer support Content Chapter 1 Introduction 1 Package Contents 2 How to use this Manual 2 Product Features 3 Chapter 2 Installation 7 Product Description 7 Wiring the Fault Alarm Contact 11 Chapter 3 Application 17 Installation Steps 18 Chapter 4 Switch Operation 21 Address Table 21 Learning 21 Forwarding amp Filtering 21 Store and Forward 22 Auto negotiation 22 Chapter 5 Troubleshooting 23 Appendix A Network Connection 25 Switch s RJ 45 Pin Assignments 25 RJ 45 Connector pin assignment 25 MC 4TX Series Industrial Ethernet Switch User Manual MC 4TX Series Industrial Ethernet
9. ce without risk of packet loss The stable throughput of the device makes it ideal for most Ethernet environments All RJ 45 copper interfaces support 10 100Mbps Auto negotiation for optimal speed detection through RJ 45 Category 5 4 or 3 cables Support is standard for Auto MDI MDI X that can detect the type of connection to any Ethernet device without requiring special straight or crossover cables The flow control function allows Industrial Fast Ethernet Switch supported routers and servers to directly connect to this device for fast reliable data transfer MC 4TX Series Industrial Ethernet Switch User Manual 7 Chapter 2 Installation Switch Front Panel Figure 1 shows the front panel of the Industrial Fast Ethernet Switch Figure 1 MC 4TX1FXMM and MC 4TX2FxX front panels eo 8 P1 P2 FAULT P1 P2 FAULT LNK ACT LNK ACT 10 100 MC 4TX1FXM M LNK ACT MC 4TX2FX 8 MC 4TX Series Industrial Ethernet Switch User Manual Chapter 2 Installation LED Indicators Function Lit indicates the power 1 has power C Lit indicates the power 2 has power FAULT Green Lit indicates the either power 1 or power 2 has no power Fiber Lit indicates the Fiber port is successfully connecting to Optical the network at 100Mbps 10 100 Copper Lit indicates the Switch is successfully connecting to the network at 100Mbps Off indicates that the Switch is successfully connecting to the
10. ckets occur More reliably it reduces the re transmission rate No packet loss will occur Auto negotiation The STP ports on the Industrial Fast Ethernet Switch have built in Auto negotiation This technology automatically sets the best possible bandwidth when a connection is established with another network device usually at Power On or Reset This is done by detect the modes and speeds at the second of both device is connected and capable of both 10Base T and 100Base TX devices can connect with the port in either Half or Full Duplex mode 22 MC 4TX Series Industrial Ethernet Switch User Manual Chapter 5 Troubleshooting This chapter contains information to help you solve issues If the Industrial Fast Ethernet Switch is not functioning properly make sure the Industrial Fast Ethernet Switch was set up according to instructions in this manual The per port LED is not lit solution Check the cable connection of the Industrial Fast Ethernet Switch Performance is poor solution Check the speed duplex mode of the partner device The Industrial Fast Ethernet Switch is run at Auto negotiation mode and if the partner is set to half duplex then the performance will be poor Per port LED is lit but the traffic is irregular solution Check that the attached device is not set to dedicate full duplex Some devices use a physical or software switch to change duplex modes Auto negotiation may not recognize this type of full duplex
11. ection for meaning of LED lights MC 4TX Series Industrial Ethernet Switch User Manual 5 Chapter 3 Application Prepare the twisted pair straight through Category 5 cable for Ethernet connection Insert one side of Category 5 cables into the Industrial Fast Ethernet Switch Ethernet port RJ 45 port and another side of category 5 cables to the network devices Ethernet port RJ 45 port ex Switch PC or Server The UTP port RJ 45 LED on the Industrial Fast Ethernet Switch will light up when the cable is connected to the network device Please refer to the LED Indicators section for LED light meaning NOTE Be sure the connected network devices support MDI MDI X If it does not support it then use a crossover category 5 Cable rg MC 4TX Series Industrial Ethernet Switch User Manual Insert the fiber cable from the MC 4TX1FXMM 2km MC 4TX2FX series to the fiber network TX RX must be paired at both ends The optical port LED on the Industrial Fast Ethernet Switch will light up when the cable is connected to the network device Please refer to the LED Indicators section for LED light meaning When all connections are finished and the LED lights all show a normal condition the installation is complete Chapter 3 Application 20 MC 4TX Series Industrial Ethernet Switch User Manual Chapter 4 switch Operation Address Table The Industrial Fast Ethernet Switch is implemented with an address table This address table is c
12. for the terminal block should be in the range between 12 24 AWG Wiring the Fault Alarm Contact The fault alarm contacts are in the middle of the terminal block connector as the picture shows below After inserting the wires the Industrial Fast Ethernet Switch will detect the fault status of a power failure or port link failure available for managed model and then forms an open circuit The following illustration shows an application example for wiring the fault alarm contacts Figure 5 Fault Alarm contacts 1 2 3 4 5 6 Note The wire gauge for the terminal block should be in the range between 12 24 AWG Alarm relay circuit accepts up to 30V max 3A currents Figure 6 Alarm schematic MC 4TX Series Industrial Ethernet Switch User Manual 11 Chapter 2 Installation Industrial Switch The cloesd circuit will poen when the failure occurs Mounting Installation This section describes how to install the Industrial Fast Ethernet Switch and make connections to it Please read the following topics and perform the procedures in the order being presented NOTE In the installation steps below this Manual uses the GE DSGH 8 IFS 8 Port Industrial Gigabit Switch as an example The steps for the IFS Industrial Switch amp Industrial Media Converter are the same Industrial DIN Rail Mounting The DIN Rail is screwed on to the Industrial Fast Ethernet Switch when shipped from the factory To replace the wall mount with
13. in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products Use this product only for the purpose it was designed for refer to the data sheet and user documentation for details For the latest product information contact your local supplier or visit us online at www interlogix com This product is intended to be supplied by a UL Listed Direct Plug In Power Unit marked Class 2 or LPS and output rated 48 VDC 380 mA minimum UTC Fire amp Security Americas Corporation Inc 2955 Red Hill Avenue Costa Mesa CA 92626 5923 USA EU authorized manufacturing representative UTC Fire amp Security B V Kelvinstraat 7 6003 DH Weert The Netherlands C Oi This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications You are cautioned that any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Notice This is a Class A product In a domestic environment this product may c
14. network at 10Mbps LNK ACT Fiber Lit indicates the link through that port is successfully Optical established Blink indicates that the Switch is actively sending or receiving data over that port Switch Upper Panel The upper panel of the Industrial Fast Ethernet Switch consists of one terminal block connector within two DC power inputs Figure 2 shows the upper panel of the Industrial Fast Ethernet Switch Figure 2 Industrial Fast Ethernet Switch Upper Panel O O V2 V2 Input L DC12 48V Fault PWR2 MC 4TX Series Industrial Ethernet Switch User Manual 9 Chapter 2 Installation Wiring the Power Inputs The 6 contact terminal block connector on the top panel of Industrial Fast Ethernet Switch is used for two DC redundant power inputs Please follow the steps below to insert the power wires 1 Insert the positive and negative DC power wires into the contacts 1 and 2 for POWER 1 or 5 and 6 for POWER 2 NOTE This product is intended to be supplied by a UL Listed Direct Plug In Power Unit marked Class 2 or LPS and output rated 48 VDC 380 mA minimum Figure 3 Power Inputs V2 V2 Input L DC12 48V Fault PWR2 V1 V1 V2 V2 2 Tighten the wire clamp screws securely to prevent the wires from loosing Figure 4 Terminal Block 1 2 3 4 5 6 Power 1 Fault Power 2 10 MC 4TX Series Industrial Ethernet Switch User Manual Chapter 2 Installation NOTE The wire gauge
15. omposed of many entries Each entry is used to store the address information of some node in the network including MAC address port number etc This information comes from the learning process of Industrial Fast Ethernet Switch Learning When one packet comes in from any port the Industrial Fast Ethernet Switch will record the source address port number and the other related information in the address table This information will be used to decide either forwarding or filtering for future packets Forwarding amp Filtering When one packet comes from some port of the Industrial Fast Ethernet Switch it will also check the destination address besides the source address learning The Industrial Fast Ethernet Switch will lookup the address table for the destination address If not found this packet will be forwarded to all the other ports except the port which this packet comes in And these ports will transmit this packet to the network it connected If found and the destination address is located at different port from this packet comes in the Industrial Fast Ethernet Switch will MC 4TX Series Industrial Ethernet Switch User Manual 21 Chapter 4 Switch Operation forward this packet to the port where this destination address is located according to the information from address table But if the destination address is located at the same port with this packet comes in then this packet will be filtered Thereby increasing the network
16. reen 7 White Brown 7 White Brown 8 Brown 8 Brown Cross Over Cable Sued SDE2 1234567 8 SIDE 1 1 White Orange 1 White Orange 2 Orange 2 Orange 3 White Green 3 White Green 4 Blue 4 Blue 5 White Blue 5 White Blue 12345678 SIDE 2 6 Green 6 Green 7 White Brown 7 White Brown 8 Brown 8 Brown Make sure that the cables you are using have the same pin assignments and color as the above picture before deploying the cables into your network 26 MC 4TX Series Industrial Ethernet Switch User Manual
17. use this Manual This User Manual is structured as follows Section Section Content INTRODUCTION Product description with features and specifications Explains the features and functions of the Industrial Fast Ethernet INSTALLATION Switch and how to physically install the Industrial Fast Ethernet Switch APPLICATION Explains the Industrial Fast Ethernet Switch application SWITCH OPERATION Explains the Industrial Fast Ethernet Switch transmit operation TROUBLESHOOTING Describes how to troubleshoot the Industrial Fast Ethernet Switch APPENDIX A Contains cable information for the Industrial Fast Ethernet Switch MC 4TX Series Industrial Ethernet Switch User Manual Chapter 1 Introduction Product Features Physical Port IFS Model Name Pots Fiber Optical Interface copper optica MC 4TX1FXMM Mutil mode 2km 2Km 1 x 100Base FX D LITEM 4 x 10 100Base TX Single mode 15km 15KM MC 4TX2FX Multi mode Layer 2 Features e Complies with IEEE 802 3 IEEE 802 3u 10 100Base TX 100Base FX e Supports Auto negotiation and 10 100Mbps half full duplex mode for each copper port e High performance store and forward architecture broadcast storm control runt CRC filtering eliminates erroneous packets to optimize the network bandwidth e Prevents packet loss with back pressure Half Duplex and IEEE 802 3x PAUSE frame flow control Full Duplex e Backplane Switching Fabric MC 4TX1FXMM 2km Series 1Gbps MC 4TX2FX Series 1 2
18. x IEEE 802 3x Pause Frame for full duplex Switch Fabric ts Throughput Packet Per Second Flow Control 0 74Mpps 64Bytes 0 89Mpps 64Bytes 0 74Mpps 64Bytes Standards Conformance IEEE 802 3 Ethernet 10Base T Standards Compliance IEEE 802 3u Fast Ethernet 100Base TX 100Base FX IEEE 802 3x Full duplex flow control Operating 10 60 Degree C Temperature Storage 40 85 Degree C Operating 5 to 90 Storage 5 to 90 Non condensing Regulation Compliance FCC Part 15 Class A CE Humidity Operating MC 4TX Series Industrial Ethernet Switch User Manual 5 Chapter 2 Installation This section describes the functions of the Industrial Fast Ethernet Switch s components and guides you how to install it on the desktop Basic knowledge of networking is assumed Please read this chapter completely before continuing Product Description The IFS MC 4TX1FXMM 2km MC 4TX2FX series are 4 Port 10 100Mbps 1 2 100FX Fiber Port Industrial Fast Ethernet Switches with non blocking wire speed performance and a new slim type chassis with an IP 30 metal shape for easy deployment in Heavy Industrial demanding environments With a 1 1 2Gbps internal switching fabric the Industrial Fast Ethernet Switch can handle extremely large amounts of data in a secure topology linking to a backbone or high capacity servers The Industrial Fast Ethernet Switch has 2K MAC address table and offers wire speed packet transfer performan
Download Pdf Manuals
Related Search
Related Contents
Samsung RF268ABBP User Manual HQ W9-OHW-10N Cooper Lighting QCT2075 User's Manual Istruzioni per l`uso 200514 7085682 - 01 F-T. E.P. Floor B-C dreamGEAR 9 in 1 Starter Kit for the PSPgo Prepac GRGW-0709-6M Installation Guide 受信アプリケーション取扱説明書 KDS EZFlow 2020/2021 Syringe Driver Pump User`s Manual Copyright © All rights reserved.