Home

PS Power Supply User Manual

image

Contents

1. connectors on each end The wiring pin out is specified by the USITT DMX512 1990 standard XLR Pin Function Common Data Data Talkback Talkback 01 P LON Power Supply User Manual Updated March 2009 Page 14 Specifications Connectors DMX in Male 5 pin XLR DMX out Female 5 pin XLR Output Female 4 pin XLR DMX512 termination None DMX signal pass thru Fuse PS 600 model 20600 Input voltage 100 240V 50 60 Hz 10 5A 250V 7A Slo Blo for 100 120V 250V 4A Slo Blo for 220 240V PS 300 model 20300 Input voltage 100 240V 50 60 Hz 5 3A 250V 4A Slo Blo for 100 120V 250V 2A Slo Blo for 220 240V PS 150 model 20150 Input voltage 100 240V 50 60 Hz 3 1 5A 250V 2A Slo Blo for 100 120V 250V 1A Slo Blo for 220 240V Input Power Automatically accepts 100 240V 50 60 Hz Input Signal 1990 USITT standard DMX512 Red LED Indicates power Green LED Indicates DMX signal Size PS 600 14 356mm L x 7 8 198mm W x 4 1 104mm H Weight 7 9 Ibs 3 6 kg PS 300 14 356mm L x 7 8 198mm W x 3 76mm H Weight 5 4 Ibs 2 4 kg PS 150 12 7 323mm L x 7 6 193mm W x 2 9 74mm H Weight 3 9 lbs 1 8 kg Power Supply User Manual Updated March 2009 Page 15 Parts List Callout Quantity Part Number Description 4 SCRFH632150 Flat head screw 8 Z 2287 Grommet 1 F0825 Fan 600W 1 F6025S Fan 300W 150W 4 1 2060 01 02 Board bracket 600W only 5 4 SCHRFHM4X8 Flat screw head 4mmX8mm 6 4 SCRPH440025P Pan head bla
2. travel along a single cable eliminating the need for a separate power cable for each device Each unit provides power for Wybron s feedback compatible IT products which send feedback to their operators using Remote Device Management an ESTA standard two way communication protocol Power Supply User Manual Updated March 2009 Page 6 System Components Power Supply The power supply accepts DMX512 from a lighting console and passes it along with 24VDC power to each device This eliminates the need for separate control and power cables to each device The DMX512 control signal can also be daisy chained to other PS power supplies or other DMX controlled devices Caution The PS Power Supply is compatible with Forerunner devices but AN NOT the RAM Coloram Il family of devices i e Coloram II CXI Goboram II etc DO NOT connect PS compatible devices to RAM Coloram II Power Supplies or RAM Coloram II compatible devices to PS Power Supplies Damage from such action will not be covered by the equipment warranties PS Compatible Devices Nexera LX Coloram IT CXI IT Forerunner Eclipse IT Iris Eclipse IT Shutter Refer to the user manuals for detailed operating information on these products Power Data Cable The Power Data Cable connects the Power Supply outputs to the connected devices and provides them with power and control signal The cable uses 4 pin XLR connectors on either end and consists of two 14 AWG conductors and a 22
3. AWG twisted shielded pair See the Cable section of this manual for the pin out Power Supply User Manual Updated March 2009 Page 7 PS Power Supply System Connection Diagram Ethernet Infotrace Router Infogate 5 pin gre Figure 2 Coloram IT Power Supply User Manual Updated March 2009 Page 8 Equipment Compatibility The following is a chart of compatibility and capacity of the various models of PS Power Supplies and their companion devices This is current as of the print date of this manual As more products are added to the compatible line an updated list will be available on the Wybron Web site at www wybron com Power Supply PS 150 PS 300 PS 600 Model Number 20150 20300 20600 Output Power 150 watts 300 watts 600 watts Number of Units per Power Supply Description Model Maximum PS 150 PS 300 PS 600 Head Feet Nexera LX Tungsten 82560 1500 8 16 32 82570 82640 Nexera LX CDM 2580 1500 6 12 24 2600 Forerunner 4 7 4540 1500 16 32 64 7140 Coloram IT 4 7 5 84520 1500 6 12 24 87110 Coloram IT 10 810100 1000 4 8 16 Coloram IT Lg Fmt 816090 1000 6 12 24 Coloram IT 15 815010 1000 6 12 24 Coloram IT 8 Light 816080 1000 6 12 24 Aquaram IT 7 5 87080 1000 5 10 20 Aquaram IT 6 Light 816120 1000 6 12 24 Aquaram IT 8 Light 816080 1000 6 12 24 Aquaram IT Lg Fmt 85000 1000 6 12 24 Eclip
4. WYBRON AdvancinglheArtOfLlighting PS 600 PS 300 PS 150 Power Supplies User Manual PS 600 Model 20600 600 watts PS 300 Model 20300 300 watts PS 150 Model 20150 150 watts CONTENTS Declaration of Conformity ccccceeeeeeeeee ee ee ere ere ee ee ee ee aaa Ree 3 Safety INfOTMATOM es sage Lente cena 4 MtOdU UON ei ee ra ke EDIE dns sata en es 6 System Components ere e aaa aaa ee ee aaa ee ee 7 PS Power SUD isine sie eann SE ERe ge Ba aaa menait 7 System Layout Diagram cc eeeeeeeeeeeeeeeeeeeeeeeeeeeeteeeeeee 8 Equipment Compatibility ee ere ee aaa ee ee ee 9 Installing the Power Supply 10 Head Feet Restrictions isa 11 Mounting and Installation Accessories 12 INTOA CE ES anne a RM nids 13 Cables A ra ERE DE EI ET on senha eae Gudea Menten O RO JE a 14 SpecificatlOn S fk Ke eg GT ERE ON ime den 15 PARS LI SU ann en Tente 16 Exploded Parts Diagram ccccccccceeeeeeeeeeeeeeeeeeeeeeeeeeneeneaaees 17 Warranty Information 20 Power Supply User Manual Updated March 2009 Page 2 CE DECLARATION OF CONFORMITY Manufacturers Name Wybron Inc Manufacturers Address 4830 List Dr Colorado Springs Colorado 80919 USA Eguipment Name LX Power Supply Eguipment Model Numbers 20600 20300 and 20150 This product is in conformity with the following standards Referenced Safety Stand
5. ant to modify explain or vary this warranty Acceptance of or acquiescing in a course of performance under this warranty shall not modify the meaning of this agreement even though either party has knowledge of the performance and a chance to object Software version 1 0 Manual revision March 19 2009 Power Supply User Manual Updated March 2009 Page 20
6. ard s Referenced EMC Standard s EN60598 1 EN55022 EN60598 2 17 EN61000 following the provisions of the EU LV Directive 73 23 EEC and the EU EMC Directive 89 336 EEC declare that the equipment specified above conforms to the above Directive s and Standard s Signature ae ae ee Printed Name EN SEN Title VP of L n Date Van S 2e0g _ Power Supply User Manual Updated March 2009 Page 3 Safety Information SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS This manual gives step by step instructions for the preparation setup and operation of the PS Power Supply There is a potential risk of fire electric shock or injury to persons if the product is not used as instructed WARNING When using electrical appliances use basic precautions including e Read this manual before connecting power e Use supervision around children e Use in a dry location only The PS Power Supply is to be used in an indoor environment only and is not intended for residential use For continued protection against risk of fire replace only with same type and rating of fuse Protection against electric shock is assured only if the mains connected power supply cord set is connected to a properly earthed grounding type receptacle An all pole disconnect device must be located adjacent to the unit or if the AC cord is used as the main disconnect device ensure that the socket outlet is located installed near the e
7. ate software Infostore An Internet based application that aggregates data captured by Infogate and allows for the accumulation of historical information related to the equipment performance in the installation IT Products Coloram IT CXI IT Eclipse IT Iris and Eclipse IT Shutter all have updated electronics to support RDM communication plus additional product improvements including sensors to detect a variety of conditions The heart of the Infotrace system is Infogate specialized software that uses RDM to facilitate remote addressing and diagnostics for potentially every piece of equipment mounted on a rig Infogate works with all Wybron manufactured IT products as well as RDM compatible equipment from any other manufacturer Power Supply User Manual Updated March 2009 Page 13 Cables Power Data Cable The power data cable uses 4 pin XLR connectors on either end and consists of two 14 AWG conductors and a 22 AWG twisted shielded pair The shells of the two XLR connectors are not electrically connected together preventing large power currents from flowing from chassis to chassis of the equipment The twisted pair shield is connected at the male XLR connector end only XLR Pin Wire Color Function Size 1 White Ground 14 AWG 2 Green Data 22 AWG 3 Red Data 22 AWG 4 Black 24VDC 14 AWG DMX512 Control Cable The DMX control cable from the lighting console to the power supply is a five conductor cable with 5 pin XLR
8. ck with patch 7 4 SCRFHM4X8 Flat screw head 4mmX8mm 8 2 SCRFH832037 3 8 Flat head black stainless 9 1 2024 01 06 24 way power supply fan plate 10 2 67 1160 ND 5mm green LED 11 2 2060 01 03 LED bracket 12 2 67 1162 ND 5mm red LED 13 1 2060 02 0011 Circuit card 14 1 NCSMP 5 pin chasis MT male 15 8 NC4FD L1 4 pin chasis MT female 600W 16 20 SCRFH440037 Flat head screw 17 1 NC5FP 5 pin chasis MT female 18 1 031 1666 Fuse cap round 19 1 313 007 Fuse 7 amp 20 1 031 1693 Fuse holder body 21 2 SCRFH632037 3 8 Flat head 22 1 10EEA1 Power connector filter 23 4 SCRPH440037 Pan head screw 24 1 2060 01 04 Top Chassis 600W 25 8 SCSRFH632025 Flat head screw 26 4 704 08 03 Rubber feet 27 4 SCRPH832037P Pan head machine black Power Supply User Manual Updated March 2009 Page 16 Exploded View of a PS 600 Power Supply Part Numbers 2X 67 1162 ND Corne AX 67 1162 N CD G 8x 7 2287 fs ff 2X 2060 01 03 gt el jako 2X 67 1180 ND io X E 20240104 o G aoma ED AX SCRFHMAX8 b eh 4X SCRPH440025P _s VE AIT aX D 2X SCREHES203 23 gt 9 8X NC4FD L NCSFP I 20 SCRFH440037 031 1493 2X SCRFH632037 031 1664 813 007 o Power Supply User Manual Updated March 2009 Page 17 2060 01 04 8X SCRFH632025 Gs D bi We Za fa 82 2 CANN sa A u mt 4 4X 704 08 03 AX SCRPH832037P G7 gt Power Supply U
9. e shipped with hanger brackets to allow pipe or truss mounting Follow these steps to install the hanger bracket 1 Disconnect AC power from the power supply 2 Place the power supply on its side on a flat surface 3 Position the brackets as shown on the next page 4 Attach the bracket using a 3 16 Allen wrench and the supplied screws Note Use the supplied thumb screws to clamp the hanger brackets to the desired pipe or truss Power Supply Hanger Brackets Power Supply Rack Mounting The rack mount accessory can be used with up to two Power Supplies and allows them to be mounted into a 19 inch rack Ti Power Supply User Manual RF Updated March 2009 Page 12 Infotrace Imagine checking your lighting equipment and diagnosing any problems without grabbing a ladder or strapping on a harness It s possible with Wybron s award winning Infotrace Control and Management System which gives you the tools to manage your rig without leaving your computer Using the feedback protocol Remote Device Management or RDM Infotrace enables you to inspect and address everything in your lighting system managing it and knowing that it works The diagram above outlines Infotrace s key components which include Infogate The software and hardware required to facilitate the transfer and display of information Infochip A conversion chip that can be used with non RDM equipment to allow communication with the Infog
10. eight allowances will not be accepted WYBRON INC s sole responsibility under this warranty shall be to repair or replace at WYBRON INC s option such parts as shall be determined to be defected on WYBRON INC s inspection WYBRON INC will not assume any responsibility for any labor expended or materials used to repair any equipment without WYBRON INC s prior written authorization WYBRON INC shall not be responsible for any incidental general or consequential damages to property damages for loss of use time profits or income or any other charges The owner s obligations during the warranty period under this warranty are to notify WYBRON INC at WYBRON INC s address within one week of any suspected defect and return the goods prepaid to WYBRON INC at their factory or authorized service center This warranty is contingent on the customer s full and timely compliance with the terms of payment set forth in said purchase order This warranty is expressly in lieu of any and all other warranties expressed or implied including the warranties of merchantability and fitness for a particular purpose and of other obligations and liabilities on our part The owner acknowledges that no other representations were made to him or relied upon him with respect to the quality and function of the goods sold This written warranty is intended as a complete and exclusive statement of the terms thereof Prior dealings or trade usage shall not be relev
11. ible La Protection contre la d charge lectrique est seulement assur e si la s rie de corde connect e principale est connect e un convenablement terre de type Un appareil d branchant doit tre localis c t de l unit ou si la corde de courant alternatif est utilis e comme le principal d branche l appareil S assurer que la douille sortie localise install pr s de l quipement et est facilement accessible LES AVANCES PRINCIPAUX SONT CONFORMEMENT COLORES AU CODE SUIVANT ET DOIVENT ETRE CONNECTES DANS L ARRANGEMENT SUIVANT gt vert et jaune terre gt bleu neutre gt marron ligne L AVERTISSEMENT CET EQUIPEMENT DOIT ETRE FONDE Pour les questions Wybron de contact 1 800 624 0146 ou visite www wybron com L Avertissement de Modification de Produit Les produits de Wybron Inc sont con us et a fabriqu pour rencontrer les conditions d Etats Unis et de norms de s ret internationals Les modifications aux produits pourraient affecter la s ret et rendent le produit non conciliant aux normes de s ret pertinentes Power Supply User Manual Updated March 2009 Page 5 Introduction Wybron s 150 300 and 600 watt PS Power Supply units attach easily to a truss or can be mounted into a 19 inch rack Power Supply unit can be controlled by one or several DMX512 channels that send DMX signals from the lighting console to each device along with 24 volts DC Both the signal and the power
12. quipment and is easily accessible THE MAINS LEADS ARE COLORED IN ACCORDANCE WITH THE FOLLOWING CODE AND MUST BE CONNECTED IN THE FOLLOWING SCHEME GREEN AND YELLOW EARTH BLUE NEUTRAL BROWN LINE WARNING THIS EQUIPMENT MUST BE EARTHED For questions contact Wybron at 1 800 624 0146 or visit www wybron com Product Modification Warning Wybron Inc products are designed and manufactured to meet the requirements of United States and International safety standards Modifications to the products could affect safety and render the product non compliant to relevant safety standards Power Supply User Manual Updated March 2009 Page 4 Notes de S curit EPARGNER CES INSTRUCTIONS LIRE ET SUIVRE TOUTES INSTRUCTIONS Ce manuel donne des instructions pour la preparation l organisation et l op ration du le PS provision d lectricit II y a un risqu de feu d charge lectrique ou la blessure aux gens si le produit n est pas utilize comme instruit AVERTISSEMENT En utilisant des appareils lectriques utilise la prudence fondamentale inclut e Lire ce manuel avant d alimenter ou l installation de l accessoire e Utiliser la prudence pr s des enfants S cher l emplacement seulement Le PS provision d lectricit va tre utilize la maison seulement et pas pour l usage residential Pour la protection continu e contre le risque de feu remplacer seulement avec le m me type et le m me classement de fus
13. se IT Iris 1K 87250 1500 6 12 24 Eclipse IT Iris 2K 812020 1500 6 12 24 Eclipse IT Shutter 89020 1500 8 16 32 1K 2K 811020 Eclipse IT Shutter 817010 1500 6 12 24 Lg Fmt 5K 16 Eclipse IT Shutter 24 82401 1500 6 12 24 Eclipse IT Iris 24 823020 750 3 6 12 CXI IT 4 7 5 87200 1500 6 12 24 816120 CXI IT Lg Format 81605 750 2 5 9 CXI 12 812210 500 4 18 CXI Mariner 87220 1500 6 12 24 CXI MultiPar 87240 1000 4 18 Power Supply User Manual Updated March 2009 Page 9 Installing the Power Supply Mount the Power Supply The Power Supply is designed to be freestanding truss mounted or rack mounted The Power Supply comes with a mounting bracket that hooks over the pipe or truss of your lighting rig and is locked into place with a thumb screw If you use this mounting method connect the Power Supply s safety cable by clipping it around the pipe or truss The Power Supply can also be mounted into a 19 rack using the optional rack mount kit The rack mount kit will accommodate two units side by side Connect the Device to the Power Supply Connect the device to the Power Supply using Wybron s 4 pin power data cable Refer to the HEAD FEET RESTRICTION section of the manual for details of the length of cable runs Note The Wybron Power Data Cable has been specially designed to minimize voltage drop Use only Wybron supplied cable Connect the Power Supply to AC Power Plug the AC cord in
14. ser Manual Updated March 2009 Page 18 Power Supply Units Mounting Accessories 115 01 03P ecco dus SCRWC252075 SCRSC2520037 a ee Power Data Cable Model Numbers mt a PS 600 PS 300 and PS 150 hanger bracket ac Denis Wing screw for power supply hanger bracket to pipe fem Socket cap screw for hanger bracket to power supply Monde 3 power signal cable SRS PEN 5 power signal cable ee 10 power signal cable nono 15 power signal cable ee eer 25 power signal cable AR I LAN 50 power signal cable A ra aunts 75 power signal cable nee 100 power signal cable Power Supply User Manual Updated March 2009 Page 19 Warranty Information WYBRON INC warrants to the original owner or retail customer that for a period of one year from date of delivery of a portable system or energization of a permanently installed system up to a maximum of 18 months from delivery its products will be free from defects in materials and workmanship under normal use and service Warranty does not cover any product or part of a product subject to accident negligence alteration abuse misuse or any accessories or parts not supplied by WYBRON INC Warranty does not cover consumable parts such as fuses lamps or color media WYBRON INC s warranty does not extend to items not manufactured by us Freight terms on warranty repairs are FOB WYBRON INC factory or designated repair facility Collect shipments or fr
15. to a non dimmed power circuit The power supply automatically accommodates 100 240V 50 60 Hz Caution Do not power the Power Supply from a dimmed circuit Severe damage will result and is not covered by product warranty A red LED viewable from the stage indicates power Connect and Set the DMX512 Source Connect the DMX512 signal source to the DMX input connector on the front of the power supply using standard DMX cable The presence of a valid DMX signal will be indicated by a flashing green LED Power Supply User Manual Updated March 2009 Page 10 Head Feet Restrictions The HEAD FEET parameter is a method of accounting for the voltage drop in the power signal cable caused by the current drawn by each device To help understand this issue think of it as water pressure voltage in a hose cable where there are multiple water sprinkler heads color changers If the hose cable is too long or there are too many sprinkler heads color changers the water pressure voltage will be too low HEAD FEET is defined as the sum of cable lengths from each device to a single power supply output For Head Feet information on a specific Wybron product please refer to that product s user manual Power Supply User Manual Updated March 2009 Page 11 Mounting and Installation Accessories The following sections describe how to install and replace mounting accessories Power Supply Hanger Brackets The Power Supply units ar