1. 3 2 1 2 The first three knobs located in the right back are for handpieces water supply adjustment The first two Knobs count from the left are for high speed handpieces and the third knobs for low speed handpieces 3 2 1 3 The fourth knob is for scaler our Lools mil mdk their smiles fj L vour satisfaction 3 2 1 4 The three knobs after the fourth located are for handpieces air supply adjustment The first two knobs count from the left are for high speed handpieces and the third knobs for low speed handpieces 3 2 1 5 Turn the knob clockwise to supply less air pressure or water and counterclockwise to supply more air pressure or water Do not adjust the air and water supply by yourself contact with your local representative for the adjustments 3 2 2 Infrared cup filler 3 2 2 1 Cup detection resetting Cup filler detection default setting is for transparent cup and must be resetting for opaque cup Turn OFF main power press cup filler stand and at the same time turn ON main power let water flow for 1 2 seconds and leave your hand from the cup filler last put the opaque cup to finish setting 3 2 2 2 Amount of water adjustment 3 2 2 1 Remove the rear side cover carefully 3 2 2 2 Use a screwdriver to adjust the knob as shown on the picture 3 2 2 3 Cover the cover by pushing it carefully 3 2 3 Backrest and seat movement speed adjustment Contact with your local representative for the speed adjustment of ba
2. Air Water our tools smil p their smiles g vour satisfaction 3 1 General Operation 3 1 1 Main power switch Before switch ON the dental unit be sure that it is completely installed and in the right position Before leaving the practice be sure that the power is turned OFF 3 1 2 Program setting Press S1 or S2 button till the LED indicator flash red light adjust the chair to a desired position and press again S1 or S2 the LED indicator turned yellow light RE T non aa ROR J E 26 _ LED light indicator eee S1 and S2 program the operating light will turned ON once the chair is positioned into programmed position 3 1 3 Cup filler and spittoon bowl flushing Press spittoon bowl flushing button to activate water supply rinsing the bowl Upon the cup is positioned the infrared cup filler fills water automatically However to supply more water press cup filler button even the patient can do it itself by pressing manual cup filler button Note The spittoon flush is starting to feed the water when the chair seat from rinse position button has been pressed This is preset program as default function our tools smile py their smiles 9 var satisfaction 3 1 4 Instruments Refer to theirs respective user manual which is included in the package 3 1 5 Armrest Swiveled armrest outwards to enable the patient to climb onto or leave the seat more easily 3 1 6 Headrest
3. Pull the headrest out to suit the patient s height Press locking knob on the middle part and swivel head support to desired position Press up to swivel head support and down to swivel headrest 3 1 7 Headrest position for wheelchairs 1 Pull completely the headrest out 2 Rotate it 180 and slide it back into the slot pushing it completely down our tools 5 mil their smiles i L your satisfaction 3 1 8 Foot control Push hard the pedal to provide high speed rotation for handpiece and vice versa for slow down rotation speed While the chair is moving you can push any pedal to stop it 3 1 9 Panoramic X Ray film viewer It can be rotate to a desired position to view the X Ray film comfortably 3 1 10 Standard operating light Standard operating light YS model has two light intensities high and low by switching the switch which is located at the handle 3 1 11 Emergency button In case of emergency push emergency button or any foot control pedal to stop unit operation Lift the assistant unit for stopping chair movement 3 2 General adjustments 3 2 1 Instrument s air and water supply adjustment It s no need to adjust instrument s air and water supply only if the air or water Supply is not enough for the instrument operation They are located under the table gt W Water 3 2 1 1 Ensure that the indicator of pressure gauge indicates at level 3 as standard pressure
4. Grace Chair Mounted Dental Unit QL X5 Hanging Over the patient ti aan lt a mf User s Manual Table of Contents Section 1 1 1 General Information 1 2 Safety Information 1 3 Demolition and Dismantling Section 2 2 1 Product Description Section 3 3 1 General Operation 3 2 General Adjustments Section 4 4 1 Hygiene and Maintenance our Lools smil their smiles vor satisfaction Q WO WwW OE iN 11 13 1 1 General Information Thank you for purchasing QL X5 Dental Unit System Prior using the product please read this USER MANUAL carefully and thoroughly as it provides details of proper implementation of the operations maintenances and troubleshooting instructions QL X5 is designed for use in dentistry sector according to ISO 7494 and ISO 6875 Please keep this manual well preserved for future references 1 2 Safety Information 1 2 1 Precautions and Warnings QL X5 is not approved to be operated in areas where there is a risk of explosion The user must be sure of the operational safety and proper condition of the unit before using the unit Stop working with damaged functional parts Instrument tubing or any tubing may not be treated with adhesive Instrument tubing must be regularly inspected and must be replaced immediately if found damaged After the end of the treatment remove rotating instruments from turbines straight and contra angle han
5. ckrest and seat movement 3 2 4 Delivery unit arm adjustment Contact with your local representative for the loading capacity adjustment of delivery unit arm our tools mil their smiles 12 vour satisfaction 4 1 Hygiene and maintenance 4 1 1 After every patient Remove used aspiration tips canulas Empty one glass of water 100 200 ml with each suction hose by aspirating water and air through the suction handpiece Clean the suction handpieces with Grace Disinfectant or autoclave them Using soft and clean cloth wipe with Grace Disinfectant the suction holders Disinfect with Grace Disinfectant Headrest Armrests Backrest Patient seat Operating light except the plastic part of the cover Instrument hoses Delivery pad Console table Autoclave curing light fiber optic light guide or remove the disposable cover Remove used disposable cover from the intraoral camera Autoclave turbines Autoclave 3 way syringe tip Remove suction handpiece filter 4 1 2 Weekly Clean the entire dental unit with Grace Disinfectant Clean plastic parts of the operating light with soft and clean cloth rinsed with water Clean the turbines hoses by pressing Ozone disinfection button Autoclave delivery and console silicone pad Press Mist Steam drainage button 2 to 3 times Clean water bottle 4 1 3 Monthly Empty the oil collector cup and clean it Clean oil collector Grace Disinfectant our Lools mil their s
6. dpieces and treatments heads Never change the scaler tip without tool to prevent injury and infection Before leaving the room switch off the main switch QL X5 conforms to applicable European Directives Electromagnetic fields may interfere with the functions of implanted systems such as pacemakers Consult the patient before any treatment The maximum load of 150 kg for the lifting movement and 100 kg for the upholstery movement must not be exceeded The maximum loading of the treatment tray is dependent on the instruments used Dentist s treatment tray basically supports 2 kg and Assistant s treatment tray 1 kg 1 3 Demolition and Dismantling Pursuant to Directive 2002 96 EC this symbol shows that the product must not be disposed of as urban waste at the end of its operating life our Lools mile their smiles vor satisfaction 2 1 Product description 2 1 1 Dental Chair A Chair base Utility Center C Headrest E Armrest G Massage button optional I Floor junction box optional K Chair base M Mist Steam drainage button our tools SSMilE pp their smiles vour satisfaction B Backrest D Seat F Multifunction foot control H Backrest air bag button optional J Umbilical L Emergency stop button 2 1 2 Water Unit A Water unit C Infrared automatic cup filler E Manual cup filler button G Electric plug our Lools mil their smiles vour satisfaction B Glass spitt
7. miles var satisfaction
8. oon D Assistant delivery unit F Water bottle air switch optional H Distilled water bottle optional 2 1 3 Assistant Delivery Unit A QL 7 LED curing light B HVE suction C 3 way syringe D Saliva ejector suction E Keypad F Tray amp autoclavable pad 2 1 4 Operating Light A YS halogen operating light B YF halogen operating light C FARO EDI operating light D G com Polaris operating light 2 1 5 Dentist Delivery Unit our tools mile 4 their smiles H vour satisfaction A Hanging delivery unit B Panoramic X ray film viewer C Large tray amp autoclavable pad D Keypad E 3 way syringe F Turbine G Scaler H Low speed or micromotor I Intraoral camera J Oil cup K Over the patient console L Peri apical X ray film viewer M QL 7 LED curing light N Table amp autoclavable pad O Cart unit P Table our tool mMilE a their Ws smile your satisfaction 2 1 6 Keypad a A Ca GE B Assistant Dentist Seat ascending Cup filler Seat descending Spittoon bowl flushing Backrest descending Assistance calling bell Backrest ascending 0 Operating light Chair seat from rinse position Program 1 Return default position Program 2 2 1 7 Multifunction foot control Seat ascending Program 1 Seat descending Program 2 Backrest descending Chair seat from rinse position Backrest ascending Return default position gt DA OG