Home

FIOD 0808 Manual

image

Contents

1. 2729 2840 Fax 91 20 2729 2839 E mail Support renuelectronics com Website WwW renuelectronics com 10 FIOD 0808 Manual FP A Notes MANUAL REVISION If you contact us in reference to this manual please include the following document number Name User Manual For FIOD0808 Part Number URML403 Document UMAN FIOD 0808 10WAY 1106 Revision 3 UMAN FIOD 0808 10WAY 1106 22 11 2006 Panel dimensions and port details are added UMAN FIOD 0808 10WAY 1106 29 11 2006 Power supply multidropping wiring added UMAN FIOD 0808 10WAY 1106 04 01 2007 Communication timeout register is added rea Renu Electronics Private Limited E Survey No 2 6 Baner Road Pune 411 045 Maharashtra INDIA Tel 91 20 2729 2840 Fax 91 20 2729 2839 E mail support renuelectronics com Website Www renuelectronics com 11
2. used for tracking inputs and outputs Unit scans all the inputs continuously and stores this information into Input register Also the data is received from the output register and accordingly the digital outputs are set reset The communication parametes and unit address are set by DIP switch Specifications 1 Power Supply 24VDC 10 2 Digital Inputs OQto5 VDC Low 12 to 28 V DC High 3 Digital Outputs For Relay output 230V AC 2 Amp 30V DC 2 Amp Coil Voltage 24VDC For Transistor output PNP NPN 500 mA Supply Voltage 24VDC 4 Communication Port 2 Wire RS 485 5 I O Terminals Pluggable terminals 6 Operating Temperature 090C to 60 C 7 Storage Temperature 20 C to 80 C 8 Humidity 10 to 90 Non condensing 9 Mounting DIN rail mounting 10 Dimensions DIN rail gt 70 X 100 X 35 mm Communication Parameters And Modbus Tag Definition Unit supports MODBUS driver for communication with Master device COM Port Setting COMM PORT SETTING ADDR5 ADDR6 ADDR3 BAUD2 PARITY 1 PARITY2 cca Renu Electronics Private Limited E Survey No 2 6 Baner Road Pune 411 045 Maharashtra INDIA Tel 91 20 2729 2840 Fax 91 20 2729 2839 E mail Ssupport renuelectronics com Website WWW renuelectronics com 3 FIOD 0808 Manual BAUD RATE BAUD2 BAUD1 9600 poo o 115200 PARITY PARITY2 PARITY1 NONE ee ee The following dedicated modbus registers are assigned to digital in
3. 40072 bit0 Selection bit Retentive If 1 timeout value from 40070 is OR selected Coil 01137 lf O timeout value from 40071 is selected Note The default timeout is 10sec In case of communication break with the host all the outputs are switched OFF after the timeout period is over cca Renu Electronics Private Limited Survey No 2 6 Baner Road Pune 411 045 Maharashtra INDIA Tel 91 20 2729 2840 Fax 91 20 2729 2839 E mail Ssupport renuelectronics com Website WWW renuelectronics com 5 FIOD 0808 Manual Port Details 2 Wire RS485 Port 14 rE FEEFEE F z F F m F F P 5 For using internal termination resistor 120 Ohm short B and TERM REST M GND A S 7 T E j R rrPRrPFrERrE EF E Renu Electronics Private Limited Ay Survey No 2 6 Baner Road Pune 411 045 Maharashtra INDIA Tel 91 20 2729 2840 Fax 91 20 2729 2839 E mail Ssupport renuelectronics com Website WWW renuelectronics com 6 FIOD 0808 Manual Multidropping connection FIOD Unit 1 Jm FIOD Unit 2 FIOD Unit n Note Where n is up to 32 Connecting repeater can increase it to 64 Renu Electronics Private Limited Survey No 2 6 Baner Road Pune 411 045 Maharashtra INDIA Tel 91 20 2729 2840 Fax 91 20 2729 2839 E mail Ssupport renuelectronics com Website WWW renuelectronics com 7 FIO
4. D 0808 Manual PO eCC C SCSCSCSCSsC NSNSNYNYNWSCNSCN N WUC S Power Supply Connection r 24VDC T 10 EARTH Wiring Diagram Digital Inputs should be wired as given below Wiring Diagram for testing Digital Inputs Swi ne SW2_ n SW8 p IP COM Closing SWx will turn on respective inputs cca Renu Electronics Private Limited _ Survey No 2 6 Baner Road Pune 411 045 Maharashtra INDIA Tel 91 20 2729 2840 Fax 91 20 2729 2839 E mail Ssupport renuelectronics com Website WWW renuelectronics com 8 FIOD 0808 Manual Wiring Diagram Relay type Digital outputs should be wired as shown below For FIOD 0808 R B Coil supply Coil supply RLY POLE 1 Y0 NO Y1 NO Y2 NO Y3 NO RLY POLE 2 L1 to L8 are A C Load Renu Electronics Private Limited Survey No 2 6 Baner Road Pune 411 045 Maharashtra INDIA Tel 91 20 2729 2840 Fax 91 20 2729 2839 E mail Ssupport renuelectronics com Website WWW renuelectronics com 9 FIOD 0808 Manual Wiring Diagram Transistor type Digital outputs should be wired as shown below For FIOD 0808 C B FIOD 0808 C B 24 VDC Max 500mA OP COM INTERNAL CIRCUIT For FIOD 0808 P B FIOD 0808 P B 24 VDC 24 VDC INTERNAL CIRCUIT LOAD reaa Renu Electronics Private Limited ee E Survey No 2 6 Baner Road Pune 411 045 Maharashtra INDIA Tel 91 20
5. FIOD 0808 Manual The FIOD series products add digital capability to your PLC SCADA FIOD 0808 model has 8 digital inputs and 8 relay transistor PNP NPN outputs The digital inputs and outputs are isolated from the host device It has one 2 Wire RS485 communication port The COM port is used to connect any modbus master device PLC SCADA Operator Interface device This module supports Modbus RTU Slave protocol Bigg peg aaa a cca Renu Electronics Private Limited 4 _ Survey No 2 6 Baner Road Pune 411 045 Maharashtra INDIA Tel 91 20 2729 2840 Fax 91 20 2729 2839 E mail Ssupport renuelectronics com Website WwWw renuelectronics com 1 FIOD 0808 Manual PA Dimensional Details FIOD units are shipped with a separate DIN rail plate which can be attached to the unit if desired User can use the unit with or without the DIN rail plate Following sketch shows dimensional details of FIOD with the DIN rail plate 0 00 100 00 OO0OO0O0O000 00 0000 00000 0 OO0O0O0O0COOO OOOO 0O 0000 O i Renu Electronics Private Limited Survey No 2 6 Baner Road Pune 411 045 Maharashtra INDIA Tel 91 20 2729 2840 Fax 91 20 2729 2839 E mail Ssupport renuelectronics com Website WWW renuelectronics com 2 FIOD 0808 Manual PLC Communication The unit supports Modbus RTU Slave protocol Dedicated modbus registers are
6. puts and digital outputs Digital I P MODBUS Tag Input Register Input Coil I P1 X0 40001_0 Bito 00001 I P2 X1 40001 1 Bit1 00002 I P3 X2 40001 2 Bit2 00003 00004 I P5 X4 40001 4 Bit4 00005 400015 Bit5 00006 40001_6 Bit6 00007 40001 7 Bit7 00008 X2 SZ Nr N Nr N cca Renu Electronics Private Limited _ Survey No 2 6 Baner Road Pune 411 045 Maharashtra INDIA Tel 91 20 2729 2840 Fax 91 20 2729 2839 E mail Ssupport renuelectronics com Website WWW renuelectronics com 4 FIOD 0808 Manual Digital O P MODBUS Tag Output Register Output Coil 40065 0 Bito 1025 40065_1 Bit 1 1026 40065 2 Bit2 1027 40065_3 it 3 1028 40065 4 Bit4 1029 40065 5 Bit5 1030 40065 6 Bit6 1031 mem m mm a ee xr xer x Sr Nr Nr Nr ee O P8 Y7 40065_7 Bit7 1032 Modbus Tag Name of the tag Default Valid Range 40070 Communication Retentive 1 to 65535 Holds the communication timeout Timeout for own times multiple value If unit doesn t reveive it s own frame of 100msec frame within this timeout period it declares communication break 40071 Communication Retentive 1 to 65535 Holds the communication timeout timeout for ideal times multiple value If communication line is communication of 100msec completely ideal No frame from line master for other slaves also within this timeout period unit declares communication break