1. exceed the defined quantity the number will flicker in the Number display LAU Ut 5 6 7 8 9 CAS 2 314 16 J amp Set the LOW limit of sample quantity 200 51817181591 Eee 2 416 amp Set the HIGH limit of sample quantity m Quantity of sample lt LOW limit set Number blinks on the display m Quantity of sample gt HIGH limit set 5 Number blinks on the display with beep m To get out of this mode press the key three times and press the C key and the TARE key 4 How to Use Tare Function m Tare is the weight of a container from real weight on the platter The TARE key subtracts the weight of the container A Unknown Tare m If you do not know the weight of the container you may use this method m Make sure that ZERO lamp is on ri c b Place the container on the platter 4 Ett Lt b 3 Place the sample in the container Display will show only weight of the sample 4 4 5 6 7 8 9 CAS 0 11 2 31 41 Press the TARE key lt ri ri Li Li Li 5 6 7 8 9 CAS 9111 2 amp Remove the container and press the TARE key Known m If you know the weight of the container you may use this method m Make sure that ZERO lamp is on 5 6 7 8 9 CAS 5 6 7 8 9
2. CAS Eod 1 amp Enter the weight of the container Press the TARE key gt NOTE In case of 2 5CS if the weight of the container is 10g you have to type 100 Because the weight of the container is displayed 10 0g in the weight display If the weight of the container is 20 5g you have to type 205 then the weight display shows the 20 5g na ri ri 704 Li gt 4 b 4 b Place the sample with container amp Remove the sample with container from the platter the platter 5 6 7 81 9 CAS 011 2 31 41 Press the TARE key to remove tare function TABLE 1 Range of the Tare Weight MODEL MAX WEIGHT MAX TARE WEIGHT MIN WEIGHT 2508 25kg 999 50 5 Computing Error Alarm This scale has an alarm function for too light sample unit This function shows the possibility of calculating errors Sample Weight Lack Alarm If sample weight is within the range of sample weight lack Refer to TABLE 2 Lack of Sample lamp will blink with beep in CS model an 200 l 999960 S TS T7T8T3T CAS b amp Enter the number of the samples amp Place the samples on the platter Zu STST7T8T3T CAS 12134 67 For example this scale is 10CS so 30g is within the r
3. Counting Scale CS So ri S OWNER S MANUAL C51 0033 1 2008 11 PRECAUTIONS mmn A PREFACE enne 6 NAMES AND FUNCTIONS 6 OPERATIONS mmn 8 1 When You Know the Nunber of the Sanples 8 2 When You Know the Unitof the Sanples 9 Checking the Defined Quantity 9 4 How to Use Tare Function 5 Computing Eror Alarm B Make sure that you plug your scale into the proper power outlet Plug into a power outlet minutes before operations Do not disassemble the scale When any damage or defect occurs contact your CAS p authorized dealer immediately for proper repair te SS gt 2 Do not overload beyond the maximum weight limit Scale must be grounded to minimize electricity static This will minimize defect or electric shock Do not pull the plug by its cord when unplugging Damaged cord could cause electric shock or fire To prevent from fire occurring Do not place or use the scale near flammable or corrosive gas To reduce electric shock or incorrect reading Do not spill water on the scale or place it in humid condition v Avoid placing the scale near heater or in direct sunlight Insert plug firmly to wall outlet to prevent electric shock For consistent and accurate reading maintain periodical check by your CAS authorized dealer Attention Place the scale on firm and temperature
4. S Loi 2 314 T8 amp Remove the samples and press the C key 3 Checking the Defined Quantity If the number of samples exceed the defined quantity the display will blink with an alarm This function helps unit packaging of quantity checking A CS Type D LL 5 6 7 8 91 1 f CAS 91112 3 i Press key 3 times ri 5 617 819 f CAS Lo 1 2 83 4 c 8 Press the TARE key Then the defined quantity is entered LULA 5161718191 CAS 2 3 Te amp Enter the defined quantity If you want to change the defined quantity press the C key and enter the defined quantity again 000000 t b amp Place the samples on the platter r cas 2 3 befe Enter the unit weight STST7T8 3T Cas 1 2 3 eee amp Remove the samples from the platter and press the C key B CSH Type 8 Te 7 813 men CAS 01112131414 Press 3 times Lt mu 5161718191 Cas 2 3 4 gi Press TARE key to go to HIGH limit of sample quantity mode ri s e 7 8 9 kefe Cas 12 3 Press TARE key to input HIGH limit of sample quantity and then automatically go to normal mode 5 6 7 8 9 CAS i Press the WGT key If these samples
5. When you know the number of the samples you can use this method m Make sure that ZERO lamp is on LL ULL Lt 51171 8 CAS 4 Place the samples on the platter amp Enter the number of the samples with the numeric keys 4 ri ri ri LLL fn foal nl FS TST7T8T3T CAS 5 TST7T8T3T espe CAS 91112131415 1314162 E Press the NUM key then Unit Weight display Remove the samples and press the C key will show the unit weight sample 5 Type If the number of sample exceeds 100 000 units the unit weight display shows with beeps Please remove the sample from the platter and press C key to clear previous transaction CS Type If the number of sample exceeds 100 000 units maximum displaying limit nothing shows up on the display 2 When You Know the Unit Weight of the Sanpies m When you know the unit weight of the samples you can use this method m Make sure that ZERO lamp is on ri Ll OOOOOO0 4 YN Place the samples on the platter 5 6 7 8 9 CAS 12 8 Press the WGT key then the Number display will show the number of the samples cas 791116131416 amp Enter the unit weight 4 FS TS T7T8T3T espe CA
6. ange of sample lacking Refer to TABLE 2 In this case Lack of Sample lamp will be flickered Until the flickering disappears increase the sample weight Unit weight can be changed and the number of samples will be calculated automatically 8 To know the unit weight press the NUM key Lack of sample lamp blinks Unit Weight Lack Alarm m If unit weight is within the range of unit weight lack Lack of unit weight lamp will be flickered Refer to TABLE 2 TABLE 2 Range of the sample amp unit weight lack RANGE OF SAMPLE RANGE OF UNIT MODEL WEIGHT LACK WEIGHT LACK 2 5CS 2 5kg 0 12 50 0 0 25g 0 259 0 054 1005 10kg 0 509 5kg 25CS 25kg 0 1259 0 2 59 055 00255 CS 10H 10kg 0 50g 0 050 05 20 20kg 0 1009 SPECIHCATIONS MODEL CS Type 2 5CS 5CS 106 256 LACKINGRANGEOFSAMPLE 0 12 55 0 259 0 509 90 1259 0 0459 0 059 0 19 UN FUNCTION Unit Weight Weight Quantity DIGITS on DISPLAY 5 515 OPERATING TEMPERATURE 10 C 40 C MODEL CSH Type CS 05H CS 10H CS 20H smxeso Tio 2x20 0 255 0 809 um ummemmeeouw vane 0059 ots Notice Specifications are subject to change for improvement without notice
7. consistent environment Avoid sudden shock to the scale Internal mechanism could be damaged Grab on the bottom of the scale when moving Do not hold by the platter Keep the scale away from other electromagnetic generating devices This may interfere with accurate reading By adjusting 4 corners of the scale set the scale even using the built in scale leveling indicator Qo c 22 PREFACE Thank you for the purchasing of our CAS CS Series These series has been designed with CAS reliability under rigid quality control and with outstanding performances Your departments can enjoy with this high quality reliable CAS product This electronic load cell scale eliminates all the moving parts and furnish an accurate digital display of all the information We believe that your needs will be satisfied and you will have reliability with in variable weight This manual will help you with proper operations and care of the CS series Please keep it handy for the future references PLATTER DISPLAY KEYBOARD LEVELING GAUGE ADJUSTING BOLT DISPLAY amp KEYBOARD WEIGHT UNIT WEIGHT NUMBER LACK OF ZERO SAMPLE TARE LACK OF uw 5 6 7 8 9 CAS 0 1 2 3 4 WEIGHT DISPLAY m This display shows the weight of the sample on the platter m When the tare removed from the platter display shows the tare weight with m If the weight exceeds the max
8. imum capacity of the scale display will show O L and you will hear a beep sound m The 4 symbol represents the lamps on the displays ZERO Lamp If the ZERO lamp is on it means that weight is zero TARE Lamp If the TARE lamp is on it means that tare is entered UNIT WEIGHT DISPLAY m This display shows the unit weight of the sample or recorded sampling quantities m Lack of Sample This lamp blink when the sample is lacked m Lack of U W This lamp blink when unit weight is smaller then set value NUMBER DISPLAY m This display shows the number of the sample m FUNCTION KEYS FUNCTIONS 10 9 Numeric keys used to enter numerical data Used to enter the unit weight with decimal point cl Clear key used to clear recorded unit weight or recorded quantity When you know the number of the samples you can know the unit weight by pressing this key When you know the unit weight you can know the number of WGT the samples by pressing this key NUM zero Used to set the ZERO point ne Used to clear TARE entries and to enter TARE weight Turns the display on or off Set all displays to ZERO Plug the scale into an AC socket and make sure that the socket s power is within the scale s operating range The scale count up to 9 s and you will hear a beep Check the power voltage p NOTE Plug into a power outlet 10 minutes before operations 1 When You Know the Number of the Samples m