tempmate.®-M User Manual
Contents
1. Viewing operation During logger recording or stopping status insert the logger to computer then the data could be viewed by software or PDF report generated in the U disk PDF reports are different if there is alarm setting gt If no alarm setting there is no alarm information column and in data table no alarm color marking and at the left upper corner it displays PDF in the black rectangle gt If the alarm is set as upper lower alarm it has alarm information column and it has three lines information upper alarm information standard zone information lower alarm information In data table for upper alarm recording data it displays in red and for lower alarm data displays in blue And in the left upper corner if alarm occurs the background of rectangle is in red and display ALARM inside If no alarm occurs the background of rectangle is in green and display OK inside gt If the alarm is set as multiple zone alarm in PDF alarm information column it could have max Six lines upper 3 upper 2 upper 1 standard zone lower 1 lower 2 In data table for upper alarm recording data it displays in red and for lower alarm data displays in blue And in the left upper corner if alarm occurs the background of rectangle is in red and display ALARM inside If no alarm occurs the background of rectangle is in green and display OK inside Note 1 Under all alarm modes if data table zone for Marking data it displays in green
2. if the Vr record points are invalid data USB connection USB pause data PAUSE sensor failure or sensor is not connected NC then the recording marking is in gray And in PDF curve zone for the case of USB data connection USB data pause PAUSE sensor failure NC all of their lines will be drawn as bold gray dotted lines 2 if connect logger to computer during recording there is no recording data during connection period 3 During the period of logger connection with computer whether there is PDF report generated in U disk depends on initial parameter configuration 7 Multple start The logger supports the function of continuous starting after last logger stopping without the need to reconfigure the parameters Key function description Left key Start restart logger menu switch pause Right key MARK manual stop TEE ae Battery management 1 Battery level indication Battery level indication Battery capacity 40 100 20 40 Note When the battery capacity is lower or equal to 10 please replace the battery at the soonest If the battery capacity is lower than 5 the device will stop recording 2 Battery replacement 1 Replace steps 2 NOTE It is suggested to check battery before restart the logger to ensure that for battery remaining could finish the recording task The battery could be replaced before you configure the parameter After replacement of battery use
3. 1 30 15 13 22 23 26 30 Apr 15 13 26 33 305 51 30 Apr 15 13 30 43 28 6 76 30 Apr 15 13 34 53 2 30 Apr 15 13 22 33 27 30 Apr 15 13 26 43 30 3 52 30 Apr 15 13 30 53 286 77 30 Apr 15 13 35 03 28 1 B 30 Apr 15 13 22 43 28 30 Apr 15 13 26 53 302 53 30 Apr 15 13 31 03 285 78 30 Apr 15 13 35 13 28 3 4 30 Apr 15 13 22 53 29 30 Apr 15 13 27 03 30 11 54 30 Apr 15 13 31 13 285 79 30 Apr 15 13 35 23 28 5 E 30 Apr 15 13 23 03 30 30 Apr 15 13 27 13 30 55 30 Apr 15 13 31 23 284 80 30 Apr 15 13 35 33 28 6 6 30 Apr 15 13 23 13 31 30 Apr 15 13 27 23 299 56 30 Apr 15 13 31 33 284 81 30 Apr 15 13 35 43 28 7 7 30 Apr 15 13 23 23 32 30 Apr 15 13 27 33 298 57 30 Apr 15 13 31 43 284 82 30 Apr 15 13 35 53 28 8 8 30 Apr 15 13 23 33 33 30 Apr 15 13 27 43 297 58 30 Apr 15 13 31 53 28 3 83 30 Apr 15 13 36 03 28 9 9 30 Apr 15 13 23 43 34 30 Apr 15 13 27 53 297 59 30 Apr 15 13 3203 283 84 30 Apr 15 13 36 13 29 1 30 Apr 15 13 23 53 35 30 Apr 15 13 28 03 295 60 30 Apr 15 13 32 13 28 3 85 30 Apr 15 13 36 23 29 3 11 30 Apr 15 13 24 03 36 30 Apr 15 13 28 13 295 61 30 15 13 32 23 282 86 30 Apr 15 13 36 33 29 4 30 Apr 15 13 24 13 37 30 Apr 15 13 28 23 294 62 30 15 13 32 33 282 87 30 Apr 15 13 36 43 29 6 30 Apr 15 13 24 23 38 30 Apr 15 13 28 33 293 63 30 Apr 15 13 32 43 28 1 88 30 Apr 15 13 36 53 29 8 14 30 Apr 15 13 24 33 39 30 Apr 15 13 28 43 292 64 30 Apr 15 13 32 53 28 1 89 30 Apr 15 13 37 03 30 30 Apr 15 13 24 43 40 30 Apr 15 1
4. 3 28 53 29 1 65 30 Apr 15 13 33 03 28 1 90 30 Apr 15 13 37 13 30 1 30 Apr 15 13 24 53 41 30 Apr 15 13 29 03 29 1 66 30 Apr 15 13 33 13 28 91 30 15 13 37 23 30 2 30 15 13 25 03 42 30 15 13 29 13 29 67 30 15 13 33 23 28 92 30 15 13 37 33 30 4 30 Apr 15 13 25 13 43 30 Apr 15 13 29 23 28 9 68 30 Apr 15 13 33 33 28 93 30 Apr 15 13 37 43 30 5 19 30 Apr 15 13 25 23 44 30 Apr 15 13 29 33 289 69 30 Apr 15 13 33 43 28 94 30 Apr 15 13 37 53 30 5 30 Apr 15 13 25 33 45 30 Apr 15 13 29 43 289 70 30 Apr 15 13 33 53 279 95 30 Apr 15 13 38 03 30 5 30 Apr 15 13 25 43 46 30 Apr 15 13 29 53 288 71 30 15 13 34 03 27 9 96 30 15 13 38 13 30 4 30 Apr 15 13 25 53 47 30 Apr 15 13 30 03 288 72 30 Apr 15 13 34 13 27 9 97 30 Apr 15 13 38 23 30 4 30 Apr 15 13 26 03 48 30 Apr 15 13 30 13 287 73 30 Apr 15 13 34 23 27 9 98 30 15 13 38 33 30 3 24 30 Apr 15 13 26 13 49 30 Apr 15 13 30 23 287 74 30 Apr 15 13 34 33 27 9 99 30 Apr 15 13 38 43 30 3 25 30 Apr 15 13 26 23 50 30 Apr 15 13 30 33 286 75 30 Apr 15 13 34 43 28 100 30 Apr 15 13 38 53 30 3 About Help 44 First ENSE pispiay first page data pispiay previous page data EEAS Display next page data BALLA Display last page data co skip to the specific page 2 Data query page 4 Back Next 2 End GO TMM150400001 a E TMM150400001 0000000000001 144 31 1 C 27 9 C 15 13 22 23 30 Apr 15 13 46 13 E
5. TMM150100003 0000000000001 20 23 4 22 4 C 22 Apr 15 16 45 14 22 15 16 48 24 E TMM150400042 0000000000001 70 18 1 C 18 C 22 Apr 15 08 36 45 22 15 08 48 15 First Back Next 2 End 2 k elect A Select all loggers View the detailed information of the selected logger Delete 4 T Display all loggers which have exceeded upper lower limit Delete the data of selected logger OK OK OK TN all recording include the normal temperature data and over temperature data Data management function Back to home page ENSE pus first page data REES pisplay previous page data 242 b wen EEAS Display next page data last page data BON skip to the specific page 3 Data management page Backup or Restore Database Data backup save data in the format of ELT Restore data Data restore Restore ELT file and read it by software Back Back to home page 4 Parameter setting page SerialNumber 150412541 Description Temperature recording Internal ID 0000000000001 13 characters max Log Interval H is M S Log Cycle 333D 8H OM 0S Multiple Start Stop Enable DisplayTime 15 Probe Mode Pause Enable Disable Stop Mode Password Temporary PDF Temp unit Set password Six digits or characters Time Zone uw Str tot Siar ei Tur Y StartTime 2015 5 25 D 1 H 46 1 No A
6. l automatically save the data and display the prompt of auto data saving If new data are recorded and insert the logger to computer once more user needs to save the data manually by clicking the button and it will display a dialog box to save the data Data base query interface it displays all saved data information pal Export data in the format of PDEEXCEL or ELT Logger Setup Logger parameter setting om Parameter information Device ID Data logger ID Log Interval Record interval Time Zone Time Zone Probe Mode Temperature sensor type internal or external Start Mode Logger start modes Temperature Type Temperature type Celsius or Fahrenheit Multiple Start Stop Permit logger to be started or stopped for several times Start Delay Logger start delay time Pause Enable Disable Travel ID Travel DSC Travel description Highest Temperature Permit prohibit pause of logger Travel ID number Max temperature Stop mode set Stop mode setting value Lowest Temperature Stop mode actual Stop Time Min Temperature Actual stop mode Stop time Average Temperature Average Temperature Data points The total record pieces The total record time MKT Mean kinetic temperature Elapsed time Temporary PDF Permit to temporarily generate a PDF file after insert logger to computer Over A
7. larm 9 Single Alarm Alarm Zones Temperature Alarm Mode Ht Over 5 8 L1 Below Parameter information Device ID Data logger ID Travel ID Travel ID number Log Interval Record interval Time Zone Time Zone Cycle The total record time available Probe Mode Temperature sensor type internal or external Password setting password Start Mode Logger start modes Start time Auto start logger at set time Travel DSC Travel description Multiple Start Stop Permit logger to be started or stopped for several times Pause Enable Disable Stop mode set Stop mode setting Permit to temporarily generate a PDF file after insert logger to Permit prohibit pause of logger Temporary PDF computer Time zone setting not set alarm threshold Time zone No alarm setting Single alarm Set single alarm threshold one upper lower limit Set several alarm threshold Multiple alarm Battery display Battery seve Save parameters VE NE Back to home page g 5 Sensor adjustment page Temperature adjustment tempbase sensor Adjustment sensor adjustment In some cases you need to adjust the temperature sensor of the tempmate M1 logger to ensure the highest accuracy at custom temperature points Usually this is only necessary if the logger 15 very old and there was a normal sensor drift because of time or if yo
8. larm upper limit Below Alarm lower limit Alarm delay Alarm delay time Total time The accumulated alarm time The times alarm occurs Alarm events First triggered First alarm time Status Logger alarm status Data graph Summary lt gt 3 5 Threshold mod Below SpecialEvent 30 Apr 15 30 Apr 15 30 Apr 15 30 Apr 15 30 Apr 15 30 Apr 15 30 Apr 15 30 Apr 15 30 Apr 15 30 Apr 15 30 Apr 15 m 13 22 33 13 24 53 13 27 13 13 29 33 13 31 53 13 34 13 13 36 33 13 38 53 13 41 13 13 43 33 13 45 53 1 30 Apr 15 13 22 33 31 1 C About Help Function buttons cunve horizontally stretch Curve horizontally contract 8 cuve zoom in Threshold mod Curve zoom out Curve return to the original size Modify alarm threshold dynamically Mark 5 ELS uu function in the curve EN ave the marking in the curve opecialEvent Marking event display function Data table L2 4 Summary Time Eus Time Graph Time Table eae Time Download Save Data m 10 y Export Import 5 E Logger Setup
9. lay PAGE 1 Battery level current working status record stop etc upper lower limit status current temperature qe upper limit alarm occurs Y lower limit alarm occurs Page 2 Battery level current working status recording points PAGE 4 PAGE 3 mw GE 3 au battery level MAX battery level current 1 F current working ERIS NUM working status MAX 7 status Min AA temperature Page 5 upper limit 1 temperature Page 6 Setting temperature of upper limit 1 Page 7 upper Page 8 limit 2 Setting temperature of upper limit 2 e e Page 9 upper limit 3 Page 11 lower limit 1 Page 13 lower limit 2 Page 10 Setting temperature of upper limit 3 Page 12 Setting temperature of lower limit 1 Page 14 Setting temperature of lower limit exe
10. ll tempbase exe software insert logger to computer by USB port finish USB drive installation according to the prompt 2 Open tempbase data management software after connection logger with computer the data information will be automatically uploaded Then user could click Logger Setup button to enter parameter configuration interface and configure the parameters according to specific application 3 After finish configuration click Save button to save the parameter setting then it will prompt an interface of Logger Setup Completed click OK and exit from the interface Device operation instruction 1 Configuration operation Open tempbase exe software after connection logger with computer the data information will be automatically uploaded Then user could click Logger Setup button to enter parameter configuration interface and configure the parameters according to specific application After finish configuration click Save button to save the parameter setting then it will prompt an interface of Logger Setup Completed click OK and exit from the interface 2 Logger start operation M1 supports three start modes manual start start right now timing start the specific start mode is determined by the parameter setting Manual start press left key for 4s to start the logger Start right now Immediately start just after the logger disconnected with computer pu Ale des Timing start Logger starts when reaches to
11. r needs to configure the parameter again Note When the logger is connected to computer under the status of recording or pause status it is prohibited to plug off USB without battery power supply LCD display notice 1 Alarm LCD display When LCD display time is configured as 15s click left key LCD displays If over temperature incident occurs it firstly displays alarm interface for about 15 then skip to main interface automatically When display time is configured as forever If over temperature incident occurs it displays alarm interface all the time Press left key to skip to main interface When display time is configured as 0 there is no LCD display de Appendix 1 Working status description Device status LCD display Device LCD display status 1 Start 2 Start logger delay is flashing 3 Recording 4 Pause status During recording status in the in the middle of the first line middle of the first line static blinking display Wl display 5 MARK 6 MARK success failure 7 Device stop connection in the middle of the first line static display MI APPENDIX 2 other LCD display 1 erase data status 2 PDF 3 Alarm Only exceed upper limit generation interface status PDF file is under generation Only exceed lower PDF is in flash status limit Both upper and lower limit Occurs 231 Be Appendix 3 LCD page display PAGE Display disp
12. set start time Note The set start time needs to be at least one minute delay than current time Pause operation Double click left key to enter to pause status Under pause status the device only records time instead of temperature recording Double click left key again to cancel pause operation and recover to normal temperature recording Mark operation Double click right key to finish mark operation After finish marking operation if quickly finish pause and pause cancel action then the current marking could be canceled Note 1 For one recording trip the device could support Max 10 times data marking 2 Under status of pause or sensor disconnected status when external sensor is configured mark operation is disabled Stop operation MI supports two stop modes stop when reaches to Max record capacity manual stop and the specific stop mode is determined by parameter setting Stop when reaches to Max record capacity When record capacity reaches to Max Record capacity logger will stop automatically Manual stop the device only stops when it is manually stopped except that the battery 1s consumed out If the record data reaches to its Max Capacity then the data will be overwritten Note During the status of data overwriting MARK operation will not be zero cleared That 1s no matter how many times overwriting it has Max MRARK times is still be 10 times and every marking data will be saved without clearing
13. tempmate M 1 tempbase data management software User manual 1 Product overview tempmate M tempbase data management software could upload the recording data to computer and systematically analyze collect and manage data 2 Installation environment 2 1 Hardware environment CPU above PIIG00MHZ Hard disk above 40G Memory above 512M 2 2 Operation system Windows XP 32bit 64bit Windows Vista 32bit 64bit Win7 32bit 64bit Windows8 x86 x64 3 Main function 3 1 Main interface Device Information Serial Number Probe Mode Multiple Start Stop Internal ID Description TMM150412541 Internal Disable 0000000000001 Log Interval Start Mode Start Delay Temperature recording 15M 0S Right Now OD OM 05 Time Zone Temperature Type Pause Enable Disable UTC 00 00 F Disable Logging Summary Highest Temperature Lowest Temperature Average Temperature MKT Alarm Zone 0 0 F 0 0 F 23 8 F 24 0 F Alarm Delay Stop Mode Stop Mode actual Data Points Temporary PDF Total Time Manual Temporary 0 Disable No of Violations Start Time Stop Time Elapsed Time First Triggered 01 Jan 01 00 00 00 01 Jan 01 00 00 00 About Help Tool buttons Download recording data from logger Save Data Manually save data if current data is not saved into database then press this button to save data For first time recording data the system wil
14. u application temperature 15 near the min or max of the loggers temperature range 30 C to 70 C 22 F to 1587 F Please note Wse this feature only when serious deviations occurring The sensor offset can be done at your own risk and will effect voided warranty sensor adjustment Temperature adjustment range For Celsius 5 0 C 6 Export data page tempbase Export Data Import Data Export data in the format of EXCEL Export data in the format of PDF Export data in the format of ELT Restore insert ELT data to the software M1 multiple use PDF temperature data logger Product overview This data logger is mainly used to detect the temperature of food pharmaceuticals chemicals and other products during transportation or storage The main features of this product multiple use automatically generated PDF report high water proof level battery exchangeable Specification 80mm Length x 25mm Width 12mm Depth Technical parameters Temperature range 30 C 70 C Accuracy 40 5 20 40 C 1 C other range Resolution 0 1 C Record capacity 32000 MAX Battery lifetime 25 C if record interval 15minutes lifetime at least 6 months Waterproof level IP67 Report type Encrypted PDF file Data connection port USB Sensor type Internal External optional Power supply Internal CR2032 battery Operation system WIN XP 7 8 Initial use 1 Insta