Home

OPC Server FibroLaser III

image

Contents

1. Add and Remove buttons For each subsystem OTS you must fill out the section connection and the section Zone Connection The connection section allows configuring information regarding the OTS30xx communication parameters Solutions and Innovative Systems SUBSYSTEM 4a 1 l h EXAMPLE SUBSYSTEM_1 O Serial interface Ethemet 192 128 88 213 Image 17 Configuration SUBSYSTEM Connection e Description Is the description of the subsystem OTS At the sturt up the OPC Server creates by default one subsystem which description is set to EXAMPLE The description can be freely modified e TAG Name The TAG name is used to identify the subsystem OPC TAG The default value is SUBSYSTEM_ ID OPC Server FibroLaser IIT Installation and Configuration Manual V1 0 Pag 19 Se Innovative Software Solutions and Engineering Services Pi e Ethernet IP Address IP address of the OTS30xx to be connected The default is 127 0 0 1 localhost Port Port number of the OTS30xx to be connected The default is 1234 Serial Interface Ethemet Ethemet Properties IP Address 127 0 0 1 Port 5000 lt e Serial Interface Port Name Port Name of the OTS30xx to be connected The default is COM1 Baud Rate Baud Rate of the OTS30xx to be connected The default is 19200 Data Bits Data Bits of the OTS30xx to be connected The default is 8 DTR Enable DTR Enable of the OTS30x
2. OPC SERVER Image 1 Register and UnRegister e To register the Server you must click Register in the menu Server e To unregister the OPC Server you must click UnRegister in the menu Server OPC Server FibroLaser IIT Installation and Configuration Manual V1 0 Pag 6 ee Innovative Software Solutions and Engineering Services ff 5 2 Authentication and Permissions After OPC Server registration the COM security has to be enabled so OPC Client can automatically call the OPC Server Below are showed all steps needed to enable the security COM using DCOMCNFGI 1 Verify that the DCOM security registration was executed successfully 2 Run DCOMCNFG Only the administrator can run Dcomcnfg exe To use RUN Command Windows or Command Prompt to open DCOMCNFG program Ms 8 8 8 6 txl Type the name of a program Folder document or Internet resource and Windows will open it For you Open v Cancel Browse Image 2 DCOMCNFG Run 3 Locate the My Computer item by expanding the following nodes Component Services gt Computers 4 Right click My Computer and select Properties Component Services l8 x My Computer 4 object s Component Services 6 Computers fia fea Gj Event Viewer Local Stop MS DTC DCOM Config Services Local Refresh all components view New Window from Here Processes Properties Opens property sheet for tH Image 3 Comp
3. 10 Connection State T SUBSYSTEM_1 SoftwareVersion STRING 10 SoftwareVersion T SUBSYSTEM_1 ControllerAddress INT16 10 ControllerAddress E SUBSYSTEM_1 MeasurementState INT16 10 MeasurementState T SUBSYSTEM_1 FibreBreak INT16 10 FibreBreak E SUBSYSTEM_1 Output Output_1 INT16 10 Output_1 T SUBSYSTEM_1 Output Output_2 INT16 10 Output_2 Li SUBSYSTEM_1 Output Output_3 INT16 10 Output_3 T SUBSYSTEM_1 Output Output_4 INT16 10 Output_4 PVSS DPE n Description Name System_stat System_status_update s Date_XML_U Date_XML_Upload License_Sta License_State Configured Configured D D PortState PortState Connection Connection State SoftwareVe SoftwareVersion ControllerAd ControllerAddress Measuremen MeasurementState FibreBreak FibreBreak Output_1 Output_1 Output_2 Output_2 Output_3 Output_3 Output_4 Output_4 The SUBSYSTEM section allows to define the number and properties of the subsystems OTS 30xx to be connected to the OPC Server SUBSYSTEM t fia ap ce Add New The Add New button is used to add new subsystem while the button Remove remove it OPC Server FibroLaser IIT Installation and Configuration Manual V1 0 Pag 18 SS Innovative Software Solutions and Engineering Services The arrow buttons allow selecting the subsystem to configure The number on the left represents the subsystem to be configured while the number on the right represents the maximum number of subsystems defined with the
4. GE Innovative Software Solutions and Engineering Services f 7 l Installation and Configuration Manual OPC Server FibroLaser III Installation and Configuration Manual Revision History Version Date Status 1 0 Sep 2015 Released Property of S4S Innovative Software Solutions and Engineering Services We reserve all rights in this document and in the subject thereof By acceptance of the document the recipient acknowledges these rights and undertakes not to publish the document nor the subject thereof in full or in part nor to make them available to any third party without our prior express written authorization nor to use it for any purpose other than for which it was delivered to him BB innovative software solutions and Engineering IC_OPC Server FibroLaser IIl Doc n IC 001 015 V1 0 Updated Sep 2015 Specifications subject to change without notice Please visit our website for the most up to date product information www s4s it All Rights Reserved SAS Via Vespucci 6 20018 Sedriano MI Italy VAT 05172500968 Tel 39 3939505055 Fax 39 02 36547223 Email info s4s it A Innovative Software Solutions and Engineering Services Table of Contents E Eo E N E E E N E dmiaetacieadchewdarancimceetees 3 PE iai iiao U e Na A NEE A E E 3 3 About the OPC Server FibroLaser Uy ysis itsacsancrautadancanutyidengbaaanancan Auleediantenaeaeas 4 A System REQuirementeccc cee acecaddnacacnndsaucndudaaddaddiu
5. MOUS LOGON Everyone Check Names oK Caoa A Image 10 DCOMCNFG Add users e Provide all permission to added users 9 Set OPC Server identity Select the identity tab Set This user and insert User and Password used to access MM8000 General Location Security Endpoints Identity Which user account do you want to use to run this application The interactive user The launching user This user User DMse000 Browse Password eveeeeeene Confirm password eveecesees The system account services only Cancel Apply Image 11 DCOMCNFG Identity Note The demo version runs only with Launching or Interactive User A different user from Launching or Interactive can be used ONLY if the OPC Server runs with a registered PAK OPC Server FibroLaser III Installation and Configuration Manual V1 0 Pag 11 ee Innovative Software Solutions and Engineering Services PA 5 3 Licensing To run the OPC Server without any time restriction a regularly software license has to be purchased from SAS A software license defines the maximum configuration managed by the OPC Server in terms of N of FibroLaser III controllers OTS30xx N of channels per OTS30xx Optic fibers Length of Optic Fiber 1 2 4 6 10 Km per OTS30xx Without the software license the OPC Server FibroLaser II runs in demo mode with full functionality for two hours The demo mode runs only with Launchi
6. WN VALUE If OPC Server does not receive the state of one tag set the tag value with Default Value TAG defined in Settings configuration if the type tag is a integer else if the type is a string set value with OPC Server FibroLaser IIT Installation and Configuration Manual V1 0 Pag 26
7. an communicate with these systems on behalf of Clients Application Name OPC FibroLaserlll exe OPC NAME S4S OPC FibroLaser III Can be configured in xml file OPC DESCRIPTION OPC Server FibroLaser III Can be configured in xml file OPC GUID 4DA870F2 A36A 46FF BD36 A21511B9FF80 OPC Server FibroLaser IIT Installation and Configuration Manual V1 0 Pag 4 ee Innovative Software Solutions and Engineering Services 4 4 System Requirements The OPC Server FibroLaser III application runs on any hardware which supports Windows Server 2003 2008 2012 Windows XP Windows 7 or Windows 8 with DCOM Visual C 2010 Redistributable Packages and NET Framework 4 Installed The system must have 10 Mb of free disk space to install the program and 1 Gb of free memory is required to load and run the application All systems information is stored in the server s disk For configuration purpose a monitor connected to the computer is required The OPC server is a 32 bit application which runs on both 32 64 bit operating systems Hardware characteristics recommended CPU i5 high end for example INTEL Core i5 4690K or i7 mid range for example Intel Core i7 4770K RAM 8GB Checks on the network Since the Server communicates with the FibroLaser OTS 30XX over TCP IP an Ethernet network must be in place The network itself should be fully tested and be known to operate before attaching the controllers and the Server computers Co
8. cent triggering locations are transmitted only as Connected Disconnected a OPC Server FibroLaser IIT Installation and Configuration Manual V1 0 Pag 24 wE Innovative Software Solutions and Engineering Services start and end position In that case the end position is transmitted as a negative number Hae Pe mgd ta r ve oe FireDirection Fire direction state Intl6 R Fire moving towards fiber end Fire moving towards controller COMMANDS Avatage Zone Temperature Request Command Command Intl6 R W Maximum Zone Temperatures E ea Minimum Zone Temperatures 22 Request E E a Starting position of the zone in SP Float meters a End position of the zone in meters Float Co o Alarm state R W COMMANDS Acknowledge o Nom Seer Prealarm state R W COMMANDS Acknowledge ee any Fault state R w __ COMMANDS Acknowledge List of meter positions of alarm triggering locations along the zone In order to reduce the amount of ZoneAlarmPositions Alsen Trisoetine Locat R data adjacent Sin nae nage Scene triggering locations are transmitted only as start and end position In that case the end position is transmitted as a negative number OPC Server FibroLaser III Installation and Configuration Manual V1 0 Pag 25 Se Innovative Software Solutions and Engineering Services A LICENSE NOTE If the license is installed but covers fewer tags than configured tags unlicensed assume the default value 100 UNKNO
9. e subsystems FibroLaser III controllers that the OPC Server has to connect OPC Server FibroLaser IIT Installation and Configuration Manual V1 0 Pag 15 SS Innovative Software Solutions and Engineering Services SETTINGS The SETTINGS section allows configuring the OPC Server name and description and the main operating parameters Solutions and Innovative Systems OPC SERVER OPC Name S45 OPC Fibrol_aserill OPC Description S4S OPC Server Fibrolaser Ill 9 _Un Regiter x7 Register Operating Parameters OPC Quality behavior Enable os System Status Update a 2 2 Level Log Ostal Low Number Retry Meg 5 Defaut Value TAG 1 r3 Path Company image Defaut teed Detour g eenean FibroLaseritt x go ienas FibroLasertil Delimiter Epon CSV file F Export Full CSV file i Download JE Gose Image 16 OPC Server SETTINGS OPC Server After entering the OPC Server name and description you must register the application with the command Register In case you want to change the name and description you must first unregister it then register it again with the new name Operating Parameters e OPC Quality behavior Enables or disables the management of the quality property in accordance with the standard OPC Default is Enabled e System Status Update 5 Polling delay in seconds for updating the OTS 30xx status Range Value 1 3600 s Default value 3 s OPC Server FibroLa
10. ect Linking and Embedding OLE for Process Control OPC S4S s OPC Server is a software package that operates as an OPC driver of Siemens Management stations as MM8000 Desigo CC and Cerberus DMS The OPC Server meets the latest standard of OPC DA2 0 that allows connections to various kinds of devices and host OPC machines The manual is organized to provide an overview of OPC technology detailed information on the configuration environment and a complete list of OPC Tag s provided by the OPC Server OPC Server FibroLaser IIT Installation and Configuration Manual V1 0 Pag 3 Se Innovative Software Solutions and Engineering Services JS 3 About the OPC Server FibroLaser III The OPC Server FibroLaser III is based on OPC Data Access known as DA which provides real time data from FibroLaser III controllers to management stations with OPC client drivers as MM8000 DesigoCC and Cerberus DM The server communicates with OTS 30xx via the LON protocol over TCP IP Protocol has been designed to be compatible with the previous versions of the OTS public code protocols The OPC Server reads and writes data to and from FibroLaser III controllers via Ethernet The Server has a graphical user interface GUI configuration environment with an Explorer look and feel The configuration environment allows the Server to be configured with information such as controller IP addresses and available global variables so that the Server c
11. figuration The purpose of this section is to provide the necessary information for configuring the FibroLaser III controller and the OPC Server 6 2 1 FibroLaser III controller OTS30XX To enable the communication with the OPC Server the OTS30xx has to be configured setting connection parameters and enabling the LON protocol The following screen shows how to configure the OTS30XX via Fibro Manager windows application Device EL Event Configuration sh Network Settings 2a LON Protocol gy Other Protocols RB Locked mode Image 12 FibroLaser III Communication Settings In the Network Settings section it is possible to set the OTS30XX IP address This IP address will be used by the OPC Server configuration tool to connect the FibroLaser II controller V Get NTP configuration from DHCP C Manual IP address IP Address CEEE Subnet Mask zs 255 2585 0 C Disable Ethernet Interface Image 13 FibroLaser III Network Settings OPC Server FibroLaser III Installation and Configuration Manual V1 0 Pag 13 Se Innovative Software Solutions and Engineering Services In the LON Protocol section to enable the LON Protocol select the check box Use TCP and then set the communication Port The value of the Port will be set in the OPC Server to connect the OTS30xx In the transmitted data section is possible to define which data type the OTS30XX has to be transmitted Notices Alarms Alarm locati
12. ng or Interactive User see OPC Server identity 9 5 3 1 How to obtain a license A software license must be obtained from S4S and the request has to be done from the computer where is installed the OPC Server From the its User Interface selecting then Information about OPC Server FibroLaser III then View license then Product activation In the Product Activation the following fields have to be filled e Customer installation data o User name o Organization o Email e OTS 30XX configuration in terms of numbers of FibroLaser III controllers numbers of channels for controller and fiber length per channel e Code generation via the Generate new user code button e Save the code and directly send it to orders s4s it or send it via Send button if it is configured a mail box on the computer A PAK Program Authorization Key code will be generated for that specific configuration and for the PC from which has been requested the software license 5 3 2 Software license activation To activate your license you must access to the Product Activation dialog and through the Load New License button you load the license file released by S4S A dialog will appear for feedback at the end of loading to indicate the outcome of activation OPC Server FibroLaser IIT Installation and Configuration Manual V1 0 Pag 12 wE Innovative Software Solutions and Engineering Services 6 System Con
13. ntact your system administrator for assistance or consult instructional documentation and manuals to setting up the network It is beyond the scope of this Users Manual to discuss networking topics in any detail Once the network is in place and the Server computers and controllers are attached check connectivity using available network testing tools and programs such as ping command Note When the OTS 30XX configuration is modified a re start of the LON Protocol is carried out and a disconnection on communication is detected OPC Server FibroLaser IIT Installation and Configuration Manual V1 0 Pag 5 ee Innovative Software Solutions and Engineering Services S 5 Installation guide Before installation of the OPC server make sure it is installed the Visual C 2010 Redistributable Packages if not please let install it on your computer The OPC Server FibroLaser II is provided with own specific setup The setup includes all the dependencies ex WtOPCSvr DLL OPC server library in order to ensure the proper functioning of the application e S4S OPC Library dll e 4SGenCodelnfo dlll e 4SGenCodeinfoLibrary dll e ObjectlistView dll e WtOPCSvr dll e SysiInfo dll Two security issues require attention e Installation needs Administrator rights e Windows Firewall must be configured e DCOM security settings must be configured This guide describes how to make the necessary settings 5 1 Registration of the OPC Server d
14. ommand Command 0 SUBSYSTEM_1 FIBRO_CHANNEL_1 ZONE_UKNOWN Name Name 0 SUBSYSTEM_1 FIBRO_CHANNEL_1 ZONE_UKNOWN Alarm Alarm 2 SUBSYSTEM_1 FIBRO_CHANNEL_1 ZONE_UKNOWN Prealarm Prealarm 3 SUBSYSTEM_1 FIBRO_CHANNEL_1 ZONE_UKNOWN Fault Fault 4 Whether is checked the CSV export file contains the following data for DesigoCC PVSS DPT name System_status_update GMS_OPC_MultiStateinput GMS_OPC_MultiStateinput GMS_OPC_MultiStateinput GMS_OPC_MultiStateinput GMS_OPC_MultiStateinput GMS_OPC_MultiStateinput GMS_OPC_MultiStateinput GMS_OPC_MultiStateinput GMS_OPC_MultiStateInput GMS_OPC_MultiStateinput GMS_OPC_MultiStateinput GMS_OPC_MultiStateInput GMS_OPC_MultiStateinput GMS_OPC_MultiStateinput GMS_OPC_MultiStateinput Server Data S Server name DB element Progid Description Name opc_3 server Fibrolaserlll OPC_Server 4DA870F2 A36A 46FF BD36 A21511B9FF80 S FibroLaserill 4S 0PC FibroLaserill S4S OPC Ser FibroLaserillOPC_Server Groups Data G Group name DB element Description Name G Zones Zones Zones Tag Data T Tag name Type Direction PVSS DP name T SETTINGS System_status_update s INT32 10 T SETTINGS Date_XML_Upload STRING 10 Date_XML_Upload T SETTINGS License_State INT16 10 License_State T SUBSYSTEM_1 Configured INT16 10 Configured T SUBSYSTEM_1 Description STRING 10 D T SUBSYSTEM_1 PortState INT16 10 PortState T SUBSYSTEM_1 ConnectionState INT16
15. onent Services Property 1 Dcomcnfg exe provides a user interface for modifying certain settings in the registry By using Dcomcnfg exe you can enable security either on a computer wide or a process wide basis You can enable security for a particular computer so that when a process does not provide its own security settings either programmatically or through registry values the values set by Dcomcnfg exe will be used Or you can use Dcomcnfg exe to enable security for a particular application only NoteYou must be an administrator to run Dcomcnfg exe OPC Server FibroLaser IIT Installation and Contiguration Manual V1 0 Pag 7 E Innovative Software Solutions and Engineering Services 5 Go to the COM Security tab Edit the default settings to Access Permission hereby adding ANONYMOUS LOGON and Everyone and giving all access permissions to that group of users Repeat the setup for the limit settings My Computer Properties Gereral Options Delauk Pr Defauk Protocols MSOTC COM Secuny You may edk who is alowed default access to appbcations You may also set ims on appbcations that detemine thes own permissions ian Launch and Activation Permissions You may edk who is allowed by deflank to lsunch spphcstions or activate obyects You may alto set limits on applications that determine thes own permissions Eda Limts Edt Defak Image 4 COM Security Access Permissions 6 Now edit the default settings for La
16. ons Zone Minimum temperature Zone Maximum temperature Zone Mean temperature Temperature data and backscattering data For MM8000 Danger Management System is sufficient to enable the following data Notices Alarms and Alarm locations for system as Desigo CC Cerberus DMS WinCC and SCADA can be enabled the following data Notices Alarms Alarm locations Zone Minimum temperature Zone Maximum temperature Zone Mean temperature Temperature data Transmitted data setting for MM8000 W 3286 40N 2 OTS3 TC S000 V E Notices va Alarms v E Alarm locations Zone minimum temperature E Zone mean temperature m Zone maximum temperature Temperature data Backscattering data 00000 im a a Image 14 FibroLaser LON Protocol Transmitted data setting for MM8000 OPC Server FibroLaser II Installation and Configuration Manual V1 0 Pag 14 Se Innovative Software Solutions and Engineering Services Transmitted data setting for DesigoCC Desigo Insight SCADA Image 15 FibroLaser LON Protocol Transmitted data setting for DesigoCC 6 2 2 OPC Server After a successful installation the OPC Server has to be configured in order to communicate with the OTS 30xx and acquire data from it The OPC Server FibroLaser III configuration tool consists of two sections Settings and Subsystems e SETTINGS Is the section where to define the OPC Server general parameters e SUBSYSTEMS Is the section where to configure th
17. ownload button to make active the new configuration Selecting the button Close without carrying out the command Download data is lost OPC Server FibroLaser IIT Installation and Configuration Manual V1 0 Pag 22 OPC Server FibroLaser IIT 7 OPC TAGs Se Innovative Software Solutions and Engineering Services The following list introduces each tags in the OPC structure with a brief description DESCRIPTION PROPERTY OPC Server FibroLaser III System_status_update s System Status in seconds Date last upload configuration data y Date_XML_Upload xml file License_State Indicates the status of the license If the license is installed but covers fewer tags than configured tags unlicensed assume the default value 100 Subsystem Configured in xml file If the subsystem is configured implies that opc tags ate not updated To configure a subsystem you need to change the description and do not let EXAMPLE 1 1 N General Fibre Break state NoFibreBreak Output_ 0 n Output State AS aii 1 3600 1 Int16 2 Demo Version Expired l ES Installation and Configuration Manual V1 0 VALUE DESCRIPTION Default value 2 s DD MM YYYY hh mm ss Unknown Demo Version starting Demo Version running Licensed Configured Not Configured Disconnected None of the fibres involved in the active measurement sequence including spares exhibits a fibre break There is one or more fib
18. ransmitted by the OTS30xx Temperature date can be visualized in a chart that can be activated by the User Interface menu OPC Server FibroLaser III Installation and Configuration Manual V1 0 Pag 21 ee Innovative Software Solutions and Engineering Services ral Zones Connection Zone ZONE GENERATION FIBRO CHANNEL q Fibre Length 1000 00 Generate Zones LIST OF GENERATED ZONES Zone Index Zone Name Zone Start Zone End 1 Zone 1 0 00 2 Zone 2 100 00 3 Zone 3 200 00 4 Zone 4 300 00 5 Zone 5 400 00 6 Zone 6 500 00 7 Zone 7 600 00 Image 18 Configuration SUBSYSTEM Zone This section allows to configure the zones for each fiber connected to the OTS30xx In the upper part of the section it s possible to select the fibro channell using the left right arrow Once selected the fibro channell proceed defining the associated zones Zones are generated automatically by the system on the basis of the following data provided by the Fibro Manager Fiber length mt is the length of the optic fiber cable defined by the Fibro Manager in the section Zone configuration effective fiber length see the right upper part of the screen Number of zones or Length of zones These data comes always from the Fibro Manager section Generate Zones Once the zone configuration for each fibro channel is complited select the D
19. res involved in the active measurement sequence including spares exhibits a fibre break Active Inactive Pag 23 E Innovative Software Solutions and Engineering Services ExplosionProtection 7 3 P Explosion protection state Systems without explosion protection option Intl6 R 1 Explosion protection circuit is installed o Soma KeySwitch Key switch state Int16 R Test Mode position EEE SystemFault System fault state Intl6 R W o ream CommonAlarm Common alarm state Int16 R W InternalDeviceTemperature Internal device temperature in C AES InternalDeviceHumidity Internal device humidity in rel u n e devicei PE ey humidi Float R an internal humidity sensor the marae value is always Unknown Volt aco No synchronised No synchronised with NTP server NTP server ClockSynchronised State of controller s clock Intl6 1 Synchronised with NTP server LastUpdate Data Last Update ee COMMANDS Alarm Triggering Locations Request Alarms Request Software Version Request Command Command SUBSYSTEM Intl6 R W Attendance Check Request Controller Address Request Device Status Request Date And Time Request Acknowledge Reset all Normal NoFibreBreak Fibre Break state Fibre Break Normal Alarm Alarm state COMMANDS List of meter positions of alarm triggering locations along the FibreAlarmPositions Alarm Triggering Locations sensor fibre In order to reduce the amount of data adja
20. rm tag is set to a value active the pre alarm tag of the same zone is set to a value no active Default value FibroLaserlll Ack Reset behavior Defines how to handle the event status of an OPC tag value FibroLaserlIIl The OPC tag value takes the value sent by the FibroLaserlll O no active 1 active Ack Reset The OPC tag value is set in accordance to the Ack and Reset commands sent to the OTS Es 0 event not active 1 event active 2 event silenced Ack command sent and ready to be reset After the command reset the value return to the value 0 Default value FibroLaserlll Delimiter Export CSV file Defines the delimiter character used in the CSV file Default value OPC Server FibroLaser III Installation and Configuration Manual V1 0 Pag 17 E Innovative Software Solutions and Engineering Services e Export full CSV file Whether NOT checked the CSV export file contains the following data Full Tag name Tag description text OPC Class SUBSYSTEM_1 FIBRO_CHANNEL_1 Connection Connection 1 SUBSYSTEM_1 FIBRO_CHANNEL_1 FibreBreak FibreBreak 5 SUBSYSTEM_1 FIBRO_CHANNEL_1 Alarm Alarm 2 SUBSYSTEM_1 FIBRO_CHANNEL_1 FibreAlarmPositions FibreAlarmPositions 8 SUBSYSTEM_1 FIBRO_CHANNEL_1 FireMagnitude FireMagnitude 0 SUBSYSTEM_1 FIBRO_CHANNEL_1 FireDirection FireDirection 0 SUBSYSTEM_1 FIBRO_CHANNEL_1 ConfigurationAligned ConfigurationAligned 7 SUBSYSTEM_1 FIBRO_CHANNEL_1 C
21. ser IIT Installation and Configuration Manual V1 0 Pag 16 ee Innovative Software Solutions and Engineering Services F Level Log Detail Defines the level of detail of OPC LOGs presented on the screen Three levels are supported LOW MEDIUM and HIGH LOW Default value Presents the system diagnostics and commands received from an OPC client MEDIUM Presents all OPC transactions change of status commands diagnostics HIGH Presents all OPC transactions change of status commands diagnostics with the native messages sent by the OTS The detail level is verbose and can slow down the application Normally used only for Debug All logs are saved on a File txt C OPC FibroLaser LOG Number Retry Msg Number of polling messages sent to the OTS30xx without any response before to set the communication status to disconnected Range Value 1 50 Default value 5 Default Value TAG Default value assigned when the OPC Server does not know the real value of TAGs for example at the start up of the OPC Default value is 1 Path logo image Defines the logo to be presented on top of the application Defaul value S4S logo Alarm Prealarm behavior Defines how to handle the zone alarm and prealarm OPC tags FibroLaserlIIl The alarm and pre alarm value are aligned with the value sent by the FibroLaserlll so you can have both alarm and pre alarm active Alarm Prealarm In this case when a zone ala
22. t must be the same as configured in the xml file Xml file example lt OPC_PROTOCOL Delimiter OPC_name OPC SERVER OPC_description OPC Server Fibro Laser gt OPC Server name is registered OPC Fibro Laser for this example the name is OPC SERVER Component Services 5 x File Action View Window Help 184 xi 9 om xene mA gt Console Root B Component Services Computers a My Computer E COM Applications NetMeeting Network Network Nms Simula 3 DCOM Config Crawler Provisioni Distributed Transactic E Running Processes i EA Active precy Users and Comp Passport Passport f Event Viewer Local Admin Class Manager Services Local Vi Properties PenIMC2 PrintFilterPi RDSessMar RDSHast gt zl Image 7 DCOMCNFG Find OPC Server OPC Server FibroLaser IIT Installation and Configuration Manual V1 0 Pag 9 E Innovative Software Solutions and Engineering Services a 8 OPC Server Configuration Permissions Select the OPC SERVER registration then the properties pushing the right button and then select the security tab a Select Customize in the Configuration Permissions and then click the Edit button General Location Security Endpoints Identity M Launch and Activation Permissions Use Defa
23. uaudaumanuceanunaeae 5 5 nstallati INES seereis esee sniawescetoriaerce nese aioacnesernaac nem eeeetet emanations 6 5 1 Registration of the OPC Server acciceceesceccaeeccuvscecetetestundecccepchscens descents ceoadean sidecendectcseceeceaventestele 6 5 2 Authentication and PermissionS sssssssssssesttstssteseeeeeeesssssssssssssssssssssssssssssssettnrtrrtrtteeteeeeeeeresssssss 7 ae CENS NJenssinsnenissniininn nna a A AER E 12 5 3 1 How to btaina license cease crcaecr eReader cna esate ented wi ia 12 5 3 2 Software license activations eiA iii 12 6 System Copfig ratiO Misses e EEE E EREA 13 6 2 1 FibroLaser IN controller OTS3OXX c cccccscssesssscsssssssesssssscsssssssssssssssssesessesesscsssecsssssscsssensseseesees 13 6 2 2 OPC ET VEN aee a E REE E A ERR O E 15 Ta SOP CT AGS cca cicssahessaaa incision GR RR 23 OPC Server FibroLaser IIT Installation and Configuration Manual V1 0 Pag 2 wE Innovative Software Solutions and Engineering Services 1 Glossary Acronym Description OPC OLE for Process Control OLE Object Linking and Embedding GUI Graphic User Interface SCADA Supervisory Control And Data Acquisition FibroLaser III Siemens Linear Heat Detection systems OTS30xx Siemens Linear Heat Detection Controllers 2 Introduction This is a User Manual for the OPC Server FibroLaser III The Server communicates with FibroLaser II controllers over Ethernet and supports data exchange with Client s via Microsoft s Obj
24. ult Customize Edit i m Access Permissions Use Default Customize Edit i M Configuration Permissions Use Default Customize Edit Caneel snow Image 8 DCOMCNFG Configuration Permissions b Select Add button to add a new user and then in the new form select the Advanced button c Click the Find button to search the everyone and then ANONYMOUS LOGON users Select Users or Groups ji 21x Select this object type Users Groups or Built in security principals Object Types Erom this location FTS Rv_1 Locations Common Queries Name Starts with z l Columns Description Starts with Find Now T Disabled accounts Stop F Non expiring password Days since last logon z 29 Search results Name RDN B Administrators F4NONYMOUS LOGON E Authenticated Users ET Rackun Onerators FT SRV 1 z Image 9 DCOMCNFG Find User In Folder FT_SRV_1 OPC Server FibroLaser II Installation and Configuration Manual V1 0 Pag 10 lt 4 5 Innovative Software Solutions and Engineering Services a d Add everyone and ANONYMOUS LOGON user Select Users or Groups 2 x Select this object type Users Groups or Built in security principals Object Types From this location Fs Rv_1 Locations Enter the object names to select examples ANONY
25. unch and Activation Permissions hereby adding ANONYMOUS LOGON and Everyone and giving all access permissions to that group of users Repeat the setup for the limit settings My Computer Properties General Options Launch Permission Defaut Protocols i MSDTC j COM Secunty Access Permissions You may edit who is allowed defaut access to applications You may also set imits on applications that determine ther own peemissions Ect Liens Edt Defaut Launch and Activation Peemissions Ay A an a aktra bee ner o Aa penea e OAA COA deve RE SORORE Na ovm peemessions T C Image 5 COM Security Launch and Activation Permissions The new settings will take effect when the OPC Client has been restarted Therefore close the Component Services dcomcnfg program and restart the OPC Client application OPC Server FibroLaser IIT Installation and Configuration Manual V1 0 Pag 8 E Innovative Software Solutions and Engineering Services 7 Using tree view DCOMCMFG to check the all DCOM registered Component Services p File Action view Window Help e m x Tele ma Aln Console Root 5j B Component Services G Active Directory Users and Comp E Event Viewer Local E Services Local gt E Image 6 DCOMCMFG Select the Component Services item than Computers than My Computer and DCOM Config item Find the OPC Server name registered in the DCOM list i
26. x to be connected The default is true Flow Flow of the OTS30xx to be connected The default is None Parity Prity of the OTS30xx to be connected The default is None Stop Bits Stop Bits of the OTS30xx to be connected The default is One Serial Interface Ethemet Serial Interface Properties Port Name COM1 v DTR Enable tue v Flow None v Baud Rate 19200 v Parity TEE Data Bits 8 v Stop Bits One v OPC Server FibroLaser IIT Installation and Configuration Manual V1 0 Pag 20 E Innovative Software Solutions and Engineering Services Pa iran Temperature Subsystem 1 EXAMPLE x amp Fibro Channel Fibro Channel 1 7 80 60 O 40 E 20 2 0 20 40 0 200 400 600 Fibro Location m LON ID The LON addresses are used to identify the OTS controllers in a network structure Note that each LON address MUST be unique in each network segment Range value 1 255 LON address 1 which has been used to identify Charon3 is not used for OTS3 LHD3 system Default value 2 Fibro Channels Number of the OTS30xx Fibro Channels configured by the Fibro Manager Range value 1 48 Deafult value 1 Outputs Number of Outputs configured in the OTS30xx by the Fibro Manager Range value 0 112 Default value 10 Inputs Number of Inputs configured in the OTS30xx by the Fibro Manager Range value 0 112 Default value 4 Temperature data Whether checked enables the reading of temperature data t

Download Pdf Manuals

image

Related Search

Related Contents

Resolver-to-Digital Module  Perfil de Competencia Laboral - Secretaría Técnica de Capacitación  ColdMachine Serie 90  AWA-3204  GE Monogram Built In 36 Single Door Refrigerators and 36 Single Door Freezers Refrigerator User Manual  Istruzioni per l`uso dei bollitori delle serie PSM, PSR  

Copyright © All rights reserved.
Failed to retrieve file