Home

USER`S MANUAL

image

Contents

1. Description Tare Set the display to zero by storing the current weight in the tare memory On Zero Off Turns the scale on zero or off Units Select kilograms pounds or ounces Hold Temporarily memory the weight Place an item to be weighed on the platform Press HOLD key the arrow of the left bottom will blink The display shows the measured weight After removing the item the display still shows the weight Press HOLD or TARE button to disable HOLD function Turn the scale on using the On Zero Off key After the display is at zero place an item to be weighed on the platform The display will show the weight The unit will be shown in kilograms unless the user has selected either pounds or ounces previously If an empty container is used the weight can be ignored by zeroing the display To zero the display press the TARE key Then when material is placed in the container only the weight of the material will be shown 2 3 Insert the male plug into the stainless steel stick which will be screwed into the hole between the two sides of holes of platform See figure 3 DL D DD Male plug Figure 3 The Procedure of Fabricating for MS2500 1 Put the four adjustable feet into each of hole which rear of platform See figure 1 2 Screw two stainless steel sticks into two sides of platform See figure 2 Figure 1 Figure 2 6 DISPLAY SYMBOLS ee Description
2. Manufacturer s Declaration of Conformity This product has been manufactured in accordance with the harmonised European standards following the provisions of the below stated directives Electro Magnetic Compatibility Directive 89 336 EEC Low Voltage Directive 73 23 EEC Marsden Group Holding Ltd USER S MANUAL 4 Connect the male plug with the female e POWER SUPPLY connector which placed in platform The MS2500 scale uses rechargeable battery pack or 15V A 300mA DC adaptor See figure 4 kats A v Low battery indication will display on LCD display when rechargeable battery s power is insufficient to power the EERE scale When E is displayed plug in the DC adaptor for operations and recharge e DC ADAPTOR OPERATION i Note Always fit the Adaptor to the scale BEFORE connecting to an electrical outlet Disconnect from the electrical outlet BEFORE disconnecting the adaptor from the scale e SPECIFICATIONS Den plug gt Model MS 2500 NS Maximum Capacity 300 kg 660 Ib Separation division 100 g 0 2 lb Weight unit Kg Lb oz o Power Supply Rechargeable battery pack 15V 300mA DC adaptor Operation Temperature N 5 C 35 C Figure 4 Dimensions 550 x 550 x 940 mm Display 1 0 LCD display with 4 1 2 active digits Key Functions ON ZERO OFF TARE UNIT HOLD FUNCTION KEYS ON HOLD UNIT ZERO TARE OFF
3. scale in auto zero range indication accurate zero result is stable kg Ib or oz scale in weighing mode Lo bAt Battery is weak after 5 minutes the scale will turn off d Show the Net Weight is being display NW or the Gross Weight is displayed GW e CALIBRATION Occasionally the scale should be verified that it is weighing correctly by measuring a known mass of approximately the scale capacity Tare the scale place the mass on the center of the platform and note the reading Calibrate the scale if necessary Before beginning make sure you have the mass specified and you know the mass is accurate e PROCEDURE Turn the scale off Press and hold the On Zero Off key then press the Units key 3 times Release the ON Zero OFF key The display will show the gravity value of the factory 9 789 Press the Tare key to move to the desired digit and press the Units key to set the gravity of destination Then press the Tare key to confirm the entered gravity Display will show zero Place the calibration weight below on the scale centered on the platform MS2500 300kg mass Press the Tare key again The display will show CAL then return to weighing showing the value of the weight used Remove the weight Verify the scale is calibrated correctly 3 e SET FUNCTIONS The scale can be set as desired for the user The settings that can be changed are Weighing Units enabled Time delay before the scale automa
4. ick which between the two sides of sticks firstly And then put the other two bars into the sticks separately See figure 4 The fabricating is completed See figure 5 Figure 5 1180 B Sweeten Creek Road Asheville NC 28803 828 274 3730 800 441 5761 Fax 800 444 9989 www weighsouth com
5. tically turns off Access to some service parameters Contact your dealer for more etails Press and hold the TARE key for 3 seconds until the display shows Set then the first menu option Unit Press the Unit key to cycle through the options SEt Unit gt A off gt CAP gt CAL gt DIV gt GRAV BMI TR lt TRAN At each option press the Hold key to enter the functions and then press the Unit key to see the options pressing the Hold key again to return to the functions menu Each weighing unit can be enabled or disabled Unit kg e L oz st y y v y on gt or 4 The Automatic Turn off time can be set or disabled off y Seconds delay until turn off Each BMI can be enabled or disabled BMI por an The other functions do not apply to the users Advance to END in order to exit the menu If you need use BMI be sure that you set BMI on and go to END first Press HOLD key for 3 seconds to set height centimeter In height setting mode press HOLD key to move to next digit press UNIT key to set numeral 0 9 biggest 199 99 Press TARE key to return normal mode when complete height setting Press Hold key one time to enter BMI mode Step on the platform The scale shows weight value and then shows BMI value Press HOLD key to disable BMI feature 5 Insert the three bars of indicator head into the three sticks Put the middle bar of indicator head into the st

Download Pdf Manuals

image

Related Search

Related Contents

Débroussailleuses KDC-KDG 27 – 35 – 45  Operating Instructions  SoftBank 102SHII 取扱説明書  Exido Hair Styling Set 235-027 User's Manual  Samsung ST30 Керівництво користувача  C/IÜÔH Tab  1.17MB  

Copyright © All rights reserved.
Failed to retrieve file