QUIZ FOR NEW MRI USERS
Contents
1. Increase the number of signal averages 32 Which manual are you required to read before starting to use the MRI scanner A System Manual B Operation Manual C Application Manual D Advanced User Manual E Extra Manual 33 I would like to analyze SNR Signal to Noise after contrast injection in a brain tumor What kind of analysis tool can I use in PV 5 0 A Region of interest ROI B Image sequence analysis tool ISA C Diffusion tensor imaging DTI tool D Image J 34 I would like to fit a exponential decay to a set of images to obtain Tz relaxation time What kind of analysis tool can I use in PV 5 0 A Region of interest ROI B Image sequence analysis tool ISA C Diffusion tensor imaging DTI tool D Image J 35 What is the best way to transfer data to my computer A By asking Kai to make a copy of data for me B Using ssh file transfer protocol sftp C Using and external memory device such as a USB stick or external hard drive D By burning the data on a CD DVD storage media 36 Which equipment do I need to turn off disconnect when I am done scanning A Water circulation system in the electronics room B High power cabinet in the electronics room C Isoflurane on the anesthesia vaporizer D Anesthesia gas cables blue and white in both rooms MR room and animal preparation room E Disconnect the battery from the temperature module and connect it to the charging port on the respiration module 37 What do you n
2. change resolution settings through geometry editor run the new scan C Delete scan load the scan again from a protocol folder change resolution settings through geometry editor run the new scan D Clone reco change resolution settings through geometry editor run reco again 28 The reconstruction algorithm failed to produce the desired result What do you do A This cannot be done in Paravison so you need to export data to another post processing software B Delete scan collect data again C Clone reco run reco again D Delete reco run reco again 29 You would like to adjust the position of the imaging slice What do you do A Open Edit Scan tool and change geometry parameters using slice adjustment tool B Open Edit Scan tool and change contrast parameters C Open Geometry Editor tool and change geometry parameters using slice adjustment tool D Open Geometry Editor tool and change contrast parameters 30 You would like to change the contrast in the image What do you do A Open Edit Scan tool and change geometry parameters B Open Edit Scan tool and change contrast parameters C Open Geometry Editor tool and change geometry parameters D Open Geometry Editor tool and change contrast parameters 31 You would like to increase the SNR in your image What do you do A Decrease resolution in the image by increasing FOV field of view B Increase resolution in the image by decreasing FOV field of view C Increase slice thickness D
3. O gt MIC Molecular Imaging Center QUIZ FOR NEW MRI USERS MRI USER NAME DATE AND PLACE 1 CIRCLE ALL THAT APPLY Before you can use the MRI scanner for animal studies you have to A Have either been trained by MIC personal to use the scanner or have demonstrated competence in MRI B Have completed animal handling course and are certified FELASA category C Researchers in Laboratory Animal Science C Have no medical condition such as metallic implants pacemakers etc that would prohibit them from being in the high field environment D Have registered with and obtained a user account at MIC Molecular Imaging Center at UiB To book the time on the MRI scanner you have to A Email MIC administrators and ask them nicely to book the time slots for you B Ask your supervisor to book the time for you C Go to the MIC booking page and book the timeslots by yourself D Show up in the MRI room and start scanning if no one else is using the scanner Who has access to the MRI facility A All registered users B Cleaning personal from Vivarium C Technicians who help with the experiments with supervision from registered users D Haukeland employees What are you NOT allowed to bring into the MRI room A Food B Sick animals C Any metal object D Electronics cell phones and watches E Credit and access cards Which of the following objects has magnetic properties becomes magnetic when brought close to a high magnetic field
4. Stainless steal scissors Plastic tweezers Mouse ear clippers A screwdriver Animal monitoring equipment moowD 10 11 12 13 14 Which of the following IS NOT part of an MRI system A RF resonators coils B Gradient coils C Shim coils D Animal monitoring equipment E Computer controlling the scanner Which equipment do you need to turn on EVERY time you want to scan animals A Main power switch in the electronics room B Animal monitoring equipment C The main magnetic field D Water heater and circulation system E Chiller in the electronics room You arrive one day to the MRI room and all the equipment is dead and will not turn on You have to A Call either Kai or Tina immediately B Panic C Press the red button in the MR control room D Press the green button in the MR control room What are the RF resonators used for A For keeping the animal constrained during a scan B For creating a gradient field which encodes for the spatial coordinates C For MR signal transmission and reception D For magnetizing water protons Which RF resonator would you use for imaging rat head tumors A 23 mm resonator B 38mm resonator C 60mm resonator D 100 mm resonator What is the animal bed used for A Attaching the animal onto the anesthesia mask B Securing and preparing the animal for scanning C Keeping the animal warm during the scan D Sliding the animal into the magnet center How do you monitor respiration of t
5. eed to record in the MR log book Date and time of scanning Project title Level of liquid He and liquid Nz at the end of scanning Your name Your supervisor s name moon gt
6. he animal during the scan A With a pressure sensor pillow B With a thermocouple C With ECG electrodes D With Paravision software How do you keep the animal warm during the scan A By wrapping it up in lots of paper towels B By using a blanket with hot recirculation water C By using high power RF pulses during the scan D By blowing hot air onto the animal How do you administer anesthesia to the animal during an MRI scan A By injecting phentobarbital subcutaneously B By applying sevoflurane gas mixed with oxygen and N20 through a nose mask C By applying isoflurane gas mixed with oxygen and N20 through a nose mask D Anesthesia is not necessary during MRI scan 15 16 17 18 19 20 21 22 23 Before you can get an account on the MRI system you have to A Bearegistered MIC user B Have either completed the MRI course or demonstrated competence in MRI C Have completed animal handling course and are certified FELASA category C Researchers in Laboratory Animal Science D Contact Kai or Tina What is the name of the program that controls the scanner A Topspin 2 0 B Paravision 3 0 C Propervision 5 0 D Paravision 5 0 What is a TriPilot A A pilot study which has been performed three times B A fast scan that collects three equivalent images one after another C A pulse sequence which performs initial calibration of the scanner D A fast scan that collects three slices in the iso center of the magnet
7. see an image on the screen but not of the part of the body I am interested in What should I do A Using the RULER tool in the Image Display and Processing window measure the distance by which you have to move the animal into out of the scanner and then move it the corresponding amount B Move animal in out of the scanner by 1 cm perform a Tri Pilot check the position and repeat until you have the region of interest in the middle of the Field of View C Move the Field of View in the geometry editor so that the region of interest is in the middle of the Filed of View D Switch to a different RF coil 25 What are scan protocols A Aset of rules written by MIC which you need to follow when scanning B A set of rules written by Bruker which you need to follow when scanning C Acollection of pulse sequences D Acombination of a measuring method combined with a set of suitable parameter values to achieve special experimental purposes 26 If you want to create a new scan with exactly the same acquisition parameter as the previous scan you need to A Save the collected scan in a protocol folder and then load it when creating a new scan B Clone scan C Clone reco D This cannot be done 27 You collected an image but see that you should have had better image resolution Which of the following is the best solution to this problem A Undo scan change resolution settings through geometry editor run scan again B Clone scan
8. to facilitate slice positioning using geometry editor What adjustments calibrations are being performed before the first scan of the study A Resonant frequency adjustment B Preemphasis adjustment C Shimming D Transmitter gain adjustment E Receiver gain adjustment How do you force the adjustments to perform when you want to A Press TRAFFIC LIGHT B Press SHIFT TRAFFIC LIGHT C Press GOP D Press GPS When do you need to force these adjustments calibrations A After you create a scan B After you create a new study C After you create a new patient D Whenever you reposition the animal How is the transmitter gain adjustment performed A By computing the gain needed for achieving a 90 pulse B By computing the gain needed for achieving a 180 pulse C By computing the gain needed for achieving a 90 and 180 pulses D By computing the gain needed for maximum flip angle E By computing the gain needed for minimum flip angle What if I get no signal image after running the Tri Pilot A Check that the animal is in the right position within the magnet B Check that you have connected the coil to the preamplifier at the back of the scanner C Turn off and then back on the main power on the spectrometer D Restart the computer E Call Tina Kai or Frits for help Which PV window do use for viewing finished scans Macro manager Data manager Image display and processing tool Scan control tool Acq Rec Display mooOw gt 24 I