Home
Model Ei206D BATTERY POWERED CARBON
Contents
1. 16204 0 2060 0 20 6 08 3 49 Page 1 BATTERY POWERED CARBON MONOXIDE ALARM y Electronics WITH DIGITAL DISPLAY 9 Model Ei206D Read and retain carefully for as long as the product is being used It contains vital information on the operation and installation The leaflet should be regarded as part of the product If you are just installing the unit the leaflet must be given to the householder The leaflet is to be given to any subsequent user B16204 RO 206D UC ENG 20 6 08 3 49 PM Page 2 CONTENTS Page 1 READ THIS FIRST 1 2 CARBON MONOXIDE THE SILENT KILLER 3 WHERE PLACE CARBON MONOXIDE ALARMS 8 4 INSTALLING YOUR CARBON MONOXIDE ALARMS 13 5 TESTING amp MAINTAINING YOUR CARBON MONOXIDE ALARMS 16 6 MAINTAINING CARBON MONOXIDE ALARMS 18 7 LIMITATIONS OF CARBON MONOXIDE ALARMS 20 8 lt gt HOWTO PROTECT YOUR FAMILY 21 9 TECHNICAL SPECIFICATIONS 23 10 GETTING YOUR CARBON MONOXIDE ALARMS SERVICED 23 11 GUARANTEE 25 12 TROUBLESHOOTING 26 16204 0 2060 0 20 6 08 3 49 Page 3 1 READ THIS FIRST Install the Carbon Monoxide Alarm CO Alarm in every room that contains a fuel burning appliance particularly rooms where people spend a lot of time e g bedrooms kitchens and sitting rooms NN In rooms with an appliance install preferably on the ceiling 300mm from walls and between 1m to 3m horizontally from appliance In rooms r
2. These appliances must breathe in air to burn the fuel properly Know where the air comes from and ensure vents air bricks etc remain unobstructed particularly after building work The appliances must also breathe the waste gases including the CO usually through a flue or chimney Ensure chimneys and flues are not blocked or leaking and get them checked every year Check for excessive rust or cracks on appliances and pipe work Never leave your car motor bike or lawnmower engine running in the garage with the garage door closed Never leave the door from the house to the garage open if the car is running Never adjust your own gas pilot lights Never use a gas cooker or a barbecue for home heating Children should be warned of the dangers of CO poisoning and instructed never to touch or interfere with the CO Alarm Do not allow small children to press the test hush button as they could be subjected to excessive noise when the unit alarms 21 16204 0 2060 0 20 6 08 3 49 Page 24 9 Leaving windows doors slightly open even a few inches will significantly reduce the risk of high levels of CO occurring The high levels of draught proofing in modern houses reduces ventilation and can allow dangerous gases to build up 10 Install CO Alarms in all the areas recommended in this leaflet 11 Recognise that CO poisoning may be the cause when family members suffer from flu like
3. symptoms when at home but feel better when they are away for extended periods 9 TECHNICAL SPECIFICATION Power QV Alkaline battery supplied CO Sensitivity Meets BS EN 50291 2001 Unit operates as per Table B on page 6 Electromagnetic Complies with BS EN 50270 Compatibility Test Hush Button Checks electronics and horn When the unit is alarming after sensing CO pressing the test hush button will immediately stop the horn the red light will continue to flash If CO is still present the red light and the horn will turn on again after about 4 minutes The unit can only be silenced once during a CO incident At 300 ppm CO the unit cannot be silenced With interconnected units the hush only works on the alarm sensing CO Testing with CO The red light flashes as Table within 10 seconds of unit detecting CO and the display shows the CO concentration in ppm CO Initialisation Time 70 seconds On power up green red and amber lights flash momentarily to show they are operational The red light may flash intermitently during this 70 seconds 22 16204 0 2060 0 20 6 08 3 49 Page 25 Operating Temperature Humidity Range Audible Alarm Self Diagnostics Tamperproof CO Alarm Memory Digital Display Sensor Replacement 10 C to 40 C 15 to 95 R H non condensing 85dB A at 3m minimum Horn beep and amber fault light flashes every 40 seconds if a sensor fault
4. wood petrol diesel charcoal etc CO is absorbed by red blood cells in the lungs in preference to oxygen this results in rapid damage to the heart and brain from oxygen starvation High levels of CO in a house can be caused by Incorrectly or poorly installed fuel burning appliances e Blocked or cracked chimneys flues e Blocked vents or draught proofing which makes areas with fuel burning appliances or fireplaces airtight Engines of cars lawnmowers etc left running in confined spaces Portable paraffin or gas heaters in badly ventilated rooms 2 2 Symptoms of Carbon Monoxide Poisoning Most people know that high levels of CO are harmful however the period of exposure is also important The following symptoms are related to Carbon Monoxide poisoning and should be discussed with all members of the household Mild Exposure Slight headache nausea vomiting fatigue often described as flu like symptoms Medium Exposure Severe throbbing headache drowsiness confusion fast heart rate Extreme Exposure Unconsciousness convulsions cardiorespiratory failure death 4 B16204 R0 206D UC ENG 20 6 08 3 49 Page 7 high level of CO for a short period e g 350 ppm for 30 minutes will cause the same symptoms a slight headache as a lower level for a longer time e g 150 ppm for 90 minutes Table A shows how exposure to different concentrations of CO generally affects people Many cases of
5. 2060 0 20 6 08 3 49 Page 16 Figure 6 Connect the battery to battery snaps Figure 5 Removing the CO Alarm from the mounting plate REPLACEABLE SENSOR MODULE SENSOR MODULE Ei261MEN MOUNTING PLATE Sey BASE SNAPS OF UNIT gt 5 a gt 14 16204 0 2060 0 20 6 08 3 49 Page 17 Figure 7 Mounting the Unit Figure 8 Tamperproofing the Unit LOCATION FOR TAMPERPROOF SCREW RECOMMENDED see page 13 SCREW HOLES MOUNTING PLATE 5 TESTING amp MONITORING YOUR CO ALARM Button Test It is recommended that you test your CO Alarm after installation and then once a week to make sure the unit is working It will also help you and your family to become familiar with the sound of the alarm Press and hold the test button until the alarm sounds it may take up to 5 seconds The alarm will stop sounding shortly after the button is released If there is a problem follow the checklist below The red light will flash if it has detected CO and been in alarm memory since CO was recorded The display will show the highest reading since memory was reset 15 B16204 R0 206D UC ENG 20 6 08 3 49 Page 18 Power Indicator Regularly check that the green power light flashes every 45 seconds the unit cannot work without a good battery properly connected Low Battery Indicator If the unit beeps every 45 seconds and is on the
6. display then the battery is depleted Remove from the mounting plate see figures 5 amp 6 Replace the battery Use only the following 9V Alkaline batteries Duracell MN1604 or Energizer 9V See page 13 if the tamperproof screw has been fitted Attach the new battery to the battery snaps firmly with the correct orientation Button test the alarm to check the battery is installed correctly and that it is not depleted The battery will usually last over 1 year in standby under normal conditions An undepleted battery can power a unit in alarm for over 10 hours The life will be reduced if the unit regularly goes into alarm or if it is exposed to excessive temperatures for long periods Amber Fault Indicator If the unit beeps and the amber light flashes simultaneously every 45 seconds and SF is on the display the self checking circuitry may have detected a fault Follow the checklist to confirm that the unit is actually defective Checklist in the event of problems 1 Remove from mounting plate and check that the battery is connected and firmly snapped on to the connectors 2 Disconnect the battery for 1 minute and re connect this resets the unit 3 If the problem persists replace the battery If none of the above solve the problem the unit is probably defective and must be replaced See Getting the CO Alarm Serviced Page 24 16 16204 0 2060 0 20 6 08 3 49 Page 19 Testing with Carbon M
7. is found Locking screw is supplied A unit will indicate if it has been in alarm previously by flashing the red light for 2 seconds every 40 seconds 2 flashes for 50 ppm CO 4 flashes for 100 ppm CO and 8 flashes for 300 ppm CO When the test button is pressed the red light flashes as per table B and also indicates the previous CO alarm level detected The memory is cleared by holding down the test button until the red light stops flashing takes approx 20 seconds When the test button is pressed the display shows the highest CO level detected since it was reset Range 30 300ppm Resolution 5 ppm CO With a depleted battery CP With sensor faulty SF With Test Hush button pressed shows previous peak CO level The memory is cleared by holding down the test button until the display reads 000 takes approx 20 seconds Amber light flashes every 45 seconds after being installed for 6 years to show the sensor must be replaced also see sensor replacement date on sidewall label Note The sensor can only be replaced once 23 16204 0 2060 0 20 6 08 3 49 Page 26 End of Life Indication Amber light flashes every 45 seconds after 11 years to show the unit must be replaced Dimensions 126 x 150 x 42 mm Weight 280g 10 GETTING THE CO ALARM SERVICED If your CO Alarm fails to work after you have carefully read all the instructions checked the unit has been installed cor
8. loud alarm if the CO persists The digital display indicates the CO level in parts per million ppm CO Table B below shows how the CO Alarm reacts to different levels of CO gas and exposure time At higher levels of CO the alarm turns on sooner The rate of flashing of the red light indicates the level of CO Table B CO Alarm Response Horn On Digital Alarm Light ithi Display a 1 Flash 2 Seconds 60 to 90 minutes CO level 100 2 Flashes Second 10 to 40 minutes in ppm CO unless it has been in alarm see CO Alarm Memory below If your CO Alarm sounds follow the instructions on page 2 When ventilation is provided by leaving the window and doors open the CO build up may have dissipated by the time help arrives and the alarm may have stopped sounding Although your problem may appear temporarily solved it is crucial that the source of the CO is determined and appropriate repairs made NEVER IGNORE THE ALARM 6 16204 0 2060 0 20 6 08 3 49 Page 9 Pre Alarm The digital display shows Carbon Monoxide levels above 30 parts per million 30ppm This helps locate CO leaks as the unit gives an indication straight away When the alarm detects over 50ppm CO the red light flashes every 2 seconds Note the Pre Alarm signal may be triggered by CO coming for example from cooking with gas from car engines or from nearby barbecues This is usually not a concern unless the Pre Ala
9. reported Carbon Monoxide poisoning indicate that while victims are aware they are not well they become so disorientated they are unable to save themselves by either leaving the building or calling for assistance Young children and household pets may be the first affected Table A Effects of Carbon Monoxide Poisoning Concentration of CO in Air Inhalation Time approx and Symptoms Developed ppm4 The maximum allowable concentration for continuous exposure any 8 hour period according to OSHA Slight headache after 1 5 hours Slight headache fatigue dizziness nausea after 2 3 hours Frontal headaches within 1 2 hours life threatening after 3 hours also maximum parts per million in flue gas on an air free basis according to US Environmental Protection Agency Dizziness nausea and convulsions within 45 minutes Unconsciousness within 2 hours Death within 2 3 hours Headache dizziness and nausea within 20 minutes Death within 1 hour Headache dizziness and nausea within 5 10 minutes Death within 25 30 minutes Headache dizziness and nausea within 1 2 minutes Death within 10 15 minutes Death within 1 3 minutes parts per million OSHA Occupational Safety amp Health Association 16204 0 2060 0 20 6 08 3 49 Page 8 2 3 What happens when your CO Alarm detects Carbon Monoxide When the Alarm detects potentally dangerous levels of CO it flashes the red alarm light and then sounds a
10. seconds 2 Check the battery is correctly connected 3 Replace battery ALARM BEEPS EVERY 45 SECONDS If the Alarm beeps every 45 seconds and disply shows CP then the battery must be replaced If the Alarm beeps every 45 seconds and amber light flashes at the same time and SF is on display then the unit is probably defective Disconnect the battery press the test button for 1 minute to reset the unit Re connect the battery and re check If problem persists replace the unit ALARM SOUNDS FOR NO APPARENT REASON Follow the detailed instructions entitled What to do when the alarm sounds page 2 If there is still problems 1 Ensure there are no fuel burning appliances in the vicinity which could be leaking CO gas e g even from next door 2 Ensure there are no fumes in the area e g paint thinners hair spray chemical cleaners aerosol sprays etc 3 Ensure there is no outdoor source of CO in the vicinity e g a car with engine running heavy traffic heavy air pollution barbecue fumes etc 25 16204 0 2060 0 20 6 08 3 49 Page 28 4 Press the test hush button to silence the alarm If the unit continues to sound it is possibly defective and should be replaced see section 11 Getting the CO Alarm Serviced ALL LIGHTS FLASH On power up the green red and amber lights turn on in sequence to show they are working THIS IS NORMAL AMBER LIGHT FLASHING e
11. warning of fire The CO Alarm does not detect the presence of natural gas methane bottled gas propane butane or other combustible gases Fit combustion gas alarms to detect these WARNING THIS CO ALARM IS DESIGNED TO PROTECT INDIVIDUALS FROM THE ACUTE EFFECTS OF CARBON MONOXIDE EXPOSURE IT WILL NOT FULLY SAFEGUARD INDIVIDUALS WITH SPECIFIC MEDICAL CONDITIONS IF INDOUBT CONSULT A MEDICAL PRACTITIONER 8 HOW TO PROTECT YOUR FAMILY Follow these guidelines to reduce the risk of Carbon Monoxide poisoning 1 Know and look out for tell tale signs that Carbon Monoxide may be present These include The CO Alarm warning of abnormal levels 20 16204 0 2060 0 20 6 08 3 49 Page 23 2 3 4 5 6 7 8 Staining sooting or discolouration on around appliances A pilot light frequently going out A strange smell when an appliance is working Anaked gas flame which is yellow or orange instead of the normal blue Family members including pets exhibiting the flu like symptoms of CO poisoning described above If any of these signs are present get the appliance checked out by an expert before further use If family members are ill get medical help Choose all appliances and vehicles which burn fossil fuels such as coal oil natural bottled gas paraffin wood petrol diesel charcoal etc with care and have them professionally installed and regularly maintained
12. 3 49 PM Page 21 The crossed out wheelie bin symbol that is on your product indicates that this product should not be disposed of via the normal household waste stream Proper disposal will prevent possible harm to the environment or to human health When disposing of this product please separate it from other waste streams to ensure that it can be recycled in an environmentally sound manner For more details on collection and proper disposal please contact your local government office or the retailer where you purchased this product 7 LIMITATIONS OF CO ALARMS 1 The CO Alarm will not work without a good battery the green power light must flash every 45 seconds If the battery has been drained the alarm will not give protection Button test the alarm on return from holidays and other long absences 2 Carbon Monoxide must enter the unit for it to be detected There may be Carbon Monoxide in other areas of the house e g downstairs in a closed room etc but not in the vicinity of the CO Alarm Doors air draughts and obstructions can prevent the CO reaching the Alarm For these reasons we recommend CO Alarms are fitted both near and in bedrooms particularly if bedroom doors are closed at night Additionally install in rooms where members of the household spend much of their time and in rooms with potential sources of CO gas 3 The CO Alarm may not be heard The sound output is loud but it may not be heard behind a cl
13. Figure 2 Location in room with a fuel burning appliance 16204 0 2060 0 20 6 08 3 49 Page 14 Figure 3 Location in rooms with sloped Figure 4 Location in bedroom amp rooms remote ceilings the CO alarm should be located from the appliance at the high side of the room i e at breathing level 12 16204 0 2060 0 20 6 08 3 49 Page 15 4 INSTALLING YOUR CARBON MONOXIDE ALARM INSTALLATION PROCEDURE 1 2 Select a suitable location based on the above advice Remove the CO Alarm from the mounting plate as shown in figure 5 by holding the plate and sliding the unit in the direction shown Connect the battery firmly to the battery snaps see figure 6 The green red and amber lights will flash in sequence Note the red light may also flash intermittently for the first 70 seconds this is normal Carefully align the mounting plate to the wall or ceiling selected Mark the position of the two mounting holes using the mounting plate as a template Drill two holes with a 5mm drill for the plastic plugs supplied See figure 7 Caution Ensure there is no wiring where the screws are being installed Slide CO Alarm on to the mounting plate Note The unit may be tamper proofed further by removing the knockout on the sidewall of the mounting plate as shown in figure 8 and inserting the self tapping screw 3mm diameter 12mm long after the unit is on the mounting plate 16204 0
14. emote from the appliance install at breath level where the light indicators can be seen IN Test the unit weekly by pressing the test hush button the horn will sound Replace the battery yearly or when the unit beeps every 40 seconds or when CP is on the display Replace sensor module after 5 years operation see page 18 N N N 16204 0 2060 0 20 6 08 3 49 Page 4 What to do when alarm sounds 1 Open the doors and windows to ventilate the area 2 Turn off all fuel appliances where possible and stop using them The alarm can be silenced immediately by pushing the test hush button 3 Evacuate the property leaving the doors and windows open 4 Get medical help immediately for anyone suffering the effects of Carbon Monoxide poisoning headache nausea and advise that Carbon Monoxide poisoning is suspected 5 Ring your gas or other fuel supplier on their emergency number Keep the number in a prominent place 6 Do not re enter the property until the alarm has stopped If the alarm has been silenced by pressing the test hush button wait at least 5 minutes so the alarm can check that the CO has cleared 7 Do not use the fuel appliances again until they have been checked by an expert In the case of gas appliances in the UK this must be a CORGI registered installer When the CO Alarm detects abnormal levels of CO above 50ppm CO the red light starts to flash and the horn will
15. m Warning Do not open or tamper with the CO Alarm There are no user serviceable parts inside This can damage the unit 17 16204 0 2060 0 20 6 08 3 49 Page 20 SENSOR MODULE REPLACEMENT Replace the sensor module after 5 years operation or by the date on the REPLACE SENSOR BY label on the side of the unit After 5 years operation the amber light will flash once every 40 seconds without a beep to indicate the sensor should be replaced 1 Remove the alarm from the mounting plate as described previously 2 Pull out the sensor module from the rear see figure 6 3 Replace with a new sensor module Model No Ei261MEN Contact Ei Electronics for your nearest module supplier 4 Carefully align the module including the connector pins and push firmly home 5 Remove the REPLACE SENSOR BY label on the side of the alarm 6 7 Wait 4 minutes for the new sensor to stabilise and then press the Test Hush button the horn should sound Slide the alarm back on to the mounting plate oe Note When the second sensor has completed its 5 years of operation the amber light will flash every 40 seconds The sensor module can only be replaced once The entire unit must then be replaced after 10 years The date for replacing the entire unit is given on the REPLACE UNIT BY label on the alarm 18 16204 0 2060 0 20 6 08
16. of time Every bedroom However if the number of Carbon Monoxide Alarms is limited the following points should be considered when deciding where best to fit the alarm s If there is an appliance in a room where people sleep place a CO Alarm in this room and Locate a CO alarm in a room containing a flueless or open flued appliance and Locate an alarm in a room where the occupant s spend most of their time e g sitting room and In a bedsit the CO alarm should be placed as far away from the cooking appliance as possible but near to where the person sleeps and the appliance is in a room not normally used such as a boiler room the CO alarm should be placed just outside the room so that the alarm will be heard more easily 3 2 Unsuitable Locations Do not place the CO Alarm in any of the following areas 8 B16204 RO0 206D UC ENG 20 6 08 3 49 PM Page 11 12 13 3 3 In the immediate vicinity of a cooking appliance keep it at least 1 metre horizontally from it Outside the building In an enclosed space e g in or below a cupboard In a damp or humid area Directly above a sink or cooker Next to a door window air vent or anywhere that it would be affected by draughts Next to an extractor fan Where it would be obstructed e g by curtains or furniture In an area where the temperature could drop below 10 C or rise above 40 C Where dirt or dust could block the sensor Where it co
17. onoxide The unit can be tested with CO by using one of the kits that comes with CO either in a glass phial or aerosol can Follow the instructions on the kit It is best if possible to inject the CO gas into the gas entry holes see Figure 1 When it senses the CO it flashes the red light as per Table and the display shows the level in ppm of CO to confirm that is detecting CO gas How to distinguish between CO Alarm and Smoke Alarm warnings The CO Alarm has a distinctive on off sound of 3 pulses followed by a pause as compared with a typical Smoke Alarm which has a rapid pulsing sound In addition when your CO Alarm detects CO the red light will be flashing Testing both your CO Alarm and Smoke Alarms weekly will help you and your family to clearly distinguish between them in an emergency 6 MAINTAINING YOUR CARBON MONOXIDE ALARM Clean the outside case by occasionally wiping with a clean damp cloth Do not use any cleaning agents bleaches detergents or polishes including those in aerosol cans Avoid spraying air fresheners hair spray paint or other aerosols near the CO Alarm Do not place air fresheners near the unit Use the narrow nozzle of a vacuum cleaner to remove fluff and other contamination from the cover slots to ensure CO gas can reach the sensor see Gas Sensor positioning shown in figure 1 Caution Do not paint the CO Alarm Remove the CO Alarm when decorating Do not allow water or dust to contaminate the alar
18. osed door or if it is too far away Interconnecting CO Alarms greatly improves the probability that they will be heard the Ei206D cannot be interconnected purchase suitable models if this feature is required The 19 16204 0 2060 0 20 6 08 3 49 Page 22 Alarm may wake up somebody who has taken alcohol or drugs The alarm sound may masked other sounds such as T V stereo traffic noise etc Fitting CO Alarms on either side of closed doors will improve their chance of being heard This CO Alarm is not designed for people with impaired hearing 4 CO Alarms don t last indefinitely CO Alarms are sophisticated electronic devices with many parts Although the alarm and its component parts have undergone stringent tests and are designed to be very reliable it is possible that parts can fail Therefore you should test your CO Alarm weekly The CO Sensor must be replaced after 5 years operation and the entire unit after 10 years 5 CO Alarms are not a substitute for life insurance House holders are responsible for their own insurance The CO Alarm warns of increasing CO levels but we do not guarantee that this will protect everyone from CO poisoning 6 CO Alarms are not suitable as early warning Fire Alarms Some fires produce Carbon Monoxide but the response characteristics of these CO Alarms are such that they would not give sufficient warning of fire Smoke Alarms must be fitted to give early
19. rectly and ensured that it has a good battery connected return it for repair or replacement This should be where it was purchased or alternatively return it in a padded box to Customer Assistance and Information at the nearest address given on the CO Alarm or in this leaflet If the unit is beeping then remove the battery as shown in figures 5 amp 6 State the nature of the fault where the CO Alarm was purchased and the date of purchase p 11 GUARANTEE Ei Electronics guarantees the Ei206D Carbon Monoxide excluding the battery for two years from date of purchase against any defects that are due to faulty materials or workmanship This guarantee only applies to normal conditions of use and service and does not include damage resulting from accident neglect misuse unauthorised dismantling or contamination howsoever caused This guarantee excludes incidental and consequential damage If the Carbon Monoxide Alarm should become defective within the guarantee period it must be returned to where it was purchased or alternatively to Ei Electronics carefully packaged with the problem clearly stated see section 11 Getting the CO Alarm Serviced along with proof of the date of purchase We shall at our discretion repair or replace the faulty unit 24 16204 0 2060 0 20 6 08 3 49 Page 27 12 TROUBLESHOOTING ALARM DOES WORK WITH THE TEST BUTTON 1 Hold button down firmly for at least 5
20. rm signal persists until the alarm sounds and the CO source is unknown NOTE The CO Alarm may sound if cigarette smoke is blown into it or aerosols are released nearby CO ALARM MEMORY When the test button is held the display shows the previous peak reading This tells you if the unit has detected CO in your absence and helps to detect and locate leaks monitor premises etc Also when the test button is pressed the horn will sound and the red light will only flash if the unit has previously detected CO and been in alarm The flash rate indicates the level of CO detected as below Red light is Off No CO detected since reset or power up Red light flashes 2 times in 4 seconds every 40 seconds 50 ppm CO detected for about 90 minutes since reset or power up Red light flashes 8 times in 4 seconds every 40 seconds 100 ppm CO detected for about 40 minutes since reset or power up Red light flashes 16 times in 4 seconds every 40 seconds 300 ppm CO detected for about 3 minutes Reset Memory by holding down the test button for over 20 seconds until the red light stops flashing and display shows 000 Cover the horn with a cloth to muffle the alarm during this time 16204 0 2060 0 20 6 08 3 49 PM Page 10 3 WHERE PLACE ALARMS 3 1 Ideally a Carbon Monoxide Alarm should be installed in Every room containing a fuel burning appliance and Remote rooms where occupants spend a considerable amount
21. sound within 90 minutes At higher levels of CO the alarm will turn on sooner see table B page 6 The display shows levels above 30ppm CO 2 16204 0 2060 0 20 6 08 3 49 Page 5 The CO Alarm will automatically reset Figure 1 Alarm Installation once the CO has cleared Pressing the test hush button resets the CO Alarm immediately below 300ppm CO If CO GAS ENTRY HOLES is still present the red light and horn will turn on again after about 4 minutes The CO Alarm is substitute for keeping chimneys and flues clear and in good condition and having all of your appliances serviced regularly according to the manufacturer s instructions Do not fit alarm until all building work is completed to avoid contamination MOUNTING PLATE 2 CARBON MONOXIDE THE SILENT KILLER 2 1 What is Carbon Monoxide Congratulations on becoming the owner of an Ei Carbon Monoxide Alarm This will help protect you and your household from the dangerous effects of Carbon Monoxide the silent killer CO is the chemical symbol indicating the molecule has one carbon atom and one oxygen atom B16204 RO 206D UC ENG 20 6 08 3 49 PM Page 6 Many are killed each year and many more suffer ill health from Carbon Monoxide CO poisoning is an invisible odourless tasteless and extremely toxic gas It is produced by appliances and vehicles burning fuels such as coal oil natural bottled gas paraffin
22. uld be easily knocked or damaged or where it could be accidentally turned off or removed In a bathroom or other areas where the CO alarm may be exposed to water splashes dripping or condensation e g above an electric kettle Near paint thinners solvent fumes or air fresheners If locating the CO alarm in a room with a fuel burning appliance see figure 2 If it is mounted on a wall it should be located at a height greater than the height of any door or window but still be at least 150mm from the ceiling 9 16204 0 2060 0 20 6 08 3 49 Page 12 If it is mounted the ceiling it should be at least 300mm from any wall or light fitting e The CO alarm should be a horizontal distance of between 1m and 3m from the potential CO source If there is a partition the room the CO alarm should be located on the same side of the partition as the potential source In rooms with sloped ceilings the CO alarm should be located at the high side of the room see fig 3 3 4 If locating the CO alarm in a bedroom or in rooms remote from a fuel burning appliance see figure 4 Mount the CO alarm relatively close to the breathing zone of the occupants Whatever position is chosen make sure it is possible to view the three light indicators when in the vicinity of the alarm 16204 0 2060 0 20 6 08 3 49 Page 13 CO Alarm DEAD AIR DON T LOCATE
23. very 45 seconds If the unit has been operating for 6 years the sensor must be replaced If the sensor has already been replaced and the amber light is flashing replace the entire unit see the replace unit by date sidewall Ei Electronics Shannon Co Clare Ireland Tel 061 471277 Fax 061 471053 E mail helpdesk eiltd ie www eielectronics com Aico Ltd Mile End Business Park Maesbury Rd Oswestry Shropshire SY10 8NN U K Tel 0870 7584000 Fax 0870 7584010 E mail support aico co uk www aico co uk Ei Electronics 2007 P N B16204 Rev 0 26
Download Pdf Manuals
Related Search
Related Contents
Samsung Machine à laver VISTULA avec technologie Eco Bubble, 8 kg Manuel de l'utilisateur AMI-G3 System User Manual V1.0 Model RW8M22 OWNER`S MANUAL Xit XTCG5DIII Zebra LP 2824 Copyright © All rights reserved.
Failed to retrieve file