Home

Operating Instructions

image

Contents

1. AIRFLOW N Domestic AC Fans 230V Installation and Operating Guide IC ICAN eco 230V AC Base Models iCON eco15 72683501 iCON15 72591501 iICON30 72591601 iCON60 72591701 Fan Manufactui rers 3 Association Certificate No EMS 569454 Certificate No FM 00152 BS EN ISO 14001 2004 BS EN ISO 9001 2008 AIRFLOW 4 ICON Domestic Fan 230V Installation Maintenance and Use iCON Domestic Fans are available in 3 model sizes and can be fitted to a wall or ceiling Each fan requires a suitable size hole through the wall or ceiling which connects into a duct venting to the outside The external opening should be covered by a suitable external grill available separately from Airflow Developments Ltd Airflow iCON iCON eco Model Options 72683501 eco15 100mm Axial Fan with maximum capacity of 18 6 l sec 72573602 15 100mm Axial Fan with maximum capacity of 21 l sec 72591601 30 100mm Mixed Flow Fan with maximum capacity of 32 sec 72591701 60 150mm Mixed Flow Fan with maximum capacity of 72 sec The iCON range can be used as a simple extract fan operated by a remote switch or can be fitted with an internal control module available separately to give a range of control options including timer humidity motion sensor pull cord trickle speed or combinations of these functions Optional modules are available separately and can be fitted at the time of installation or retr
2. HP12 3QP Czech Republic Tel 49 0 222 69205 0 United Kingdom Fax 49 0 222 69205 11 Tel 42 0 2 7477 2230 Email info airflow de Tel 44 0 1494 525252 Fax 42 0 2 7477 2370 Web _ airflow de Fax 44 0 1494 461073 Email info airflow cz Email info airflow com Web airflow cz Web airflow com AIRFLOW DEVELOPMENTS Limited reserve the right in the interest of continuous development to alter any or all specifications without prior notice Page 8 of 8
3. joists Fans should not be fitted to unsupported plaster board Page 4 of 8 AIRFLOW 4 The iCON 15 and iCON eco15 requires a 110mm diameter hole through the ceiling The fan should be fixed with the screws provided through the plaster board into the support The iCON30 will require a 160mm diameter hole and the iCON60 a 190mm hole Surface Mounting Fans on the Ceiling POSSIBLE CABLE ROUTING MOUNTING SKIRT PLYWOOD When surface mounting the iCON30 the mounting skirt should be used The iCON30 requires a 110mm diameter hole through the ceiling and the iCON60 a 170mm diameter hole The surface mounted skirt to be fixed with the screws provided through the plaster board into the support The fan is then fitted into the skirt Where flexible duct is used the diameter must be maintained Flexible ducting supports Maximum length of ee f aA 3 Re flexible ducting Pra WN f N i nim SS the diameter of flexible ducting used q _ Room terminal extract grille t Airflow Sealant Page 50f8 AIRFLOW Electrical Installation All electrical installation to be carried out by an approved electrician in accordance with Part P U K Building Regulations and to the latest IEEE standards or the appropriate regulations in the country of installation iCON Domestic Fans require a 230V 50Hz supply it is double insulated so therefore does not require an earth For fans mo
4. from or in connection with the equipment excepting only that nothing in this condition shall be construed as to exclude or restrict liability for negligence ad This warranty does not in any way affect any statutory or other consumer rights Page 7 of 8 9041548 AIRFLOW ve 01 12 Range of Optional Modules Available Choose the 230V Module PCM Pull Cord 72573602 B TM Adjustable Timer 72612601 B HTM Humidity Pull cord with Timer Overrun 72573902 B PRTM Passive Infra Red with Timer Overrun 72573903 B PRHTM Passive Infra Red Humidity Timer 72573901 B CVM30 Continuous Ventilation iCON30 72631802 CV2 Continuous Ventilation 72675701B _ DTM Delayed Timer start AC 7265702B f 2SHM 2 Speed Humidity Pull Cord boost AC 72675703B ee alll Anthracite Sandstone ICON 15 cover Anthracite 52634503B ICON 30 cover Silver 52634507B ICON 15 cover Silver 52634504B ICON 30 cover Sandstone 52634508B ICON 15 cover Sandstone 52634505B ICON 60 cover Anthracite 52634509B ICON 15 cover Chrome 52634502B ICON 60 cover Silver 52634510B ICON 30 cover Anthracite 52634506B ICON 60 cover Sandstone 52634511B UK Head Office Czech Republic Germany AIRFLOW DEVELOPMENTS Limited AIRFLOW LUFTTECHNIK GmbH AIRFLOW LUFTTECHNIK GmbH Aidelle House Lancaster Road o s Praha Postfach 1208 Cressex Business Park Hostynska 520 D 53349 Rheinbach High Wycombe 108 00 Praha 10 Germany Buckinghamshire Malesice
5. irflow recommend that rigid ducting is used instead of flexible ducting this will ensure maximum performance Front Cover Removal The front cover fan has a bayonet type fitting To remove undo the retaining screw at the bottom edge of the cover using a screwdriver then rotate the cover a few degrees anticlockwise and remove To refit reverse the above UNDO THE RETAINING procedure SCREW AT THE BOTTOM EDGE OF COVER USING A SCREWDRIVER Page 3 of 8 AIRFLOW 4 Recessing Fans in the Wall The iCON 15 and iCON eco15 requires a 110mm diameter hole through the wall lined with a 100mm id internal diameter duct The iCON30 requires a 110mm diameter hole through the wall counter bored 160mm to a depth of 75mm The 110mm hole should be lined with a 100mm id duct The iCON60 requires a 160mm diameter hole through the wall counter bored 190mm to a depth of 75mm The hole should be lined with 150mm id duct Surface Mounting Fans on the Wall When surface mounting the iCON30 and iCON60 the supplied mounting skirt should be used The iCON30 requires a 110mm diameter hole through the wall lined with a 100 mm id duct and the iCON60 requires a 160mm diameter hole through the wall lined with a 150 mm id duct Recessing Fans in the Ceiling POSSIBLE CABLE ROUTING Ye cai ee CEILING PLYWOOD When recessing fans in the ceiling a plywood support min 18mm thick should be mounted between the ceiling
6. n result in restricting the free rotation of the impeller and a thermal overload of the motor could occur causing short term fan failure In the event of this occurring loosen the duct connection so that the impeller rotates freely within the spigot The motor is fitted with an automatic reset after approximately 15 minutes and will restart the fan when reconnected to the module controller and mains supply Warranty Applicable to units installed and used in the United Kingdom Airflow guarantees the iCON iCON eco fan units and iCON modules for 2 YEARS from date of purchase against faulty material or workmanship Extended to 3 when registered airflow com Warranty only covers the fan not the reinstallation of this if required In the event of any defective parts being found Airflow Developments Ltd reserve the right to repair or at our discretion replace without charge provided that the unit 1 Has been installed and used in accordance with the fitting and wiring instructions supplied with each unit 2 Has not been connected to an unsuitable electrical supply Has not been subjected to misuse neglect or damage 4 Has not been modified or repaired by any person not authorised by Airflow Developments Ltd 5 Has been installed in accordance with latest Building Regulations and IEEE wiring regulations Airflow Developments shall not be liable for any loss injury or other consequential damage in the event of a failure of the equipment or arising
7. ofitted The iCON Fan has an IP X4 rating housing and is suitable for mounting in Zone 1 or 2 in bathrooms toilets kitchens utility rooms and inside shower cubicles as defined in Section 701 BS7161 2008 IEEE wiring standards 17 Edition They also comply with the latest Building Regulations Do not place the ventilator near direct heat sources e g radiant heaters or where temperatures can exceed 40 C 104 F Page 2 of 8 AIRFLOW 4 The Fan requires a 230V 50Hz single phase supply Class Il equipment BS EN 60417 An external 3A fuse is required for each fan unit Note Switches for fans should be selected and sited in accordance with BS7161 2008 All electrical installation to be carried out by an approved electrician in accordance with Part P U K Building Regulations and to the latest IEEE standards or the appropriate regulations in the country of installation ALWAYS ISOLATE THE POWER SUPPLY UNIT AND FAN UNIT FROM THE POWER SUPPLY BEFORE REMOVING THE COVER Mechanical Installation iCON Domestic Fan can be recessed in a wall or ceiling A mounting skirt is provided for surface mounting the iCON 30 and iCON 60 CONDENSATION To avoid the backflow of condensation into the fan a in a ceiling installation it is good practice to fit a CONDENSATION TRAP to the outlet duct of the fan Ensure free running of the fan impeller and that flexible duct connections are not over tightened to the fan outlet spigot A
8. unted in Zones 1 amp 2 as defined in section 701 BS7161 2008 Additional protection must be provided by a Residual current device RCD with a rated residual operating current not exceeding 30mA Wiring with no control module fitted RCD i L O O 3 AMP SWITCHED FUSE Optional Modules for iCON and iCON eco 230V Wiring for control modules with external switching lt L 3 AMP SWITCHED FUSE 3 AMP SWITCHED FUSE Refer to instructions supplied with optional modules for further information Page 6 of 8 AIRFLOW Maintenance SAFETY FIRST ALWAYS ISOLATE THE FAN UNIT FROM THE POWER SUPPLY BEFORE REMOVING THE COVER Warranty only covers the fan not the reinstallation of this if required When installed according to these instructions the iCON Domestic Fans are completely safe The materials used do not constitute a hazard The module covers are made of a flame retardant material Cleaning e The external housing of the fan can be wiped with a damp cloth Do not use household cleaners containing abrasives e Cleaning of the internal parts such as the impeller should be carried out using a soft brush Note Always ensure that the fan unit is isolated from the power supply before inserting the brush into the impeller duct e Never clean any parts of the fan assembly by immersing in water or using a dishwasher Trouble shooting Tip Take care not to over tighten the duct connection to the fan spigot This ca