1. Door Adjustments 1 USER GUIDE U LINE u line com SAFETY INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE lt SERVIC 6 Install hinge on opposite side at bottom of cabinet 9 Remove plastic hole plug from door handle and Align hinge outer edge with cabinet before tightening relocate to opposite side Lift the handle slightly and screws press on the locking tab then gently pry the hole plug out of the hole being careful not scratch the top cap Hinge i 0 0 0 Plast Plast Hole Plug loo fol 1 Hole Plug M Screw Right Side A Sa Left Side Door Swing I lt Door Swing Right Side Invert Invert Hinge Screw Hinge 10 Remove pivot screw from top hinge invert screw and 7 Relocate plastic spacer bushing on top and bottom of reinstall pivot screw in top hinge door to opposite side Clean out bushing hole in door bottom with a screwdriver if necessary Sa oreo A hole plug and move to opposite side 11 Place door on lower hinge pin Invert and install upper hinge on door Fasten upper hinge to unit three 8 Using a Phillips screwdriver remove the two screws screws Partially tighten screws holding the handle K J W 12 Adjust door to ensure proper seal Tighten upper and lower hinge screws securely 13 Fill holes with remaining screws 14 Replace the grille Door Adjustments 2 USER GU
2. s Product Registration Card included with the ERATING INSTRUCTIONS MAINTENANCE SERVICE unit is completed and mailed back or electronically submitted to U Line This 30 day warranty does not apply to cosmetic damages A proof of purchase may be required The following conditions are excluded from this limited warranty use of cleaners other than the recommended stainless steel cleaners and U Line Clear Ice Maker cleaner installation charges damages caused by disasters or acts of God such as fire floods wind and lightning damages incurred or resulting from shipping improper installation unauthorized modification or misuse abuse of the product customer education calls food loss and spoilage door and water level adjustments except during the first 30 days from the date of installation defrosting the product adjusting the controls door reversal and cleaning the condenser U Line product are designed to operate in ambient temperatures between 50 F and 100 F unless otherwise noted in the product manual Exposure to temperatures outside this range may cause degradation of performance and issue such as lower ice production or spoiled contents are not covered under the terms of this warranty as a result of that exposure U Line product may not be subjected to temperatures below 40F without following the winterization and vacation shutdown procedures in the user guide U Line s Outdoor
3. ERATING INSTRUCTIONS MAINTENANCE SERVIC 3 Place bracket over holes and attach to unit with two screws removed in step 2 using a T 25 Torx driver Tighten screws fully Gently push units into position Be careful not to entangle the electrical cord or water line if applicable Re check the leveling from front to back and side to side Make any necessary adjustments The unit s top surface should be approximately 1 8 3 mm below the countertop Side by Side Installation 1 USER GUIDE U LINE u line com SAFETY INSTALLATION amp INTEGRATION lt OP General Installation LEVELING INFORMATION 1 Use a level to confirm the unit is level Level should be placed along top edge and side edge 1 lt gt as shown lt J ye Z T 2 24 gt 7 ae 2 If the unit is not level adjust the legs on the corners of the unit as necessary Turn to Adjust 3 Confirm the unit is level after each adjustment and repeat the previous steps until the unit is level INSTALLATION TIP If the room floor is higher than the floor in the cutout opening adjust the rear legs to achieve a total unit rear height of 1 8 3 mm less than the opening s rear height Shorten the unit height in the front by adjusting the front legs This allows the unit to be gently tipped into the opening Readjust the front legs to level the unit after it is co
4. INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE lt SERVIC Grille Plinth Installation REMOVING AND INSTALLING GRILLE Disconnect electric power to the unit before removing the grille DO NOT touch the condenser fins The condenser fins are SHARP and can be easily damaged Removing the grille 1 Disconnect power to the unit 2 Remove control knob 4 3 Loosen the two screws 1 4 Remove grille 2 and grille cap 3 from unit Installing the grille 1 Make sure grille cap 3 is behind grille in slots provided in grille before attaching grille to unit 2 Align cabinet and grille holes and secure but do not over tighten grille screws 1 3 Install control knob 4 if equipped 4 Reconnect power to the unit Grille Plinth Installation 1 USER GUIDE U LINE u line com SAFETY INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE lt SERVIC Door Swing All units have a zero clearance for the door to open 90 U Line recommends a minimum door clearance of 1 4 6 mm to accommodate the handle if the unit is installed next to a wall 1 4 Min 6 mm gt lt Q 90 Door Swing Door Swing 1 USER GUIDE U LINE u line com SAFETY INSTALLATION amp INTEGRATION
5. lt OP Integrated Panel Installation This model accepts a 1 4 insert panel INSERT PANEL INSTALLATION Install the insert as follows Use care when handling the insert Insert edges may be sharp 1 Remove top hinge screw pin with Phillips head screwdriver Remove door by tilting forward and lifting off bottom hinge pin 2 Pull door gasket out of groove top edge of door only Start in the middle and pull outward moving toward the edge This may take some force 3 Remove two outside screws holding door handle Slightly separate door handle from door 4 Pull handle up and off ERATING INSTRUCTIONS MAINTENANCE lt SERVIC 5 Slide custom channel in do NOTICE door panel insert into 1 4 6 mm or front Use care not to damage magnet located on door bottom when installing door insert Do not set door on bottom edge when pushing insert into place 6 Holding door door making gasket out of the way replace handle on sure it is seated properly on insert and that screw holes line up 7 Install two small screws removed in Step 3 8 Starting at th gasket into p 9 Place door on screw e corners and working inward push door ace on door bottom hinge pin and install upper hinge Integrated Panel Installation 1 USER GUIDE U LINE u line com SAFETY
6. display is flashing press i r to adjust the set point temperature point View temperature in unit Press Ganf together and release Ll The d isplay will flash and to temperature in unit then toggle from set point The d nits Hold Land for five seconds i i its Toggle between F C isplay will change u Control Operation 1 USER GUIDE U LINE u line com SAFETY INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE lt SERVIC Airflow and Product Loading NOTICE The unit requires proper airflow to perform at its highest efficiency Do not block the front grille or the unit will not perform as expected Do not install the unit behind a door When loading your unit leave space between the evaporator and product loaded Anything in direct contact with the evaporator is subject to freezing When properly loaded your U Line unit will store up to 48 12 oz 330 ml cans or 35 12 oz 330 ml bottles Airflow and Product Loading 1 USER GUIDE U LINE u line com SAFETY INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS MAIN Interior Shelves REMOVING AND INSTALLING INTERIOR SHELVES For models equipped with glass shelves having shelf supports remove the shelves as follows 1 Open d
7. lt OP Door Adjustments CHECKING DOOR ALIGNMENT The unit s door is aligned at the factory before shipment However its alignment could have been disturbed during shipment NOTICE Properly aligned the door s gasket should be firmly in contact with the cabinet all the way around the door no gaps 1 Carefully examine the door s gasket to ensure that it is firmly in contact with the cabinet 2 When inspecting door alignment make sure the door gasket is not pinched on the hinge side of the door ALIGNMENT AND ADJUSTMENT 1 Loosen do not remove top and bottom hinge screws 2 Align door squarely with cabinet Make sure gasket is firmly in contact with cabinet all the way around the door no gaps 3 Tighten bottom hinge screws 4 Tighten top hinge screws REVERSING THE DOOR Location of the unit may make it desirable to mount the door on the opposite side of the cabinet The hinge hardware will be removed and reinstalled on the opposite side of the cabinet ERATING INSTRUCTIONS MAINTENANCE lt SERVIC To reverse the door mounting perform the following 1 Remove grille see GRILLE PLINTH INSTALLATION 2 Remove top hinge from cabinet three screws Hold door to keep it from falling Hinge screws 3 Lift the door off the bottom hinge 4 Remove bottom hinge from cabinet two screws 5 Remove screws on opposite side of cabinet
8. statement may result in minor or moderate personal injury property or equipment damage A DANGER This unit contains R600a Isobutane which is a flammable hydrocarbon It is safe for regular use Do not use sharp objects to expedite defrosting Do not service without consulting the R600a specifications section included in the User Guide Do not damage the refrigerant circuit Service must be done by factory authorized service personnel Any parts shall be replaced with like components Failure to comply could increase the risk of possible ignition due to incorrect parts or improper service Safety and Warning 1 USER GUIDE U LINE u line com SAFETY INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVIC Disposal and Recycling A DANGER RISK OF CHILD ENTRAPMENT Before you throw away your old refrigerator or freezer take off the doors and leave shelves in place so children may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulations regarding the disposal and recycling of refrigeration appliances and follow these steps completely 1 Remove all consumable contents from the unit 2 Unplug the electrical cord from its socket 3 Remove the door s drawer s Disposal and Recycling 1 USER GUIDE U LINE u line com SAFETY INSTALLATION amp INTEG
9. Frequently Asked Questions are available at u line com under Customer Care or you may contact our Customer Care group directly contact information below GENERAL INQUIRIES SERVICE amp PARTS ASSISTANCE U Line Corporation Monday Friday 8 00 am to 5 30 pm CST 8900 N 55th Street T 1 800 779 2547 ilwaukee Wisconsin 53223 USA F 1 414 354 5696 onday Friday 8 00 am to 4 30 pm CST Service Email onlineservice u line com T 1 414 354 0300 Parts Email onlineparts u line com F 1 414 354 7905 Email sales u line com u line com CONNECT WITH US f w Z mad in L R blog Designed engineered and assembled in WI USA Introduction 1 USER GUIDE U LINE u line com SAFETY lt INSTALLATION amp INTEGRATION lt OPERATING INSTRUCTIONS lt MAINTENANCE SERVICE Safety and Warning NOTICE Please read all instructions before installing operating or servicing the appliance Use this appliance for its intended purpose only and follow these general precautions with those listed throughout this guide SAFETY ALERT DEFINITIONS Throughout this guide are safety items labeled with a Danger Warning or Caution based on the risk type A DANGER Danger means that failure to follow this safety statement will result in severe personal injury or death Warning means that failure to follow this safety statement could result in serious personal injury or death Caution means that failure to follow this safety
10. IDE U LINE u line com SAFETY INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE lt SERVIC First Use All U Line controls are preset at the factory Initial startup requires no adjustments NOTICE U Line recommends allowing the unit to run overnight before loading with product To turn the unit on or off Press the rocker switch located below the temperature control dial in the center of the grille CONTROL DIAL The control dial sets a single continuous temperature This set point temperature is a base setting used by the controller to maintain the temperature zone in the unit The factory default MID setting number 3 or 4 set point is approximately 38 F 3 C The set point temperature is a gauge for further temperature adjustments First Use 1 USER GUIDE U LINE u line com SAFETY lt INSTALLATION amp INT Control Operation Up Down EGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVIC Alert Not Light Power Used LED d 8S l F O ea CONTROL FUNCTION GUIDE FUNCTION COMMAND DISPLAY OPTIONS ON OFF Press and release Unit will immediately turn ON or OFF Press and release to leave interior Toggle lights Glass door wine and beverage centers only light on for 3 hours Adjust refrigerator set Press Jana and release When the F or C in th e
11. LIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE ALL OF WHICH ARE DISCLAIMED U Line s sole liability and your exclusive remedy under this warranty is set forth in the paragraphs above U Line shall have no liability whatsoever for any incidental consequential or special damages arising from the sale use or installation of the product or from any other cause whatsoever whether based on warranty express or implied or otherwise based on contract tort or any other theory of liability Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above limitations may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state Warranty 6 2014 Rev G NANC e SERVICE Warranty 2
12. Limited Warranty set forth in this Paragraph 6 shall apply to U Line models deemed suitable for outdoor use by Underwriters Laboratory UL as noted in the U Line Product Catalog U Line s website and or on the serial tag located inside the product A Outdoor product may come into contact with rain by virtue of outdoor use Exposure to other sources of water shall also cause this warranty to be void including flooding of the area in proximity of the unit greater than 1 8 deep in water hurricanes splashing of pool water or directing a spray from a hose or similar device into and around the unit Warranty 1 USER GUIDE U LINE u line com SAFETY s INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS lt MAINT 7 If a product defect is discovered during the applicable warranty period you must promptly notify either U Line at 8900 N 55th Street Milwaukee Wisconsin 53223 USA or at 1 800 779 2547 or the dealer from whom you purchased the product In no event shall such notification be received later than 30 days after the expiration of the applicable warranty period U Line may require that defective parts be returned at your expense to U Line s factory in Milwaukee Wisconsin for inspection Any action by you for breach of warranty must be commenced within one year after the applicable warranty period 8 THIS LIMITED WARRANTY IS IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMP
13. RATION OPERATING INSTRUCTIONS MAINTENANCE lt SERVIC Environmental Requirements This unit is designed to operate between 50 F 10 C and 100 F 37 C High ambient temperatures 100 F 37 C or higher may reduce the unit s ability to reach low temperatures For best performance keep the unit out of direct sunlight and away from heat generating equipment In climates where high humidity and dew points are present condensation may appear on outside surfaces This is considered normal The condensation will evaporate when the humidity drops Damages caused by ambient temperatures of 40 F 10 C or below are not covered by the warranty Environmental Requirements 1 USER GUIDE L LJ LINE u line com SAFETY INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS MAINT Electrical SHOCK HAZARD Electrical Grounding Required Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected Never remove the round grounding prong from the plug and never use a two prong grounding adapter Altering cutting or removing power cord removing power plug or direct wiring can cause serious injury fire loss of property and or life and will void the warranty Never use an extension cord to connect power to the unit Always keep your working area dry NOTICE Electrical installation must observe all state and local c
14. USER GUIDE SAFETY e INSTALLATION amp INT EGRATION s OP ERATING INSTRUCTIONS s MAINTENANC e SERVIC ae _ g b w ADA Height Compliant Series e 29R lt 21 Solid Door Refrigerator USER GUIDE U LINE u line com SAFETY e INSTALLATION amp INTEGRATION lt OPERATING INSTRUCTIONS MAINTENANCE SERVIC Contents Intro Service Troubleshooting Safety Warranty Safety and Warning Disposal Installation Environmental Requirements Electrical Cutout Dimensions Product Dimensions Side by Side Installation General Installation Integrated Panel Dimensions Integrated Panel Installation Grille Plinth Installation Door Swing Door Adjust Operating Instructions First Use Control Operation Airflow and Product Loading Interior Shelves Door Shelves Maintenance Cleaning Cleaning Condenser Extended Non Use USER GUIDE U LINE u line com WELCOME TO U LINE Congratulations on your U Line purchase Your product comes from a company with over five decades and three generations of premium modular ice making refrigeration and wine preservation experience U Line continues to be the American leader delivering versatility and flexibility for multiple applications including residential light commercial outdoor and marine use U Line s complete product collection includes modular Wine Captain Model
15. d or abrasive cleaners Use a soft sponge and rinse with clean water Wipe with a soft clean towel to prevent water spotting Clean any glass surfaces with a non chlorine glass cleaner Stainless Models Stainless door panels handles and frames can discolor when exposed to chlorine gas pool chemicals saltwater or cleaners with bleach Keep your stainless unit looking new by cleaning with a good quality all in one stainless steel cleaner and polish monthly For best results use Claire Stainless Steel Polish and Cleaner which can be purchased from U Line Corporation Part Number 173348 Comparable products are acceptable Frequent cleaning will remove surface contamination that could lead to rust Some installations may require cleaning weekly Do not clean with steel wool pads Do not use stainless steel cleaners polishes on any glass surfaces Clean any glass surfaces with a non chlorine glass cleaner Do not use cleaners not specifically intended for stainless steel on stainless surfaces this includes glass tile and counter cleaners ERATING INSTRUCTIONS lt MAINTENANCE SERVIC If any surface discoloring or rusting appears clean it quickly with Bon Ami or Barkeepers Friend Cleanser and a nonabrasive cloth Always clean with the grain Always finish with Claire Stainless Steel Polish and Cleaner or comparable product to prevent further problems Using abrasive pads such as Scotchbrit
16. e will cause the graining in the stainless steel to become blurred Rust not cleaned up promptly can penetrate the surface of the stainless steel and complete removal of the rust may not be possible Integrated Models To clean integrated panels use household cleaner per the cabinet manufacturer s recommendation INTERIOR CLEANING Disconnect power to the unit Clean the interior and all removed components using a mild nonabrasive detergent and warm water solution applied with a soft sponge or non abrasive cloth Rinse the interior using a soft sponge and clean water Do not use any solvent based or abrasive cleaners These types of cleaners may transfer taste to the interior products and damage or discolor the interior DEFROSTING Under normal conditions this unit does not require manual defrosting Minor frost on the rear wall or visible through the evaporator plate vents is normal and will melt during each off cycle If there is excessive build up of 1 4 6 mm or more manually defrost the unit Ensure the door is closing and sealing properly Cleaning 1 USER GUIDE L LJ LINE u line com ETY s INSTALLATION amp INT SAF EGRATION lt OP High ambient temperature and excessive humidity can also produce frost DO NOT use an ice pick or other sharp instrument to help speed up defrosting These instruments can puncture the inner lining or damage the cooling unit DO NOT use any type
17. er unit 1 Remove the grille See GRILLE PLINTH INSTALLATION 2 Clean the condenser coil using a using a soft brush with a combing action or vacuum cleaner Do not touch the condenser coil 3 Install the grille Condenser Cleaning Condenser 1 USER GUIDE U LINE u line com SAF ETY INSTALLATION amp INT Extended Non Use EGRATION lt OP STORAGE VACATION AND MOVING If not using the unit for an extended period or otherwise stored follow these steps completely Electrical Shock Hazard Disconnect power before servicing Before operating replace all panels Failure to do so may result in electrical shock or death NOTICE If the ambient temperature is expected to drop below 50 F 10 C turn off and unplug unit 1 Remove all consumable content from the unit ERATING INSTRUCTIONS MAINTENANCE lt S RVIC 5 During periods of non use the cabinet must remain open to prevent formation of mold and mildew Open door a minimum of 2 in 5 cm to provide the necessary ventilation 2 Disconnect the power cord from its outlet and leave it disconnected until the unit is returned to service 3 If ice is on the evaporator allow ice to thaw naturally DO NOT use an ice pick or other sharp instrument to help speed up defrosting These instruments can puncture t
18. es for all U Line products U Line shall 1 repair any product or replace any part of a product and 2 for all Marine RV and Domestic U Line products sold and serviced in the United States including Alaska and Hawaii and Canada U Line shall be responsible for the labor costs performed by a U Line authorized service company incurred in connection with the replacement of any defective part During years two through five of the warranty period for the sealed system U Line shall 1 at U Line s option repair or replace any part of the sealed system and 2 for all Marine RV and Domestic U Line products sold and serviced in the United States including Alaska and Hawaii and Canada U Line shall be responsible for the labor costs incurred in connection with the replacement of any defective part of the sealed system All other charges including transportation charges for replacements under this warranty and labor costs not specifically covered by this warranty shall be the responsibility of the purchaser This warranty extends only to the original purchaser of the U Line product The Product Registration Card included with the product should be promptly completed by you and mailed back to U Line or you can register on line at www u lineservice com The warranty listed above does not apply to floor display models The warranty for these models shall be 30 days from the date of retail purchase and only if U Line
19. he inner lining or damage the cooling unit DO NOT use any type of heater to defrost Using a heater to speed up defrosting can cause personal injury and damage to the inner lining 4 Clean and dry the interior of the cabinet Ensure all water has been removed from the unit Extended Non Use 1 USER GUIDE U LINE u line com SAFETY INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Troubleshooting BEFORE CALLING FOR SERVICE If you think your U Line product is malfunctioning read the CONTROL OPERATION section to clearly understand the function of the control If the problem persists read the NORMAL OPERATING SOUNDS and TROUBLESHOOTING GUIDE sections below to help you quickly identify common problems and possible causes and remedies Most often this will resolve the problem without the need to call for service IF SERVICE IS REQUIRED If you do not understand a troubleshooting remedy or your product needs service contact U Line Corporation directly at 1 800 779 2547 When you call you will need your product Model and Serial Numbers This information appears on the Model and Serial number plate located on the upper right or rear wall of the interior of your product NORMAL OPERATING SOUNDS All models incorporate rigid foam insulated cabinets to provide high thermal efficiency and maximum sound reduction for its internal working components Despite this techn
20. n in direct sunlight or near a heat source open CHECKING PRODUCT TEMPERATURE l K l l l e The time the internal light is illuminated This mainly affects product on the top rack or shelf e Obstruction of front grille or condenser To check the actual product temperature in the unit 1 Partially fill a plastic nonbreakable bottle with water 2 Insert an accurate thermometer 3 Tighten the bottle cap securely 4 Place the bottle in the desired area for 24 hours 5 Avoid opening the unit during the testing period 6 After 24 hours check the temperature of the water If required adjust the temperature control in a small increment see CONTROL OPERATION Troubleshooting 2 USER GUIDE U LINE u line com SAFETY s INSTALLATION amp INTEGRATION lt OP Warranty U LINE CORPORATION LIMITED WARRANTY 1 U Line Corporation U Line warrants each U Line product to be free from defects in materials and workmanship for a period of one year two years on Modular 3000 Series from the date of purchase U Line further warrants the sealed system consisting of the compressor condenser evaporator hot gas bypass valve dryer and connecting tube in each U Line product to be free from defects in materials and workmanship for a period of five years from the date of purchase During the initial one year warranty period two years on Modular 3000 Seri
21. odes This unit requires connection to a grounded three prong polarized receptacle that has been placed by a qualified electrician The unit requires a grounded and polarized 115 VAC 60 Hz 15A power supply normal household current An individual properly grounded branch circuit or circuit breaker is recommended A GFCI ground fault circuit interrupter is usually not required for fixed location appliances and is not recommended for your unit because it could be prone to nuisance tripping However be sure to consult your local codes See CUTOUT DIMENSIONS for recommended receptacle location NANC e SERVIC Electrical 1 USER GUIDE L U LINE u line com SAFETY INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS MAINT Cutout Dimensions PREPARE SITE Your U Line product has been designed for either free standing or built in installation When built in your unit does not require additional air space for top sides or rear However the front grilla must NOT be obstructed and clearance is required for an electrical connection in the rear Unit can NOT be installed behind a closed cabinet door Never remove the round grounding prong from the plug and never use a two prong grounding adapter Never use an extension cord to connect power to the unit CUT OUT DIMENSIONS Filler Panel Not Provided by U Line May Be Added Above or Below Unit to Encl
22. of heater to defrost Using a heater to speed up defrosting can cause personal injury and damage to the inner lining NOTICE The drain pan was not designed to capture the water created when manually defrosting To prevent water from overflowing the drain pan place towels or other absorbent materials over the interior drain trough under the evaporator before defrosting To defrost 1 Disconnect power to the unit 2 Remove all products from the interior 3 Prop the door in an open position 2 in 50 mm minimum 4 Allow the frost to melt naturally 5 After the frost melts completely clean the interior and all removed components See INTERIOR CLEANING When the interior is dry reconnect power and turn unit on ERATING INSTRUCTIONS lt MAINTENANCE lt S RVIC Cleaning 2 USER GUIDE U LINE u line com SAFETY INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVIC Cleaning Condenser INTERVAL EVERY SIX MONTHS To maintain operational efficiency keep the front grille free of dust and lint and clean the condenser when necessary Depending on environmental conditions more or less frequent cleaning may be necessary Disconnect electric power to the unit before cleaning the condenser DO NOT touch the condenser fins The condenser fins are SHARP and can be easily damaged NOTICE DO NOT use any type of cleaner on the condens
23. ology your model may make sounds that are unfamiliar Normal operating sounds may be more noticeable because of the unit s environment Hard surfaces such as cabinets wood vinyl or tiled floors and paneled walls have a tendency to reflect normal appliance operating noises Listed below are common refrigeration components with a brief description of the normal operating sounds they make NOTE Your product may not contain all the components listed e Compressor The compressor makes a hum or pulsing sound that may be heard when it operates e Evaporator Refrigerant flowing through an evaporator may sound like boiling liquid e Condenser Fan Air moving through a condenser may be heard e Automatic Defrost Drain Pan Water may be heard dripping or running into the drain pan when the unit is in the defrost cycle TROUBLESHOOTING GUIDE A DANGER ELECTROCUTION HAZARD Never attempt to repair or perform maintenance on the unit before disconnecting the main electrical power Troubleshooting What to check when problems occur Problem Possible Cause and Remedy nterior Light If the unit is cooling it may be in Sabbath Does Not mode Illuminate Light Remains Turn off light switch if equipped on When Door Is Adjust light actuator bracket on bottom of a Closed door Unit Develops Frost on the rear wall is normal and will melt Frost on Internal during each off cycle Su
24. oor completely 2 Grasp the shelf edge in the center and slide the shelf from the unit Insert the shelves as follows 1 With the door still fully opened reposition the shelf as required ensure the raised white edge strip is toward the rear of the unit and slide the shelf back into position NOTICE Make sure the shelves are inserted fully into the unit The edge strip toward the rear prevents cans and bottles from freezing against the cold evaporator NANCE SERVIC Interior Shelves 1 USER GUIDE U LIN E u line com SAFETY s INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS lt MAINTENANCE s SERVIC Door Shelves REMOVING AND INSTALLING DOOR SHELVES 1 Ops s a 7 SN L in q To remove the door shelf 1 Grasp shelf in center and lift until the shelf notches 1 clear the pins 2 2 Carefully pull the shelf away from the door To insta 1 Holdi door 2 the door shelf ng the shelf in the center center the shelf in the at the desired location slightly above the pins 2 Lower the shelf onto the pins 2 Door Shelves 1 USER GUIDE U LINE u line com SAFETY lt INSTALLATION amp INTEGRATION lt OP Cleaning EXTERIOR CLEANING Vinyl Clad Black or White Clean surfaces with a mild detergent and warm water solution Do not use solvent base
25. ose for a Built In Look Typical Counter Height 34 1 4 Preferred location 5 8 24 870 mm for electrical outlet 16 mm 610 mm to is in adjacent eee cabinet Cut Out Height 7 A 108 mm y to e 28 7 8 733 mm A 1 1 2 38 mm y 21 1 16 gt 535 mm NANC e SERVIC Cutout Dimensions 1 USER GUIDE U LINE u line com SAFETY INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE lt SERVIC Product Dimensions 28 1 2 724 mm 4 9 16 116 mm ee 20 7 8 530 mm ur Product Dimensions 1 USER GUIDE U LINE u line com SAFETY INSTALLATION amp INTEGRATION lt OP Side by Side Installation Two units may be installed side by side Cutout width for a side by side installation is the cutout dimension of a single unit times two No trim kit is required However 1 4 6 mm of space needs to be maintained between the units to ensure unobstructed door swing Units must operate from separate properly grounded electrical receptacles placed according to each unit s electrical specifications requirements Side by Side Installation with Bracket 1 Slide both units out so screws on top of units are easily accessible 2 Remove screws as shown below
26. rfaces f there is excessive build up of 1 4 or more manually defrost the unit Ensure the door is closing and sealing properly High ambient temperature and excessive humidity can also produce frost Unit Develops The unit is exposed to excessive humidity Condensation on Moisture will dissipate as humidity levels External decrease Surfaces Product Is Because product in contact with the rear wall Freezing may freeze ensure no product is touching the rear wall Adjust the temperature to a warmer set point Troubleshooting 1 USER GUIDE U LINE u line com SAFETY s INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Causes which affect the internal temperatures of Problem Possible Cause and Remedy 9 the cabinet include Product Is Not Air temperature does not indicate product Cold Enough temperature See CHECKING PRODUCT s Temperature setting TEMPERATURE below Adjust the temperate to a cooler set point S e Ambient temperature where installed ambient temperatures or in direct sunlight Ensure the door is closing and sealing properly Ensure the interior light has not remained on too long Ensure nothing is blocking the front grille found at the bottom of the unit e The number of door openings and the time the door is Ensure the condenser coil is clean and free of any dirt or lint build up e Installatio
27. rrectly positioned in the opening ERATING INSTRUCTIONS MAINTENANCE lt SERVIC INSTALLATION 1 Plug in the power electrical cord Gently push the unit into position Be careful not to entangle the power cord Re check the leveling from front to back and side to side Make any necessary adjustments The unit s top surface should be approximately 1 8 3 mm below the countertop Remove the interior packing material and wipe out the inside of the unit with a clean water dampened cloth General Installation 1 USER GUIDE U LINE u line com SAFETY INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVIC Integrated Panel Dimensions INSERT CUSTOM 1 4 THICK DOOR PANEL Insert Panel Preparation A custom door panel may be inserted into the door frame Custom door panels can be flat or raised as long as the maximum panel thickness where inserted into the door reveal channel is no more than 1 4 thick For raised panels the depth of the reveal is 1 4 on all four sides NOTICE Raised panels will reduce the door s 90 swing zero clearance if the unit is installed next to a wall or similar type of structure Panel Dimensions Width Height 19 13 16 503 mm 21 13 32 544 mm Integrated Panel Dimensions 1 USER GUIDE U LINE u line com SAFETY INSTALLATION amp INTEGRATION
28. s Beverage Centers Clear Ice Machines Crescent Ice Makers Glass amp Solid Door Refrigerators Drawer Models Freezers and Combo Models U Line has captivated those with an appreciation for the finer things with exceptional functionality style inspired innovations and attention to even the smallest details We are Known and respected for our unwavering dedication to product design quality and selection U Line is headquartered in Milwaukee Wisconsin with a west coast office located in Laguna Beach California and European support in Dublin Ireland U Line has shipped product to five continents for over two decades and is proud to have the opportunity to ship to you PRODUCT INFORMATION Looking for additional information on your product User Guides Quick Reference Guides CAD Drawings Compliance Documentation and Product Warranty information are all available for reference and download at u line com under Documentation PROPERTY DAMAGE INJURY CONCERNS In the unlikely event property damage or personal injury is suspected related to a U Line product please take the following steps 1 U Line Customer Care must be contacted immediately at 1 800 779 2547 2 Service or repairs performed on the unit without prior written approval from U Line is not permitted If the unit has been altered or repaired in the field without prior written approval from U Line claims will not be eligible SERVICE INFORMATION Answers to Customer