Home
        GENIE® - Linde
         Contents
1.  Gas type    E  Number of black bars indicates the contents remaining    Start up screen for the Shielding gas GENIE  Flow rate units   Welding flow rate   Arrow shows direction of next flow rate    El Gas type  Value is the number of minutes welding time left  f Number of black bars indicates the contents remaining    Start up screen for the nitrogen  N   GENIE cylin  Cylinder pressure when full   this valve  doesn   t change when in use          Start up screen for helium  He   balloon gas  GENIE   cylinder    Arrow shows direction of next balloon size rie      Balloon size chosen shows in black  The approximate number of balloons that  can be filled with the remaining gas at  the selected balloon size  El Number of black bars indicates the contents remaining       03    Extra small balloons  XS  are between 80 and 179mm  3 to 7     diameter  Small balloons  S  are between 180 and 240mm  7 1 to 9 5   diameter  Medium balloons  M  are between 250 and 350mm  10 to 14     diameter  Large balloons  L  are between 380 and 480mm  15 to 18 5   diameter  Extra large balloons  XL  are between 500 and 700mm  19 to 27 5   diameter    If you have a helium balloon gas or shielding gas GENIE cylinder  a  balloon size or gas flow rate will have been pre selected  To change this   select the direction of the arrow as needed by pressing and holding the  button down  increase   ff and decrease   4   Then press the button to  select the required size of balloon or welding flow rate    160 3s 
2. Shielding gas screen showing welding time left at 16 I     min  Arrow denotes if button is pressed next value will  be 15 l min            Shielding gas screen showing welding time left at 15  l min  Arrow denotes if button is pressed next value  will be 16 l min     Please note  The readouts for the number of balloons that can be filled  or the welding time remaining are for indication purposes only and  should not be taken as absolute value or guarantee  Changing the value  on the display does not alter the actual flow rate from the unit     Alarms    There are three audio and visual alarms on the DIU   At 25  full  the alarm sounds and warning LED flashes twice for  0 2 seconds followed by a 1 second gap then twice again  The bars  on the cylinder graphic also flash  At 10  full  the alarm sounds and warning LED flashes twice for  0 5 seconds with a 0 5 second gap  The bar on the cylinder graphic  also flash  At empty the alarm sounds and warning LED flashes twice cylinder  symbol also flashes     Please note  These alarms only occur the first time the GENIE cylinder  is turned on after an alarm condition is met     04 GENIE   cylinder user manual    Error message    Should a problem occur with the DIU an error screen will appear   The GENIE is still safe to use but no information about the contents  will be available     Example of an error screen  Cylinder pressure when full  Version number   Error code   ZY Serial number    DIU has no user serviceable components and und
3. THE LINDE GROUP       Lintle    GENIE      Cylinder user manual     Smart  Convenient  Portable     Safety    The GENIE cylinder has been designed to the required EN and ISO  standards  It contains gases at high pressure and should be treated  with care and caution  It is important that you read this manual before  using this product for the first time to ensure you are familiar with all  the product features  operating instructions and guidelines for use     Handling and transportation    The GENIE cylinder handle has also been designed as a guard to protect   the cylinder valve from accidental damage    GENIE cylinders should always be transported and used in an upright   position  never on their side or inverted    A NEVER use cylinder handles as lifting points for cables  straps  crane  hooks or anything other than hands     02 GENIE   cylinder user manual    Displays    Digital display   The Digital Intelligence Unit  DIU  display differs  depending on the  gas supplied  It provides information on how much gas is left in the  cylinder  When gas levels get below 25  and 10   an alarm and  flashing light indicate this     Operation  To start push the button on the DIU to initiate the  display  After 3 seconds the start up screen will  change to one of the versions below  depending on  the type of gas the cylinder contains  The DIU only  remains active for 40 seconds before shutting down  if no further operations have been carried out   der  Percentage of contents left Eie 
4. damaged   2  Clean the cylinder valve and regulator threads using a dry  clean  piece of lint free cloth to remove dirt  moisture  oil and grease  particles   3  Carefully locate regulator seats into the valve  place the nut over   the threads ensuring that you do not cross thread  and tighten with   the appropriate spanner   DO NOT OVERTIGHTEN  as this will damage your regulator    Turn the regulator knob counter clockwise until it stops   Slowly open the cylinder value   Turn the regulator knob clockwise to set normal delivery pres    sure or flow   A  NEVER dismantle or modify a regulator to make it fit    A NEVER use adaptors between the cylinder valve and the regulator  to make it fit    A NEVER use oil or lubricants on the cylinder valve or regulator threads   Oil or lubricants can trap dirt and make the regulator difficult to fit  or leak  they can also be carried into the regulator and cause a mal   function  If the cylinder contains oxygen then any oil or lubricants  will ignite in the presence of oxygen     NOW S    Only enough force should be used to provide a leak tight seal between  the cylinder valve and the regulator  If excessive force is use the cylin   der may move within its outer jacket  While this is not a safety hazard   should this occur it is an indication that excessive force has been used  in tightening the regulator to the cylinder     06 GENIE   cylinder user manual    Removing regulators   1  Close the cylinder valve   2  Release all gas from the 
5. er no circumstances  should any attempt be made to open or interfere with the DIU unit     Accessories    Use only approved GENIE accessories  as non approved items may dam   age the cylinder and you may be charged a fee to repair the cylinder   Each accessory comes with its own instructions and warranty  Please  ensure that you read these thoroughly before using the product     Using your GENIE    Before using your GENIE cylinder  you will need to attach a regulator   or in the case of helium used as a balloon gas  a balloon inflator   The regulators and inflators come with their own instructions     GENIE regulators    Safety is priority for Linde  Therefore  the GENIE cylinder handles have  been specifically designed to protect the valve and regulator  Only  GENIE gas and pressure specific regulators should be used to guarantee  performance and genuine products should be used at all times        05    Range of regulators    Gas type Max Model Genie   Outlet Delivery          inlet regulator connec range   pressure description tion  Ar  Mist  Ar 300 bar GAr 300 30 3 F  1G  SG G 3 8 0 30 Ipm  N  300 bar GN2 300 30 3 P  1G  N  G 3 8 0 10 bar     F   Flow  G   Gauge  SG   Shielding gas  P   Pressure    Fitting regulators  Regulators are designed for use with specific gases or groups of gases  and must only be fitted to their respective cylinders     1  Ensure the regulator is in good condition before fitting to the cylin   der  Gauges should be intact with threads and seats un
6. inder if that  cylinder is fitted with the same valve    Q  Why is the cylinder more stable    A  The diameter of 320 mm gives the cylinder more stability  the  cylinder is less likely to topple over    Q  Where can I buy GENIE    A  Contact Linde on  351 218 310 424   Q  Where can I buy GENIE accessories    A  Contact Linde on  351 218 310 424   P  Who should   contact to report a damaged faulty cylinder    R  Contact Linde on  351 218 310 424    Information and support    For other queries please call our Customer Service Center on   351 218 310 424     Linde Portugal  Lda   Av  Infante D  Henrique  Lt  21 24  1800 217 Lisbon  Tel  Lisbon  351 218 310 424  Tel  Porto  351 229 998 380  www linde pt    8208 EN 01 14    
7. nd in case of damage  you might be charged for the repair  of the cylinder     Know your GENIE             HDPE jacket   Rugged wheel unit   Colored gas hazard identification ring   Ergonomically designed handles and valve protection  Digital Information Unit  DIU    High performance regulator    E  4    a    Technical data    Pressure Capacity Diameter Height Empty Content                weight  Gas type  bar   1   mm   mm   kg   kg m    Argon 300 10 320 570 159 3 0 m   Corgon 18 300 20 320 662 22 6 7 m   Nitrogen 300 20 320 662 22 5 2 m      Helium 200 20 320 662 22 3 6 m        Troubleshooting    The Digital Intelligence Unit will not display   Press the button once  firmly in the centre  If the unit fails to display  the  cylinder will be safe to use but no contents information will be available     08    FAQ s   Q  Does a normal regulator fit within the handle area    A  No  existing regulators are too big to fit within the space between  the handles of the GENIE cylinder  GENIE regulators are compact  versions of the larger regulators  specifically designed to meet the  requirements of this type of cylinder  The small size of the GENIE  regulator has the advantage of being within the handle area   which means the regulator should not get damaged  should the  cylinder be pushed over    Q  Do the GENIE regulators fit on the current steel cylinders    A  Yes  although they have been specifically designed for use with  a GENIE cylinder  they will fit on a standard steel cyl
8. regulator and system until the gauge s   read zero  by turning the regulator knob counter clockwise until  it stops   3  Close the outlet valve of the regulator  if any    4  Loosen the regulator using the appropriate spanner and then  remove the regulator  Store the regulator in its box  in a clean   dry environment     Wheel unit  GENIE is equipped with a rugged wheel unit that must not be  removed     Daily cylinder use   GENIE cylinders are designed for either continuous or intermittent use   At the end of any period of use  or when you are leaving the cylinder  Unattended  close the cylinder valve by turning the wheel in a clock   wise direction     Children and GENIE cylinder  Children should never be allowed to use or operate a GENIE cylinder   Maintenance and care    The GENIE cylinder has been designed to require no maintenance from  the customer at all    While the HDPE cylinder jacket has been made as strong and durable  as possible  it can still be damaged by misuse    Should you wish to clean the GENIE cylinder  use a mild detergent  such as washing up liquid diluted with warm water  Use a clean cloth  to sponge the GENIE cylinder clean    A NEVER immerse a GENIE cylinder in water    A NEVER use a power washer on a GENIE cylinder       NEVER use chemicals or solvents on a GENIE cylinder        07    Damage    Check the GENIE cylinder for damage before leaving your Linde collec  tion point  When returning the GENIE cylinder  the unit will be checked  for damage  a
    