Manual MS655200(x)
Contents
1. 0Mbps connections 100 Category 5 cable for 100Mbps or 100 Category 5e above cable for 1000Mbps connections The cable between the switch and the link partner switch hub workstation etc must be less than 100 meters 328 ft long MICROSENS Mounting Installation DIN Rail Mounting The DIN Rail is screwed on the industrial switch when out of factory If the DIN Rail is not screwed on the industrial switch please see the following figure to screw the DIN Rail on the switch Follow the steps below to hang the industrial switch Rear Panel of the switch DIN Rail 1 Use the screws to screw on the DIN Rail on the industrial switch 2 To remove the DIN Rail reverse step 1 MICROSENS 3 First insert the top of DIN Rail into the track 4 Then lightly push the button of DIN Rail into the track 5 Check the DIN Rail is tightly on the track 6 To remove the industrial switch from the track reverse the steps above MICROSENS Wall Mount Plate Mounting Follow the steps below to mount the industrial switch with wall mount plate 1 S Remove the DIN Rail from the industrial switch loose the screws to remove the DIN Rail Place the wall mount plate on the rear panel of the industrial switch Use the screws to screw the wall mount plate on the industrial switch Use the hook holes at the corners of the wall mount plate to hang the industrial switch on the wall To remove the wall mount pla
2. DC wires to loose 6 MICROSENS Wiring the Fault Alarm Contact The fault alarm contact is in the middle of terminal block connector as the picture shows below Inserting the wires it will detect the fault status which the power is failure or port link failure for managed model and form an open circuit Note The wire gauge for the terminal block should be in the range between 12 24 AWG LED Indicators There are few LEDs display the power status and network status located on the front panel of the Industrial switch each of them has its own specific meaning as below table LED Color Description On Power input 1 is active 1 Green Off Power input 1 is inactive On Power input 2 is active P2 Green Off Power input 2 is inactive On Power input 1 or 2 is inactive Fault Red Off Power input 1 and 2 are both functional or no power MICROSENS inputs 1 5 Upper LED On Connected to network Green Flashing Networking is active at speed of 100Mbps Off Not connected to network 1 5 T On Connected to network at speed of 1000Mbps reen Lower LED Off Not connected to network Ports RJ 45 ports Auto MDI MDIX The RJ 45 ports are auto sensing for 10Base T 100Base TX or 100Base T devices connections Auto MDI MDIX means that you can connect to another switch or workstation without changing straight through or crossover cabling See figures as
3. MICROSENS 5 10 100 1000T Industrial Switch User Manual MS655200 MICROSENS Content BM T M 1 Kgiigele Blelt 6 p emt MN T NN 1 FEAU S ERU 3 uon 4 Safety Precaution ccccccccccccccccccceceeeeeeeeeeeeeeeeeeeeeess 4 Hardware Description 5 Front F Aine ER 5 TOD VIOW 6 Wiring the 6 Wiring the Fault Alarm Contact 7 LED WACIC ALONG eM T 7 jog cg CPU Y 8 e Pm 9 Mounting Installation 10 DINSPIEMOBUDIEIG d sadi ie esee euntes v ted 10 Wall Mount Plate Mounting 12 Hardware Installation 13 Installation Steps Troubles shooting Technical Specification MICROSENS Overview Introduction The unmanaged industrial switch is a cost effective solution and meets the high reliability requirements demanded by industrial applications High Speed Transmissions The Industrial switch includes a switch controller that can automatically sense transmission speeds 10 100 1000 Mbps The RJ 45 interface can also be auto detected so MDI or MDI X is automatically selected and a crossover cable is not required All Ethernet ports have memory buffers that support the store and forward mechanis
4. below for straight through and crossover cable schematic RJ 45 Pin Assignments Note Pin Number Assignment 1 2 3 6 Rx and signs represent the polarity of the wires that make up each wire pair All ports on this industrial switch support automatic MDI MDI X operation you can use straight through cables See Figure below for all network connections to PCs or servers or to other switches or hubs In straight through cable pins 1 2 3 and 6 at one end of the cable are connected straight through to pins 1 2 3 and 6 at the other end of the cable The table below shows the 10BASE T 100BASE TX MDI and MDI X port pin outs MICROSENS Pin MDI X Signal Name Receive Data plus RD MDI Signal Name Transmit Data plus TD Receive Data minus RD Transmit Data minus TD Transmit Data plus TD Receive Data plus RD OW N Transmit Data minus TD Receive Data minus RD Cabling Switch Router or PC 3 TD 3 RD 6 TD 6 RD 1 RD TD 2 RD 4 2 TD Straight Through Cable Schematic Switch 3 TD 3 6 TD 6 1 RD 2 RD Switch TD TD RD 2 RD Cross Over Cable Schematic Use unshielded twisted pair UTP or shielded twisted pair STP cable for RJ 45 connections 1000 Category 3 4 or 5 cable for 1
5. e CE EN61000 4 6 CS CE EN61000 4 8 EN61000 4 11 CE EN61000 4 12 CE EN61000 6 2 CE EN61000 6 4 17 MICROSENS Free Fall IEC60068 2 32 Shock IEC60068 2 27 Vibration IEC60068 2 6
6. er Supports Jumbo Frame of 9Kbytes Supports surge EFT protection 3 000 Vpc for power line Supports 6 000 Ethernet ESD protection Supports redundant 12 48 power input Provides flexible mounting DIN rail Panel Mounting Supports operating temperatures from 40 75 C wide operating temperature model or 10 60 C standard model MICROSENS Packing List 1 5 10 100 1000Base T Industrial Ethernet Switch B 1x User Manual m 2x Wall Mounting Bracket and Screws Safety Precaution Attention IF DC voltage is supplied by an external circuit please use a protection device on the power supply input MICROSENS Hardware Description In this paragraph we will introduce the Industrial switch s hardware spec port cabling information and wiring installation Front Panel The Front Panel of the 5 port 10 100 1000Base T Industrial Switch is shown as below Front Panel of the 5 port 10 100 1000Base T Industrial Switch MICROSENS Top View The top panel of the 5 port 10 100 1000Base T Industrial Switch is equipped one terminal block connector of two DC power inputs Top panel of the 5 port 10 100 1000BaseTX Industrial Switch Wiring the Power Inputs Please follow the steps below to insert the power wire V V V V 1 Insert the positive and negative wires into the V and V contacts on the terminal block connector 2 To tighten the wire clamp screws for preventing the
7. m This assures that data is properly transmitted Dual Power Input To reduce the risk of power failure the Industrial switch provides 12 48 Vpc dual power inputs If there is power failure Industrial switch will automatically switch to the secondary power input Flexible Mounting The industrial switch is extremely compact and can be mounted on a DIN rail or a panel so it is suitable for any space constrained environment Advanced Protection The power line of Industrial switch supports up to 3 000 VDC EFT protection which secure equipment against unregulated voltage and make systems safer and more reliable Meanwhile 6 000 VDC ESD protections for Ethernet ports make Industrial switch more suitable for harsh environments MICROSENS Wide Operating Temperature The operating temperature of the Industrial switch is between 40 75 C wide operating temperature model or 10 60 C standard model With such a wide range you can use the Industrial switch in some of the harshest industrial environments that exist Easy Troubleshooting LED indicators make troubleshooting quick and easy Each 10 100 1000T port has 2 LEDs that display the link status and transmission speed Also the three power indicators P1 P2 and Fault help you diagnose immediately MICROSENS Features Provides 5 x 10 100 1000Base T Mbps Ethernet ports Supports full half duplex flow control Supports auto negotiation Supports MDI MDI X auto crossov
8. r surges at power outlet IF you still cannot resolve the problem contact your local dealer for assistance If the Industrial switch LED indicators are normal and the connected cables are correct and the packets still cannot transmit Please check your system s Ethernet devices configuration or status MICROSENS Technical Specification The technical specifications of the Industrial Switch are listed as follows Communications Compatibility LAN Transmission Distance Transmission Speed Interface Connectors LED Indicators Power Power Consumption Power Input Fault Output Mechanism IEEE 802 3 802 3u 802 3ab IEEE 802 3x 10 100 1000Base T Up to 100 m Up to 1000 Mbps 5 x RJ 45 5 10 100 1000TX 6 pin removable screw terminal power amp relay Unit P1 P2 Fault Ethernet port Link Active 100Mbps Link 1000Mbps 4 6W 2 x Unregulated 12 48 Vpc 1 Relay Output Dimensions WxDxH Enclosure Protection ESD Ethernet Surge EFT for power Power Reverse Environment Operating Temperature Operating Humidity Storage Temperature Certifications Safety EMC MICROSENS 30 x 95 x 140 mm IP 30 Metal shell with solid mounting kits 6 000 Vpc 3 000 Vpc Yes 40 75 C wide operating temp model 10 60 C standard model 5 95 non condensing 40 85 C CE EN60950 1 CE EN61000 4 2 ESD CE EN61000 4 3 RS CE EN61000 4 4 EFT CE EN61000 4 5 Surg
9. t port RJ 45 port and another side of category 5e or above cables to the network devices Ethernet port RJ 45 port ex switch Pc or Server The UTP port RJ 45 LED on the Industrial switch will light up when the cable connected with the network device Please refer to the LED Indicators section for LED light meaning When all connections are all set and LED lights all show in normal the installation is complete MICROSENS Troubles shooting m Verify that you are using the right power cord adapter DC 12 48V please don t use the power adapter with DC output higher than 48V or it will burn this switch down Select the proper UTP cable to construct your network Please check that you are using the right cable Use unshielded twisted pair UTP or shield twisted pair STP cable for RJ 45 connections 1000 Category 3 4 or 5 cable for 10Mbps connections 1000 Category 5 cable for 100Mbps or 1000 Category 5e above cable for 1000Mbps connections Also be sure that the length of any twisted pair connection does not exceed 100 meters 328 feet Diagnosing LED Indicators the Switch can be easily monitored through panel indicators which describes common problems you may encounter and where you can find possible solutions to assist in identifying problems the power indicator does not light on when the power cord is plugged in you may have a problem with power cord Then check for loose power connections power losses o
10. te reverse steps above MICROSENS Hardware Installation In this paragraph we will describe how to install the 5 port 10 100 1000Base TX Industrial Switch and the installation points for the attention 8 5 Data collect server Human Management Interface Enterprise Switch Industrial Industrial Industrial Switch Switch Switch Field Management Programmable logic controller Ec b Device Server Field Automatic device Field Automatic device Field Automatic device Distribute I O control system Installation Steps 1 Unpacked the Industrial switch 2 Check the DIN Rail is screwed on the Industrial switch If the DIN Rail is not screwed on the Industrial switch Please refer to DIN Rail Mounting section for DIN Rail installation If you want to wall mount the Industrial switch then please refer to Wall Mount Plate Mounting section for wall mount plate installation 13 MICROSENS To hang the Industrial switch on the DIN Rail track or wall please refer to the Mounting Installation section Power on the Industrial switch How to wire the power please refer to the Wiring the Power Inputs section The power LED on the Industrial switch will light up Please refer to the LED Indicators section for meaning of LED lights Prepare the twisted pair straight through Category 5 cable for Ethernet connection Insert one side of Category 5e or above cables into the Industrial switch Etherne