1. Then type admin code to enter Setup mode Default admin code 123456 If you hear 2 beeps the code you have typed is wrong 2 Type 41 You hear one beep and the LED 6 indicator lights up the k d switches t cance ERNE RE 3 Swipe the RFID tag in front of the RFID reader You hear one beep the connection is successful Ifyou hear two beeps the RFID tag has already been connected oe COR MOJIOIO Press to exit Setup Mode To clear all registered RFID tags press any of the Arm amp or Home Mode keys on the keypad to unlock it and then type admin code 42 You hear one beep the RFID tags have been deleted from the keypad Usage The keypad can be used as a remote control Your user code or your admin code will be required before arming or disarming the system or switching to Home Mode or Mute Mode Arm the system Censer 1 Press Arm or Home Mode on the keypad to unlock it 2 Type your user rae admin code 6 3 Press the Arm key Ol The LED indicator blinks once the keypad beeps once and sends to the 6 control panel the signal to arm the system 9 When the alarm panel receives the signal the siren beeps once and the Arm indicator on the control panel lights up The alarm system is now armed Default admin code 123456 default user code 1234 Disarming the system with the keypad 1 Press Arm or Home Mode on the keypad to unl
2. before each operation 19 Solution Register the keypad in the control panel by following the instructions in this manual Install the keypad and the control panel closer to each other It is recommended to buy arepeater to extend the transmission distance Register the RFID tag in the control panel according to the instructions in this manual Enter Setup mode and activate the function Enable Disable deactivation by RFID tag Press Arm or Home Mode then before disarming Refer to instructions in this manual Refer to instructions in this manual Type your user code or admin code before the operation Care and Maintenance For a safer use and a longer lifetime of the ES K1A we recommend you to follow the instructions listed below Usage notices General instructions This keypad must be registered in the control panel of your eTIGER alarm system before being used for the first time The power supply of this keypad may impact the transmission distance of the wireless signal This keypad is powered by 3 x AAA batteries This keypad is compatible with eTIGER Secual alarm systems Remove the battery strip before using for the first time To avoid disturbing your neighborhood do not press the SOS key unless necessary Check your keypad on a regular basis to make sure the system works properly in case of emergency This keypad is neither waterproof nor moisture proof Install it in a shady
3. sound will be off too Turn keyboard clicks on 1 Enter Setup mode 2 Type 3510 3 You hear one beep the setup is successful OW Turn keyboard clicks off 1 Enter Setup mode 2 Type 3511 Remark Default setting keyboard clicks are on 15 Enable Disable deactivation by RFID tag Enable deactivation of the system by RFID tag 1 Enter Setup mode 2 Type 3610 3 You hear one beep the setup is successful Disable deactivation of the system by RFID tag 1 Enter Setup mode 2 Type 3611 3 You hear one beep the setup is successful Remark Default setting deactivation of the system by RFID tag is enabled 16 Change user code The user code may be required to interact with the control panel arm or disarm the system or switch to Home Mode We recommend you to change the user code before using the keypad for the first time 1 Enter Setup mode 2 Type 38 new user code 3 You hear one beep the setup is successful 010 Remark The user code must consist of 4 digits Default user code is 1234 Change admin code The admin code may be required to change the settings and interact with the control panel arm or disarm the system or switch to Home Mode We recommend you to change the admin code before using the keypad for the first time 1 Enter Setup mode 2 Type 39 new user code 3 You hear one beep the setup is successful OW Remark The a
4. C ertiGer wild instinct of Technology Censer wO 6 e FJ 0 0 le 0 9 ES K1A Wireless Keypad www etiger com af Foreword Thank you for purchasing the ES K1A The ES K1A is a keypad that enables you to arm and disarm your alarm system or arm it in Home Mode Before entering your home all you need to do is to type your passcode and press the Disarm button U or swipe the RFID tag sold separately in front of the RFID reader to disarm the system Box Content Keypad x 1 AAA 1 5V batteries x 3 Screws x 4 Documentation Appearance RFID reader e eTIGER LED indicator _ os ume acres NE Home Mode 7 8 9 Home A TF eH sos key RFID tag 125 KHz sold separately The keypad supports up to 50 RFID tags Refer to the instructions on page 9 of this manual to learn how to register an RFID tag in the keypad RFID Tag Rear cover Battery compartment EE 0 een Tamper switch o o Preparation Before Use How to turn the ES K1A on The ES K1A is powered by 3 AAA batteries Before using for the first time remove the battery strip Unscrew and open the case Insert the batteries according to the positive and negative signs Close the case and screw it back Remark Becaus
5. cool and dry place The case of this keypad is made of ABS plastic Please keep it away from strong light to ensure longer lifetime Limitations This keypad is not explosion proof Keep it away from fire and flame sources Install this keypad away from objects that produce heat or electromagnetic fields such as heaters air conditioners microwave ovens etc Recycling instructions Dispose of the keypad according to local regulations Do not dismantle the product if you are not a professional technician 20 Maintenance Clean your keypad with a dry soft cloth or tissue If there is dirt on your keypad wipe the surface with a soft cloth and diluted detergent and then wipe again with a dry cloth Standards X This product bears the selective sorting symbol for waste electrical and electronic equipment WEEE This means that this product must be handled pursuant to European Directive 2002 96 EC in order to be recycled or dismantled to minimize its impact on the environment For further information please contact your local or regional authorities Electronic products not included in the selective sorting process are potentially dangerous for the environment and human health due to the presence of hazardous substances cE In compliance with European laws This product is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC RoHs This product was designed and manufactured in compl
6. de 123456 Remark Correct operation 1 beep and the LED light blinks once Wrong operation 2 beeps and LED light blinks twice Register the ES K1A in the control panel Make sure the control panel is in Connection mode refer to the user manual ofyour eTIGER alarm system Press Arm or Home Mode on the keypad to unlock it Type your user code or admin code on the keypad and then press any ofthe Arm Disarm or Home Mode keys Your hear short beeps the registration has succeeded Default admin code 123456 Default user code 1234 The control panel of your alarm system can be controlled from distance on the keypad once the latter has been registered in the control panel Connect the ES K1A to an eTIGER siren The ES K1A can be connected to an eTIGER indoor or outdoor siren which enables you to trigger the siren by pressing the SOS key on your keypad To connect the keypad to an eTIGER siren set the wireless siren to Connection Mode refer to the manual of your eTIGER siren if necessary Press the Arm or Home Mode key on the keypad to switch to Normal Mode Then type your admin code or user code and press any of the Arm Disarm or Home Mode keys on the keypad For more information on sirens and accessories compatible with eTIGER security systems visit our website etiger com Register an RFID tag in the ES K1A 1 Press Arm or Home Mode on the keypad to unlock it
7. dmin code must consist of 6 digits Default admin code is 123456 17 Reset After having reset the keypad the user code the admin code and other settings will be restored to default settings The RFID tags that have been registered will not be deleted from the keypad 1 Enter Setup mode 2 Type 987654321 3 You hear one beep the setup is successful 9 6101010 FAQ Problem Cause Solution Low battery Change the battery The batteries positive Remove and insert the batteries No response from and negative terminals again according to the instructions the keypad are reversed in this manual The keypad is locked Press Arm or Home Mode on the keypad to unlock it The keypad cannot No response from the Make sure the alarm panel is on be registered to the alarm panel _ control panel Make sure the alarm panel is in Connection mode 18 Problem No response from the control panel when operating on the keypad Cannot disarm the system by RFID tag The keypad cannot be set up The keypad cannot arm disarm or switch to Home Mode Cause The keypad is not registered in the control panel The keypad is installed too far from the control panel The RFID tags have not been registered in the keypad The RFID reader is disabled The keypad is locked The keypad is not unlocked The keypad does not switch to Setup mode Your user code or admin code has not been typed
8. e of the tamper switch opening the rear cover of the keypad when the latter is on triggers the alarm In such case stop the alarm by disarming the system as explained in page 10 of this manual Installation 1 Unscrew the case and open it 2 Screw the rear cover to a door frame or to a wall 3 Fasten the front cover of the keypad to the rear cover and screw them together Remark Because of the tamper switch opening the rear cover of the keypad when the latter is on triggers the alarm In such case stop the alarm by disarming the system as explained in page 10 of this manual Setup The ES K1A operates under 4 modes Normal mode The LED indicator blinks once every 5 seconds Sleep mode Under Normal mode the keypad switches to Sleep mode if no operation is made for 35 seconds Press the Arm or Home Mode keys to exit Sleep mode When the keypad is in Sleep mode the LED indicator is off RFID Reader mode Under Normal mode press on the keypad to activate the RFID reader for 10 seconds the LED indicator turns on After 10 seconds the LED light turns off as the RFID reader turns off automatically Setup mode To enter Setup mode switch to Normal mode and then enter your admin code on the keypad The LED indicator blinks once every second Press to exit the Setup mode and switch to the Normal mode After 30 seconds without operation the keypad goes back to the Normal mode Default admin co
9. iance with Directive 2002 95 EC of the European Parliament and of the Council on the restriction of use of certain hazardous substances in electrical and electronic equipment ROHS Directive RoHS and is deemed to comply with the maximum concentration values set by the European Technical Adaptation Committee TAC Manufactured in China Images illustrations and text are non contractual ETIGER and the ETIGER logo are registered trademarks and the property of ETIGER Copyright 2015 ETIGER All rights reserved 21 ES K1 A UM EN20150303 2 1 W www etiger com eu support service etiger com
10. ock it 2 Type your user code or admin code 9 3 Press the Disarm button the LED indicator 0 blinks once the keypad beeps once and sends to the control panel the signal to disarm the system When the control panel receives the signal the siren beeps twice and the Disarm indicator lights up the alarm system is now disarmed 10 Disarming by RFID tag 1 Press Arm or Home Mode amp on the keypad to unlock it 2 Press to activate the RFID reader for 10 seconds 3 Within the next 10 seconds swipe the RFID tag in front of the reader to disarm the system The RFID reader turns off when a RFID tag is swiped in front of it when the key is pressed again on the keypad or after 10 seconds without operation Home Mode 1 Press Arm or Home Mode on the keypad to unlock it 2 Type your user code or admin code 3 Press the key the LED indicator blinks once the keypad beeps once and sends the signal to the control panel to switch to Home Mode When the alarm panel receives the signal the siren beeps once and the Home Mode indicator lights up the alarm system is now in Home Mode All the sensors in regular zones are armed except those in the Home Mode zone The sensors in the Home Mode zone are disarmed so that users can move inside their home For more information on the setup of zones please refer to the user manual of your eTIGER alarm system 11 Emergency call Refer to
11. the instructions page 14 ofthis manual for more information on how to lock unlock the SOS button With SOS button unlocked 6 1 Press Arm or Home Mode on the keypad 9 to unlock it 2 Press SOS 3 The LED indicator blinks once the keypad beeps once and the alarm is triggered immediately With SOS button locked 1 Press Arm or Home Mode on the keypad to unlock it 2 Type your user code or admin code 3 Press SOS to trigger the alarm immediately Low battery indication When the battery level is low the LED indicator blinks 3 times every 5 seconds In such case please change the batteries 12 Settings Enter Setup mode Press Arm or Home Mode on the keypad to unlock it Type admin code to enter Setup mode Default admin code 123456 Under setup mode ifno operation is made for 30 seconds the keypad will exit the setup mode automatically The setup mode can also be exited by pressing Exit delay Detectors start detecting potential intrusions immediately after the system has been armed To prevent alarms when you leave your house an exit delay can be set up If you have set up an exit delay the control panel will receive the signal to arm the system when you press the Arm key on the keypad after the time set 1 Enter Setup mode 2 Type 33 delay time in seconds 3 You hear one beep the setup is successful To deactivate the Exit delay set 0 as delay
12. time Remark The time is set in seconds it can be set from 0 to 255 Default setting 0 13 Ifthe exit delay has been set the control panel will beep once every second after having pressed the Arm key The rhythm of the beeps will speed up during the last 15 seconds After the exit delay time has elapsed the control panel is armed If an exit delay has been set up for both the control panel and the keypad the actual delay time will be the combination of both exit delays This setting does not apply to the Home Mode Remark Only the Exit delay can be set on the keypad The Entry delay can be set on the control panel refer to the user manual of your eTIGER alarm system Lock Unlock the SOS button Lock the SOS button 1 Enter Setup mode 2 Type 3410 3 You hear one beep the setup is successful If the SOS button is locked you will need to press Arm or Home Mode to unlock the keypad to type your admin or user code then to press SOS to trigger the alarm FRE Unlock the SOS button 1 Enter Setup mode 2 Type 341 1 3 You hear one beep the setup is successful If the SOS button is unlocked the control panel will ring out immediately when you press Arm or Home Mode and then SOS ee SR Remark Default setting SOS button is locked 14 Keyboard clicks Keyboard clicks can be turned on or off If keyboard clicks are off the successful setup notification