Home

X-Stream VISION User Manual

image

Contents

1. New Component item 2 The component editor window opens Edit component Name omponent O Samples 1000 100 000 ms Primitive Primitives list Preview Sine Mj Amplitude mv 500 Period Samples 1000 Phase deg 0 Cancel You may select the component name and the number of samples The samples are converted into ms according to the selected sampling rate User Manual 45 MotionPro DAS 6 9 Insert primitives into a component From the component editor window select the primitive type and operation x Modify the primitive parameters Different primitive types have different parameters Click the Add to List button You may also Pe ON e Delete a primitive from the list e Reset the list e Move a primitive Up and Down in the list Edit component Name Component O Samples 100 000 ms Primitive 7 Primitives list iais Delete x Square v Sire Add to list Amplitude mW 500 Period Samples 530 Phase deg D Amplitude mv 500 Period Samples 1000 Duty Cycle 50 Phase deg 0 46 User Manual MotionPro DAS 6 10 Edit a component 1 From the Edit menu select the Edit Component item 2 If the waveform has a single component the edit component window will appear otherwise a new window will ask you to select which component to edit 3 Select the component from the list and click OK 4 Refer to the previous top
2. The Open data acquisition device dialog box allows the user to open and configure a data acquisition device If more than one device is attached to the computer system the user may select from a list For each device the user may select the analog subsystems that will be open Once the dialog box completes the initialization procedure for the device the application window for the active device is open as shown below User Manual 15 MotionPro DAS MotionPro Data Acquisition DA Device SN 0006189036 W File Process Device view Tools Window Help e REMH 40 Run Control Run Stop Single Vertical Volts div to my v Channel i v Offset 0 0 Y Horizontal msfdiv 100 ms v Display Oto 1000 ms CSS p Input Trigger Source None Channel Level mv Input Channels E 23 567 s 910 11 121314 1916 Burst Size ms 1000 Sync Source Internal Sync Rate 10KHz vw Along with the usual top bar menu structure the application also includes a docked dialog bar on the right side and a docked dialog bar on the bottom side In the right bar the main operational controls of the data acquisition are grouped by function Run control for acquisition waveform generation vertical and horizontal configuration for data display input trigger for the configuration of the ADC trigger The function of these controls is in great part also accessible from the top menu bar In the bottom bar four bu
3. 3 1 INTRODUCTION TO THE MOTIONPRO DATA ACQUISITION SYSTEM 7 3 2 SYSTEM COMPONENTS cseccccceseeeececeeceecauesceesaneneeesaeeneeeeceaaeeeensugeeeessaeseetaneess 9 3 3 NOTE ON OPERATING SYSTEMS cccccccesecceccesseeceseeseeteceeneececeeneetaneaeeesaneeeeeaeeaes 9 3 4 SOFTWARE DEVELOPMENT KIT ccccececcceceeseecaceeceecaeeceesaneaceeeseaeeeecsaeeeensaes 10 4 INSTALLING THE MOTIONPRO DAG cccccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 11 4 1 MINIMUM COMPUTER REQUIREMENTS cccccsseceecaceececcesseeeeeeeseeeeteaeeterenseeeees 11 4 2 PACKAGE CONTENTS 0ccccccscscescccceeccencusesceteuseseetensesensenuseeneesesestensusessencueevente 11 4 3 SOFTWARE INSTALLATION ccccccsecceeceseceeeceneeceecaeenceesaeeneeeeeeeaeeeeseaaeeeeteaeeeenenes 12 4 4 HARDWARE INSTALLATION ccccccccescecceeescceeceeseeeecessceeeceageeeecenseesetenseeeetanseeeets 13 4 5 DATA ACQUISITION BACK PANEL cccccesecceeceseeceecaseceeeaeeneeeeeeaaeeeetenseeeetenseeeees 14 5 DATA ACQUISITION STAND ALONE PROGRAM ccccsssseseeeeeeeeees 15 5 1 OPEN DATA ACQUISITION DEVICE 00cccccceeeseececeeceecaceeceesaneaceeeceaneeeensaaeeeensaes 15 5 2 DATA ACQUISITION MENU STRUCTURE occccocccnccconccnncnonccnnnnoncnnnnnnnronnnnononennonnnnenos 17 5 3 FILE MEN soccer natant dese Aone leiden die eta 18 5 3 1 Open adata file ssa taa en ea 19 5 3 2 Save acquired data ccoo cient eines aladdin elie REU ie 20 5 4
4. Windows 2000 XP Yes 5 V DC at 2 A maximum 0 to 55 C 95 53
5. 0 2 my For each channel the minimum the maximum the average and the standard deviation values are displayed 32 User Manual MotionPro DAS 5 6 2 Cursors You may measure waveform data using cursors Cursors are horizontal and vertical markers that indicate X axis values time and Y axis values voltage on a selected waveform source The position of the cursors can be moved by dragging the triangular handles on the screen See the picture below The cursors are activated by clicking the corresponding buttons in the horizontal bottom bar it 266 ms e 450 ms DX 184 ms F 5 4 Hz 14my 23 24 mv DY 10 my In the same bar the displayed values are DX X X1 the frequency and DY Y Y1 Cursors are not always limited to the visible display If you set a cursor then pan and zoom the waveform until the cursor is off screen its value will not be changed and if you pan the waveform back again it will have the cursor in its original position User Manual 33 MotionPro DAS 5 7 TOOLS menu 5 7 1 Waveform Editor 1 From the Tools menu select Waveform Editor 2 The waveform editor is launched please refer to the chapter 6 5 7 2 Options 1 From the Tools menu select Options 2 Select the colors and click OK Options Background color Grid Color Channels color Channel 1 5 7 3 Language selection 1 From the Tools menu select La
6. group at the top of the Docked Dialog menu has data acquisition control functions including the following 1 Run Stop start and stop continuous acquisition 2 Single run a single burst Run Control o E Run Stop Single 24 User Manual MotionPro DAS 5 5 2 Vertical controls Use the vertical controls group in the docked vertical bar to configure the data display vertical parameters Vertical ane Volts div 2 Y v Channel _ 0 vw gt 0 0 Y Offset DY 10 0 Y Volts div the control sets the vertical resolution in volts division Vertical displacement Offset the user may vertically scroll each input signal independently If more than one signal is displayed select the signal from the channel list and scroll the vertical slider User Manual 25 MotionPro DAS 5 5 3 Horizontal controls Use the horizontal controls group in the docked vertical bar to configure the data display horizontal parameters Horizontal msfdiv 50 ms v Display O to 500 ms 4 gt ms div the control sets the horizontal resolution in ms division The option Fit to window automatically sets a value that fits the signal length in the current window Display scroll the blue bar to display different parts of your acquisition The bar is automatically resized if the length of the acquisition cannot fit in the screen 26 User Manual MotionPro DAS 5 5 4 Input trigger The acquisition of
7. 2 What s new User Manual 51 MotionPro DAS 7 Appendix A Product Specifications 7 1 Specifications Analog inputs Number of inputs Resolution Programmable gains Ranges Single Channel A D throughput Multi channel A D throughput A D conversion time Bipolar input range Output coding Maximum input voltage power off Maximum input voltage power on Input impedance channel off Input impedance channel on Bias current Non linearity Analog outputs Number of DACs Resolution Throughput Output range Data coding Output current Output impedance Capacitive driver capability Protection against Non linearity External A D and D A Triggers Internal trigger source External trigger source 52 16 16 bit 1X 2X 4X 8X 10 V 5 V 2 5 V 1 25 V 500 kS s 500 kS s 0 05 2 us 10 V Offset binary 35 V 20 V 100 MO 10 pf 100 MQ 100 pf 20 nA lt 1 2 LSB 4 16 bit 500 kS s 10 V Offset binary 5 mA 0 1 O 0 004 uF Short circuit to analog ground 1 LSB Software initiated Software selected User Manual MotionPro DAS Input type Logic Input termination Logic high input voltage Logic low input voltage Minimum pulse width Miscellaneous Interface Operating systems Plug n play Power requirements Operating temperature range Relative humidity User Manual Edge sensitive TTL 2 2 kQ pull up to 3 3 V 20V 0 8 V 25 ns USB 2 0
8. ENU STRUCTURE scccccesscceecesseecetenseceetenseeeeeaneees 39 MotionPro DAS 6 3 FICE MENU ws cites Statin ais he he a lee ee 40 6 4 CREATE A NEW WAVEFORM cccccccceceseseceeeecceeeeseeceeceeeeeesaeaeaeseceeeesaeauaeaseeseeeesaees 41 6 5 OPEN A WAVEFORM FILE aikoa ee i a e aaa iaaa A EA a E aiaa 42 6 6 SAVE A WAVEFORM caraio dido nan aci sad a dd 43 6 7 EDIT MENUS 2205 0 205 528 e oie eel Tons CANOA TA PE SOL Eua OR SUS Oo CRIS Sta E 44 6 8 ADD COMPONENTS TO A WAVEFORM occcccccccccccoconononnnnnonononinnnnonnnnnnononinnnnononenononos 45 6 9 INSERT PRIMITIVES INTO A COMPONENT 0sseccceeccecseseecceeeceeceeaeaeeuceceeeeseasaaenes 46 6 10 EDITA COMPONENT sicsieterds otic cheese p ae e dE Aces fera a duas couche weeded dada toda 47 6 11 DELETE A COMPONENT isento ass ain ta seres iaa 48 GAZE Id 49 6 13 TOOLS MENU szecscheresscenecs tala 50 6 13 1 OPIO Sit AA A LA A ee 50 6 13 2 Language iia ltd E E paca SD aan ta aoe i 50 6 14 HELP MENU cia iia 51 7 APPENDIX A PRODUCT SPECIFICATIONS 52 7 1 SPECIFICATIONS ieee eviews otiarednvesnaieekiteasg A ri ea 52 4 User Manual MotionPro DAS 1 Precautions 1 1 Cables Ensure that all cable connections are properly secured and that there is not excessive strain on the cabling User Manual 5 MotionPro DAS 2 Warranty IDT Inc provides warrants to the original purchaser that from the date of delivery th
9. MotionPro DAS User Manual For Windows MotionPro DAS Software Release 1 03 Document Revision April 2008 Products Information http Awww idtvision com North America 1202 E Park Ave TALLAHASSE FL 32301 United States of America P 1 850 222 5939 F 1 850 222 4591 llourenco idtvision com Europe via Pennella 94 1 38057 Pergine Valsugana TN Italy P 39 0461 532112 F 39 0461 532104 pgallorosso idtvision com Eekhoornstraat 22 B 3920 Lommel Belgium P 32 11 551065 F 32 11 554766 amarinelli idtvision com Copyright Integrated Design Tools Inc The information in this manual is for information purposes only and is subject to change without notice Integrated Design Tools Inc makes no warranty of any kind with regards to the information contained in this manual including but not limited to implied warranties of merchantability and fitness for a particular purpose Integrated Design Tools Inc shall not be liable for errors contained herein nor for incidental or consequential damages from the furnishing of this information No part of this manual may be copied reproduced recorded transmitted or translated without the express written permission of Integrated Design Tools Inc 2 User Manual MotionPro DAS User Manual Table of Contents ds PRECAUTIONS aa a as 5 1 1 CABLES taa ada 5 2 WARRANTY a a a a aaa 6 3 SYSTEM OVERVIEW squares en iain 7
10. PROCESS MENU una Iara ara Dina Sele avers da de da dedi na aaa 21 5 4 1 Filters and Math operations erre nn nn cnnnnnnnnannnnnnnnnnnnns 22 5 4 2 FFT and Power Spectrum erre aaa aaararenenana nana naaaarenenna 23 5 5 DEVICE MENU cocida 24 5 9 1 1 RUN CONTO id ccrten ee ae ca era ti 24 5 5 2 Metical Controls 22 0 2 2 22nh nado A a RAS se tae aerate 25 5 5 9 Horizontal COmtrOlS ess oi taaan 26 O94 NDOGO caca 27 5 5 5 PUE Channels i455 A T dd 28 5 5 6 Configuring input channels nono OAE rca rra 29 5D Output channels ais cs sentado a aa ae ADIAR aaa 30 5 6 VIEW MENU uti dde 32 5 6 1 Average and Standard Deviation erties ee eeneeeeeeieeeeesieeeereenieeeeee 32 010 20 gt ACUISOLS ada tienes famed alias parda aon te eet si cado so atcha tt haan RARO Lada nan 33 5 7 TOOLS MENU scsivendedestvevedstle decades A 34 5 7 1 Waveform Editof caducidad lata tarro ra au EL Duetos sado ad dadas 34 5 7 2 OPTIONS e m aee RO DER SOR OR UU e RR DAR EUDES ED RV RT 34 Sra Language SClEChOn arpaan aaa ta WA cere o dana AAA Ea Noam da dai Ea eld 34 5 8 WINDOW MENU oocccccccccncnoncncononnnnnnnnnocononononononononinnnnonnnnnnnnnnnnnnnnnnnnnonananeninneninnns 35 5 9 HELP MENU A eck a ke ise cafe eee Ae eo dE 35 6 WAVEFORM EDITOR ae aaesareagrasareaquasoranquenoraneuanaranquadonandnadonaagnadodandes 36 6 1 OVERVIEW sida tds RSA GAS O Na ances a OIC CANAS 36 6 2 THE WAVEFORM EDITOR M
11. an existing waveform file option and click OK 2 Browse for the waveform file to open 3 Click the Open button Open waveform file Data a 2comp2prim wfm a logandexp wFm My Recent ia modulated_sine w m Documents 22 ModulatedSine fm a noisysine2 wfm a noisysine wfm sa sine fm My Network Files of type Waveform Files wm 42 User Manual MotionPro DAS 6 6 Save a waveform 1 Tosave a waveform file from the File menu select the Save waveform 2 Type the file name and click OK Save waveform file Save in D My Recent Documents My Network User Manual B Data tem a 2comp2prim wfm a logandexp wfm a modulated_sine w m ra ModulatedSine wfm a ModulatedSinePlusSine wfm a noisysine2 wfm a noisysine wfm a sine wfm File name Save as type Waveform Files wfm Save Cancel 43 MotionPro DAS 6 7 Edit Menu 44 The edit menu contains the following options e Add a new component to the waveform e Edit one of the components of the waveform e Delete one of the components of the waveform e Edit the waveform sampling rate view Tools Help nn New Component A Edit Component gt lt Delete Component 2 Edit Rate User Manual MotionPro DAS 6 8 Add components to a waveform 1 From the Edit menu select the
12. art Guide User Manual 11 MotionPro DAS A A 4 3 Software Installation 12 Windows 2000 XP Before installing the software make sure that the computer has Windows 2000 or Windows XP installed as operating system 1 Log into Windows with a username and password that has ADMINISTRATIVE PRIVILEGES 2 Insert the Data Acquisition CD in the CD drive If the computer is configured to AUTORUN the installer will run automatically If not click on the Windows Start button Select Run from the menu Use the Browse button to locate the SETUP EXE file on the Data Acquisition CD and click the OK button Select the Install option and follow the on screen instructions EXIT when the installation is complete and restart your computer User Manual MotionPro DAS 4 4 Hardware Installation A 5 VDC 6 Amp supplies the device with the necessary power This power supply unit is included with the system package All communication and data transfer with the host computer is done via the USB 2 interface This interface requires a single cable which is also supplied with the camera package qu Windows 2000 XP 4 1 Connect the device to the power source 2 Connect the USB 2 0 cable to an available USB 2 0 port on your computer 3 Connect the other end of the USB 2 0 cable to the device and wait a few seconds for the device to initialize it self 4 Follow the on screen instructions Click on the YES or Continue Anyway bu
13. ata Acquisition stand alone application SDK modules with example source code in MSVC ActiveX Control Plug in for LabVIEW TM Plug in for MATLABTM The SDK modules provide an API interface to develop applications to operate the device and access all the capabilities using a programming language such as C and Java A C C header file is included in the SDK XsdaAPI h file in the Include sub directory For a more detailed description of the SDK please refer to the MotionPro DAS SDK Reference User Manual MotionPro DAS 4 Installing the MotionPro DAS This section specifies the minimum recommended computer requirements and gives the procedures needed to install the device I O Cable and software 4 1 Minimum computer requirements PC Operating System Windows 2000 Windows XP Processor Pentium III or equivalent with 500 MHz processor RAM 256 MB USB2 Port high speed USB port that is NOT shared with other devices Hard Drive 40GB or greater hard drive recommended Additional equipment CDR drive recommended 4 2 Package contents Before beginning the installation process check that the following items are present in the MotionPro DAS package If you are missing any of the items listed below please contact IDT Inc or your sales representative Data Acquisition module I O USB 2 0 Cable CD ROM of Data Acquisition software and documentation Data Acquisition Quick St
14. data is started by a trigger that can be configured by the user Input Trigger Source Channel v Channel Chn 1 v Level mv 1000 v Source the trigger source may be software none channel one of the input channels themselves or external edge high or edge low Channel if the trigger source is channel use this control to select it The option is grayed out if the source is not channel Level use this option to select the trigger level value The option is grayed out if the source is not channel User Manual 27 MotionPro DAS 5 5 5 Input channels Use the input channels controls to configure the acquisition channels Input Channels RE 6 7 8 9 10 11 12 13 14 15 16 Burst Size ms 200 Sync Source Internal Y Sync Rate 5 KHz v Channels display the rectangle shows the open channels highlighted by a blue rectangle Click on the numbers to configure the channels Burst size the size of the acquisition in ms Sync source the synchronization source internal or external Sync rate the sampling rate 28 User Manual MotionPro DAS 5 5 6 Configuring input channels If the input channels rectangle is clicked the dialog box below appears Analog Input Channels HEHEHE EE ESSES ESSES ES HEHEHE EE E E es es a Channel Configuration V Enable Color E Gain 1x v Bkg Color E Grid color i v Channels button click on the button of the channel that you want to con
15. e hardware components of the MotionPro Data Acquisition System the Product will be in good working condition for a period of one 1 year on all parts Should any of the components of this Product fail to be in good working order at any time during this warranty period IDT Inc will either repair or replace those components at its factory at no additional cost This warranty does not include service to repair damage to the Product caused by accident disaster misuse abuse or non IDT modification of the Product All service shipments to IDT must be sent pre paid Warranty service may be obtained by contacting IDT in writing during the warranty period Integrated Design Tools Inc 1804 Miccosukee Commons suite 208 TALLAHASSE FL 32308 USA Attn Service Department T 850 222 5939 F 850 222 4591 Note It is requested that the product be returned to INTEGRATED DESIGN TOOLS Incorporated for warranty service in its original packaging 6 User Manual MotionPro DAS 3 System Overview 3 1 Introduction to the MotionPro Data Acquisition System The MotionPro Data Acquisition System DAS is a multifunction data acquisition module for the USB 2 0 bus The module can perform simultaneous operation of analog input and analog output The key hardware functions are listed below 16 analog input channels with programmable gains 4 analog output channels for waveform generation Internal or external clock source Trigge
16. figure Enable select this option to enable disable the channel A disabled channel is not sampled Color select the channel display color Gain select the channel gain 1X 2X 4X 8X Background color select the main window background color Grid color select the data grid color User Manual 29 MotionPro DAS 5 5 7 Output channels Click the output button on the docked vertical bar and the output channels dialog box will appear Output parameters are independent from the input but they are activated by the play button on the vertical toolbar ae Analog Output Channels General Period ms Rate Sampling Src 1000 1 00 Hz Internal v Sampling Rate Trigger Source 10 KHz v Software v Channel Configuration Current Channel Channel 2 Enable Waveform Sine v Amp mv Offset my Phase deg 10 0 Y 10 0 Y 360 Time base ms Auto Period the output signal period in ms Sync source the output sync source internal or external Sync rate the output rate Trigger source the start trigger source may be software or external edge high or edge low Four analog output channels are available Each channel may be independently configured Current Channel select the channel that will be configured Enable select this option to enable disable the channel A disabled channel is not sent to the output DAC Waveform select the waveform shape square sine triangle saw tooth or File A
17. ic to add delete and edit the primitives in the component Edit component Select the component and click OK Component 0 O Component 1 User Manual 47 MotionPro DAS 6 11 Delete a component 1 From the Edit menu select the Delete component item 2 If the waveform has a single component the component will be deleted otherwise a new window will ask you to select which component to delete 3 Select the component from the list and click OK Delete component Select the component and click OK Component 1 48 User Manual MotionPro DAS 6 12 View Menu Use the View menu to show or hide the main toolbar and the status bar Tools Help Toolbar Status Bar User Manual 49 MotionPro DAS 6 13 Tools Menu 6 13 1 Options 1 From the Tools menu select the Options item 2 Change the background grid and signal colors then click OK Options Background color NH v Grid Color E Y Signal Color L Y 6 13 2 Language 1 From the Tools menu select Language 2 Select the language from the list and click OK Language tod Select the language from the list below 50 User Manual MotionPro DAS 6 14 Help Menu This menu contains support options and information including e mail tech support and software and manual updates Help Contents a Web Site 2 IDT Home page f about 2 Technical Support
18. ignal integrity and protect your computer 8 User Manual MotionPro DAS 3 2 System components The MotionPro Data Acquisition System components are listed below Data Acquisition System module The MotionPro DAS module provides 16 analog inputs 4 analog outputs and 16 digital I O with internal or external clock source and triggers Digital Interface The USB 2 0 480 Mb sec cable provides data and control signals to and from the module It connects the module to any USB 2 0 port on your personal computer or laptop Power Source The power supply provides external power to the device 5 V Data Acquisition Software and SDK it operates in Windows 2000 or Windows XP operating systems It plugs into LabVIEW and MATLAB and provides an SDK for customizable application development 3 3 Note on operating systems The MotionPro Data Acquisition System is supported in the following operating systems Windows 2000 Windows XP and Windows Vista User Manual 9 MotionPro DAS 3 4 Software Development Kit 10 Upon the installation of the MotionPro DAS SDK several options are available to the user These options are easily accessed via the Program menu under the Windows Start button The programs and associated files are organized under the IDT XsDA folder This folder includes the example programs and the associated documentation The software components included in the MotionPro DAS Software Development Kit are D
19. l operations Negative Invert Square and Square Root Low Pass Filter Filter Kernel Frequency Response Parameters Frequency Hz 100 Kernel Size 128 windowing Blackman The filter dialog box shows the kernel and the Frequency response of the selected filter The user may select the frequencies one value for low pass and high pass filters two values for band pass and band stop filters the kernel size and the windowing type rectangle Bartlett Blackman Hamming and Hann If the filters or the mathematical operations are activated the operations list in the horizontal bar is filled with those operations The user may e Select the items in the list and activate the single operation e Reset the list and delete the operations 22 User Manual MotionPro DAS 5 4 2 FFT and Power Spectrum If the FFT option is selected the Fast Fourier Transform window is displayed The user may select the channel to display the FFT and the power spectrum Channel 1 w FFT Channel 1 iPower Spectrum V User Manual 23 MotionPro DAS 5 5 DEVICE Menu The Device Menu on the main toolbar offers an alternative to using the buttons provided by the Docked Dialog menu including the following functions 1 Run Stop 2 Single 3 Input channels 4 Output channels view Tools Window RunjStop J Single 22 Input Channels 53 Output Channels 5 5 1 Run Control The Run Control
20. le gt Save Data 5 Select the desired folder 6 Type the file name select the file format from the Save as type control Save Acquisition Data Data a a lum 2 b lym My Recent 22 c lvm Documents E Desktop My Documents My Computer File name test My Network Save as type LabVIEW Measurement File Ivm Upon the installation of the application the user may save data in the formats listed below e ASCII File TXT e Binary File DAT e Tecplot File PLT e LabVIEW Measurement File LVM e Excel XML spreadsheet File XML The values saved in a data file may be used as sources to generate output signals For further information refer to the output channels paragraph 20 User Manual MotionPro DAS 5 4 PROCESS Menu The Process menu contains the following options e Apply filters and remove average from the signals e Apply mathematical operations to the signals e Show Hide the FFT Power Spectrum window ocess Device View Tools Window Help Low Pass Filter High Pass Filter Band Pass Filter La EFT Band Stop Filter BED Remove Average Negative Inverse Square Square Root User Manual 21 MotionPro DAS 5 4 1 Filters and Math operations Filter operations low pass filter high pass filter Band Pass filter Band Stop filter or Remove average Mathematica
21. mplitude Offset Phase configure the waveform parameters square sine triangle saw tooth File if the waveform type is file the output channel generates a waveform read from a WFM file WFM files are generated and edited by the Waveform Editor For further information please refer to the chapter 6 30 User Manual MotionPro DAS ne Analog Output Channels General Period ms Rate Sampling Src 1000 1 00 Hz Internal v Sampling Rate Trigger Source 10 KHz v Software v Channel Configuration Current Channel Channel 1 Enable Waveform File Waveform File ModulatedSine wrm Rate 10 kHz Samples 10000 Time 1 000 s Browse Time base ms Auto The signals are shown in the black window The user may select the Time Base period in us Ifthe Auto option is selected the application shows four waveform periods User Manual 31 MotionPro DAS 5 6 View Menu Use the View menu to activate the vertical X1 and X2 and the horizontal Y1 and Y2 cursors Use the View menu to select the toolbar options EE tools Window Help Cursors Toolbar Status Bar Device Bar Horizontal Bar Average Std Dev 5 6 1 Average and Standard Deviation The Average Std Dev option in the View menu activates the Average Standard Deviation window Average Standard Deviation Minimum Maximum Average Standard Dev 15 4mY 139mY 145mY 0 2 m 0 8 mY 1 1 mY 0 2 my
22. nguage 2 Select the language from the list and click OK Language tod Select the language From the list below Enoch 34 User Manual MotionPro DAS 5 8 WINDOW Menu If more than a window is open in the program use the window menu to cascade tile horizontally tile vertically or select one of the windows 5 9 HELP Menu This menu contains support options and information including e mail tech support and software and manual updates Contents Website 2 IDT Home page Devices info 2 Technical Support about e What s new User Manual 35 MotionPro DAS 6 Waveform Editor 6 1 Overview The waveform editor is a tool for the generation of analog waveforms files A waveform is made up of one or more components A component is made up of one or more primitives A primitive is the lowest level of a waveform A primitive can be anything from sine waves and triangle waves to pulses and noise Primitives of the component are added subtracted multiplied or divided into each other The examples below show different waveforms Example 1 The example below shows a waveform with one component The component has a single sine wave primitive 36 User Manual MotionPro DAS Example 2 The example below shows a waveform with two components Each component is made up of one primitive a sine and a square wave User Manual 37 MotionPro DAS E
23. r operations using a software command an analog threshold value or an external digital input value as the trigger event 500 V galvanic isolation barriers that prevents ground loops to maximize analog signal integrity and protect your computer Analog input subsystem 16 bit A D converter Throughput rate up to 500 kHz 16 single ended analog input channels Programmable gain of 1 2 4 or 8 provides input ranges of 10 5 2 5 and 1 25 V 1024 location channel gain list You can cycle through the channel gain list by using continuous scan mode or triggered scan mode The maximum sampling rate when using the channel gain list is 500 kHz Analog output subsystem 16 bit D A converter Output rate up to 500 k samples s Output range of 10 V User Manual 7 MotionPro DAS e The DACs are deglitched to prevent noise from interfering with the output signal e 1024 location output channel list You can cycle through the output channel list using continuous output mode or waveform mode For waveform generation mode you can simultaneously update all four DACs at 500 kHz per channel for continuous output mode you can simultaneously update all four DACs at 250 kHz per channel e External or internal clock source e Trigger operations using a software command an analog threshold value or an external digital input value as the trigger event e A 500 V galvanic isolation barrier that prevents ground loops to maximize analog s
24. tton when prompted by the Windows 2000 or XP Operating system to proceed with the installation User Manual 13 MotionPro DAS 4 5 Data Acquisition Back panel Power Connector USB 2 0 Connector GD PaO pa SR o BA o DR SR es ee Cm mC mC mC TO TO O O QOR p Analog Outputs Group Analog Inputs Group The BNC connectors are grouped in two groups Analog Inputs e AIN1 to AIN15 the analog input channels e Sync In the analog input external synchronization input e Trig In the analog input external event trigger input e Sync Out the analog input output signal Analog Outputs e AOUT1 to AOUTA the analog output signals e Sync In the analog output external synchronization input e Trig In the analog output external event trigger input 14 User Manual MotionPro DAS 5 Data Acquisition stand alone program This application allows the user to acquire data from the analog inputs save the data to the hard disk generate waveforms for the analog output channels open saved data files and display the signals apply filters and mathematical operations to the signals Upon execution the user can select to open a data acquisition window 5 1 Open data acquisition device Open Data Acquisition Device Select a device from the list below Then select the sub systems you want to open and click DK ID Serial Rey 2001 0004300009 A Sub systems Analog Input ADC Analog Output DAC
25. ttons allow the configuration of horizontal and vertical cursors for the computation of time frequency and voltage A list shows the filter and mathematical operations applied to the signals and a reset button allows the user to restore the original signal 16 User Manual MotionPro DAS 5 2 Data Acquisition Menu structure The Data Acquisition main menu contains the following options File Process Device View Tools Window Help User Manual 17 MotionPro DAS 5 3 FILE Menu 18 The file menu contains the following options Open the data acquisition window Open a data file Save acquired data on the hard disk and close windows Process Device View Tools Window Help gt Data File for Device Close lJ Save Data 1 Data0000 XLS Exit User Manual MotionPro DAS 5 3 1 Open a data file Each stored data file may be open and displayed 1 From the File menu select File gt Open gt Data File 2 Select the desired folder and the file name 3 Click Open Open Data File B Data Data0000 ASC Data0000 LvM My Recent Documents Datadooo PLT EM Dataoo0o xML File name DataD000 lt LS My Network Files of type All Data Files User Manual Cancel 19 MotionPro DAS 5 3 2 Save acquired data Each acquired sequence of data may be stored on the hard disk 4 Fromthe File menu select Fi
26. xample 3 The example below shows a waveform made up of one component The component is made up of 2 primitives The first primitive is a sine wave with the following properties e Amplitude 500 mV e Period 1000 Samples e Phase 0 The second primitive is a sine wave with an associated operation of multiplication This primitive has the following properties e Amplitude 5 mV e Period 50 Samples e Phase 0 38 User Manual MotionPro DAS 6 2 The waveform editor menu structure The Data Acquisition main menu contains the following options File Edit View Tools Help User Manual 39 MotionPro DAS 6 3 File Menu The file menu contains the following options e Create a new waveform e Open a waveform file e Save a waveform file E New Ctrl N ES Open Ctri O Ly Save Waveform CTRHS 1 chirp w rn 2 AM w m 3 sine_with_noise wm 40 User Manual MotionPro DAS 6 4 Create a new waveform Upon execution of the program the user can select to create a new waveform of open an existing waveform file Waveform Editor Startup Option Ho i O Open an existing waveform file e 1 Select the Create a new blank waveform option and click OK 2 Select the sampling rate and click OK Waveform Editor New waveform he Sampling rate ULC User Manual 41 MotionPro DAS 6 5 Open a waveform file 1 Upon execution of the program select the Open