Home

User Manual

image

Contents

1. OMNITEC DESIGN INC OmniAtre Portable Air Cleaner OA 1200PAC The OmniAire Portable Air Purification system purifies the air of airborne contaminants which could be biological chemical or particulates Connected to an isolation containment it can create small negative or positive pressure inside the containment The negative pressure will prevent contaminants from leak ing to the outside while positive pressure would prevent contaminants from outside to enter the contain ment All the air pulled from the containment or blown into the containment is purified through 99 99 0 3 micron HEPA filter and by high intensity UVGI lights Optional carbon filters can also be added to the machine to remove chemical odors www omnitecdesign com 2125 196th Street SW Suite 115 Lynnwood WA 98036 phone 425 774 3257 fax 425 774 4983 Page OmniAire PAC Instruction Manual 2008 PRODUCT SPECIFICATIONS Net weight with filters Dimensions LxWxH Operating Speeds Airflow Ratings Filtration Stages 99 99 0 3u HEPA Filter Metal Frame Medical Grade Cabinetry Closed End Rivet Construction Silicon Sealed Seams before Riveting Push Handle Polyurethane Casters Motor Horse Power Circuit Requirements Volts Hz Maximum Operating Amps Thermal Overload Protection Pressure Gauge Optional Accessories Intake Exhaust Manifold 10 diameter ring Hose clamp 10 diameter Flex hose 10 diameter Stainless Steel Quick Cla
2. 24 W X 29 D with wheels Optional Wheel Caster combination Page 7 OmniAire PAC Instruction Manual 2008
3. A E E E O BLACK 3 4 ny a BLUE HP Dz WHITE MOTOR Y u RED G HOUR BALLAST METER e UVGI LIGHT BLACK BERGE Fu UV Gl y BALLAST 1 Green TUBE 1 WHITE BLUE BLACK RED UV Gl BALLAST 2 GREEN TUBE 2 5 WHITE BALLAST M so le oo a or ea ea eos eos on CONTROL PANEL Onnitec Design E eZ Revision Revision Notes Date Eine PIERR Sh AUS UmniAire 1200 PAC Wiring Diagram 11 01 06 Lynnwood WA 98036 OmniAire PAC Instruction Manual Page 6 OmnniAire Portable Air Cleaners for First Response Shelters OmniAire PAC with HEPA and UVGI lights have been designed specifically to meet CDC requirements for clean filtered air in a medical environment Each air filtration system is equipped with a medical grade metal frame HEPA filter element that has been factory tested and certified as 99 99 efficient at 0 3 microns The OMNIAIRE PAC units can be paired with Environmental Containment Units to provide a comprehensive solution by providing a durable standardized prefabricated containment for quick emergency response Available Models OmniAire 800 PAC Compact size variable airflow 150 600 CFM Weight 75 lbs Size 36 H X 15 W X 15 D OmniAire 1200 PAC Versatile variable air flow for larger areas 200 1100 CFM Weight 115 lbs Size 40 H X 23 W X 20 D with wheels OmniAire 2000PAC Most powerful model with the largest range of variable airflow 200 1800 CFM Weight 125 lbs Size 40 H X
4. FF will indicate a light tube or ballast failure The UVGI tubes and bal lasts can be accessed by removing the HEPA filter Do not look directly into the UVGI lamps this could damage your eyesight Filter Replacement When replacing the HEPA filter proper care should be taken to wear a respirator in combination with the necessary PPE if contaminated with hazardous material The filter should be disposed of in an appropriate manner based on the con taminants it was exposed to The HEPA filter element see Figure 2 is held in place by metal tabs and can be accessed from the top of the unit To remove the element remove the metal grate unscrew the nuts on the tabs see Figure 3 and remove the tabs Lay the machine down on the handle and slide the element out Slide the new filter element into place with the gasket side of the HEPA filter facing the blower unit Make sure that the HEPA filter is seated well against the internal flange Place the machine back in the upright position replace the filter tabs and nuts and tighten to where the filter is flush with the mounting brackets Do not over tighten the bolts as this may crack the gasket When replacing the HEPA filter the primary filter should also be replaced The primary filter should be checked or replaced monthly To access the filter remove the manifold or gate and install a new pleated filter Observe the air flow arrow on the filter The HEPA filter efficiency of 99 99 will not degrad
5. e when the filter is loaded with dust but the air flow will be re duced The HEPA filter should be replaced when 1 The air flow from the machine is not sufficient to maintain the desired pressure in enclosure 2 The machine must run in high speed all the time to maintain the desired pressure which causes excessive noise 3 HEPA filter is more than 80 loaded NOTE The loading of the filter can be checked by switching the machine to HIGH speed after replacing the primary filter and reading the pressure gauge WC With all filters clean the gauge should indicate 1 2 to 1 3 WC A reading of 2 6 WC indicates the filter is 80 plugged and should be replaced Page 4 OmniAire PAC Instruction Manual 2008 Figure 1 View of the OmniAire PAC Manifold Installation Intake Manifold rests in a bottom i channel and is secured by four thumb screws Intake Manifold has replaced the intake screen Figure 2 HEPA Filter Installed in the Unit HEPA filter element mounting tab Figure 3 Close up of tabs for HEPA element HEPA Filter Primary Filter Element Element Intake Exhaust Manifold and Flex Duct Optional i er LAA AAA vr oo red Ae Aa at b i Hi eb he y tan a tee t Aed A TA TT TE Dis SHU Mil a hill a Ll y basen Page 5 OmniAire PAC Instruction Manual 2008 REFERENCE MATERIALS ee A
6. g the UVGI light on for another 10 minutes after the air flow is turned of to sterilize the inside of the compartment and the intake side of the HEPA filter The start and speed of the machine is controlled by the toggle switch HIGH SPEED CONTROL and the variable SPEED CONTROLLER knob To start the machine in the highest speed place the toggle switch in HIGH position To start the machine at reduced speed place the toggle switch in SPEED CONTROL position and turn the knob clockwise from OFF to start the blower The machine starts at HIGH SPEED and the speed is reduced by turning the knob clockwise to desired air flow The machine can be switched between the desired controlled speed setting and the highest speed at any time by toggle switch being moved between SPEED CONTROL and HIGH The toggle switch overrides the SPEED CONTROL LER knob setting and runs the blower at its highest speed This 1s also used as a quick check of HEPA filter loading and required filter change see Maintenance Maintenance Mechanical and Electrical The motor and blower do not require any maintenance when the machine is operated with the primary filter in place CAUTION In rare instances the blower wheel may become unbalanced If severe vibration is present stop op eration and investigate the cause The UVGI lights should last over 15 000 hours of operation There are two high intensity lights UVGI lights and two ballasts The LED indicating lamps turning O
7. mp Optional 10 Wheels combined with 3 Casters PARTS OA1200PAC HEPA Filtration System HEPA filter 99 99 0 3 micron Size 16 x 16 x 12 Primary filter 40 efficiency pleated filter Size 16 x 16 x 2 OPTIONAL FILTERS 115 1bs 22 x20 x40 Variable Speed Controller 200 to 1100 CFM 3 4 Standard Aluminum Yes Yes One 4 Swivel 3 3 4 hp 115 VAC 60 Hz 7 Amps Yes 0 3 W C OdorGuard 200 Carbon Pleated Filter Size 16 x 16 x 2 OdorGuard 600 Carbon Fiber Filter pad Size 16 x 16 x 2 OdorGuard 750 Plus Carbon Alumina Potassium permanganate filter pad Size 16 x 16 x 2 3067108 Page 2 CONFORMS TO UL STD 507 CERTIFIED TO CAN CSA STD C22 2 NO 113 M1984 OmniAire PAC Instruction Manual INSTRUCTIONS Unpacking Carefully check the unit for damage Remove the exhaust cover grill and check the HEPA filter It should be seated the filter should be flush with the mounting brackets and the brackets should be compressing the filter down The optional Intake Manifold see Figure 1 provides flex hose connection and holds the primary pleated filter in place Intake Manifold can be used on intake or exhaust side in place of the screen The manifold is secured by four thumb screws Operation While the OmniAire PAC machine can operate outside the containment it is recommended to protect it from the rain and dirty environment For the follo
8. sure As the doors to containment open the pressure will temporarily change and return to normal when the doors close The higher the speed the faster the room will return to desired pressure As the HEPA filter loads with dust the speed will have to be increased to reach the same airflow and to maintain the desired pressure inside the containment The PAC HEPA Filtration system must always operate with the HEPA filter in place to prevent contamination of the area and electrical overload of the motor Operating UV Germicidal Lights UVGI lights are installed in the compartment facing the HEPA filter The air passing by the UVGI lights is sterilized and the bio contaminants captured on the HEPA are killed or deactivated The UVGI lights should be turned on before the fan starts to run and should stay on after the air blower is stopped to complete the sterilization of the HEPA filter The proper operation of the UVGI lights is monitored by UVGI and BALLAST indicating LEDs which turn on when the UVGI lights are on Operating the PAC System The PAC system should be connected to containment outlet with flex duct to create a negative or positive pressure in the room The machine can also provide air purification as a self standing unit if desired Page 3 OmniAire PAC Instruction Manual 2008 INSTRUCTIONS Continued Before starting the blower turn on the UVGI lights Check that the Ballasts and Lamps status lights came on We recommend leavin
9. wing operation instructions we are assuming that the machine is located inside the enclosure If the machine is located outside the containment the flex hose connections would be reversed To create positive pressure inside the containment more air has to be pumped in than leaks out Connect the flex hose from the outside to the Intake Manifold on the suction side of the machine The outside air is pulled through primary secondary filter under a negative pressure This prevents leakage of untreated air into the containment Then the air passes through blower and over the UVGI lights where it is sterilized and pushed through the HEPA filter to remove any particulates The pure air stream diffused by HEPA is then exhausted into the containment The plastic sides of the containment should be bowed out to indicate positive pressure The speed of the machine can be adjusted to meet your required number of air exchanges and the positive pressure To maintain negative pressure inside the containment in reference to ambient pressure more air has to be exhausted out than leaks into the containment Install the Intake Manifold on the outlet side of the machine and connect the flex hose to the outside All the air exhausted to the outside is treated by UVGI lights and by HEPA filter The plastic walls of the containment will be bowed in indicating negative pressure By increasing fan speed the pressure inside the containment becomes less than the outside pres

Download Pdf Manuals

image

Related Search

Related Contents

Soleus Air FS1-40R-41 User's Manual  Pioneer BDP-150 User's Manual  Les secteurs jouent la carte de la GUP  - Motherboards.org  Panasonic Attune II Operating Instructions  取扱説明書 - fujitsu general  HP LaserJet Enterprise 500 color MFP M575dn  Squiz edit+ guide for kelsi.org.uk How to edit content using /_edit  155 2012  Massive Suspension light 37651/11/10  