1. Residential Split System Heat Pumps turn to the experts fF Dealer Setup Checklist Date Remove from literature packet and place in customer file at dealership NOTE Read the entire installation instruction manual before starting the installation Customer Name Home Phone No Address Business Phone City State Zip Code Outdoor Unit Model No Indoor Coil Model No Outdoor Unit Serial No Indoor Coil Serial No Accessories Furnace Model No Accessories Furnace Serial No Check off the following items when they apply to this installation Check equipment for shipping damage Note Damages Locate and level unit See Installation Instructions under Install on a Solid Level Mounting Pad and Clearance Requirements sections If unit is installed in a low ambient application see Installation Instructions Accessory Usage table Elevate unit to ensure proper drainage Check defrost thermostat to ensure proper location and attachment See Installation Instruction Defrost Thermostat Location figure Ensure proper line set sizes are used See Installation Instructions under Make Piping Connections section and Refrigerant Connections and Recommended Liquid and Vapor Tube Diameters table If line sets exceed 80 ft and or exceeds 3 ft of buried line see Installation Instructions Accessory Usage table for required accessories and appropriate Residential Split System Application Guidelines Install solenoid valve and
2. filter drier when required Consult Product Data Sheet for proper accessory kit Install proper wire size and fuse circuit breaker Consult Product Data Sheet and or local codes for recommended wire size and fuse circuit breaker Connect power and control wiring connections See Installation Instructions under Make Electrical Connections section and 24 v circuit connection figures Power Supply Voltage Volts Control Voltage Volts Evacuate line set and indoor coil per Installation Instructions Piping Connections section Open refrigerant valves and check refrigerant charge See Installation Instructions under Check Charge section Use Superheat Charging procedure and appropriate Charging tables in INstallation Instructions or in unit labels Check refrigerant connections for leaks Suction Pressure psig Outdoor Temperature F Discharge Pressure psig Indoor Temperature F Superheat Subcooling F Check factory tubing to ensure tubes are not rubbing against each other or any sheet metal Pay close attention to feeder tubes on both indoor and outdoor coils Ensure wire ties are tight Check factory wires and wire connections to ensure terminations are secured properly See wiring label on unit for proper wiring identification Check wire routing to ensure wires are not in contact with tubing or sheet metal Check wire routing around fan motor to ensure wires will not come in contact with fan blades Check field wiring for proper
3. support terminations and grounding Check unit charge and adjust accordingly Run unit in cooling heating and defrost modes See Installation Instructions for defrost operation check procedure Before leaving job ensure that all panels and covers are securely fastened and that service valve stem caps are tightened with wrench to 1 12th turn past finger tight Ensure all work areas are clean Leave User s Manual with Owner Always Ask For FACTORY y AUTHORIZE PARIS Copyright 2005 Carrier Corp 7310 W Morris St Indianapolis IN 46231 Printed in U S A Edition Date 11 05 Catalog No CL38 4 Manufacturer reserves the right to cange at any time specifications and designs without notice and without obligations Replaces CL38 2 2

Download Pdf Manuals

image

Related Search

Related Contents

  JVC KD-AR400 Installation Manual  USER`S MANUAL - X-Gloo  コンポジット―Y/Cトランスコーダ FC−10/KR−10 取 扱 説  

Copyright © All rights reserved.
Failed to retrieve file