Home

Quintus reagents Instruction for Use

image

Contents

1. It is important when transferring the reagent tubing that it is kept clean and inserted into the correct reagent container j The analyzer is now ready to resume operation or analyze samples No priming or fill cycle is necessary when putting on a new reagent container if indicator and warning messages are followed k Run three 3 BACKGROUND CYCLES to complete the reagent exchange and to check that the background is below the acceptance limit roo mo o You can always refer to your Quintus User s manual for reagent priming or changing IMPORTANT Remember to verify calibration prior to running patient samples e g using Boule control material Ordering information and service For international customers contact your local distributor for orders and support Description Packaging 1504291 Quintus 5 part Diluent 20 L 1504292 Quintus 5 part Lyse JL 1504293 Quintus 5 part Stopper SL Boule Medical AB Stockholm Sweden onal E mail info boule se C www boule se 13889 1 2010 08 27 page 1 1
2. ih Boule Quintus reagents Instruction for Use Installation Instructions for Quintus Reagents E q A detailed description of reagent installation reagent change can be found in the instrument User s Manual under section 2 Installation L m Intended use The Boule Quintus Diluent Lyse and Stopper reagents are intended for use with the Quintus mR hematology analyzer systems Storage and stability The Boule Quintus reagents are stable at least up until the expiration date as shown on labels when stored at 4 to 35 C Instructions 1 For proper performance DO NOT mix Boule reagents with non Boule products 2 Itis recommended that the Diluent the Lyse and the Stopper reagents are placed at the instrument level or below 3 The interlocked reagent system displays indicator and warning messages to alert the operator when reagents are running low and need to be changed When this occurs perform the following a From the Main menu select ADVANCED and then REAGENTS b Select ENTER NEW REAGENT c Press the text box under the reagent you will scan in it will highlight in yellow when activated and then scan in the barcode from the corresponding reagent container Repeat for all applicable reagents Press ENTER NEW REAGENT to save Select EXIT to return to the Main menu Remove the cap and seal on the new reagent container Transfer the reagent level sensor from the used container to the new reagent container

Download Pdf Manuals

image

Related Search

Related Contents

安全データシート(SDS)  Olympia 9169 laminator pouch    D3011E - Ingrasys  Fujitsu Siemens Computers LifeBook N6460 User's Manual  MD-33  ベルト荷締機用プロテクター 38聖肛  König CSGCIPH4PI mobile phone case  Wisotronic 1-Kanal Bedienungsanleitung  User Manual UNO  

Copyright © All rights reserved.
Failed to retrieve file