Home
        Operating Instruction Manual
         Contents
1.                            Part Number Description  23101 CompacVideo Otoscope System  NTSC     Includes VideoOtoscope Head  10 Disposable  4  mm  Specula  Video Cable  and 71000 A Power  Handle  23100 CompacVideo Otoscope  NTSC     Includes Video Otoscope Head  10 Disposable  4  mm  Specula  and Video Cable  23101P CompacVideo Otoscope System  PAL     Includes VideoOtoscope head  10 Disposable  4  mm  Specula  Video Cable  and 71000 A Power  Handle  23100P CompacVideo Otoscope  PAL     Includes Video Otoscope Head  10 Disposable  4  mm  Specula  and Video Cable  23101SM CompacVideo pee System  NTSC     Includes Video Otoscope Head  10 Disposable  4  mm  Specula  Video Cable  and 71900 Power  Handle  23101P SM CompacVideo Otoscope System  PAL     Includes Video Otoscope Head  10 Disposable  4  mm  Specula  Video Cable  and 71900 Power  Handle  23120 CompacVideo Otoscope Head Alone  NTSC   23120P CompacVideo Otoscope Head Alone  PAL   52434 C Disposable Speculum  4mm  pack of 1 000  45518 Video Cable  03500 Replacement Lamp  72300 Replacement Battery for 71000 A Power Handle  71960 Replacement Battery for 71900 Power Handle  23160 Connector  RCA f to BNC m Adapter          Limited Warranty    One Year Limited Warranty On New Instruments    Instrumentation purchased new from Welch Allyn  Inc   Welch Allyn   is warranted to be free from original defects in the material and  workmanship under normal use and service for a period of one year  from the date of first shipment from We
2.  the  Welch Allyn CompacVideo Otoscope System     4  Attach a Welch Allyn  4 mm  speculum  provided with the system   to the video head by rotating clockwise  The quality of the video  image will deteriorate if other speculum are used     5  Turn on the power switch on the monitor     6  Turn the rheostat on the power handle to FULL POWER  For  optimum performance  the Video System should always be used  with the rheostat set on maximum brightness  The electronic  controls within the Video System will automatically optimize the  brightness of the image     No further adjustments are necessary on the video head  The color and  brightness controls on the video monitor may need to be adjusted to  obtain the best possible picture quality     Using The CompacVideo Otoscope  System    The CompacVideo Otoscope System allows the visual anatomy to be  shared with a patient  Indications for use include       Inspection of the outer ear canal    Inspection of the tympanic membrane    Inspection of hearing aid devices    The CompacVideo Otoscope System should not be used for any other  urposes  For a Video System capable of operating multiple systems  such as otoscopes  sinuscopes  rhinolaryngoscopes  and other   endoscopes   please contact Welch Allyn Customer Service and ask for   information on the Welch Allyn VDX 300     Lamp Replacement     Caution  The lamp base can get very hot  Be certain the lamp has  cooled before attempting to remove the lamp assembly      The CompacVideo Otos
3. ASA SUR BUE IN 3    Using The CompacVideo Otoscope System     5    Lamp Replacement                       5  Battery Replacement                      6  Specifications                            7  Cleaning     Storage                       7  Replacement Parts                        8    Introduction    The Welch Allyn CompacVideo Otoscope System is a portable  battery  operated video camera to be used for obtaining high quality video  images of the ear canal and tympanic membrane for the ear care  pond  The CompacVideo Otoscope System consists of a video   ead  A  and an RCA Video Cable  B   A 3 5 volt Welch Allyn battery  powered handle and a video monitor are necessary for the on screen  display of video images     The CompacVideo Otoscope System is designed for  Plug and Play   operation  meaning that all adjustments including focus  illumination  and white balance are pre set at the factory     Video imaging offers several advantages over direct visualization  A  higher level of magnification allows more detailed viewing of small  structures  The otoscope can also be used to visualize small crevases in  hearing aids  in order to address compliance issues related to hearing  aids  Finally  by using the CompacVideo Otoscope System  ear care  professionals can educate their patients using the product as a  communication vehicle        e       Symbols    A Consult operator   s manual for important information    Type BF    IPXO Not protected against the ingress of water    
4. E  WelchAllyn     CompacVideo Otoscope  Model 23120  NTSC  and 23120P  PAL           Operating    c Instruction  Manual    Thank you for purchasing the Welch Allyn CompacVideo Otoscope  System for ear care professionals  The operating and maintenance  instructions found in this manual should be followed to ensure years  of reliable service  Please read these instructions thoroughly before  using your CompacVideo Otoscope System     If you have questions regarding any Welch Allyn products please call  Customer Service at  800 535 6663         C     sem    74221 N344  ETL listed  Australia EMC Framework  UL2601 1  CSA C22 2 No  601 1  Compliance  IEC 60601 1  AS 3200 1   IEC 60601 1 2    The CE mark indicates this product has been tested  to  and conforms with  the provisions noted within  the 93 42 EEC Medical Device Directive     European Contact for Regulatory Compliance     European Regulatory Manager  Welch Allyn Ltd    Navan Busines Park   Dublin Road   Navan  County Meath  Republic of Ireland   Tel  353 46 67700   Fax  353 46 27128       2000 by Welch Allyn  Inc  All rights reserved  No part of this manual  may be reproduced or transmitted in any form or by any means     electronic or mechanical  including photocopy  without prior consent  in writing from Welch Allyn  Printed in the U S A     Table of Contents    Introduction                             1  Symbols    42 082 244 cidni uona i REY bes 2  Safety  amp  Warnings                        2  SetuP sees eo EXE ERR 
5. Safety  amp  Warnings    DO NOT USE IN THE PRESENCE OF FLAMABLE  ANESTHETICS    In order to obtain optimum video performance and ensure patient  safety  it is important that this booklet be read thoroughly prior to  using the instrument  If you have any technical or clinical questions  concerning the use and   or care of the Video System  please call our  Customer Service Department at  800 535 6663     e The CompacVideo Otoscope System is designed expressly for use  with Welch Allyn 3 5v  rechargeable battery handles  The system  will be damaged if alternate power sources are attached to the  video head  Do not use the video head with a wall transformer             Do not use this instrument for any d other than specified in  this booklet  Doing so will invalidate the instrument s warranty     e Do not use the Video System if you notice any signs of damage to  the components of the system  Contact our Customer Service  Department for immediate assistance     e Do not attempt to disinfect the Video System using gluteraldehyde  products  ethylene oxide gas  steam or any other liquid or gas  disinfectant     NOTE  The video monitor used with this product should comply with  IEC 60601 1 by being an IEC 60601 1 listed monitor  or be  tested to the requirements of the standard when used with the  Welch Allyn CompacVideo Otoscope System     This product has no user serviceable replaceable parts except   A for the lamp and battery  Please refer all other service to  authorized servi
6. ce personnel    NOTE  This product complies with current required standards for  electromagnetic interference and should not present problems  to other equipment or be affected by other devices  As a  precaution  avoid using this device in close proximity to other  equipment     Recycling Batteries    Welch Allyn now employs the services of an agency which can  disassemble and recycle all components of rechargeable batteries so  that nothing gets land filled or incinerated  Should you wish to  dispose of your expended Welch Allyn rechargeable battery via  recycling  in the U S  and Canada only  please send to     Welch Allyn Welch Allyn Canada  RECYCLE BATTERY RECYCLE BATTERY  4341 State Street Road 160 Matheson Blvd  East  Skaneateles Falls  NY Mississauga  Ontario  13153 0220 CANADA L4Z 1V4    For locations outside the U S  and Canada  consult your local recycling  authority for correct disposal of batteries     Setup    1  Attach the Video Otoscope Head to any 3 5V Welch Allyn  rechargeable battery handle  DO NOT ATTACH TO A WALL  TRANSFORMER     2  With the power off  connect the video cable  supplied  to the  output on the back of the Video head     3  Connect the other end of the video cable to the    Input    or    Video  In    on the video monitor  VCR  or other composite video input     NOTE  The video monitor used with this product should comply with  IEC 60601 1 by being an IEC 60601 1 listed monitor  or be  tested to the requirements of the standard when used with
7. cope System uses Welch Allyn lamp   03500   Average lamp life is 20 hours     To replace the lamp  remove the Video Otoscope Head from the power  handle  From the bottom of the Video Otoscope Head  grasp the base of  the lamp and pull straight out  A forceps or needle nose pliers may be  needed to firmly grasp the black lamp Base    Insert the new lamp assembly by pushing the new lamp assembly  firmly into the Video Otoscope Head  Attach the power handle to  firmly seat the lamp  Avoid removing the lamp for reasons other than  replacement        Battery Replacement    Caution  The battery handle must be     Non Convertible  disconnected from the a  supply when removing  batteries     When a rechargeable battery will no longer  accept a charge  replace as follows     DDEZL   ON DOTWLVI    1  Unscrew bottom cap     E     5  3  2  E    2  Shake out old battery        3  Insert replacement battery Important     Please note battery polarity  see figure   Plastic HA  Insulator  Caution  Insert battery fully until gap  seated     For Models 71000 and 71020  non convertible  rechargeable handles  with self contained charger   insure that plastic insulator cap is intact  and securely seated on spring  If missing  or damaged  install new cap  before using     NOTE  For 719 series power handles  please consult the battery  replacement instructions and caution statements provided  with that equipment     Warning     1  Only a Welch Allyn Battery is to be used  Do not use any other  non r
8. echargeable battery     2  Batteries must be removed prior to disposal of product     3  Used batteries are to be disposed of safely and in accordance with  local disposal requirements     4  If leaking batteries are encountered  use protective equipment  when handling batteries to avoid contact of battery fluids with the  skin  Then dispose of batteries safely in accordance with local  authorities     Specifications    Environment    Transport Storage    20  C   49  C  10    95  R H  Max   500hPa   1060hPa Altitude    Operating   10  C   40  C  30    75  R H  Max   500hPa   1060hPa Altitude    Internally Powered Equipment    Duty Cycle Operation  To minimize external otoscope housing temperatures  on time  A should not exceed 90 seconds and off time should not be less  than 10 minutes     Cleaning  amp  Storage    The CompacVideo Otoscope System housings can be cleaned with a  cloth dampened with warm water  alcohol  or a non staining  disinfectant such as Sporicidin   Spray and Towelettes or  MetriSpray    Liquids should not be dripped onto the surfaces of the  Video Otoscope Head or Handle as they are not watertight  Care should  be taken not to scratch the lens of the otoscope  DO NOT USE STEAM   ETO OR OTHER GAS STERILANTS TO STERILIZE THE PRODUCT     The Video Otoscope System should be stored in a dry  temperature  controlled environment  Unnecessary exposure to extremes in  temperature and humidity should be avoided     Replacement Parts                                
9. lch Allyn  This warranty shall  be fulfilled by Welch Allyn or its authorized representative repairing  or replacing at Welch Allyn s discretion  any such defect  free of charge  for parts and labor     Welch Allyn should be notified via telephone of any defective product  and the item should be immediately returned  securely packaged and  postage prepaid to Welch Allyn  Loss or damage in shipment shall be  at purchaser s risk     Welch Allyn will not be responsible for loss associated with the use of  any Welch Allyn product that  1  has had the serial number defaced    2  has been repaired by anyone other than an authorized Welch Allyn  Service Representative   3  has been altered  or  4  has been used in a  manner other than in accordance with instructions     THIS WARRANTY IS EXCLUSIVE AND IN LIEU OF ANY IMPLIED  WARRANTY OF MERCHANTABILITY  FITNESS FOR PARTICULAR  PURPOSE  OR OTHER WARRANTY OF QUALITY  WHETHER  EXPRESSED OR IMPLIED  WELCH ALLYN WILL NOT BE LIABLE  FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES     10    WelchAllyn       Welch Allyn  Inc   4341 State Street Road  Skaneateles  NY 13153  Tel   800  535 6663    Printed in U S A  Part No  231101 Rev  D    
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
manual de instruções do termômetro digital  Switcher Users Manual  User Manual - Gates Harris History  Magnum How to Stories for pdf  Olympus IR-300 Advanced Manual  Dynamically changing music  OMNUC R88D-RP Series User's Manual    Copyright © All rights reserved. 
   Failed to retrieve file