Home

User Manual

image

Contents

1. will be turned ON VRT014 s output turns OFF always after relay s timeout The timeout is programmable VRT0O14 can be configured in two ways a By sending an SMS b By connecting the device to a PC using COM port interface and the VRT014 configuration software o PACKAGE CONTENTS Cardboard box Device VRT014 CD including the required information and software Configuration cable for connection between the device and personal computer GSM antenna Quick start guide Note The package does not include any SIM card The SIM card must be acquired from your GSM service supplier If any part from the package is missing please contact your local dealer seller or the business representative EFEEEEEF TECHNICAL SPECIFICATIONS Power Supply Voltage 9 15 VDC Average Power consumption 2 W Operating Temperature 20 C 40 C Maximum Switching Current 5A Maximum Switching Voltage 240VAC 30VDC Relay programmable timeout 0 5 65 sec Dual Band GSM modem TM1 900 1800MHz Dimensions 90mmx58mmx53mm Picture 1 External view and measurements of the device Dimension 90 x 58 x 53 mm DESCRIPTION OF THE DEVICE AND PRINCIPLES OF FUNCTIONING The device VRT014 consists of a microcontroller and GSM modem The microcontroller receives and processes signals There are 4 light diodes on the external board of the device as shown in picture 2 D 1 Cc g S v Button O amp
2. Before using the device insert a SIM card with an unlocked PIN code check PIN code check may be unlocked by any mobile phone or other appropriate device For more comprehensive information please refer to the internet service provider the owner of the SIM card Picture 3 Inserting SIM card Note the SIM card may only be inserted while the power supply of the device is unplugged After the device is switched on and configured it is ready for use When the device is turned on for the first time please see if it is properly switched on One only needs to watch the signals of the light diodes if the device is switched on properly the signals of the light diodes would be activated as specified in the table Table 1 Boot stage sequences Turn by turn signals of light Description of the status diodes Woden ciate Light diode Power is turned on and starts shining without interruptions Signal strenght The light diode Modem State may flash in accordance of the GSM modem logics The diode may have no flashing Modem state Signal strenght Light diodes Relay and Signal Strength are flashing by turns This status lasts as long as the modem is in progress of being connected to the operator s network Modem state Signal strenght Modem state Signal strenght When the modem has been connected to the operator s network the light diode Relay stops flashing and the light diode Signal Strength starts flashi
3. CTELTONIKA VRT0O14 User s guide V0 8 Thank you for purchasing our product We hope this user friendly device will be helpful in realising your ideas and bringing comfort to your life Please take few minutes to read this manual before starting to work with VRT014 This would make the installation and use of device easier Address Saltoni ki g 10c Vilnius LT 08105 Phone 370 5 2127472 Fax 370 5 276 1380 Email info teltonika lt J gt INTRODUCTION VRTO14 is a very simple device which can be used for authorised door access controlling gates switching of remote equipments car parking systems activate deactivate alarm systems and etc Basically this device can be used in places which require ON OFF switching action This ON OFF functionality of VRTO14 can be achieved by making a phone call Whenever a person calls VRT014 the device compares the phone number of incoming call with the numbers stored in the memory of device If a match is found it means the caller is an authorized person Due to this VRTO14 will turn ON its output in short sending a signal to activate the connected device VRTO14 does not have any answer function therefore the calling person does not have to pay any charges for the call Up to 500 different numbers can be stored in the memory of device In additional you can turn ON the relay by using an external switch input When a logically low signal is given to this input the output
4. IED GND HD 10 4 15 V DC coococeeee 5 F X r4 2 Picture 2 Device VRT014 The light diode Power is directly connected to the Power supply chain of the microcontroller The light diode Modem State is connected to the GSM modem and its status depends on the operation logic of the GSM modem and its specifications The diode may have no flashing The light diodes Relay and Signal Strength are connected to the microcontroller and reflect the status of the device The light diode Relay reflects the signal status of activating the internal relay When the relay is activated the light diode is also on The light diode Signal Strength reflects the Power of the signal received via the GSM modem When the Power is supplied the light diodes Relay and Signal Strength reflect the start of activating the programme and its various stages If the connection is correct the light diodes are flashing alternately as specified in the table below and when the operation status is activated they are operating in accordance to their main functions When the Power is supplied the device checks the whole internal data base of numbers and operation of the memory chip If there is a memory error the device would not switch to operation mode and 2 pulses would be emitted by alternately by the light diode Signal Strength If the GSM modem is not functioning the device would not switch to operation mode and uninterrupted swift short pu
5. Remote Switch Configurator In picture 4 you can see the main window of Remote Switch Configurator It is divided into 3 sections RSC v 1 0 0 24 xj Curent work file D ASC_vw1 0 0 24 Remote Swatch Configurator eric Relay Sethrigs Relay Hes i netaa rns Disable Extemal Switch E Search of a number in the list Control buttons Load From File Write To File Load From Device Write To Device Clear All Configure Part Picture 4 The main window of Remote Switch Configurator Configuration of relay allows the device to switch from ON to OFF mode of the inner relay Device can switch modes automatically after a number of ms which can be entered in Relay Timeout ms field If an external source of a signal button or other sensor will be required in order to switch ON mode you should no place a tick at Disable External Switch You can add up to 500 numbers in the list of numbers Control buttons should be used to Load the configuration from file Load From File Read the configuration of the device Load From Device Delete all fields Clear All Save the configuration of the device to a file Write To File Save the configuration to device s memory Write To Device Start working with Remote Switch Configurator by configuring port Configure Port A port configuration window is shown in picture 5 You should select a Port which a device VRT014 is connected to and
6. he relay would be delayed Example PRTIMT 5000 this message means that the relay must be delayed for 5 seconds after Switching on SMS message containing a command for recording the altered status of receiving an external signal external switch is as follows PSEN x The symbol P should be in the first position x may mean O or 1 1 means that VRT014 can t receive the external switch signal 0 means that the device would switch ON the relay after the external signal has been received Example PSEN 0 means that the device would switch on the relay after the external signal has been received One SMS message may contain several messages containing commands and the messages must be separated by the symbol Example P 001 37012345678 002 37023456789 RTIMT 5000 SEN 1 This message means that the number 37012345678 should be recorded in the 1 first position and the number 37023456789 in the 2 second position the relay must be delayed for 5 seconds after switching on and the external switch signal is disabled There should be no unnecessary symbols or intervals in the message The changes take effect immediately after the reception of the SMS message Qo TELTONIKA o M E CONFIGURATION BY MEANS OF A PERSONAL COMPUTER In order to configure the device using a personal computer you should Install Remote Switch Configurator Connect VRTO14 to a PC using a configuration cable Start
7. lses would be emitted by the light diode Signal Strength In the device the whole internal data base of numbers is being checked by checking the control counting CRC If the control counting does not match the device would rewrite all settings back to manufacturer s values e The enabling of the external switch signal e The time for switching off the relay is set at 5 sec However it is not being used e The data base of numbers is deleted When the device is operating it is possible to connect a personal computer and do the configuration In addition when data is being transmitted from the device to the personal computer and vice versa it does not respond to calls and SMS messages E MAKING THE DEVICE READY FOR WORK After purchasing the device it needs to be configured i e the list of numbers which the device would respond to must be recorded in the memory as well as the parameters of the switching on signal of the operating device When the device is switched on for the first time its data base of numbers is empty The device must be configured by a personal computer and a programme since the configuration command by SMS messages may be received only from numbers which are already available in the data base Note The configuration can be done after the device is bought or at a later stage when the device has been prepared for use The device is fixed onto DIN board and connected as shown in the labelling on the body
8. ng to reflect the Power of the signal being Signal strenght received The light diode is pulsing and the quantity of pulses refers to the Power of the signal One pulse refers to the lowest signal 7 pulses refer o the highest signal Modem state When the device reaches the last stage specified in the table it is ready for use CONFIGURATION BY MEANS OF SMS MESSAGES Note the device will not respond to SMS that contains configuration commands unless senders phone number is entered to Oth position in internal database of phone numbers The device is able to receive 3 types of command messages 1 Recording a number in the data base of numbers 2 Recording the time of the delayed switching off the relay signal 3 Recording the status of receiving an external switching on the relay signal SMS message containing a command for recording a number is as follows P nnn xXxXXXXXX The symbol P should be in the first position instead of nnn there must be a number to be recorded in the device memory Xxxxxxx means a recorded phone number which the device would respond to Example P 001 37012345678 this message means that the number 37012345678 must be recorded in the first 1 position SMS message containing a command for recording the time of the delay of the relay is as follows PRTIMT xxxxx The symbol P should be in the first position xxxxx means the recorded time in miliseconds within which t
9. press OK Settings Fort Baud rate Data bits Stop bits Parity None Flow control Mone gt METHOD OF OPERATION For the switching on signal to be activated the connection of internal relay contacts the user has to dial the device s SIM card number After having received one or two calls the device rejects it if the call matches one of the numbers available in the internal data base of the device If the number does not match the device would not respond to calls The device rejects the switching on signal then the delay time runs out depending on the configuration of the device When the device is operating the list of numbers available in its memory may be edited by means of SMS messages Note device responds SMS that come from the number which was entered at Oth position in the internal data base of numbers gt IMPORTANT The sign on the packaging means that the user s manual provided on a compact disk must be read before using the product y i il The sign on the packaging means that the electric and electronic equipment to be utilised must be stored separately AND LAST f i In case you have problems with the installation and use please address them to the Technical Assistance Department by e mail support teltonika lt