Home
User Manual - CommDTM DP/PA Link
Contents
1. Fig 12 Added field deviceDTM 23 CommDTM DP PA Link Trebing amp Himstedt ProzeRautomation GmbH amp Co KG Online Offline Operation Online Offline Operation Establish an online connection to the PROFIBUS To do so click on an entry in the project window with the right mouse key and select Go Online The existing online connection is shown in the FDT frame application see FDT Frame Application Help Depending on the selected device you can now read out the configuration or write the configuration set in the FDT frame application to the device To do so use the respective function in the context menu Terminate the online connection by clicking on the respective entry in the project window with the right mouse key and selecting Go Offline P Note 1 You need to establish connection for each field device You can terminate the connection for each single field device The connection is established and terminated via the context menu of the respective field deviceDTM If you terminate connection to the CommDTM DP PA Link or to the CommDTM PROFIBUS DP V1 all online connections to the field devices are terminated automatically 24 CommDTM DP PA Link Trebing amp Himstedt ProzeRautomation GmbH amp Co KG General Conditions General Conditions Right to make additions or alterations Trebing amp Himstedt ProzeRautomation GmbH amp Co KG reserves the right to continue development of this us
2. Set the DTM address and click OK 21 um CommDTM DP PA Link Trebing amp Himstedt ProzeRautomation GmbH amp Co KG Example Application PC FieldCare Device Setup Advanced Ele Edit View Device Operation DTMCatalog Tools Window Extras Help bewiesen 5 x Network Tag Con Channel Address Device typ BE f amp Host PC 3 8g CommDTM PROFIBUS DP V1 4j 3 CommD F lt CommDTMDP PALnk 6 Cham 120 B v J F M Fig 11 Added CommDTM DP PA Link Add PROFIBUS deviceDTM Up to 64 PROFIBUS PA field devices can be connected to one DP PA Link Likewise up to 64 field deviceDTMs can be intergated into the project Click Comm DTM DP PA Link gt Add Device with the right mouse key Select the deviceDTM from the device catalog and click OK The window for setting DTM addresses opens Setthe DTM address and click OK Establish an online connection see Online Offline Operation on page 24 22 CommDTM DP PA Link Trebing amp Himstedt Proze automation GmbH amp Co KG Example Application PL FieldCare Device Setup Advanced File Edit View Device Operation DTM Catalog Tools Window Extras Help Osea Sa Network Tag Conn Channel Address Device typ BE Host PC B Rg CommDTM PROFIBUS DP V1 dp 3 CommD E CommDTM DP PAUnk dp Chamn 120 CommD e B RETI
3. After device address modification you need to set the DTM address of the respective deviceDTM to the same address Note Not all devices support device address setting through the CommDTM DP PA Link Device addresses for some field devices can only be set directly at the field device For respective information please refer to the manual of the respective field device vendor mie CommDTM DP PA Link Trebing amp Himstedt ProzeRautomation GmbH amp Co KG Context Menu DTM Addresses Setting DTM Address Procedure for setting DTM address Click CommDTM DP PA Link in the project window with the right mouse key and select the function Add device Select a device from the device catalog and click OK The window for setting DTM addresses opens Set the DTM address and click OK Change DTM Addresses This functionality serves to display and to set the DTM addresses of the field deviceDTMs This function is only available in offline mode The DTM address shown and set is used to establish connection to the respective field device Please make sure to use an identical address both for the field device and for its respective DTM 10 CommDTM DP PA Link Trebing amp Himstedt ProzeRautomation GmbH amp Co KG Context Menu Fig 5 Change DTM addresses Procedure for changing DTM address Click CommDTM DP PA Link in the project window with the right mouse key and select Additional Functions
4. gt Change DTM addresses The scan procedure is performed by clicking the Refresh button Afterwards the devices are listed in the Change DTM addresses window Respective device names DTM vendors and DTM versions can only be displayed if this functionality is supported by the frame application Mark the respective DTM 11 CommDTM DP PA Link Trebing amp Himstedt Proze automation GmbH amp Co KG Context Menu Click into the list box Current DTM address and click Accept In the status bar of the window information is displayed on whether this function has been completed successfully or whether the DTM does not support this functionality S Note 1 This function is not supported by all DTM In this case you can only modify DTM addresses directly through the field deviceDTM in the project 12 CommDTM DP PA Link Trebing amp Himstedt Proze automation GmbH amp Co KG Context Menu About CommDTM DPIPA Link This functionality displays information about the installed CommDTM DP PA Link CommDTM for SIMATIC DP PA Link Fig 6 About CommDTM DP PA Link Procedure for opening the window About CommDTM ET 200M Click CommDTM DP PA Link in the project window with the right mouse key and select Additional Functions gt About CommDTM DP PA Link The information about the CommDTM DP PA Link opens 13 CommDTM DP PA Link Trebing amp Himstedt Proze a
5. ee 17 Design ie RR EE RE OR EO EE LEEREN 19 Online Offline Operation ek ee RR Re Re ek Re ee 24 General Conditions eicere een 25 CommDTM DP PA Link CommDTM DP PA Link The SIMATIC DP PA Link frequently used in process control plants is an essential structural element for the transfer from PROFIBUS DP to PA in complex network structures The respective CommDTM DP PA Link developed by Trebing amp Himstedt ProzeRautomation GmbH amp Co KG can be implemented into all FDT frame applications according to FDT Specification 1 2 Addendum There the DTM functions as a device driver enabling DP V1 communication with the devices at the DP PA Link and their deviceDTMs The CommDTM DP PA Link considerably facilitates configuration parameterization and calibration as well as commissioning diagnosis and maintenance of field devices You can use the CommDTM within one FDT frame application severalfold and concurrently depending on the available DP PA Links in the PROFIBUS network To do so load the CommDTM DP PA Link severalfold into the project window For the PROFIBUS DP V1 communication a respective physical access to the PROFIBUS and a respective CommDTM PROFIBUS DP V1 need to be available see figure 1 on page 5 You can use the Trebing amp Himstedt ProzeRautomation GmbH amp Co KG CommDTM PROFIBUS DP V1 with xEPI 2 or CP5512 CP5611 hardware The CommDTM DP PA Link is protected by software key You need to
6. CommDTM DP PA Link User Manual English Dear Customer This User Manual describes the functionalities of the CommDTM for the SIMATIC DP PA Link in a FDT frame application If you have any further questions please contact our Technical Support Trebing amp Himstedt ProzeRautomation GmbH amp Co KG Technical Support Wilhelm Hennemann Str 13 19061 Schwerin Germany Phone 49 385 39572 500 Fax 49 385 39572 22 E mail support t h de Internet http www t h de The information contained in this User Manual is the property of Trebing amp Himstedt ProzeRautomation GmbH amp Co KG The User Manual and extracts thereof may only be duplicated or forwarded to third parties following explicit written approval by Trebing amp Himstedt Proze automation GmbH amp Co KG We reserve the right to make changes and improvements to this User Manual as well as the hardware and software features at any time and without prior notification All product names used herein are trademarks or otherwise protected by law even if not specifically indicated 2005 2010 Trebing amp Himstedt ProzeRautomation GmbH amp Co KG Doc Version 4 0 January 2010 Content CommDTM DP PA Link FDT Frame Applications Context Menu Change Device Addresses DTM Addresses About CommDTM DP PA Link Help Licensing RA EE RE AE N RE EE 15 Example Application iese ee RA ee AR RR ee ee ee ee ee ee ee
7. er manual and the properties of the hardware and software at any time also without releasing information about this or about alterations prior to doing so Exclusion from liability Trebing amp Himstedt Proze automation GmbH amp Co KG assumes no warranty for proper function of the hardware and software in all conceivable situations Currently available technical means do not enable the development of software which is completely free of errors in all conceivable applications Trebing amp Himstedt ProzeRautomation GmbH amp Co KG does not accept any liability for damages both direct and indirect arising from the use of the hardware and software and the information contained in this user manual Duty to monitor products As part of our duty to monitor products we strive to warn about dangers we have identified which can result from the interaction of hardware and software and product use with third party products Monitoring is only possible if we receive sufficient information from our customers on the planned application s and the existing hardware and software components As a result of the complex interactions it is no longer possible for us to accurately identify all dangers and to check the effect on the overall system and in particular on our hardware and software if the conditions of application have changed and or hardware or software has been exchanged This user manual does not describe all technical characteristics of the
8. hardware and software and their variants For more information please contact Trebing amp Himstedt ProzeRautomation GmbH amp Co KG Warranty Our products are subject to warranty in accordance with our general business and delivery terms 25 CommDTM DP PA Link Trebing amp Himstedt ProzeRautomation GmbH amp Co KG
9. license the software for unlimited use see Licensing on page 15 Without licensing you can use the CommDTM DP PA Link as a demo version with full functionality for 30 days from date of installation CommDTM DP PA Link functionalities can be accessed through the context menu of the used FDT frame application CommDTM DP PA Link Trebing amp Himstedt ProzeRautomation GmbH amp Co KG CommDTM DP PA Link PACTware FieldCare FieldMate FieldCare Device Setup Advanced ZA rie Edit View Device Operation DTM Catalo osasgeag E Q CommDTM PROFIBUS DP V1 xEPI 2 EN CommDTM DP PA Link BE ESK3PA je UGUIPHANT M PA V10 V12 S PROSONIC FLOW 90 PA V2 00 4X CommDTM ET 200SP A CommDTM ET 200M DP PA Link PROFIBUS DP DP PA Link DP PA Link Fig 1 Example of PROFIBUS network with several DP PA Links CommDTM DP PA Link Trebing amp Himstedt Proze automation GmbH amp Co KG CommDTM DP PA Link FDT Frame Applications The different FDT frame applications vary in functionality and appellation of the various functions This user manual refers to the FieldCare frame application with regard to appellations Complete functions for the frame application are described in the FieldCare Help Pans at d d TE IE sa Lo Dot se ora Fig 2 FieldCare r 6 mm CommDTM DP PA Link Trebing am
10. mDTM DP PA Link needs to be online Field device addresses can only be changed if the respective field device supports this function Fig 4 Change device addresses Procedure for changing device address Click CommDTM DP PA Link in the project window with the right mouse key and select Establish Connection The existing online connection is displayed in the FDT frame application see Help for FDT Frame Application CommDTM DP PA Link Trebing amp Himstedt Proze automation GmbH amp Co KG Context Menu Click CommDTM DP PA Link in the project window with the right mouse key and select Additional Functions gt Change device addresses The scan procedure for connected field devices is performed by clicking the Refresh button Afterwards the field devices are listed in the Change device addresses window Respective device names DTM vendors and DTM versions can only be displayed if this functionality is supported by the frame application Mark the respective field device Select a new address from the list box Current device address in the bottom part of the window and click Accept Automatically an online connection to the field device is established the address is modified and the field device disconnected In the status bar of the window information is displayed on whether this function has been completed successfully or whether the field device does not support this functionality Attention
11. p Himstedt Proze automation GmbH amp Co KG Context Menu Context Menu Click an entry in the project window of the FDT frame application with the right mouse key The context menu opens Its entries are default entries of the FDT frame application When you select Additional Functions the respective DTM entries are displayed Functionalities displayed in gray are not supported or already opened To select these functions an online connection might be necessary Integration of the CommDTM DP PA Link into a project is described in the chapter Example Application Ele Edt View Device Operation DTM Catalog Tools Window Extras Heb osaees Network Tag Conn Channel Address Devic BB Host PC Ef CommDTM PROFIBUS DP V1 4 1 E P CommDTM ET 200M dp Chanel 0 110 32 M8 Volume Flow dp Se 8C 0 3 MICROPIL dp Sa8C 0 EP CommDTM ET 200SP ip Channel 0 111 SE CERABAR dp SadC 0 je DELTABAR Se4C 0 i E ITEMP ip Sot 4C 0 E QC CommDTM DP PA Link EER Oe ESGPA 5g add Device je LIQUIPHANT M PA V1 BE Delete Device je PROSONIC FLOW 90 P zard Fig 3 Context menu for the CommDTM DP PA Link CommDTM DP PA Link Trebing amp Himstedt Proze automation GmbH amp Co KG Context Menu Change Device Addresses With this function you can display and change the device addresses of the field devices connected to the DP PA Link To use this function the Com
12. utomation GmbH amp Co KG Context Menu Help This function starts the User Manual in PDF format Adobe Acrobat Reader is required Installation of the Trebing Himstedt DTM Library saves the user manual locally on your system CommDTM DPIPA Link LI esos BERE Fig 7 User Manual 14 CommDTM DP PA Link Trebing amp Himstedt Proze automation GmbH amp Co KG Licensing Licensing The CommDTM DP PA Link is protected by software key You need to license the software for unlimited use Without licensing you can use the CommDTM DP PA Link as a demo version with unlimited functionality for 30 days from date of installation After expiry of the 30 day demo version online connections can no longer be established Online connections existing at the time of expiration will be terminated i Note 1 The license is generated for the current system License transfer to other systems is not possible You can find the current license status in the window About CommDTM DP PA Link context menu gt Additional Functions gt About CommDTM DP PA Link 15 CommDTM DP PA Link Trebing amp Himstedt ProzeRautomation GmbH amp Co KG Types of Licenses In the following table you licenses Licensing find an overview of the types of Type of license Explanation Demo version days without functional limitations remaining DTM is not licensed Trebing Himstedt DTM Librar
13. y Full License License valid for all DTMs from the Trebing Himstedt DTM Library Trebing Himstedt DTM Library Single License Lizenz valid for one DTM from the Trebing Himstedt DTM Library No license demo version expired Online connection cannot be established Endress Hauser OEM License Please ask your distributor for specific OEM licenses 16 CommDTM DP PA Link Trebing amp Himstedt ProzeRautomation GmbH amp Co KG Example Application Example Application The CommDTM DP PA Link allows access to PROFIBUS PA field devices The PROFIBUS communicates acyclically via a MCL2 configuration master For communication with field devices the respective field deviceDTM needs to be integrated into the project of the FDT frame application 17 CommDTM DP PA Link Trebing amp Himstedt ProzeRautomation GmbH amp Co KG Example Application PACTware FieldCare FieldMate FieldCare Device Setup Advanced ZA rie Edit View Device Operation DTM Catalo osasgeag Network Tog BB Host PC E Q CommDTM PROFIBUS DP V1 xEPI 2 EN CommDTM DP PA Link BE ESK3PA MCL 2 je LIQUIPHANT M PA V1 0 V1 2 S PROSONIC FLOW 90 PA V2 00 4X CommDTM ET 200SP Eg CommDTM ET 200M DP PA Link PROFIBUS DP DP PA Link DP PA Link Fig 8 Communication principle to field devices 18 CommDTM DP PA Link Trebing amp Himstedt Pro
14. ze automation GmbH amp Co KG Example Application Design Projects Requirements The following software has to be installed FDT frame application Trebing Himstedt DTM Library PROFIBUS PA field deviceDTM FDT frame application Start the FDT frame application Open and update the device catalog Create a new project Add CommDTM PROFIBUS DP V1 Click Host PC in the project window with the right mouse key and select the function Add device Select CommDTM PROFIBUS DP V1 from the device catalog and click OK Configure the CommDTM PROFIBUS DP V1 To do so open the CommDTM PROFIBUS DP V1 context menu and select Configuration For further information please turn to the CommDTM PROFIBUS DP V1 user manual 19 CommDTM DP PA Link Trebing amp Himstedt ProzeRautomation GmbH amp Co KG Example Application PC FieldCare Device Setup Advanced Ele Edit View Device Operation DTMCatalog Tools Window Extras Help DERSaeB Fig 9 Added CommDTM PROFIBUS DP V1 Add CommDTM DP PA Link Click CommDTM PROFIBUS DP V1 in the project window with the right mouse key and select the function Add device Select CommDTM DP PA Link from the device catalog and click OK The window for setting DTM addresses opens 20 CommDTM DP PA Link Trebing amp Himstedt Proze automation GmbH amp Co KG Example Application Fig 10 Set DTM addresses