Home

User Manual - Omnitec Design

image

Contents

1. Figure 2 To create positive pressure inside the containment more air has to be pumped in than leaks out of the containment Place the machine outside the containment and hook a flexible duct to the outlet ring of the machine ducting the exhaust into the containment See Figure 3 Clean Area Clean Air C ean Air a mS C aS BA VAS uh ra i r Figure 3 MAINTENANCE INSTRUCTIONS REPLACEMENT OF THE PREFILTER Once the CHANGE FILTER light comes on with the machine in HIGH SPEED then the prefilter must be replaced When replacing the prefilter ensure that the orange side of the prefilter 1s facing the HEPA filter At this time the CHANGE FILTER light will go off When the CHANGE FILTER light does NOT go off after replacing the prefilter then the HEPA filter is full and must be replaced to maintain airflow Please note that even though the HEPA filter 1s fully loaded the filter is still removing the particulates from the air but at a reduced airflow which will affect the ability of the machine to provide positive or negative pressure within the containment REPLACEMENT OF THE HEPA FILTER To replace the HEPA filter remove the screen manifold and remove the prefilter You will see 4 filter tabs holding the HEPA filter in place See figure 4 below These tabs are secured with 1 4 20 Nylock nuts which require a 7 16 wrench or socket to remove them Remove all 4 filter tab retaining nuts and r
2. EE O MNITEC DESIGN INC MANUFACTURING HIGH QUALITY ENVIRONMENTAL ABATEMENT EQUIPMENT SINCE 1988 OmniAire 2000C Operations and Maintenance Manual This eguipment to be operated only by trained personnel Do not use with combustible or explosive material Do not expose to water or rain Connect only to grounded outlet with GFCI device Disconnect power for cleaning and servicing CONFORMS TO UL STD 507 CERTIFIED TO CAN CSA STD C22 2 NO 113 M1984 SPECIFICATIONS Motor 1 25hp 115 V 12 0 amps thermal protected Controls HIGH LOW OFF Switch CHANGE FILTER Light Airflow 400 1600 cfm Final Filter HEPA 99 97 a 0 3 micron particle board frame 18 x 24 x11 5 Pre filter 2 stage poly pad 35 efficiency 20 x 25 x 2 Housing Galvanized Steel Weight with Filters 125 lbs Dimensions 34 L x 20 W x 31 H ORDERING INFO 1 csccccssccesssceeess PART OmniAire OA2000C ee eeeeeeeeeeeeeeeeseeseeseeeeeeeens OA2000C HEPA Filter 9997 0 3 M OAH2418 HEPA Filter 99 99 0 3 1 OAH2418G Primary Secondary Filter qty 20 0000008 OFP2518 Intake Manifold 12 ooo aa OAIM2000 12 Life ldnp 127 da ern ee een QCW 12 Flexible Duct 12 x25 aa OAD25 OdorGuard 600 Carbon Filter OG2418D The OmniAire OA20000C comes standard with a particle board 99 97 0 3u HEPA filter HRE RRR and can be upgraded to a metal SARE frame Certified 99 99 0 3u
3. Hittin HEPA zzzzzs at ity 1 1441 b ti b b b b J p t 4 a t b paadid Perre rgtenannaonnnanna n Sr ar er r tr tv erep OPERATING INSTRUCTIONS Unpacking Visually inspect the unit for damage Remove the primary secondary filter and ensure that the HEPA filter has not been dislodged during shipping The HEPA filter should be sitting on the filter guides and the filter tabs that hold the HEPA filter in place should be tight See Figure 1 If the filter 1s not seated correctly then remove the filter tabs reposition the filter and reinstall the filter tabs before operation to ensure that there is no bypass around the filter If the filter tabs are loose verify that the filter is in the correct position and retighten the filter tab nuts x Fu S U W 4 S ORES lt HEPA filter element mounting tab Filter Guides Figure 1 To create negative pressure inside the containment more air has to be exhausted out than leaks into the containment Place the machine inside the containment and hook a flexible duct to the outlet ring of the machine exhausting to outside the containment See Figure 2 All of the air being exhausted has been treated by the HEPA filter so no contaminants are being exhausted from the containment Clean Area Containment Area Contaminated Air Clean Air sed OS re Kas SHIN lt lt Toes p at
4. bent motor mounts If the blower wheel spins freely the next thing to check 1s the capacitor With the HEPA filter still removed from the machine push the blower wheel and as it is spinning turn the power switch on If the machine runs at this point then the problem is in the capacitor Ensure that the wiring connected to the capacitor is plugged in and not broken If the wiring is correct then the capacitor is faulty Replace the capacitor The machine will run for a few minutes then turn off l This machine MUST be run with a HEPA filter in place If you are trying to run it without a filter in place the motor will overheat within a few minutes and the thermal overload in the motor will engage Let the motor cool off for 30 minutes install the filter and try running the machine again If the filter is in place and the machine still shuts off after a few minutes then the motor is faulty Replace the motor The machine vibrates excessively when running l This is an indication that the motor bearings are worn If the machine is allowed to continue running at this point the vibration will cause the center hub of the blower wheel to separate from the wheel requiring replacement of both the motor and blower Replace the motor If the machine does require electrical servicing of the motor or switches the following page contains a wiring diagram to aid in repair or troubleshooting SE BS YA POOMUU TI IZEI 7 woog Buram 3000270 CUIR M
5. IMITATIONS OF WARRANTY THIS WARRANTY IS EXPRESSLY IN LIEU OF ANY AND ALL OTHER WARRANTIES AND OBLIGATIONS OF OMNITEC DESIGN OR ITS SUPPLIERS EXPRESSED OR IMPLIED AND OMNITEC DESIGN EXPRESSLY DISCLAIMS ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE LIMITATION OF REMEDY Under no circumstance shall Omnitec Design or any supplier of Omnitec Design be liable for any loss or damage including but not limited to loss or damage arising out of the failure of the Products to operate for any period of time inconvenience S the use of rental or replacement equipment loss of profits or other economic loss or general direct special indirect incidental or consequential damages or property damages PRODUCT SUITABILITY Many states and localities have codes and regulations governing sales construction installation and or use of products for 2 certain purposes which may vary from those in neighboring areas While Omnitec Design attempts to assure that its Products comply with such codes it cannot guarantee compliance and cannot be responsible for how the Products are installed or used Omnitec Design recommends that before purchasing and using a Product purchasers review the Product S application and federal state and local regulations to be sure that the Products installation and use will comply with them 2 VPPPPPPPPPLLP PLL LAPP ALLA AP PLA LLLP PLL PLL LPP KEEP THIS TOP PORTION FOR YOUR RECORDS VVWWWWWWWWWWW
6. S 45 UL96L C212 apog SB8 O UOJSASY UOSAN UD 53 7 234 UWE IEP HILIAS 3anssaad 13X AU LOW dH AJ 11 Ge 1 L kis Ll nJ CAPACITOR N31 SALIH HOV 14 Omnitec Design Inc 4640 Campus Place Suite 110 Mukilteo WA 98275 Visit us www omnitecdesign com Office 425 290 3922 LOMO NNN OOOO OOOO OOOO NOON OMNITEC DESIGN INC LIMITED WARRANTY g Omnitec Design Inc warrants that all products component parts and accessories excluding filters will be for a period of twelve 12 months from the date of purchase be free from defects in material and workmanship under normal use and 2 service S THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY IS LIMITED TO THE REPAIR S OR REPLACEMENT OF DEFECTIVE PARTS F O B OMNITEC DESIGN INC 4640 CAMPUS PLACE 110 MUKILTEO WA 98275 Ph 425 290 3922 Fax 425 290 3964 In order to keep this in effect the purchaser must 1 return this signed LIMITED WARRANTY to Omnitec Design within 30 days of purchase date 11 have promptly informed Omnitec Design s Customer Service of any defects and 111 properly used and maintained the Product NNNNN NNNNNN NNN This warranty does not cover normal wear and tear or defects due to 1 improper or negligent handling or unauthorized modifications 11 defective or improper premises chemical or electrical influences or 111 weather or other influences of 2 nature 2 L
7. Y LIMITED WARRANTY REGISTRATION The undersigned has read and understood the above Warranty Limitation of Warranty and Limitation of Remedy PRODUCT Purchased Please Circle MiniForce II MF100C OA600N Nitro OA600V OA1000V OA1200PAC OA1200V OA1300V OA1600PAC OA2000V O0A2000C OA2200UL OA2200C OmniForce II OF100V OWF115 OVH230 OWDP Watchman SERIAL PURCHASED FROM DATE CUSTOMER COMPANY PHONE STREET CITY STATE ZIP CODE BY DATE SEND TO OMNITEC DESIGN INC 4640 Campus Place 110 Mukilteo WA 98275
8. emove the filter tabs as well Slide the HEPA filter out along the filter guides and remove it from the machine ALWAYS TREAT THE USED HEPA FILTER AS HAZMAT AND PROCESS IT ACCORDING TO YOUR ESTABLISHED HAZMAT PROCEDURES To replace the HEPA filter ensure that the gasket on the HEPA filter faces inwards toward the flange slide the filter in place along the filter guides and re install the filter tabs and filter tab securing nuts The nuts should initially be tightened to where the stud is flush with the end of the nut This will compress the gasket on the filter approximately 1 2 of the thickness This allows for the filter to be reseated and tightened at a later time if necessary HEPA filter element mounting tab Filter Guides Figure 4 Troubleshooting Your Omnitec Design machine 1s designed and engineered to provide years of trouble free service Occasionally though problems do occur Here are some helpful tips and solutions to common problems The machine does not start or just hums when turned on l Zs Check the circuit you have the machine on and ensure that it has power Remove the HEPA filter and push the blower wheel by hand If it does not move freely or if you hear a grinding scraping noise as you spin it then the blower wheel is touching the side of the blower housing The most common reason for this 1s that due to an impact of some kind the motor mounts have been bent Remove the motor blower assembly and replace the

Download Pdf Manuals

image