Home
User Manual
Contents
1. SX1213 BS1363 13A British style receptacle SX1215 BS546 15A South African Indian style receptacle SX1216 Cee7 7 16A European style receptacle The SX1200 series have a total of 10 rear receptacles eight switched and two always on The SX1200 series also feature a front panel courtesy receptacle which is always on Each receptacle is rated for a maximum load of 10 amps but the total load must not exceed the load specified in the above 2014 SurgeX Electronic Systems Protection Inc table Plug the equipment cords into the always on and switched receptacles as needed to power the equipment The always on and courtesy receptacles where fitted provide power as long as power is supplied to the SurgeX The eight switched rear receptacles provide power only when the front panel switch is on and in the case of RTi products when the remote control input is also activated Indicator Lights The SX1200 series have two three or four indicator lights on the front panel and a polarity indicator lamp on the rear panel Amber polarity light Rear panel all products Indicates that live and neutral are reversed and your SurgeX product will not work as intended If you are using an SX1216 European Cee7 7 connectivity simply reverse the connection If you are using an SX1210 SX1213 or SX1215 consult an electrician to correct and establish a proper polarity Red Power Light All products indicates that power is supplied to th
2. SURGEX energy intelligence DOO RE 8X1200 Series 8001 Knightdale Blvd Suite 121 INSTALLATION INSTRUCTIONS Knightdale NC 27545 2014 SurgeX Electronic Systems Protection Inc surgex com energy intelligence CE SURGEX IMPORTANT SAFETY INSTRUCTIONS The lightning flash with arrowhead symbol CAUTION within an equilateral triangle is intended to RISK OF ELECTRIC SHOCK alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and WARNING CONNECT ONLY TO MAINS SOCKET z P z P p g maintenance servicing instructions in the WITH PROTECTIVE EARTHING CONNECTION i i j literature accompanying the appliance CAUTION 1 2 3 4 5 6 Please read and retain these safety instructions Heed all warnings in the operating instructions and on the appliance Do not use this apparatus near water or moisture Clean only with a dry cloth Install in a good quality 19 equipment rack Do not install near sources of heat such as radiators heat registers stoves or other apparatus that produce heat such as amplifiers N Refer all servicing to authorised
3. ceptacles are on 10mA of current is available at this output but you must use a series resistor if you are using your own LED For most LEDs a 1K resistor will provide suitable brightness If you need less brightness use a larger value of resistor and if you need more brightness use a smaller value of resistor e Connect the LED positive wire to Pin 4 e Connect the LED negative wire to Pin 5 Auxiliary Relay Contacts The auxiliary relay contacts pins 6 amp 7 provide a way to cascade units or to provide confirmation feedback to a central controller When the switched receptacles are on the aux relay contacts are closed There is a 1 second delay before the aux relay closes which gives time for the SurgeX Inrush Current Elimination ICE circuit to operate This short delay in combination with the SurgeX ICE makes it unnecessary to sequence the power to several large loads such as amplifiers because of inrush current SurgeX RTi products when cascaded can turn on a bank of large amplifiers with no inrush current and therefore no risk of blowing a circuit breaker To cascade two or more RTi products connect the aux relay contacts of one unit to the contact closure input of the next unit To provide confirmation feedback connect the aux relay contacts to an input on the central controller The relay contacts are rated for 1 amp at 30 V DC surgex com CE Characteristics Part Number SurgeX Series Mod
4. e Protection Nominal line to neutral voltage UO V 230V Max Cont Operating Voltage Uc V 275VAC Voltage protective level Up V 1KV Max shorted current Isc 3KA Open circuit voltage Uoc 6KV TOV characteristic UT TOV withstand tr 5s Ut 335V Degree of protection IP IP20 Disconnection Device Plug Applicable Power Supply System TN TT IT Polarity indicator near the supply cord Illuminated wrong Off correct Location Indoor Number of ports Two Voltage regulation lt 1 Operation temperature and humidity 40 35 C 30 90 SURGEX energy intelligence Importer XXXX Address XXXX Made in China SURGEX Limited Ten Year Product Warranty AS3112 BS1363 BS546 and CEE7 7 International Products For a period of 10 years from the date of your purchase of any SurgeX international product SurgeX warrants the product AS3112 BS1363 BS546 CEE7 7 standard against defects in materials used by SurgeX or workmanship performed by SurgeX a Covered Product SurgeX s obligations with respect to a Covered Product are to provide at no charge all labor and parts either new or rebuilt as determined in SurgeX s sole discretion necessary for the repair of the Covered Product If SurgeX in its sole discretion determines that a Covered Product is not repairable SurgeX will replace the Covered Product with a product of like kind quality and func
5. e unit and the power switch is turned on Green Self Test Light All products indicates that power is supplied to the unit and the internal surge protection circuitry is fully functional Orange Over Under Voltage Protection Light RTi amp RLi products indicates that the mains voltage is below 190 volts or above 280 volts Yellow Remote Light RTi products indicates that the remote control is active and the rear switched receptacles are on The power switch must also be on Lamp Connectors RLi Only The RLi version has provision for two Task Lamps Plug the Lamps into the two three pin XLR connectors on the front panel and use the dimmer to set a suitable brightness Standard or HI brightness Lamps can be used Each connector can supply up to 5 Watts maximum LED type Lamps can be used with the RLi but the dimmer must be set fully clockwise surgex com CE CAUTION Do not repeatedly turn an RTi RLi product on off on off with a heavy load connected The ICE circuitry absorbs the inrush energy each time the unit is turned on and may overheat if this is done repeatedly in a short period of time Wait one minute between repeated turn ons Remote Control RTi Products Only Remote control connections are wired to the green 7 pin plug in Phoenix terminal block on the rear of the unit next to the power cord The terminal block is shipped with a jumper wire between pins 1 amp 2 so that the unit can be used without a re
6. eX Electronic Systems Protection Inc surgex com CE SX1 200 Series SURGEX energy intelligence SURGE ELIMINATOR amp POWER CONDITIONER Installation Instructions Caution The SurgeX 1200 series products permit a maximum 16A SX1216 models 15A SX1215 models 13A SX1213 models or 10A SX1210 models total output load with a maximum 10A load per outlet Please check and make sure that each load connected to the unit does not exceed 10A Also make sure that the total does not exceed your mains receptacles current limit For safety please plug your SurgeX unit into a fused receptacle T20AL 250v fuse recommended SurgeX Series Mode Protection is Live Neutral only if the polarity indicator is illuminated when connected to the mains please replace the plug observing correct polarity Mounting The SurgeX SX1200 series are designed to be installed in a 19 inch equipment rack and require one unit 1 U of rack space Remove the product from its packaging and slide it into place in the rack being careful to feed the power cord into the rack first and guide it so that it does not get caught or jammed as the product is installed 230 Volt Connections Connect power to the unit by plugging the cord into a 230V mains receptacle The SX1200 series must be plugged into the appropriate properly polarized receptacle Model Standard Total Load Receptacle SX1210 AS3112 10A Australian style receptacle
7. mote control connection If you will be using a remote control you will first need to remove this jumper wire You can unplug the terminal block to make connections and after you have made the connections to the terminal block plug it back into the connector on the rear of the unit Never solder tin wires before inserting into a terminal block solder cold flows and you will eventually have loose connections The connections are as follows Pin 1 Contact Closure Pin 2 Contact Closure Applied Voltage Pin 3 Applied Voltage Pin 4 Remote LED Pin 5 Remote LED Pin 6 Aux Relay Contact OOOOULLI Pin 7 Aux Relay Contact Control Connections Control of the switched receptacles can be accomplished by using a switch contact closure another SurgeX RTi product or by an applied voltage 5 to 30 volts DC When using a switch choose a switch with gold contacts for the best long term reliability Connections are made to terminal block pins 1 2 amp 3 as follows e Connect switch contacts a contact closure or Surgex control to pins 1 and 2 Or e Connect an applied DC voltage to pins 2 and 3 The positive must be connected to pin 2 and the negative must be connected to pin 3 2014 SurgeX Electronic Systems Protection Inc SURGEX energy intelligence Remote Indicator LED Connecting the Remote LED is optional An LED connected to pins 4 and 5 will indicate when the switched re
8. personnel 8 Servicing is required when the apparatus has been damaged in any way including Impact damage power cord supply damage liquid spillages small objects falling into the unit or exposure to moisture In addition please refer to authorised service personnel if the apparatus is not operating normally 9 To completely disconnect this equipment from the AC mains disconnect the power plug from the AC receptacle 10 To prevent fire never place the unit near any naked flame such as a candle 11 This is a CLASS 1 device and shall be connected to a mains socket with a protective earth connection 12 Do not defeat the purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are there for your safety If the plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet Management of WEEE Waste Electrical and Electronic Equipment Applicable in member states of the European Union and other European countries with individual nation policies on the management of WEEE The symbol on the product or its packaging indicates that this product may not be treated as regular household waste It should be returned to the retailer where the product was purchased or local collection systems should be used to ensure environmentally safe recycling 2014 Surg
9. tionality In order to obtain the services under this Limited Warranty you are responsible for delivering the Covered Product at your sole cost to a SurgeX authorized distributor and for providing the SurgeX authorized distributor with a copy of the dealer s dated bill of sale as evidence of the date of purchase of the product THIS LIMITED WARRANTY IS THE SOLE AND EXCLUSIVE WARRANTY MADE BY SURGEX WITH RESPECT TO THE PRODUCT ALL IMPLIED WARRANTIES WITH RESPECT TO THE PRODUCT INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR IMPLIED WARRANTIES ARISING OUT OF COURSE OF DEALING OR USAGE OF TRADE ARE HEREBY EXPRESSLY DISCLAIMED AND EXCLUDED This Limited Warranty does not apply to any product which is defective due to any causes beyond SurgeX s control such as negligence abuse misuse acts of god modifications to the product or third party repair of the product THE LIABILITY OF SURGEX IF ANY AND YOUR SOLE AND EXCLUSIVE REMEDY FOR ANY ALLEGEDLY DEFECTIVE SURGEX INTERNATIONAL PRODUCT SHALL BE LIMITED TO REPAIR OR REPLACEMENT OF THE PRODUCT IN ACCORDANCE WITH THE TERMS AND CONDITIONS OF THIS LIMITED WARRANTY IN NO EVENT WILL SURGEX BE LIABLE FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES 2014 SurgeX Electronic Systems Protection Inc surgex com