Home

QJ61CL12 CC-Link/LT Master Module User`s Manual (Hardware)

image

Contents

1. ITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN Specifications subject to change without notice Printed in Japan on recycled paper
2. MITSUBISHI QJ61CL12 CC Link LT Master Module Thank you for purchasing the Mitsubishi general purpose programmable controller MELSEC Q Series Before starting use please read through this manual and the details manual to ensure correct usage User s Manual Hardware QJ61CL12 U HW JE MELSEG Q Mitsubishi Programmable Controller 13JP01 IB NA 0800232 D 0809 MEE 2002 MITSUBISHI ELECTRIC CORPORATION SAFETY PRECAUTIONS Always read these instructions before using this equipment Before using this product please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly These instructions apply only to Mitsubishi equipment Refer to the user s manual of the CPU module to use for a description of the programmable controller system safety instructions In this manual the safety instructions are ranked as DANGER and CAUTION Indicates that incorrect handling may cause hazardous DANGER conditions resulting in death or severe injury Indicates that incorrect handling may cause hazardous conditions resulting in medium or slight personal injury or physical damage N CAUTION Note that the A CAUTION level may lead to a serious consequence according to the circumstances Always follow the instructions of both levels because they are important to personal safety Please save this manual to make it accessible when requi
3. connected to the module with a hand and pull it out For the cable connected to a terminal block loosen the screws on the terminal block and disconnect the cable Pulling the cable with it connected to the module may result in malfunctions or damage to the module and or cables ABOUT MANUAL The following manual is also related to this product In necessary order it by quoting the details in the table below Related Manual Manual number SH 080351E CC Link LT Master Module User s Manual 13JR62 Conformation to the EMC Directive and Low Voltage Instruction 1 For programmable controller system To configure a system meeting the requirements of the EMC and Low Voltage Directives when incorporating the Mitsubishi programmable controller EMC and Low Voltage Directives compliant into other machinery or equipment refer to Chapter 9 EMC AND LOW VOLTAGE DIRECTIVES of the QCPU User s Manual Hardware Design Maintenance and Inspection The CE mark indicating compliance with the EMC and Low Voltage Directives is printed on the rating plate of the programmable controller 2 For the product No additional measures are necessary for the compliance of this product with the EMC and Low Voltage Directives 1 Overview This manual describes the specifications names of each part and the settings etc for the QJ61CL12 CC Link LT master module hereinafter QJ61CL12 used in combination with the MELSEC Q Series programmable co
4. e given below 1 The module is mode of resin Do not drop or give it a strong impact 2 Do not remove the PCB printed circuit board from the case Doing so may cause failure 3 When wiring be careful not to let foreign matter such as wiring chips enter the module inside Remove it if this happens 4 The module has an ingress prevention label on its top to prevent foreign matter such as wire offcuts from entering the module during wiring Do not peel this label during wiring Before starting system operation be sure to peel this label because of heat dissipation 5 Tighten the module fixing screws within the following ranges Tightening torque range Module fixing screw M3 screw 1 0 36 to 0 48N m 1 The module can be easily fixed onto the base unit using the hook at the top of the module However it is recommended to secure the module with the module fixing screw if the module is subject to significant vibration When removing the terminating resistor due to any system modification be sure to power OFF the system Removing Installing the terminating resistor with the power ON may cause malfunctions faulty input output 3 2 Installation environment Refer to the User s Manual of the CPU module in use 3 3 Cables Connectors and Terminating Resistors For inquires about the cables connectors and or terminating resistors refer to the following http www cc link org 4 Name of Parts and Setting Conte
5. ld result in damage to the product Do not directly touch the module s conductive parts or electronic components Touching the conductive parts could cause an operation failure or give damage to the module Wiring Precautions Be sure there are no foreign substances such as sawdust or wiring debris inside the module Such debris could cause fires damage or erroneous operation The module has an ingress prevention label on its top to prevent foreign matter such as wire offcuts from entering the module during wiring Do not peel this label during wiring Before starting system operation be sure to peel this label because of heat dissipation For the CC Link LT use the cables specified by the CC Link Partner Association The performance of the CC Link LT cannot be assured if any other cables than the specified are used Also observe the network wiring specifications given in Chapter 2 Normal data communication is not guaranteed if the wiring is not conducted according to the specifications Place the communication cables or power cables for the module in a duct or to fasten them with clamps If not the dangling condition shift or inadvertent pulling of the cables may lead to damage to the module or cables or a malfunction due to faulty cable connection When disconnecting a communication cable or power cable from the module do not hold and pull the cable portion by hand For the cable with a connector hold the connector
6. ntroller CPU 2 Specifications 2 1 Performance specifications The performance specifications of the QJ61CL12 are shown below Refer to the user s manual of the CPU module in use for the general specifications of the QJ61CL12 Pe pointmode 8 point mode 16 point mode _ Maximum link points 256 points 512 points 1024 points When the same I O address is used 512 points 1024 points 2048 points Link points per station 16 points When the same I O address is used 8 points 16 points 32 points Number of l 128 points 256 points 512 points Control i 2 5Mbps specifications 625kbps 156kbps 512 points 1024 points Communication path T branch type cat e l l Network diagnosis internal loopback diagnosis station A ncuane detach function automatic return function Dedicated flat cable 0 75mm x 4 5 VCTF cable 4 High flexible cable 5 Connection cable 1 I O occupied points 2 5VDC intemal current consumption Voltage 20 4 to 28 8V DC Current consumption 0 028A Current on startup 0 070A 0 09kg 1 Performance of the CC Link LT cannot be guaranteed for use of cables other than the dedicated flat cables VCTF cables and high flexible cables 2 Set with the operation setting switch Refer to Chapter 4 3 Supplied through the dedicated power supply or power supply adapter 4 For VCTF cable specifications refer to Table 2 1 5 Use the dedicated flat cables and high flexible cables accredited by the CC Link Par
7. nts 1 LED indicator Module condition is checked with LED status Description QJ61CL12 RUN ON Module operating normally OFF Fault in hardware ERR ON Faulty switch setting Blink Switched during operation lt When normal gt ON Data link being executed OFF Data link stopped lt ln test mode gt ON Self loopback test resulted in normal OFF Self loopback test failure lt Usually gt ON Faulty data link station or station outside control range detected Blink Data link failure at all stations lt In test mode gt ON Self loopback test failure OFF Self loopback test resulted in normal SD ON Data being transmitted ON _ Data being received Setting I O points occupied transmission rate etc of QJ61CL12 Factory setting OFF VO points 46 pis 128 pts 256 pts 512 pts 1024 pts OFF 156kbps 2 5Mbps OFF OFF OFF ON ON int mode 8 point mode Setting prohibited Test mode g TEST OFF ON LINE Normal operation m i 2 Operation setting 1 7 1 7 0 O O POINTS FF FF ON ON OFF OFF ON OFF OFF on on ON ON ON Transmission rate setting Setting prohibited HE W S 4 m zZ nu Qo ODE Operation setting switches Se i ON Test mode Self loopback test When the switch is set to this ERR LED will light up 3 CC Link LT interface Connector for CCLink LT communication line connection connector Serial number plate Indicates the serial No
8. of the QJ61CL12 The settings of operation setting switches become valid when the module is turned ON from OFF or when the programmable controller CPU is reset When any of settings are changed with the module powered ON ERR LED will blink In this case turn OFF and restart the system 5 External Wiring The connection method of the CC Link LT connection cables is described below 1 The cables can be connected regardless of the order of the station number 2 Be sure to set the QJ61CL12 at the end of the trunk line The terminating resistor close to the QJ61CL12 should be connected within 20cm from the QJ61CL12 3 Connect terminating resistors to the both ends of the trunk line of CC Link LT without fail 4 For required number of the connectors refer to the CC Link LT Master Module User s Manual 6 External Dimensions QJ61CL12 RUN LRUN SD RD ERR LERR Oo o Oo oO Oo oO Oo T Unit mm inch Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties For safe use e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured
9. red and always forward it to the end user Design Precautions Do not bunch the control wires or communication cables with the main circuit or power wires or install them close to each other They should be installed 100mm 3 9inch or more from each other Not doing so could result in noise that would cause erroneous operation Installation Precautions Use the programmable controller in an environment that meets the general specifications contained in the CPU user s manual to use Using this programmable controller in an environment outside the range of the general specifications could result in electric shock fire erroneous operation and damage to or deterioration of the product While pressing the installation lever located at the bottom of module insert the module fixing tab into the fixing hole in the base unit until it stops Then securely mount the module with the fixing hole as a supporting point Incorrect loading of the module can cause a malfunction failure or drop When using the programmable controller in the environment of much vibration tighten the module with a screw Tighten the screw in the specified torque range Undertightening can cause a drop short circuit or malfunction Overtightening can cause a drop short circuit or malfunction due to damage to the screw or module Completely turn off the externally supplied power used in the system before mounting or removing the module Not doing so cou
10. seo ku Branch Seoul 157 200 Korea Travellers Lane Hatfield Hertfordshire Tel 82 2 3660 9552 AL10 8XB UK Singapore Mitsubishi Electric Asia Pte Ltd Tel 44 1707 276100 307 Alexandra Road 05 01 02 Italy Mitsubishi Electric Europe B V Italian oe arene Building oar EENT i Tel 65 6470 2460 entro Dir Colleoni Pal Perseo Ingr Thailand Mitsubishi Electric Automation Thailand Via Paracelso 12 l 20041 Agrate Brianza Co Ltd Milano Italy Bang Chan Industrial Estate No 111 Tel 39 039 60531 Moo 4 Serithai Rd T Kannayao Spain Mitsubishi Electric Europe B V Spanish A Kannayao Bangkok 10230 Thailand Branch Tel 66 2 517 1326 Carretera de Rubi 76 80 Indonesia P T Autoteknindo Sumber Makmur E 08190 Sant Cugat del Valles Barcelona Spain Tel 34 93 565 3131 Muara Karang Selatan Block A Utara No 1 Kav No 11 Kawasan Industri Pergudangan Jakarta Utara 14440 France Mitsubishi Electric Europe B V French E E a aA Tel 62 21 6630833 Branch Indi Messung Systems Pvt Ltd 25 Boulevard des Bouvets F 92741 naa I l Uni Electronic Sadan NO III Unit No15 Nanterre Cedex France M I D C Bhosari Pune 411026 India TEL 33 1 5568 5568 Tel 91 20 2712 3130 South Africa Circuit Breaker Industries Ltd Australia Mitsubishi Electric Australia Pty Ltd Private Bag 2016 ZA 1600 Isando 348 Victoria Road Rydalmere South Africa N S W 2116 Australia Tel 27 11 928 2000 Tel 61 2 9684 7777 M
11. tner Association Refer to Section 3 3 Table 2 1 VCTF cable specifications Extract from JIS C 3306 Conductor Conductor Type No of Nominal Composition Outside Insulator Sheath resistance cores cross sectional No of wires wire 4 5 ctor thickness thickness 20 C area diameter Vinyl cabtyre 2 25 10 2 2 Network wiring specifications The network wiring specifications of the CC Link LT are given below 24VDC power supply Item Transmission rate 2 5Mbps 625kbps 156kops Distance between stations No limited a SE Max No of stations on a drop line o 8 o S e O Cable length between 2 Length of trunk line terminating resistors Drop line length not included T branch interval Nolmited S o O T branch f canes Length of trunk line Drop line not included gt Master station k gt Interval length of T branch T Terminating ine Power Remote Remote Remote Remote Remote Terminating resistor supply station station station station station _ resistor adapter Remote Remote station jj station i Distance Ceng drop lite between stations Trunk line Remote Remote station station Drop line Remote station 3 Mounting and installation 3 1 Precautions for handling The precautions for handling the module ar
12. to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system D Country Region Sales office Tel Country Region Sales office Tel U S A Mitsubishi Electric Automation Inc Hong Kong Mitsubishi Electric Automation 500 Corporate Woods Parkway Vernon Hong Kong Ltd Hills IL 60061 U S A 10th Floor Manulife Tower 169 Electric Tel 1 847 478 2100 Road North Point Hong Kong Brazil MELCO TEC Rep Com e Assessoria Tel 852 2887 8870 Tecnica Ltda China Mitsubishi Electric Automation a Dj Shanghai Ltd Rua Correia Dias 184 g Edificio Paraiso Trade Center 8 andar 4 F Zhi Fu Plazz No 80 Xin Chang Road Paraiso Sao Paulo SP Brazil PE E raed Tel 55 11 5908 8331 Taiwan Setsuyo Enterprise Co Ltd Germany Mitsubishi Electric Europe B V German 6F No 105 Wu Kung 3rd Rd Wu Ku Branch Hsiang Taipei Hsine Taiwan Gothaer Strasse 8 D 40880 Ratingen Tel 886 2 2299 2499 GERMANY Korea Mitsubishi Electric Automation Korea Tel 49 2102 486 0 Co Ltd U K Mitsubishi Electric Europe B V UK 1480 6 Gayang dong Gang

Download Pdf Manuals