image

Contents

1. f Ventilation tilstande Locked indicator Indicates that remote controller buttons have been locked Clean The Filter and The Lossnay Core indicators Comes on when it is time to clean the filter and Lossnay core Timer indicators The indicator comes on if the corresponding timer is set Automatic Fan Speed indicator Displayed during automatic fan speed operation ERROR CODE indicator Indicates the ventilation mode Heat exchange Displayed together with the malfunctioning unit 3 digits and an error code 4 digits status HEAT EX Xx xX By pass BY PASS KA Automatic AARETE Heat ex By pass or Bcd AUTO ad BY PASS 9K Fan Speed Adjustment indicator Used to select the fan of either Extra Low Low High Extra High Ff Saa Sal Extra Low Low Extra High High Power On indicator Indicates that the power is on Operation Section Operation lamp ON OFF button On during operation Flashes Switches between run and stop when a malfunction occurs sa MITSUBISHI ELECTRIC Switches between Operation and 24 hour Ventilation Extra Low fan speed Function selector when 24 hour Ventilation is set button Used to select the ventilation mode from among He
2. MITSUBISHI CE A ELECTRIC Lossnay Component for residential commercial or light industrial use Lossnay Remote Controller PZ 60DR E Operating Instructions N Contents 1 Safety Precautions asnan ea a a E EEAS 2 a MITSUBISHI ELECTRIC LOUTNAY 2 Parts NaMe S tecscsieesceesyer Jas eosin 4 3 Setting the Day of the Week and Time ccceeeeeeeeteeeteeeteees 6 4 Using the Remote Controller c ccccccccccecceccseeeseeeeeeeeeeeeeeesteeenaes 7 QonoFF Typical System Setup nsei ran ie eee ences eaten ecient 7 oC Using the TMG ls c cccniaistectienancivnectsnceddad anc dasuacdadvedshieadsnvecdshdeddshtudtantadden 9 Using the Weekly Timer cccccscecsecseseeseeeseeseeseeseeteseeneeeeseenses 9 Using the Simple Timer c cccccccscsescscssssescesssestescstesesesceseseenes 12 Using the Night PUJO saiisscescceicssteecsceecesieeasieaciendiccnenneacesecnaenceense 14 Using the operation lOCK ceeceeeceeseeseteeeeeeeeeeeeeeeeeseneeeeeeeeaeeeneesees 15 Centrally Controlled i cc0 ccccccesescceesccacceccicsecsntastcesencaceastiess ence esedeeissce 16 When interlocked with external device eeeeeeeteeeeeteeteretereeeeeee 16 This remote controller is to be connected to a Lossnay unit to allow that unit to 5 Care and Maintenane ssseeeeeeeeeceeessssieeeeeceeeessssnntneteceeeeesnaey 16 be started and stopped and to allow selection of the ventilation mode and of the 6 S
3. Press the ON OFF button and confirm that the Operation lamp turns on Operation lamp High oe HEAT EX 7 Press the Function selector button Each time it is pressed the corresponding display will 2 Setting the ventilation mode X change in accordance with the sequence HEAT EX non automatic gt BY PASS non HEAT EX non automatic 8utomatic gt AUTO hall Press the Fan Speed Adjustment button to select either Low or High Extra High fan 3 Selecting the fan speed J Ba Dal speed High and Extra High can be selectable by initial setting Low Extra High of Press the Extra Low fan speed button 4 Selecting the Extra Low fan a Extra low operation will begin Pressing the Fan Speed Adjustment button will cause the speed C fan speed to revert to its original speed before the Extra low mode began Extra Low Pressing the Extra Low fan speed button again will return operation to Extra low mode ON OFF 5 Stopping the Lossnay unit Press the ON OFF button P Operation lamp Press the ON OFF button to turn off the Operation lamp If you press a button for a feature that is not installed at the Lossnay unit the remote controller will display the NOT AVAILABLE message 2 If set to 24 hour Ventilation pressing the ON OFF button will cause this to be displayed in the dot display 24HR VENTILATION a
4. BACK button before pressing the lt 4 TEF Vent si PEET button If you have set two or more different operations for exactly the same time only 7 We SA Foal the operation with the highest Operation No will be carried out 10 o OA SRA weer 10 Repeat Steps 3 to 9 as necessary to fill as many of the available cells as you wish 11 Press the BACK button to return to the standard control screen and complete the setting procedure 12 To activate the timer press the ON OFF button so that the Timer Off indication disappears from the screen Be sure that the Timer Off at 10 indication is no longer displayed If there are no timer settings the Timer Off at fol indication will flash on the screen 11 Using the Simple Timer lt How to Set the Simple Timer gt E You can set the simple timer in any of three ways D 4 Start time only The Lossnay unit starts when the set time has elapsed Stop time only The Lossnay unit stops when the set time has elapsed Start amp stop times The Lossnay unit starts and stops at the respective elapsed times E The simple timer start and stop can be set only once within a 72 hours period The time setting is made in hour increments Timer Setting oo Action ON or OFF Be sure that you are at a standard control screen and that the simple timer Wint
5. Manual 5 Function If locking has been disabled in Function Selection of remote controller the Selection 2 1 screen will display the NOT AVAILABLE message when you press the buttons Specifically you can use either of the following two lock types as described above Lock All buttons Locks all of the buttons on the remote controller 2 Lock All Except ON OFF button Locks all buttons other than the ON OFF 1 button AVAILAELE BUTO HEAT EX oe SA Note OA XRX RA The Locked indicator appears on the screen to indicate that buttons are currently locked If you press a locked button the Locked indication at 1 will blink on the Locked will be displayed when operation is locked via Function Selection display In addition Locked will be displayed during Night purge external fan speed adjustment input automatic fan speed fan speed and function selector adjustment ae VENT input Function Selection mode when using two remote controllers and also in AUTOTHEAT EX pees Saa OA RA maintenance mode lt How to Unlock the buttons gt 1 While holding down the FILTER button press and hold down the ON OFF button for 2 seconds so that the Locked indication disappears from the a MITSUBISHI ELEC
6. below Example 1 Start the timer with ON time set sooner than OFF time ON Setting 3 hours OFF Setting 7 hours Soe MENT Fanaa LATION AUTO HEAT EX OA m At Timer Start At 3 hours after Example 2 Start the timer with OFF time is sooner than ON time ON Setting 5 hours OFF Setting 2 hours aii AUTOIHEAT EX OA OH 205 VENT LATIOH AUTO HEAT EX OA 13 h timerstart 7 _ At 7 hours after timer stop At Timer Start At 2 hours after timer start At 5 hours after timer start Display shows the timer s ON setting hours remaining to ON Display changes to show the timer s OFF setting hours remaining to OFF The time displayed is OFF setting 7 hours ON setting 3 hours 4 hours The Lossnay unit goes off and will remain off until someone restarts it Display shows the timer s OFF setting hours remaining to OFF Display changes to show the timer s ON setting hours remaining to ON The time displayed is ON setting 5 hours OFF setting 2 hours 3 hours The Lossnay unit comes on and will continue to run until someone turns it off Using the Night Purge Night purge operation is used in the summer to automatically ventilate a room at ni
7. if two different timers are set in the two remote controllers Using the Weekly Timer The weekly timer can be used to set up to eight operations for each day of the week e Each operation may consist of any of the following ON OFF time together with fan speed setting or ON OFF time only or fan speed setting only When the current time reaches a time set at this timer the Lossnay unit carries out the action set by the timer E Time setting resolution for this timer is 1 minute Examples 8 00 9 00 12 00 13 00 17 00 20 00 22 00 i i Low High Low G dHigh Low Extra Stop Low Note 1 The weekly timer will not operate when any of the following conditions is in effect The timer feature is off the user is in the process of setting a function the user is in the process of setting the timer the user is in the process of setting the current day of the week or time the system is under central control Specifically the system will not carry out operations unit on unit off setting that are prohibited during these conditions 2 The Weekly timer may be used if the clock use setting is ON use clock in Function Selection 9is lt How to Set the Weekly Timer gt 1 2 2 3 Day Setting 4 Operation No 3 a MITSUBI HI ELECTRIC LOS NAY j Tie SET JH EHTER QMENU ON OFF Be sure that you are at a standard control screen and t
8. to fire or equipment failure Turn off this equipment immediately if operation becomes abnormal Continued use may lead to equipment failure electric shock or fire If you notice a burning smell or other abnormality turn off the power switch immediately and consult your dealer Do not attempt to modify or repair this equipment yourself Attempted modification or repair may lead to fire electric shock or other severe accident Please consult with your dealer if repair is required Stop using this equipment if it fails to operate correctly if error messages recur and the unit does not run as expected Continued use or attempted use of this equipment may lead to fire or equipment failure Consult your dealer for advice A CAUTION Keep hazardous materials away from this equipment Do not install this equipment in locations where there is risk of combustible gas leakage The presence of combustible gas may result in explosion or fire Do not use sharp tipped objects to press the buttons Use of sharp tips may lead to electric shock or equipment failure Do not wash this equipment with water Washing with water may result in electric shock or equipment failure Do not touch buttons when hands are wet Doing so may result in electric shock or equipment failure Do not use under extreme temperatures Use only when ambient temperature is within the limits indicated in t
9. will start after 30 minutes and thereafter the time display will decrement each minute To set Ventilation mode Fan Speed Selection Timer Operation Lock Settings are the same as for a single Lossnay unit see page 8 5 Care and Maintenance Button Display Sequence Cleaning of the Clean the air filter Press the FILTER Lossnay unit s ENNS button twice and confirm that the filter FILTER FILTER FILTER CLEANING display turns i e resetting the O off total Lossnay unit Displayed after every 3 000 hours of operating time cumulative operation time Clean the Lossnay core Press the _ FILTER button twice and confirm that Cleaning the pier ELEANINGI the CORE CLEANING display Lossnay core O CORE turns off Displayed after every 6 000 hours of cumulative Lossnay ventilation time To remove dirt from the remote controller s display window Use a mild detergent on slightly damp cloth wipe with a dry cloth to remove any detergent residue e Paint thinner alcohol benzene gasoline kerosene spray cleaner cleaning alkali etc Cleaning the remote controller Clean check and replace according to the Operation Manual provided with the Lossnay unit Factory default setting is for no remote controller 16 6 Servicing lt Flashing Error Codes gt Basic S
10. ENVICING as a EEEa eR EEEa ESEE NNE 17 fan speed 7 Specifications sur riai Ere E E E 18 In order to ensure that the remote controller and Lossnay unit can be operated both correctly and safely it is important that this user s manual be read fully and carefully E Safety Precautions m Precautions are classified as follows according to the level of potential danger A WARNING Denotes a condition or operation which if handled incorrectly may lead to serious injury or death A CAUTION Denotes a condition or operation which if handled incorrectly may lead to bodily injury or property damage A WARNING Do not attempt to install this equipment yourself Please have your dealer or a qualified engineer install this equipment Improper installation may result in fire electric shock or other severe accident Do not attempt to relocate this equipment yourself Improper reinstallation may result in fire electric shock or other severe accident Please have your dealer or a qualified engineer carry out relocation Be sure that the equipment has been fastened securely Be sure that equipment is securely fastened to a sturdy support so that there is no risk that it will fall Do not dispose of this equipment yourself Please consult the dealer when it comes time to discard this equipment Be sure that you are supplying the rated voltage Supply of an incorrect voltage may lead
11. TRIC LOS NAY screen at L Fonesony 1 T 3 1 UEHTI T VENT mo SBE LATION Locked sa Sat AUTO HEAT EX Past Indicator RA le gt OA ON OFF D MENU ON OFF 38 BACK MONITORISET DAY he FILTER PZ 60DR E CLOCK 15 Centrally Controlled CENTRAL will be displayed when operation is locked in the centralized controller or REMOTE is ON in Remote Input and also during the external interlocking priority mode during interlocking when the interlocking mode is External Signal Priority The following operations are locked e Clear Filter only when the operation is prohibited by the centralized controller e ON OFF including timer operation Note May also be individually restricted When interlocked with external device The Lossnay unit can be started and stopped by external equipment When the operation of Lossnay unit is started by external device INTERLOCKED is displayed on the remote controller display Timer mode is cancelled when the Lossnay unit is started by external device while the operation start timer has been set or when the Lossnay unit is stopped by external device while the operation stop timer has been set e External device interlocking is given priority over timer setting If delayed operation is set for the Lossnay unit the interlocking start time will be After 0 30 hours 2 Operation
12. at exchange By pass or automatic Fan Speed Adjustment button Used to select the fan of either Low or High Extra High MENU button CD ON OFF lt button MONITOR SET button lt ENTEP gt button MENU OON OFF 38 Press two times to reset the filter CLOCK button eH Dad sion diepla EA Back BACK MONITORISET DAY h CA Ahead PZ 60DR E CLOCK ON OFF button DAY button Extra Low fan speed button OPERATION button OPERATION button Selects Extra low fan speed operation C To preceding operation number CA To next operation number Opening the Note If you press a button for a feature that is not installed at the Lossnay unit the remote controller will display the NOT AVAILABLE message If you are using the remote controller to drive multiple Lossnay units this message will appear only if the feature is not present at the main unit BG Setting the Day of the Week and Time E Use this screen to change the current day of the week and time setting Note The day and time will not appear if clock use has been disabled or the simple timer has activated at Function Selection of remote controller Dot display 1 Day of the Week a
13. e a E When a 24 hour Ventilation setting is specified Extra low operation set by indicator is visible in the display at O pressing the ON OFF button while running when the timer expires the When something other than the Simple Timer is displayed set it to SIMPLE system will go to Extra low operation instead of stopping TIMER using the function selection of remote controller refer to section Note Installation Manual 5 Function selection 3 Mode selection 2 Timer function setting 1 Weekly inet imple Timer cannot be Used at the same time 2 Press the MENU button 49 so that the TIMER SET appears on the screen 2 The simple timer will not operate when any of the following conditions is in effect The timer is off the user is in the process of selecting a function the user is in Ser ad MER MONITORS the button toggles tie display benveen TIMER the process of setting the timer the system is under central control Under these 3 Press the ON OFF button to display the current ON or OFF simple timer conditions On Off operation is prohibited setting Press the button once to display the time remaining to ON and then 3 When using a simple timer the time will not be displayed on the screen even if again to display the time remaining to OFF The ON OFF indication appears at the clock use setting is ON use clock e ON timer The Lossnay unit
14. ght while the air conditioner is stopped to discharge accumulated heat and thereby reduce the air conditioning load the next morning If Night purge is enabled per the Installation Manual 5 Function Selection 5 8 night purge operation will be performed based on the flowchart shown at right From 1 00 A M to 6 00 A M Night Purge indicator is shown on the screen at H 1 2 WERT LATION BY PASS OA RA The fan speed will revert to the last setting before the Lossnay unit was stopped e Night purge operation is terminated in any of the following conditions C to and is not resumed until the start conditions of the next day are reached Between 6 00 and 0 59 When the operation is stopped between 1 00 and 6 00 with a deluxe remote controller or system controller When the operation is switched on or off between 1 00 and 6 00 by a scheduled timer Weekly timer When the operation is switched on or off between 1 00 and 6 00 by an air conditioner an external control input or a remote input Note Night purge can be performed when the clock use setting is ON use clock in Function Selection The Function Selector cannot be switched during Night purge operation Locked 2 will blink Night Purge cannot be used with the Simple timer Night purge settings can be checked in the Function Selection mode When more than o
15. hat the weekly timer indicator 1 is shown in the display Press the MENU button so that the TIMER SET appears on the screen at 2 Note that each press of the button toggles the display between TIMER SET and TIMER MONITOR Press the ON OFF DAY button to set the day Each press advances the display at 3 to the next setting in the following sequence SUN MON TUE WED THU FRI SAT gt SUN gt gt FRI gt SAT gt SUN MON TUE WED THU FRI SAT Press the V or A OPERATION buttons or 8 as necessary to select the appropriate operation number 1 to 8 4 Your inputs at Steps 3 and 4 will select one of the cells from the matrix illustrated below The remote controller display at left shows how the display would appear when setting Operation 1 for Sunday to the values indicated below Setup Matrix MONITORISET DAY D Op No Sunday e Saturday lt Operation 1 settings for Sunday gt Start the Lossnay unit at 9 00 with fan speed set to High lt Operation 2 settings for every day gt Turn off the Lossnay unit at 10 00 O Note 10 By setting the day to Sun Mon Tue Wed Thu Fri Sat you can set the same operation to be carried out at the same time every day Example Operation 2 above which i
16. he instructions If the instructions do not indicate limits use only at temperatures between 0 C and 40 C Use of this equipment at temperatures outside of this range may result in major equipment failure Do not use this equipment for purposes for which it was not intended This equipment is for use with Mitsubishi Building Air Control systems Please do not use it with any other systems or for any other purpose as such usage may result in improper operation Do not pull or twist the communication cables Pulling or twisting a cable may result in fire or equipment failure Do not disassemble Attempted disassembly may result in injury from contact with internal parts or may lead to fire or equipment failure Do not spray insect repellent or combustible substances on the equipment Keep combustible sprays and substances away from this equipment and never spray them directly onto this equipment Contact with or proximity to such substances poses risk of explosion or fire Do not use this equipment in improper environments Do not use in areas where there may be large quantities of oil machine oil etc exhaust gas or sulfide gas Such environments may degrade the performance or cause equipment failure Do not wipe this equipment with benzene paint thinner or chemical cleaning cloths These substances may cause discoloration or equipment failure If the equipment becomes noticeably dirt
17. mp as MITSUBISHI ELECTRIC LO NAY Time display hal QOwniorF oO MENU oNoEF 3 Fail o BACK MONITORISET DAY C gt FILTER PZ 60DR E CLOCK V OPERATION A CLEAR lt How to Set the Day of the Week and Time gt 3 Day of the Week Setting TT BET 4 Time Setting 1 Press the V or A CLOCK button to show display B 2 Press the ON OFF DAY button to set the day Each press advances the day shown at 3 SUN gt MON gt gt FRI gt SAT 3 Press the appropriate CLOCK button as necessary to set the time As you hold the button down the time at 4 will increment first in minute intervals then in 10 minute intervals and then in 1 hour intervals 4 After making the appropriate settings at Steps 2 and 3 press the lt 1 button to lock in the values Note Your new entries at Steps 2 and 3 will be cancelled if you press the BACK button before pressing the J button 5 Press the BACK button to complete the setting procedure This will return the display to the standard control screen where 1 will now show the newly set day and time To change the time or day of the week start from Step 1 above Note If you are using two remote controllers setting the time and day of the week in one remote controller will cause the new setting to be applied to the other as well 6 4 Using the Remote Controller_ Typical Sy
18. nd the operation will switch to Extra low fan speed mode To stop operation press the ON OFF button twice within 3 seconds or press and hold the ON OFF button for 5 seconds zB Pressing Function Selector button Ventilation mode Display AUTO HEAT EX lt Display will change gt AUTO 7 AUTO X automatically depending BY PASS 2 1 aoo X on environmental Y RACOMMENO EHTILATIOH Wa MOCE circumstances HEAT EX HEAT EX Be If either HEAT EX or BY PASS is selected and 1 and 2 blink alternately at an interval of five seconds in the dot display it is recommended to select AUTO The display blinks for a maximum of 10 minutes BY PASS BY PASS Vor aa Using the Timer This section explains how to set and use the timer You can use Function Selection of remote controller to select which of three types of timer to use Weekly timer Simple timer For information about how to set the Function Selection of remote controller refer to section Installation Manual item 5 3 2 Note e Weekly Timer and Simple Timer cannot be used at the same time If two remote controllers are connected to one machine or group and the timer is used set the timer only in one remote controller and set Timer disabled in the other The system will not operate correctly
19. ne Lossnay units are running the temperature is measured by the main Lossnay Night purge is not performed when CENTRAL is displayed Do not use the night purge function if fog or heavy rain is expected Rain water may enter the unit during the night 14 Night Purge mode is active no operation The outdoor temperature OA setting can be selected either 17 C or 28 C by using Dip Switch SW2 7 in the Lossnay control box Refer to the remote controller instillation manual for more information Outside temperature 17 C 28 C or more within 24 hours y Yes Temperature monitoring operation 5 minutes Yes Y y Night Purge operation By pass ventilation 55 minute stop Y No 6 00 A M Night Purge operating Finish Night Purge operation Stop Using the operation lock lt How to Lock the buttons gt Locking the remote controller buttons Operation Lock 1 While holding down the FILTER button press and hold down the ON OFF f you wish you can lock the remote controller buttons You can use the Function button for 2 seconds The Locked indication appears on the screen at M Selection of remote controller to select which type of lock to use For information indicating that the lock is now engaged about selecting the lock type see section Installation
20. peed at 7 setting Each press changes the setting in the following sequence No display no setting 5 To close the monitor and return to the standard control screen press the Extra High gt High Low gt Extra Low gt No display BACK button Note When not displayed the system will operate at the currently set fan speed other than Extra Low For the Lossnay models without extra low fan speed the speed will not be displayed lt To Turn Off the Weekly Timer gt 8 To clear the currently set values for the selected operation press and quickly release the Press the ON OFF button so that Timer Off indication appears at 0 CLEAR button 4 once The displayed time setting will change to and the On Off and fan speed settings TEF ENTI a 19 35 will all disappear To clear all weekly timer settings at once hold down the CLEAR HOE aesa Saas button 40 for two seconds or more The display will begin flashing indicating that all 10 OA RX in pP settings have been cleared 9 After making the appropriate settings at Steps 5 6 7 and 8 press the button to lt To Turn On the Weekly Timer gt lock in the values Press the ON OFF button so that the Timer Off indication at f0 TIMER SET indicator flashes three times goes dark Note Your new entries will be cancelled if you press the
21. s the same for all days of the week lt How to set the Weekly Timer gt lt How to View the Weekly Timer Settings gt Shows the time setting 5 Shows the selected operation ON or OFF 8 9 Timer Settings Does not appear if operation is not set Shows the fan speed setting 5 Press the appropriate CLOCK button as necessary to set the desired time at 5 1 Be sure that the weekly timer indicator is visible on the screen at U1 As you hold the button down the time first increments in minute intervals then in 2 Press the MENU button so that TIMER MONITOR is indicated 10 minute intervals and then in 1 hour intervals on the screen at 8 6 Press the 0 ON OFF button to select the desired operation ON or OFF at 6 3 Press the ON OFF DAY button as necessary to select the day Each press changes the next setting in the following sequence No display no setting you wish to view at 3 ON gt OFF 4 Press the V or A OPERATION buttons or as necessary to Note change the timer operation shown on the display at 9 The timer will not function when not displayed Each press will advance to the next timer operation in order of time 7 Press the Fan Speed Adjustment button to set the fan s
22. stem Setup In either case up to two remote controllers can be used Two remote controller operation When two individual remote controllers have been installed the most recent control signals will be given priority Independent operation of the Lossnay unit Lossnay N CEE SSsseo Remote controller s Up to two remote controllers can be used Power supply Interlocked operation with an air conditioners etc The Lossnay can al be controlled same zl Lossnay H Ssssesq as in independent L Remote controller s Lossnay operation Power Power supply supply L The Lossnay can Indoor unit Operation switch be started and for the external stopped via external Lossnay device equipment Power supply A maximun of up to 15 Lossnay units may be connected Dot display Function selector button aa MITSUBISHI ELECTRIC LOF NAY CENTRAL AUTO HEAT EX INTERLOCKED BY PASS p OA TIME SUN MON TUE WED THU FRI SAT FUNEHIO ier OOo ERROR CODE Boia ON CLEANING WEEKLY SIMPLE ON OFF button Fan Speed Adjustment button Extra Low fan speed button Operation Relevant button Relevant display items Sequence 1 Starting the Lossnay unit ON OFF P Bal
23. unning the timer value is visible on the display Be sure that the timer value is visible and appropriate 12 ES MENU ON OFF 38E hall lt Viewing the Current Simple Timer Settings gt 5 6 Timer Setting J Be sure that the simple timer indicator is visible on the screen at 1 2 Press the MENU button 42 so that the TIMER MONITOR appears on the screen at 5 If the ON or OFF simple timer is running the current timer value will appear at 6 If ON and OFF values have both been set the two values appear alternately 3 Press the BACK button to close the monitor display and return to the standard control screen mis lt To Turn Off the Simple Timer gt Press the ON OFF button so that the timer setting no longer appears on the screen at 7 age ENT LATION AUTO HEAT EX a iA oa 2X Ra i lt To Turn On the Simple Timer gt Press the ON OFF button so that the timer setting becomes visible at 7 AFTER Examples If ON and OFF times have both been set at the simple timer operation and display are as indicated
24. will start operation when the specified number of hours has elapsed OFF timer The Lossnay unit will stop operation when the specified number of hours has elapsed 4 With ON or OFF showing at B Press the appropriate CLOCK button 4 a4 MITSUBISHI ELECTRIC LOT NAY as necessary to set the hours to ON if ON is displayed or the hours to OFF if 7 OFF is displayed at TIMER SET p Available Range 1 to 72 hours ENTER PATER Pressing and holding the button will fast forward the display a 5 To set both the ON and OFF times repeat Steps 3 and 4 simpc gt 1 Note that ON and OFF times cannot be set to the same value QonioFF 6 To clear the current ON or OFF setting Display the ON or OFF setting see step 3 and then press the CLEAR button 40 so that the time setting clears to at 1 4 If you want to use only an ON setting or only an OFF setting be sure that the 2 setting you do not wish to use is shown as 7 After completing steps 3 to 6 above press the button to lock in the value 4 TIMER SET indicator flashes three times BACK MONTORSET DAY FILTER OO Note PZ 60DR E CLOCK V OPERATION A CLEAR Your new settings will be cancelled if you press the BACK button before pressing the button 8 Press the BACK button to return to the standard control screen 9 Press the ON OFF button to start the timer countdown When the timer is D r
25. y clean it with a wrung out cloth that has been moistened with water diluted neutral solvent and then wipe it with a dry cloth E c Parts Names Display Section For purposes of this explanation all parts of the display are shown as lit During actual operation only the relevant items will be lit Identifies the current operation Shows the operating mode etc Multilanguage display is supported Day of Week Shows the current day of the week TIME TIMER Display set Shows the current time unless the simple timer is If the simple timer is set shows the time remaining CENTRAL indicator FA MITSUBISHI ELECTRIC LO NAY Indicates that operation of the remote controller has been prohibited by a main controller INTERLOCKED indicator TIME SUN MON TUE WED THU FRI SAT TIMER FA i ZI EF Hr ON CLEANING AFTER CI 0 0 OFF ELTER ERROR CODE CENTRAL A INTERL QI SO aAuTO QWEEKLY Pal CORE SIMPLE Displayed when the Lossnay starts off by interlocked Lossnay unit or external signal in Timer Off indicator Indicates that the timer is off Night Purge indicator Displayed during Night Purge mode
26. ystem a MITSUBISHI ELECTRIC LOS NAY sx CHECK 5 i l ERROR CODE T Nl a a Aas ON OFF Fee PEDE _ Alternating Display M NET System aa MITSUBISHI ELECTRIC LOJ NAY CHECK Operation lamp Flashing Operation lamp Flashing ON OFF ERROR CODE Unit No Unit address No Alternating Display The contact telephone number will be displayed if CALL has been set Pressing the CLEAR button once will display the contact telephone number even when an error code is not displayed See the Installation Manual for the setup method f the Operation lamp and error code are both flashing This means that the Lossnay unit is out of order and operation has been stopped and cannot resume Take note of the indicated unit number and error code then switch off the power to the Lossnay unit and call your dealer or servicer 17 _ C Specifications Item Details Dimensions 120 H x 130 W x 19 D mm Weight 0 2 kg Power Source 10 to 15V DC Supplied from Lossnay unit Power Consumption 0 3 W Ambient Usage Environment 0 to 40 C 30 to 80 relative humidity Composition PS 18