1. Curve Type you can do the follows Oo Press the setup button of another module to store the selected Curve Type into the memory and go to the setup of the other module you can set there the PreHeat Leve first Press again the same setup button in this example the Module One to exit from the setup go back to the normal dimming mode and store the selected Curve Type into the memory 4 3 Testing the outputs TEST Mode To activate TEST function press the Test Chaser button 10 on the front panel After pressing it the level of the selected dimmer channel is going automatically from 0 to 100 Use the Up Down keys 8 9 to select another channel If the display indicates 00 all channels ate going from 0 to 100 By pressing the Test Chaser button 10 the dimmer goes to Chaser mode To exit from the Test Chaser mode press again the Test Chaser button 10 10 PLS Electronics Ltd 4 4 Chaser running CHASER Mode In this mode second pressing of the Test Chaser button 10 the dimmer can work in stand alone mode There are 3 fix level scenes 30 50 and 100 for all channels and 6 running scenes with adjustable speed When the dimmer is in this mode you can see on the display two digits like this The left one shows the speed of the chaser effect 1 means the fastest 9 the slowest speed You can adjust this with the Down button 8 below the display The digit on the right side shows the numbe
2. LR connector 13 120 Ohm DMX line termination switch Switch it to ON position only if this unit is the last on Figure 1 Handling units of front part the DMX line Otherwise left it in OFF position Pegasus Pro Series Dimmer Outlet of the backside connectors at Pro S Schuko Pro F French Belgian Pro C CEE16 3 Pro PC PowerCon and Pro WL Wieland ST17 dimmer 14 12 10 8 6 4 2 Mains CE 11 9 7 9 3 1 Figure 2 Back part connectors 1 12 Outputs of the channels from 1 to 12 13 3 x 40A input mains cable H07 rubber 5x6mm without CEE male plug 14 Analogue input via 15 pole SUB D male connector optional At B suffixed version of the Pro dimmer at this position you can find the XLR connectors for DMX Outlet of the backside connectors at Pro H2 dimmer 3 2 1 Figure 3 Back part connectors 1 Outputs for the channels 1 to 6 This connector referred in the future as Connector A 2 Outputs for the channels 7 to 12 This connector referred in the future as Connector B 3 Analogue input via 15 pole SUB D male connector optional At B suffixed version of the Pro dimmer at this position you can find the XLR connectors for DMX PLS Electronics Ltd 4 3 x 40A input mains cable H07 rubber 5x6mm without CEE male plug 5 Additional Protect Earth PE connection point for outputs with M4 nut The pin outlet the 16 pole Harting type connectors in normal H2 version is the follow
3. control is enabled the dimmer doesn t recetve any data from the DMX line and the display and the DMX LED are blank For the analog control cable use a 14 core wire with shield The cable will be the shortest as possible The connector type is the SUB D 15 pin female with house Pegasus Pro Series Dimmer 4 Digital Control 4 1 DMX input The DMX input signal must be connect to the DMX In 11 marked connector which can be found on the front side of the unit If this unit is the last one on the DMX network chain you must take the termination switch on the front panel to Term On position on the font panel Otherwise left it at the other position Pin 1 TL PM3 Pini Pin Function Pin 2 Pin 4 Number Pin 3 lt Pin 3 Pin 2 1 Ground Shield 2 Data 3 Data Pin 5 Pin1 pin2 4 Spare Data NC 3 Pin 4 Pin 2 5 S Data NC i pare Data a a Pin3 Pin 1 Table 1 Functions of XLR pins Figure 1 Outlet of the connectors front view the male connectors in the upper line The DMX input of the dimmer is power and opto isolated Not recommended to connect the Pin 1 to the Protect Earth PE The DMX Throughput is not isolated from the DMX input and not refreshed 4 1 1 Setting the DMX Start address The DMX start address can be select with two blue buttons on the front panel The left side button 8 is decrease the right one 9 is increase the DMX start address of t
4. egasus Pro 12 x 2 3KW dimmer Product model output variations sses S Schuko H1 24 pole Harting H2 2 x 16 pole Harting SX 2 x 19 pole Socapex C 12 x 3 pole 16A CEE Serial Number ou cccccescesssscscsecsssssssseeeees n a Lota Na aa te ert SCOR Te eT TECH Lg TNs Meer Aare ee n a Item number easoenoanenanenane nane nan anane nan anana One to which this declaration relates is in conformity with the following standards e EN 55015 1 Electromagnetic compatibility Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment CISPR 15 2000 CISPR 15 2000 A1 2001 CISPR 15 2000 A2 2003 using o IEC 61000 3 4 Technical report Limitation of emission of harmonic currents in low voltage power supply systems for equipment with rated current greater than 16A o EN 61000 3 11 Limitation of voltage changes voltage fluctuations and flicker in public low voltage supply systems for equipment with rated current up to 75A and subject to conditional connection e MSZ 2364 Electrical installations with a nominal voltage up to 1000 V Therefore the upper indicated product qualifies the EU 73 23 EWG LV directive and the 89 33 EWG EMC directive considering 93 465 EWG directive for CE Place of issue Signature of authorised person Szekesfehervar HUNGARY Date of issue 01 10 2006 Sandor Vass Director of PLS Ltd 12
5. erm On 3 Circuit breakers to protect the outputs 12 x 2 5KW Digital Dimmer Start Address Test Thru DMX In 4 These green LEDs show the control level of each Decrease channel 5 These yellow LEDs show the output level of each channel 6 DMX control LED If it s flashing the DMX AC Out o 1 PreHEAT pocket is correct when ON the dimmer is in Phase 3 Unit Test Chaser PreHeat or Curve setup mode AC Out when OFF the DMX pocket is incorrect not present or Analog control optional is on 7 DMX display Here you can see basically the start address of this apparatus on the DMX line 7 8 9 Down Up buttons With them you can set the DMX start address Test channel Chaser HAGER CI3A N 9 7 S Ba e Pre EAT 6 program PreHeat level or the Control curve AC Out Trig depends on the dimmer state HAGER CI3A 10 Test Chaser button If you push one time the selected channel of the dimmer is increasing automatically from 0 to 100 If the display indicates 007 all channels are go 0 to 100 HAGER C13A et CE HAGER CI3A By pressing this button again the dimmer goes to Chaser mode see later Push the Test button Phase 1 Unit again and the dimmer goes back to normal A ss e dimming operation 11 DMX input via male XLR connector HAGER CI3A 12 DMX throughput via female X
6. ft means the module number and the next two means the PreHeat Level in percent With the Up Down buttons 8 9 you can adjust the PreHeat Level from A 0 till 30 and meanwhile the outputs of the module go to Module PreHeat level No level the selected leve The factory setting is 0 in all modules After set of the PreHeat Level you can do the follows o Press the setup button of another module to store the selected PreHeat Level into the memory and go to the setup of the other module you can set there the PreHeat Level first also Oo Press again the same setup button in this example the Module One to go to the Curve Type select In this case the PreHeat Level is also stored into the memory Pegasus Pro Series Dimmer 4 2 2 Control Curve select After the second pressing of the setup button 2 of Module One you can see in the left position on the display the actual control curve of the module If you are at the setup of Module Two you can see the Curve Type in the middle position of the display at the Module Three in the right position Curve type The Curve Types ate the follows 1 Bright Linear output 2 Voltage Level Linear Phase Linear 3 Switch ON OFF Relay function DMX 0 127 the channel is OFF DMxX 128 255 the channel in ON The factory setting is Bright Linear 1 in all modules With the Up Down buttons 8 9 you can select the requested Curve Type After select of the
7. he dimmer If you hold down one of the buttons the address is increment decrement automatically After the last button press the dimmer saves the selected address within 5 seconds The saving is indicated with a three times flash of the display no dimming while saving On the next power on the saved DMX address will restore 4 2 Control setup of each dimmer module Below each power indicator LEDs 1A B and C you can find a button 2A 2B and 2C By pressing one of these buttons the dimmer goes into the setup of the corresponding module In this setup you can adjust the PreHeat Level and select the Control Curve Type for the module each channel on the module will have the same preheat level and control curve The incoming DMX signal has no affect to the output while the dimmer is in the setup and the DMX LED is ON PLS Electronics Ltd Menu structure of Pro dimmer Normal Dimming State PreHea adj Channel Test y ro Chaser Running Setup of Module 1 L1 2A Setup button of Module 1 2B Setup button of Module 2 2C Setup button of Module 3 10 Test Chaser button Setup of Module 3 L3 Setup of Module 2 L2 4 2 1 PreHeat Level adjust After pressing e g the setup button 2A of Module One CH1 to 4 you can see similar on the display of the dimmer It means the PreHeat Level of the Module One is 25 The first digit from the le
8. mmer 4 3 x 40A input mains cable H07 rubber 5x6mm without CEE male plug 5 Additional Protect Earth PE connection point for outputs with M4 nut The pin outlet the 19 pole Socapex type connectors is the follows Pin number Function Output phases for channel 1 2 3 4 5 6 respectively at Connector A 1 3 5 7 9 11 and output phases for channel 7 8 9 10 11 12 respectively on the Connector B Output neutrals for channel 1 2 3 4 5 6 respectively at Connector A 2 4 6 8 10 12 and output neutrals for channel 7 8 9 10 11 12 respectively on the Connector B 13 14 15 16 17 18 19 PROTECTIVE EARTH PE 2 Installation of the unit After unpacking the apparatus is ready for use Not to make the cable longer If it is short use standard extension Operating with injured cable is perilous CAUTION The apparatus is NOT waterproof Protect from several liquids Not to use outdoors without appropriate preventive measures If water or other liquid getting into it dry up and take to technician Working with wet apparatus is PERILOUS The unit has been shipped with 5x6mm H07 rubber cable without CEE male plug The correct order of the power cable is the follows Cable color Function Grey Line 1 L1 or R Black Line 2 L2 or S Brown Line 3 L3 or T Blue NEUTRAL N Green Yellow Protect Earth PE PLS Electronics Ltd CAUTION The manufacturer doesn t re
9. r of the selected Chaser effect 1 2 and 3 are fix scenes 4 9 are running scenes You can select the Chasers with the Up button 9 below the display Speed Chaser No To go back the normal operation dimming mode press again the Test Chaser button 6 Technical information Power supply sssini 3 x 40A 3 x 230V AC 10 three phase Power draw with open Outputs eee 10W Output CORE CHORES siyohesiancs aitraetesinanes aitemsadeleons 12 x Schuko S 2x 16 pole Harting F H2 2x 19 pole Socapex SX 12 x CEE16 3P C 12 x Neutrik PowerCon 16A PC Input ONC CLOLS assia 15 pin SUB D male opt and 5 pole XLR male Noise TIME LS suasana aa aaa ag aa eag aa an aga a e awa aa Hypersil HF filters at all ch 200uS 15 delay Output PESTS CHOI irasan C13 Amps circuit breakers Hager Input PEOT GHOR srinata cnsseweniscresvinsacnewniciseninnetieniye Zener diodes TVS and opto and power iso lation on DMX input the throughput is not isolated and refreshed Operating temperature 00000000e 000 anana naee 10 C to 40 C Storage temperature c0000e000 eaaa anana anane 10 C to 60 C Dimensi ns snaois degag aa Da pa ag 484 x 132 x 350 connectors BG nan a AAN E NA AN ai 18Kg 11 Pegasus Pro Series Dimmer Declaration of Conformity We PLS Electronics Limited declare under sole responsibility that the product Product ARE ba sasasi gi san abang patanen ha aa paek P
10. s Pin number Function Output phases for channel 1 2 3 4 5 6 respectively at Connector A 1 2 3 4 5 6 and output phases for channel 7 8 9 10 11 12 respectively on the Connector B Output neutrals for channel 1 2 3 4 5 6 respectively at Connector A 9 10 11 12 13 14 and output neutrals for channel 7 8 9 10 11 12 respectively on the Connector B 7 8 15 16 and the PROTECTIVE EARTH PE side connectors The pin outlet of the 16 pole Harting type connectors in H2 D version is the follows Pin number Function Output phases for channel 1 2 3 4 5 6 respectively at Connector A 1 3 5 7 9 11 and output phases for channel 7 8 9 10 11 12 respectively on the Connector B Output neutrals for channel 1 2 3 4 5 6 respectively at Connector A 2 4 6 8 10 12 and output neutrals for channel 7 8 9 10 11 12 respectively on the Connector B 13 14 15 16 and PROTECTIVE EARTH PE the side connectors Outlet of the backside connectors at Pro SX dimmer 3 2 4 Figure 4 Back part connectors 1 Outputs for the channels 1 to 6 This connector referred in the future as Connector A 2 Outputs for the channels 7 to 12 This connector referred in the future as Connector B 3 Analogue input via 15 pole SUB D male connector optional At B suffixed version of the Pro dimmer at this position you can find the XLR connectors for DMX Pegasus Pro Series Di
11. sponsible if the customer connect the cable wrongly The guaranty will be void if the connection order is 4 wrong and the unit can be damage too N Before power up always control the right connection of the Lines Neutral and the Protect Earth The unit is able to control 12 x 10Amps The input L1 L2 and L3 lines are connected to the channels as the follow 1 4 channel to Phase L1 5 8 channel to Phase L2 9 12 channel to Phase L3 You can use the unit from two or one phase too for example the L1 and L2 are the same phase If change the numbers of phases the maximum output power is change like this At 3 phases 3 x 40Amps at 2 phases 2 x 40Amps at 1 phase 1 x 40Amps These are the absolute maximum ratings IN If you overdrive the dimmer can be DAMAGE IN 3 Analog control optional The functions of the SUB D connector pins are in the following table The Pin 13 is a fix 10V Ioyax 50mA output Pin N Function Vikt ied i 1 12 1 12 Channel IN ith this output and twelve potmetets you can make a 13 FIX 10V Output very simple control board to this dimmer The control Analog mode enable input d connect it to GND board doesn t need any other power supply Use 10K to 15 GND 100K Linear type potmeters If you don t want to use pin 13 leave it UNCONNECTED The pin 14 must be connected to GND to enable the analog control Just connect the pin 14 to the pin 15 While the analog
12. w kala JEN ELECTRONICS p Theatre amp Stage Technology Pegasus Pro series 12 x 2 5 KW Digital Dimmer User s manual Fifth edition Copyright 2008 Pegasus Pro Series Dimmer Dear Customer Thank you for chose PLS Electronics product Please read this manual carefully If you have any technical question or you looking for other equipments don t hesitate to take up the contact with our sales representative or with the manufacturer at the www pls hu web site This apparatus is a twelve channel digital dimmer with DMX 512 1990 or 0 10V control optional with additional control possibilities The light control is produced by a phase angle control system on the neutral The wrapper of the unit is NOT baby to therefore keep it away form babies For technical questions and original spare parts please take up the contact with our sales representative or with the manufacturer at the A www pls hu web site A ATTENTION Nei USE WITHOUT PROTECTIVE GROUND N Not allowed to make a parallel connection between any outputs phases or neutrals of the unit Otherwise the unit can be damaged 2C 1C 2B 1B 2A PLS Electronics Ltd Front parts 1A B C Phase Module state indicators If it s ON the corresponding phase unit is working 2A B C PreHeat Curve setup button of Module 1 2 WENG a Increase Pegasus E and 3 See the operation later T