1. E UJ eee ERI H mum d 4 mam e Oy m Cima B ii bg 10 D mid CHEME E aea Vi Ek E E E S BD Jemen aaa RA AeA na 1G E d usmam oe Oh Fee 1 Delete all delete all reservation contents from Monday to Sunday Delete day delete all reservation contents on selected day Selective delete delete the selected individual item from the reservation list Select all select all items on selected day Clear all cancel all selected items Copy day copy the selected day to memory Selective copy copy selected contents to memory gt Paste add the copied contents in the memory to the list Save save the setting Close close the reservation setting list Holiday management manage the holiday list Broadcasting will not be on in the holiday gt Reservation name insert the name to be saved 3 Add add the selected date to the
2. 43 nos Mice DHAN Local zone connected in sound source number 1 channel and output number 1 Client screen configuration will be composited differently in accordance with user authority The reason consisting the screen as shown above are as follows 1 Connected user authority is User 2 Sound source selection of connected user authority is set as MIC 3 Output selection of connected user authority is set as Output 1 Refer to Configuration gt Input Output output setup Page 23 Zone connected to Ch number 1 sound source and output 1 can be controlled 5 6800 76 MANAGEMENT SOFTWARE 3 If User Authority is Guest 3 Authority Setup Setup the user account in MS 6800server gt Configuration gt ID PW 1 User Authority Guest 2 Sound source selection ALL select entire sound sources 3 Output selection ALL select system entire zones Guest authority can only do monitoring A MS 6800 Client Connection inter System LOGIN IF 192 1683 28 99 Port 4100 questi 1 Password Connect Close Connect with guest01 which has the manager authority IP insert the IP address of MS 6800 server program 77 5 6800 MANAGEMENT SOFTWARE 6 Port insert the port of server program Default 4100 7 ID insert the user name 8 Password insert the user password Case sens
3. 23 24 EE 25 A Other Settings s iniissscsissscdovssensisnedeavieiavshunshsavacsssbaosbaosvasdanasondasadnnndamuesionmuenonnadssstersdescdedacnnasas 26 3 ze Uo HEN ITO TOTO LODS 27 27 Setup Settings Equipment of PD 6359 6207 SC 6224 6218 27 29 3 Lone Ge OC TNL 30 ZN BEI I ES eee E 2l RIVA SING eer E E AE 32 33 7 Common Contact Point Macro Seting 34 9 9 Sound Source 00 0 0 0 00 00 36 MANAGEMENT SOFTWARE A 37 E E 39 e E E E EEE 40 Using MS 6800 Program Server Foren FUN ONE eera TTE 44 2 Conirol Sound SON EOS 44 47 48 48 Sound 49 49 TUNER Controlling RO RE 49 BIDE CI CONTO 49 PC MP3 49 o Colo Bre COIS FING 52 1 Select Sound Source 52 53 3 Select a 53 4 MIXING Volume 55 5 Zone Selecting
4. 5 6800 72 MANAGEMENT SOFTWARE Example of User Screen depending on User Authority l If User authority is Manager 1 Setup Authority Lice HDD InpulSeurce El Setup the user account MS 6800server gt Configuration gt ID PW 1 User authority Manager 2 Select sound source ALL Select all sound sources 3 Select output ALL Select system all zones 2 MS 6800 Client Connection System LOGIN 132 168 48 99 Port 4100 angel 1004 Connect Connect with angel 1004 which has manager authority 1 IP insert the IP address of MS 6800 server program 73 5 6800 MANAGEMENT SOFTWARE 2 Port insert the port of server program Default 4100 3 ID INSERT THE USER NAME 4 Password insert the user password Case sensitivity 5 Click the connection button If connection is success below screen will pop up ier MESES Rernzte Conir Wer j WAT pd coli All sound sources and zones will be displayed Client screen configuration will be composited differently in accordance with user authority The reason consisting the screen as shown above are as follows 1 Connected user authority is Manager 2 Sound source selection of connected user authority is set as All 3 Output selection of connected user authority
5. currently broadcasted volume is activated volume can be controlled individually 55 5 6800 MANAGEMENT SOFTWARE PX 6216 Volume consists of as below 1 1 MIXING a 6 o eo 4 6 E o tn ii o o o o 6 o e 6 w o o System Volume Block Diagram INPUT Volume controls the input volume of PX 621 6 Refer to sound source control gt Input volume MIXING Volume controls the mixing volume of PX 621 6 Refer to MIXING EQ Volume controls the EQ of PX 6216 Refer to sound source control gt EQ OUTPUT Volume controls the output volume of PX 621 6 Refer to sound source control gt output Volume Output Volume controls can control the MIXING EQ OUTPUT Volume for each channel 8 channels MS 6800 56 MANAGEMENT SOFTWARE 5 Select Zone Broadcasting Select the sound source to be broadcasted B Selected sound source icon will be changed as below C When selecting the macro functions 2 or more sound sources can be selected with one button in accordance with the rule stipulated in the sound source macro page in the configuration menu Source che chin gt Refer to Configuration gt sound source macro setting Select the zone to be broadcasted D Each zone can be selected directly and already set group c
6. 1015 DO Mri 3 PX 6216 verzon Popa ea ee 11 4218 Vei 2 4515 A D 4174 rl n E m in 9 PB LIz7 m wl buid doie 21 2012 09 21 45 5 6800 44 MANAGEMENT SOFTWARE 3 Sound source screen 1 Sound source to be broadcasted can be selected sound source can be set in Configuration gt Source 2 When selecting the macro sound source can be selected by using the macro set in the configuration 4 Status Display Icon 1 Lock If lock function is used only monitoring is possible and control will not be impossible Can be set and cancelled by inserting ID PW 2 Communication Display the serial port connection status between PC and DIB Green for normal and red for communication failure Caution communication will not be available if USB serial port is connected after removing it In this case USB connection should be checked If it is connected text will disappear automatically 3 Remote Display whether client is connected or not Green for normal and red for communication failure client is connected Cx client is not connected If Remote is clicked currently connected clients will be displayed Forced termination clear the client connection by force 5 Display Server Status SERVER means the server PC program which controls by connecting
7. DIB 6000 Refer to Program Manual for detail information Server Program Configurations gt Setting Communication Port Refer to Page 22 Client Program Starting Client Program Refer to Page 65 13 5 6800 MANAGEMENT SOFTWARE Installing Programs and Hardware Caution when Installing Programs Windows 7 Control setting level of user account should be lowered before installing on Windows 7 If not some parts of program will not be installed so problem may occur After installing restore the setting level How to Copy the Setting Information to other PC If PC is replaced with other PC copy entire INT folders then paste it in the same location of newly installed PC Location C Program Files Inter M MS 6800 SERVER INI amp Basic Items 1 How to Change the Control Setting of User Account Windows7 1 Select Start Control Panel User Account and Change User Account Control Setting Le Loren aed A Lr Ear Leonid Pye Flex Bitte Comets g Fig profin properties D bakia ierra taedet 5 6800 14 MANAGEMENT SOFTWARE 2 Change the setting level to Not inform Restart the PC Choose when to be notified about changes to your computer Use Accourst Contro
8. 57 6 Presel Seleciinc 58 A AE 58 8l Broadoasling 59 2 Power SUPPE 59 10 Emergency 1 2 2101 59 11 Equipment Monitoring PD 6359 PB 6207 SC 6224 6214 59 MS 6800 Program Help sse 64 Using MS 6800 Program Client 2222 2 2221112 65 Install Client Programs nnnm 65 Staring Client Programs 69 eco REED MEMINI 69 2 e 70 Additional 5 1 Connect a MIC to Client PC and Check the Setting 72 Example of User Screen Configurations depending on User 73 1 If user authority is Manager 73 2 If user 75 3 If user authority is CIL MT 77 MANAGEMENT SOFTWARE Features 1 Control the system with PC Windows Programs OS Win XP Win 7 Common PC configuration 1 Monitoring all zone broadcasting status Max 160 Zone RS 485 communication 2 16x8 Audio Matrix System that 8 unification simultaneous broadcastings are possible 3 Volume contr
9. 5 Save save the setting value 6 Normal contact point macro setup the normal contact point mode Refer to detail manual of Normal contact point macro From above figure contact point setting is operated as Normal Mode and if input is on in number 1 input sensor it is operated as Normal contact point macro number 1 Broadcast the Normal contact point macro number 1 CDP sound source in below figure to all 1st grade classes 7 Normal contact point macro setup the normal contact point mode operation method 1 Select select the normal contact point number 2 Select sound source select the sound source to be broadcasted 3 Select group select the group zone set in the group will be selected 4 Select zone Select the zone 5 A B display the zone name A Zonel Zone80 B Zone81 Zone160 6 Select all select all zones 7 Clear clear all zones selected 8 Save save the setting values 9 Close close the normal contact point setting window If output zone is changed in equipment input output setting zone setting should be redone 5 6800 34 MANAGEMENT SOFTWARE 8 EP Timer setting setup the broadcasting zone with EP Timer 1 Select select the operation method EP MIC MIC operation of EP TIMER operate with timer PW 6242A mode EP MIC select the broadcasting zone when EP mode occurs TIMER select the broadcasting zone w
10. a p ERE m m a EXE a T LL ESS 0 IL 117 1 Ps Fh eS 1001 00 EM d i 1 Changing zone name double click the zone name and insert the name 2 Changing zone name position left click the mouse on the zone name area to be moved and unclick on the zone name area at the destination Ex Click and hold the Class1 grade 2 and move the move to the Class 8 grade 1 and unclick the mouse 3 Save save the setting value MS 6800 30 MANAGEMENT SOFTWARE 4 Group setting select the zone area and setup the group a y ps pec CUM U Y 8 1 Select group select group name square area in the group selection Currently selected group name 2 Input label input the group name selected in the group selection 3 Input setup the group name 4 Delete delete the group 5 Select zone select the zone icons will be displayed on the selected zone 6 A B displays the zone name and list A Zonel Zone80 B Zone81 1 60 7 Save setting save the setting value n the above figure group setting sets the 1st grade group from class 1 1st grade to class 9 1st grade If output zone is changed in the equipment input output set
11. Chi the che chio T e 2 Push and select Several sound sources be selected 2 Macro sound source displays the macro input source 3 Check macro Radio Button to activate the macro button keane thi chs che cha cha che chin Select 4 Macro Refer to Configuration gt sound source macro 5 6800 52 MANAGEMENT SOFTWARE 2 Select group broadcasting zone can be set in the group 3 Select zone broadcasting zone can be selected with individual and Select al Set in the add edit and delete setting part about the group Refer to Configuration gt Group Setting 1 Group Selected status If zone name is long will be displayed after max 8 digits fone 9 Te fone Zone fone 49 orne SF 53 5 6800 Zone zone 10 Zone 11 CERTES fone 18 fone 19 fore 50 Zones Sl Zore Zone 17 Zone 20 Zone 28 Zone 36 Zones fone fone 13 ee ee ee ee ee Zone 29 Zone 459 Group Not Selected status Zona Zone 14 Zone 18 Zone 18 a a m Zones 23 Zones 224 LI Zone 30 2 Z
12. Broadcasting Start After selecting the zone to be broadcasted and push the start button to broadcast 11 Broadcasting Finish Select the zone being broadcasted and push the broadcasting finish button 15 Zone Selection Screen Broadcasting zone can be selected individually Entire zones can be selected cleared 16 Minimize and finish minimize the program finish the program Operation method for the client is same as MS 6800 server program method and refers to server program for detail information MS 6800 MANAGEMENT SOFTWARE Additional Items 1 Connect PC MIC to Client PC and Check Setup Status Before using PC MIC in client PC check the MIC connection and status If setup is wrong MIC will not be output lt XP gt Push Volume button on the audio sound record to select the Record Control setting to MIC and adjust the MIC level Esap Likt lt WIN7 gt 1 Select the Record menu on above screen and set MIC as default device Select Level menu and adjust the MIC and MIC amplify level E hicrphone Proper Payback hoonds Genes Leten LEME Advanced baxt a Scceding deen below readily 1 Speech Disable Bori ii Ll 10 5 dB Zl y Show Dizabied Dese Show Demone Desires Set Properties
13. Audio Terminal LINE IN LINE OUT MIC IN For Client PC only MIC IN terminal is used DD 250G or higher PC Type Desktop x Caution 1 Do not use on the PC which operates Virtual XP on Windows 7 2 Refer to Control Panel System information for Windows operations 3 MS 6800 MANAGEMENT SOFTWARE Equipment Setting 1 Setup the Equipment Number If equipment number is changed during program is operated program should be re executed 1 PX 6216 PX 6216 does not need to set up additional ID 2 ECS 6216MS ADDRESS ON 12345678910 A Setup the equipment number accordance with wiring conditions by using the rear panel DIP switch One PX 6216 is used in entire system and ECS 6216MS is used if it is expanded C ON switch number will be the equipment number as shown in above dq d d 2 5 c 1T ICI 3 67 596 10 ECS 6216MS connected Caution if equipment number is set zone display LED will blink If equipment numbers are overlapped communication will not be available In above cases check the equipment number setting D Zone allocations of set equipment are as follows However if 9 10 switches are ON in a same time and power is supplied equipment will be on Manual Relay Control Mode It can be used for track inspections when constructi
14. acre quum l Toma mw ros 2 Prya Cedi frees 5 6800 64 MANAGEMENT SOFTWARE Using MS 6800 Program Client Installing Client Programs 1 Execute the MS 6800 CLIENT SETUP 1 0 0 0 of provided Set up CD Below screen will pop up and click Install button Caution if Visual C Runtime Libraries x86 is installed below screen will not pop up In this case it will be started from step 2 The timg components wil be on your machine Do veu wish 10 install these components you choses Lance setup wil eur o 2 Language installation screen Click Next button fe 5 5800 Welcome to the M5 6800 CLIENT 1 0 0 3 Setup Wizard 65 5 6800 A Final user right contract screen Check Agreed and click Next button End User License Agreement dpi the Inter M is an agreement between e user to use this software legitimately you can download In addition the backup or you can make a copy for MS 6800 66 6 Preparation screen for installation Click Install button Ready to install MS 6800 CLIENT 1 0 0 3 MS 6800 MANAGEMENT SOFTWARE 8 Installation completing screen Click Finish button Restart the system if installa
15. computer Operate the 6 buttons of PX 6126 front by mapping to Preset Preset6 buttons of the program PX 6216 Front fi Marret piru E MS 6800 58 MANAGEMENT SOFTWARE 8 Broadcasting Status display the current broadcasting status of PX 6216 output channel Broad 1 casting s i 1 displays that emergency broadcasting mode is broadcasted 2 EM displays that it is broadcasted with emergency broadcasting mode or Input Sensor contact point mode 3 TIME displays that it is broadcasted with scheduling mode 4 RM1 displays that it is broadcasted with remote mode 5 RM2 displays that it is broadcasted with remote MIC2 mode 6 RM3 displays that it is broadcasted with remote MIC3 mode 7 RMA displays that it is broadcasted with remote MICA mode 8 BGM displays that it is broadcasted with BGM mode 9 SR displays that it is broadcasted with SR mode 9 Power Supplier controls PD DC power POWER Power on T ERR pur RP Power Power always on only PD 6359 10 Emergency Broadcasting manually start the broadcasting with emergency mode A x Only administrator can change the emergency broadcasting mode change the selected zone to normal broadcasting mode change the selected zone to PC emergency broadcasting mode 11 Monitoring
16. if data number of ON switch is added it will be the equipment number Address when turn on number 1 and 3 equipment number will be 5 by adding 1 and 4 which is actual number Refer to RM 6024 Manual for detail information 4 PD 6359 PB 6207 AFD 6218 ADDRESS OFF ON 12 4 8 16 A Setup the equipment number in accordance with connecting condition by using rear panel DIP B Error may occur if same numbers are overlapped in the system C Setting method is as table below and number of ON switch will be the equipment number Max 20 can be expanded for each Address Ex Equipment number will be 5 by adding 1 and 4 which is the real number when number 1 and 3 is ON MS 6800 6 MANAGEMENT SOFTWARE 5 SC 6224 ADDRESS _ A Setup the equipment number in accordance with connecting condition by using rear panel DIP B Error may occur if same numbers are overlapped in the system C Setting method is as table below and number of ON switch will be the equipment number Max 12 can be expanded for each Address Ex Equipment number will be 5 by adding 1 and 4 which is the real number when number 1 and 3 is ON 2 TERMINATION Switch LOAD OPEN Setting General TERM LOAD 1 For RS 485 communication Termination switch setting Load Open on the rear panel is required to prevent the external nois
17. list Delete delete the selected list item Close close Load Save window 5 6800 42 MANAGEMENT SOFTWARE Forced termination terminate the scheduler broadcasting by force Set PC scheduler use Item that sets whether scheduling functions will be used or not Default use reservation functions External Timer _ PC Use outside scheduler use the outside scheduler functions PW 6242A unit interlocking Use PC scheduler use the PC scheduling functions Reservation setting save button Save the setting Caution alter setting if Save reservation setting button is not clicked setting will not be saved Push this button if setting is completed 43 5 6800 MANAGEMENT SOFTWARE Use MS 6800 Program Server Operation Mode 1 Screen Functions i 1 Adjust sound sources Divided into input of sound source Volume output Volume output EQ and Digi Link control 2 Display MS 6800 program version and user name IF MS 6800 version Ver 1 1 2 0 is clicked PX 6216 ECS 6216MS and Monitoring Device versions can be confirmed as below 20M Wend 10 16 Pe PT PET ee 2 eh 218 FS D eel 3 OCS Var 10 15 4 5 ert 8 15 5 7T er 15 sii Bub 14 15 MUUH NI wert
18. log status on selected date 1 2 Display the today s log status 2 3 Log Date select the log date 3 4 Automatic deletion setup the log file deletion period 4 Deletion cycles Naver Not delete 3 month 6 month 9 month 12 month 25 5 6800 MANAGEMENT SOFTWARE 4 Extra setting setup the other information of the system 1 User name insert the user name 2 PD on Time setup the PD on time before schedule is broadcasted Default value 10 PD Power Distributor equipment 3 BGM priority broadcasting select the BGM source unit broadcasting methods broadcasting by priorities it broadcasts the high priority broadcasting Broadcasting by mixing it broadcasts by sound source mixing regardless of priorities Refer to equipment setup gt Input setup 4 Broadcasting now it is the setting which broadcasts right away even if Start Broadcasting button is not pushed for the broadcasting through group selection select all and preset setting MS 6800 26 MANAGEMENT SOFTWARE 3 Equipment Setting 1 Input Setting setup the values on PX 6216 audio input channel Chl Ch10 999999 9 m a 1 Lege i I Bc aga boim 5 a 1 d DLL aud LEi 1 HD uper Input source setting displays 10 channel lists to the lateral direction
19. or you can make a copy for 5 6800 Choose Setup Type Choose the Eb Gest gus your reps most common program features Recommended for most users Alkywis users ta chaose which orogram features wil be installed and where they wil be nstaliec Recommended for advanced users Compete program eatures wil be installed Requires the most disk space zach Cancel 17 5 6800 6 Preparation screen for installation Click Install button 5 6800 1 1 Ready to install MS 6600 SERVER 1 1 1 7 Chck Install begin the instalation Chck Back review or change any of your nstelisbon settings Click Carce to the wizard 7 Installing screen Wait until installation is finished 5 6800 1 1 Installing M5 6800 SERVER 1 1 1 7 Pee while fe Setuo Ward PS ESOC SERVER 1 1 1 7 Status MANAGEMENT SOFTWARE MS 6800 18 MANAGEMENT SOFTWARE 8 USB driver installation screen Click Install button to start the installation Caution if USB driver is already installed below screen will not pop up In this case step 8 and 9 will be omitted Installing M5 6800 SERVER 1 1 1 7 Pees wait while the Setup Ward MS ES3DO SERVER 1 1 1 7 Siron Laooratones Sheen Laboratories C9210x USB to UART Bridge 9 USB driver installation completing screen Click Confirm button Cautio
20. 0 MANAGEMENT SOFTWARE DECK control controls the deck which is audio input unit lf ens L Channel of deck registered as the source unit can be selected 2 Displays the playing status of deck DECK control buttons play forward stop and backward PC MP3 Control controls the play of MP3 file 1 Sound source select and server sync button i Click 3 button then window which can select file will be opened 5 6800 50 MANAGEMENT SOFTWARE File Hama Flay Time CHIMES MPS MPS 2 MPS CHIMES MPS CHIME4 CHIMES CHIME6 MPS CHIME Add sound source can be registered Delete delete the sound source registered Setup setup the sound which plays the selected file e Close close the window ii When it is in client mode it syncs with server 2 Displays the name of file and playing time 8 Sound source control buttons of PC forward play pause stop and backward buttons ST 5 6800 MANAGEMENT SOFTWARE 3 Controlling Broadcast 35 id Jone 64 1 Select sound source select the sound source to be broadcasted 1 Normal sound source displays the audio input source inputted in PX 6216 Input Channel Ch1 Ch10 Source chi
21. 5 6800 MANAGEMENT SOFTWARE File No setup the audio file number to be broadcasted after Input sensor occurs Audio file number of PV 6232 Refer to PV 6232 User Manual for detail information Group zone can be selected with group button Zone set in the group will be selected Zone Select the zone to be broadcasted Add add the set values in scenario list Delete delete the selected item from scenario list Change change the setting value Save save the setting values Close close the scenario setting window If output zone is changed in equipment input output setting zone setting should be redone 2 Special scenario setup the special scenario f Special scenario button is clicked special scenario setting window will be activated Setting method is same as the normal scenario setting Special scenario it means that 2 or more sensor inputs occur If one sensor input occurs it is operated with normal scenario mode If additional one sensor input occur in the normal scenario mode it will be operated as the special scenario mode If sensor inputs are more than 2 special scenario mode Also if only one sensor input is caused in the special scenario mode it will be operated as the normal scenario mode again and if there is no sensor input it terminates the scenario 3 All contact points off reset all contact point signals Use it is the button to turn off in case of wron
22. 6 5 6216 5 Address 2 17 32 ECS 6216MS Address 10 Zone No 144 160 MS 6800 10 MANAGEMENT SOFTWARE 4 PV 6232 EP 6216 Connection Diagram AC INPUT FUSE PV 6232 EP 6216 e e 2 2 2 CH7 6216 g QU CH8 QU CH7 Q9 CH6 QU CH5 QU CH4 CH3 D D gt gt gt gt ENENEN Audio Line Ms Data Line 11 5 6800 PRE IN REMOTE IN 2 REMOTE IN 1 TIMER IN 9 4 21 www inter m com MADE IN KOREA IREN VOLI l D 27 S 41200 MANAGEMENT SOFTWARE 5 Relationship of PX 6216 RM 6024 TP 6231 RME 6108 1 Equipment numbers set in RM 6024 should be connected in accordance with port numbers of RME 6108 2 If one of below condition is not matched fault LED will be on RMs connected to the RME PX 6216 Wiring RME 6108 Port Wiring RM 6024 RM Input Port CATS OUTPUT Port INPUT Port CAT5 Equipment Number RMI OUTPUT RM2 c OUTPUT RM3 e gt OUTPUT RM4 OUTPUT RMEA RM8 lt 5 6800 12 NE OS Qi amp IN a Qs I CO NM MANAGEMENT SOFTWARE 6 Connecting to CLIENT PC System can be controlled remotely through server PC on the Client PC Setting cannot be changed and only source units and PC MIC controls are available Server PC Client PC
23. Making Communication Cables Connect all terminals connected to RS 485 communication by using CATS line as below VIEW FRONT VIEW 1 TA Brown 6 Green 5 J Areen 2 Orange 1 M IOrange iy 12345678 x Caution 1 When making the CATS CABLE match the color orders as direct type 2 Specially colors and orders should be matched for DATA line because it uses twisted lines 2 Method to Connect RS 485 Communication Line and Communication Distance Equipment can be connected through LINK IN OUT within distance of 1Km Caution 1 Setup the termination switch on the equipment rear for wirings Refer to Page 8 2 Use the CATS line which resistance is less than 200 ohm based on 1km Communication may be unstable or unavailable as line resistance is getting bigger 9 5 6800 MANAGEMENT SOFTWARE 3 Expanding the Zone through ECS 6216MS Link 1 PX 6216 has no equipment number and only 1 can be used for the system 2 Zone expansion uses ECS 621 6MS Max 10eq PX 6216 9990 0 om we o s Address 1 No 1 1
24. Monitoring the Status of the PD 6359 PB 6207 5 6224 AFD 6214 Monitoring les Bs 8 59 MS 6800 MANAGEMENT SOFTWARE 1 PD 6359 Monitoring the Status of PD6359 Power Distributor If PD button is pushed below screen will be displayed Fear p Communication Status and Equipment Name Display 2 Display Charging Voltage Current Display the battery charging voltage and current GREEN normal RED unable to communicate Setup of Equipment can be changed in the Configuration setting gt input 2 Display Charging Voltage Current Display the battery charging voltage and current POWER Button It displays the status with colors of power ON OFF button for each equipment Gray OFF status Red ON status Orange ON status but unable to ON OFF To control it on the program while front power switch of PD is ON it should be OFF Name Input the name of PD 6359 Enter Apply the name of PD 6359 Channel Name Changes If you want to select the channel name to be typed directly current channel will be displayed on below screen Type the channel name you want then push Enter button SAVE will save the changed status If Close button is pushed the screen will be closed MS 6800 60 MANAGEMENT SOFTWARE 2 PB 6207 Monitoring the status of PB 6207 Battery Charger If PB button is pushed below screen will be displa
25. Password insert the password 4 Confirm the PW re insert the PW 5 Authority setup the user authority 6 Select sound source setup the authority about sound sources 7 Select output setup the authority about output selections 8 Add ID add the currently inserted account 9 Delete ID delete the currently inserted ID 10 Modify save the modified information 11 Save setting save the setting values Using authority account type Administrator Manager User Guest gt Administrator administrator account which can setup the entire system from local area gt Manager manager account which can control the system from remote area gt User account which has authority on the sound sources BUS zone gt Guest account which monitors only system from remote zones Sound source selection and output selection sets up the sound source and BUS authority about remote connector User authority However system setting cannot be changed if remotely connected and certain parts of functions can be used Max 6 can be set with User authority and each user has independent sound source and using authority for one BUS output f user broadcasts the channel allocated to the user broadcasting of RM EM Input Sensor of the system has priority MS 6800 24 MANAGEMENT SOFTWARE 3 Log Confirm control log of user and changing of system setting will be displayed for each date 1 Display the
26. _ Installation amp Operator Manual Management Software MS 6800 inter MANAGEMENT SOFTWARE Contents dlc System Configurations tenete 2 Equipment Configurations 3 Equipment Setting 1 Setup the Equipment Number eene 4 2 Setup ine Termination Switch 7 3 Add Sound Sources to PV 6232 VOICE FILE and Setup the Communication Speed 7 Wiring the Equipment 1 Making Communication Cables EPIRI D SSH UD UNE 7 2 Method to Connect RS 485 Communication Line and Communication 9 3 Expanding the Zone through 6216 10 Conneccion Diagrani 11 5 Relationship of PX 6216 RM 60247 12 13 Install the Server Program and Hardware Basic Items 1 How to Setup the Control Setting of User Account Windows7 14 ore 9 3 Install the Hardware by Connecting DIB 6000 COM port 20 Starting Server Program ete T 22 2 COn si nied hes INI MEE 23
27. an be selected With Select Clear button entire zones can selected cleared Selected zone icon will be changed to as below Click 665 button to start the broadcasting G Icon of the zone will be changed to as below CDP is broadcasted in the ZONE 1 Click to finish the broadcasting If Select Group or Select All is checked among items Broadcasting Right Now of pages Configuration gt Other Setting broadcasting will be started with Select Group Select All Thus operation can be omitted 57 5 6800 MANAGEMENT SOFTWARE 6 Preset Select Broadcasting p Select the preset button H Sound source and zone will be selected in accordance the preset rules stipulated in the preset setting Refer to Preset Setting button to start the broadcasting If Preset is checked among Broadcasting Now of the Configuration gt Other setting broadcasting will be started only with Preset selection Thus operation can be omitted 7 Preset execute the preset functions set in the preset setting rreset Preset 2 Preset 3 Preset 4 Preset 5 Preset 6 If Preset button is clicked broadcasting will be started with certain sound source and zone previously set in the Preset Setting Max 12 presets display the preset page list A Preset B Preset7 Preset 2 To prepare the case of error on MS 6800
28. and detail setting values each channel can be set to the vertical direction 1 Use setup that input source will be used or not Use 0 Not use 2 Type setup the equipment type of input sources Input source types CD 610 CD 611 CD 660 CD 6208 TUNER DESK DIM 6000 MIC 3 Name insert the name of input source 4 Control port setup the control port which communicates with source units No Use Sourcel Source2 Source3 Voice Digi link Control port of Sourcel Source3 Voice 6216 Digi link additional Digi link converter is required 5 Priority setup the priorities for 8 outputs for each BGM input channel Priorities Highest 1O Lowest D Broadcasting by priorities method that highest priorities will be broadcasted first When sound source Ch1 which has high priority is being broadcasted if sound source Ch2 which has low priority is broadcasted only sound source Ch1 will be broadcasted When sound source Ch2 which has low priority is be broadcasted if sound source Ch1 which has higher priority is broadcasted sound source Ch2 will be stopped and only sound source Ch1 will be broadcasted When sound source Ch1 is being broadcasted if sound source Ch2 which has the same priority is broadcasted sound source Ch1 and sound source Ch2 will be mixed and broadcasted 27 5 6800 MANAGEMENT SOFTWARE 5 Unconditional Mixing broadcasting by mixing
29. and restarted below figures will be shown Automatic starting program C Program Files Inter M MS 6800 Server MS 6800 EXE cs 1 Login Below login window will pop up if is clicked A Login window will pop up if program is executed inter System LOGIN B Insert Admin in all IDs PWs for the first time Case sensitivity C User who has an admin account can change the PW in property menu D Refer to ID PW setting method Page 24 Other authorities are used when connecting to server with client MS 6800 22 MANAGEMENT SOFTWARE 2 Configuration If login is successful execute the configuration 1 PORT Setting setup the network and serial port values 1 Network setting Set that client functions remotely connected will be used or not 2 SERVER IP Port setup the IP and port of server PC to be connected from client 3 Serial port Setup the communication port of DIB 6000 connected to server PC Default value speed 9600 data bit 8 Parity Even StopBit 1 flow control N A H Check the Control Panel gt System gt Hardware gt Device Manager Communication Port 4 Saving setup save the current setting values 23 5 6800 MANAGEMENT SOFTWARE 2 User setting setup the user ID PW and authority ae 1 Account list display the account list 2 User Name insert the user name 3
30. atus Display Icon CH1 CH8 Divided into normal channel CH1 CH8 and SPARE channel Channel statuses are divided into as below GREEN On normal RED Off FAULT RED Blink switch to spare amp among fault channels Channel Name Changes If you want to select the channel name to be changed directly current channel will be displayed on below screen type the channel name you desire then push Enter button SAVE will save the changed status If Close button is pushed the screen will be closed 63 5 6800 MANAGEMENT SOFTWARE MS 6800 Program Help Print out the MS 6800 Program Manual es dp Tu deem guam ema 1m mms vg ee E E gm as bed tren Prop um amd Hed mg erm a mg d Proms orm en T SD HERO Pit m nm C omn oma anzi a Com XP Fm 1913 ls Taimer A AEE ot ryapuermp co UE erar sdb immer em ee cog nmm memi bh AS mung amm 1D
31. ce screen will pop up Mode 7 Source PC hea Dr uu m ne qi toma BJ Uem cies RH m ni in gy us m Add add the new music file to the list Delete delete the file selected in the list Save set the currently selected list to the play file 3 Zone Setting It is the screen which sets the zone where reserved broadcasting is sent and group and individual zone can be set 1 Select group select as the set group 2 Select zone select as the individual zone 3 Select output select as the set output 4 Application of Reservation It is the edit function about the reservation list it performs the add modify and delete functions Edit reservation edit the item selected in the reservation list Add reservation add the set item to reservation list Delete reservation delete the item selected from the reservation list If select the item to be edited setting content can be confirmed 41 5 6800 5 Save setting MANAGEMENT SOFTWARE List management fast edit and day copy about the entire reservation lists can be executed Peete La I 2 1 a z F 1 ng E
32. cordance with priorities for sound sources set in the macro MS 6800 36 MANAGEMENT SOFTWARE 4 EM router setup the scenario broadcasting when 16 Input sensors connected to ECS are on Interlocked with 6232 i IM IM 31 M 1 3H L 580 M 10 M n 19 1 0 I 2 M NM Lau ul LL c 11 S 1 01 dS p gama 1 l8 2 i 1 11 ee BO imus UM NEN 0 iee lhi er l e S JL gp pM ip aur dig Nu gr grad LJ LLLI 1 Sensor setup normal individual scenario for each Input sensor is set Click Sensor area Setup normal scenario setup the normal scenario for each Input sensor EM TE caps T0153 700 FID nde mm ENT APUL PEDUNE HIS DER HIS Sensor display the sensor number currently being set Start Time setup the broadcasting start time after Input sensor occurs minute second 37
33. e Selection Screen Broadcasting zone can be selected individually Entire zones can be selected cleared 15 Minimize and finish minimize the program finish the program MS 6800 46 MANAGEMENT SOFTWARE Check Communication Port Setting A If connection between PC and DIB 6000 is wrong or communication port COM setting is wrong below message will be displayed Message Can not communicate with 6216 Please reconnect the USH cable B If port and PC settings are incorrect in the Configuration gt Port Setting of the program it should be reset in the communication port setting Refer to Page 21 C After changing the setting restart the program 2 Controlling Sound Source It controls the controls of sound source PC CDP and Tuner of entire system Remote if it is checked Can control volume and digi link device 1 Input volume control controls 16 channel input audio volume of PX 6216 Sound source control consists of A and B page Volume B Volume A Output Bia Eo ea 2 2 lt Channell Channel8 gt lt Channel 9 Channel 10 EP Timer RM1 RM4 gt Simultaneous Control Set Status when controlling one channel volume ch1 ch10 input audio volume will be controlled simultaneously Not set statu
34. e and stabilize the data transfer 2 Set the Termination Switches in the equipment which link is started and ended to LOAD Set the other equipment to OPEN Address 1 Address 2 Address 3 Address 4 S W LOAD S W OPEN S W OPEN S W LOAD IN IN IN IN Caution if setting is incorrect communication error may occurs 3 Add Sound Sources to PV 6232 VOICE FILE and Setup the Communication Speed 1 Add broadcasting sound sources to PV 6232 A Connect PC and PV 6232 If PC and PV 6232 is connected by using cable PC will recognize it as a movable disk USB DEVICE will be displayed on the equipment window Caution when removing the cable connected to PC and unit please use Safe remove of hardware on the PC and stop the USB Storage before removing the unit If not data damage may occur 7 5 6800 MANAGEMENT SOFTWARE B Add Scenario Broadcasting Sound Source Only for MP3 file is possible 1 99 tracks can used as scenario sound sources among sound sources saved in 6232 Add 001 099 in front of file name used as sound source If PC and PV 6232 is connected with USB cable PC will recognize it as a movable disk Open the movable disk and copy paste the entire file to be used as sound sources Refer to PV 6232 User Manual for detail information 2 Add Basic Emergency Broadcasting Sound Source Only MP3 file is possible If scenario function is not used or Bypass Function is selected ba
35. e s Coe ee ee 2 5 n 20 LUE TIGE WCE i 16 x TECH AFD bz1H A 5 PH h DI 5 6800 2 MANAGEMENT SOFTWARE Equipment Component Basic Equipment Model Product Functions PX 6216 PA Control and Audio Matrix system MASTER Main Controller ECS 6216MS EMERGENCY COMBINATION SYSTEM SLAVE For zone expansion Max 10 units expansion DIB 6000 DIRECT BOX Multi Convertor Data audio RM 6024 SYSTEM REMOTE MIC STATION System remote MIC max 16 units expansion PB 6207 BATTERY CHARGER Charging the battery PD 6359 POWER DISTRIBUTOR Distributing the power to equipments x RME 6108 is required if 5 or more RM 6024s are used Additional Equipment Model Product Functions RM 6012KP 12KEY MIC STATION KEYPAD Remote MIC expansion keypad 12KEY RME 6108 REMOTE MIC EXTENDER Remote MIC expansion unit 8CH PV 6232 VOICE FILE Store the sound source of Emergency scenario AFD 6218 FAULT DETECTOR AMP Status indication function through the front LED SC 6224 Speaker Line Checker Check channel speaker line TP 6231 TELEPHONE PAGING Telephone paging device PC Requirements CPU Dual Core 2 8GHz Min 2 4GHz Dual Core 2 8GHz or higher RAM AGB Min 2GB AGB or higher H Monitor Resolution 1280 x 768 1280 x 1024
36. est Button If button is pushed the channel status which speaker is connected will be checked 5 Status Display It will be displayed as below depending on speaker line status check results GOOD speaker impedance within normal range NG speaker impedance out of normal range OPEN open speaker track SHORT short speaker track NC speaker not connected Channel Name Changes If you want to select the channel name to be typed directly current channel will be displayed on below screen Type the channel name you want then push Enter button SAVE will save the changed status If Close button is pushed the screen will be closed MS 6800 62 MANAGEMENT SOFTWARE 4 AFD 6218 Monitoring the status of AFD 6218 Amplifier Fault Detector IF AFD button is pushed below screen will be displayed Corte p Communication Status and Equipment Name Display Communication status will be shown as below GREEN normal RED unable to communicate Equipment name can be changed in the Configuration setting gt input 2 Page Select Button The status of Max 5 equipments can be displayed per one page and if select button is pushed it will be moved to a relevant page TEST Button If button is pushed channel status which speaker is connected will be checked Refer The result display may be delayed even if the numbers of equipment are expanded Channel St
37. g contact point signal See the guideline and push the confirm 4 Use scenario setup the Scenario using mode to use and not use Use if Input sensor occurs it will be operated as the scenario mode Not use if Input sensor occurs it will be operated as the normal Input contact point mode Operated as Input sensor mode in Configuration gt Input Sensor 5 Save save the setting values 5 6800 38 MANAGEMENT SOFTWARE 5 Preset sound source and zone information Preset setting information set in the operation mode will be displayed Only label name can be set in the current page Preset setting is set in the operation mode Reference refer to Preset in the operation mode 1 Preset select the preset 2 Preset label insert the preset label name 3 Input button setup as the name inserted the preset label 4 Save preset save the preset label 5 Select sound source display the sound source of selected preset 6 Select zone display the zone of selected preset 7 A B display the zone name A Zonel Zone80 B Zone81 160 If output zone is changed in equipment input output setting zone setting should be redone 39 5 6800 MANAGEMENT SOFTWARE 6 Scheduling With scheduling PC timer reservation broadcasting previously set sound source can be played in the zone you want LEP pE ge a x CRSP SS Dep e
38. hen timer PW 6242A mode occurs 2 Select group select the group Zone set in the group will be selected 3 Select zone Select the zone 4 A B display the zone name A Zonel Zone80 B Zone81 1 60 5 Select all select all zones 6 Clear clear all zones selected 7 Save save the setting values In abouve figure EP Timer setting is operated with EP MIC mode and when using MIC of EP It will be broadcasted to all 1st grade classes 35 5 6800 MANAGEMENT SOFTWARE 9 Sound source macro it is the function that treats the 2 or more mixed sources as one source if you want to mix 2 or more BGM sources a c We ia HHI eri T 9 ee lI m x e a 2 2 ZU 4 1 Add sound source macro EP MIC operate in EP mode TIMER operate in timer mode Select sound source left click the mouse on the sound source are to be moved and drag to the position you want to move it and unclick the mouse the sound source macro domain 2 Delete delete the sound source macro composition 3 Save save the setting values Max 4 sound source macros can be made Max 4 sound sources can be added in each sound source macro Macro icon will be activated when setting up the macro in the sound source selection of operation mode Broadcast may not be started in ac
39. is set as All Entire sound sources and zones can be controlled User Authority Modes Administrator administrator account which can setup the entire system from local area Manager manager account which can control the system from remote area User account which has authority on the sound sources BUS zone Guest account which monitors only system from remote zones MS 6800 74 MANAGEMENT SOFTWARE 2 If user authority is User 1 Authority Setup wb Setup the user account in MS 6800server gt Configuration gt ID PW 1 User authority User 2 Select sound source MIC Channel 1 select MIC 3 Select output output 1 Select output number 1 Local zone connected in output number 1 can be selected Refer to Configuration gt Input Output output setup Page 23 2 MS 6800 Client Connection inter System LOGIN 192 1568 48 99 Port 4100 jupiter 2002 Password Exit Connect Close Connect with jupiter2002 which has user authority 75 5 6800 MANAGEMENT SOFTWARE 1 IP insert the IP address of MS 6800 server program 2 Port insert the port of server program Default 4100 3 ID insert the user name 4 Password insert the user password Case sensitivity 5 Click the connection button If connection is success below screen will pop up
40. itivity 9 Click the connection button f connection is success below screen will pop up ED C H L Fonsi t a d All sound sources and zones will be displayed Client screen configuration consists differently in accordance with the user authority who connects The reason consisting the screen as shown above are as follows 4 Connected user authority is Guest 5 Sound source selection of connected user authority is set to All 6 Output selection of connected user authority is set to All Entire sound source and all zones cannot be controlled Guest has only monitoring function 5 6800 78 Inter AIO40 Inter M Ltd Korea began operations in 1983 Since then Inter M has grown to become one of the largest manvfacturers of professional audio and commercial sound electronics equipment in the world Inter M has gained worldwide recognition for its own branded products as well as private label manufacturing of electronics sold under other names The company is no longer just a Korean company but rather a global company that is truly international in scope with factories and offices in Korea and China and sales and marketing operations located in Japan Europe and the U S A With more than 850 employees around the globe Inter M is well poised for further growth and expansion Inter M Americas Inc 13875 Ar
41. l prbemt Iram malen Chesed Do pow compute T TTE 1 ares ope see gg Progam dry ti ental maker change tz mri Copter 1 make bo Windows dete Het im omeamded Cheater tha you nes uie pes aee Geet foe 7 they do not iuepert Centre 2 Program Installation 1 Execute the MS 6800_Server_v1 0 0 0 exe in Set_up CD Click Install button if below screen pops up Caution if Visual C Runtime Libraries x86 is already installed below screen will not pop up In this case start from step 2 t1 Hoaorstrapper Package Setup Do you wish lo install these comperi s 7 you choose Cancel setup wil ext 15 5 6800 MANAGEMENT SOFTWARE 2 Language selection screen Click Next button fe 5 5800 1 1 Select your language mE p Welcome to the M5 6800 SERVER 1 1 1 7 Setup Wizard MS 6800 16 MANAGEMENT SOFTWARE A Final user right contract screen Check Agreed and click Next button 5 5800 1 1 End User License Agreement Fiesse read the foloveng agreement This At the user s permissions If vou do not agree to this agreement users of this software you can not install or use 1 Permission to use The user to use this software legitimately you can download or copy In addition the backup
42. m oum AIT LI De NE i a coe Um LN E E en Re E P PPNP N MnP LA eF mm E 8 m Nu emm a m mue 5 1 Reservation setting list display the reservation list for each day Select day select the reservation day Sunday Saturday Select list display the detail information of selected schedule on 1 2 2 Reservation Setting Reservation name insert the reservation name Starting time insert the starting time Finishing time insert the finishing time Reservation type select the sound source to be broadcasted Digi link use the external unit sound source Control the source units and plays the Track CD and preset Tuner sound sources of selected source units PC use the PC internal sound source Control PC internal sound source Add delete PC file to play the file in the list Input setting select the source unit to be played or load the sound source If Digi link Click Ea icon then Digi link setting window will pop up Mode Source 5 6800 40 MANAGEMENT SOFTWARE After selecting the sound source and track number preset number click Set button to finish the setting For PC click icon then sound sour
43. ment ID is same sequnence number of equipment 5 6800 28 MANAGEMENT SOFTWARE 2 Output setting setup the values on audio output channels d d o ou 1 m 1 Use setup the input source will used not Click the output image terminal domain D 4 E Use Not used 2 SR setup that 2 outputs to be used as 1 stereo SR output Number setup the channel stereo direction values Ex 4 L Number 7 channel Left output 4 R number 8 channel Right output 3 Select output select the output channel to be broadcasted 16 zones of ECS 6216MS 4 Zone setup drag the ECS 6216MS zone cell domain with mouse Vertical direction 5 6216 5 equip no Lateral direction local number of ECS 6216MS Clear button change the all zones and zone setting values to Not Set Lateral number when number domain is clicked zone setting value of vertical direction is changed to Not Set Vertical number when number domain is clicked zone setting value of lateral direction is changed to Not 5 Panel management when installing for the first time it manages the panel number and name 29 5 6800 MANAGEMENT SOFTWARE 3 Zone name setting setup the ECS 6216MS zone name Max 160 zones can be set
44. n if USB driver is already installed below screen will not pop up In this case step 8 and 9 will be omitted LJ installation completed successfully 19 5 6800 MANAGEMENT SOFTWARE 10 Installation completing screen Click Finish button Restart the system if installation is finished Completed the MS 6800 SERVER 1 1 1 7 Setup Wizard the Engh button to ex 3 Installing Hardware by Connecting DIB 6000 COM port 1 Check the COM port status in the Device Manage in PC Control Panel Because Windows programs use No COM1 COM4 port communication will not be available if setting port is not matched 2 How to Check and Change COM Port Setting A Select the COM port and check the property MS 6800 20 MANAGEMENT SOFTWARE 2 How to Check and Change COM Port Setting A Select the COM port and check the property B Port can be changed through Advanced menu Use FIFO buffers 16550 compatible Select lower setbngs to comect connection problems Select higher setbngs for faster performance Receive Buller Low 1 Buffer Low 1 Number C Select the port among 1 and change D Then set the port to be used as same in Property gt Port Setting menu 21 5 6800 MANAGEMENT SOFTWARE Starting Server Programs After programs are installed
45. ng 3 RM 6024 TP 6231 ADDRESS OFF ON 12 4 8 16 TP 6231 can be used as RM 6024 and the setting of equipment number is same MS 6800 4 MANAGEMENT SOFTWARE A Setup the equipment number in accordance with connecting conditions by using the rear panel DIP switch Any setting not 0 will be available If equipment number is not set zone display LED will blink FAULT LED on the front panel will be on if same numbers are used At this time check the equipment number settings B Example when connecting 4 RMs to PX 6216 Setup the 1 for equipment number of RM 6024 connecting to RM1 terminal Setup the 2 for equipment number of RM 6024 connecting to RM2 terminal Setup the 3 for equipment number of RM 6024 connecting to RM3 terminal Setup the 4 for equipment number of RM 6024 connecting to RMA terminal RM 6024 RM 6024 RM 6024 e C When connecting to PX 6216 through RME 6108 Refer to below figures and caution to relationship between connecting terminal and equipment number x Caution if equipment numbers are overlapped it will be FAULT status Check the overlapped numbers through LED on the RME front panel and re set it RME 6108 uoa inter m com umm 6024 Each RM of PX 6216 uses independent communication so 4 RMs be expanded as shown in above figure 5 5 6800 MANAGEMENT SOFTWARE D Setting method is as follow and
46. ol of 7 Band EQ mixing sound sources A Savinf function of equipment setup information 5 System log record EM RM broadcastings 7 MIC broadcasting using PC MIC exclusive for Client PC and common Ex 01 8 BGM broadcasting using PC sound sources HDD 9 Timer broadcasting using PC sound source HDD source 10 Remote control of source units CDP TUNER 11 Macro setting about input sensor and making evacuation broadcasting scenario Time zone sound source 12 Zone marco seeting for all buttons of RM 13 PD 6359 PB 6207 AFD 6218 SC 6224 Equipment status monitoring and controlling 2 Preparations Considering PC Errors 1 Emergency Broadcasting When setting the common macro information is also saved in PX 6216 to prepare the PC errors When setting the emergency scenario function information is also saved in PX 6216 to prepare the PC errors 2 TIMER Broadcasting If PW 6242 A is connected together it will be converted automatically for PC error Priorities PC TIMER gt 6242 x Caution When making the schedule the PW 6242 A Start Finish times should be same as the contents PC If it is operated with PW 6242 A broadcasting will be on in the zone set in the MS 6800 3 RM Macro Operation Macro setting information is saved in the PX 6216 for PC errors 1 5 6800 MANAGEMENT SOFTWARE System Configuration Line Lew tang 100v eel fo Lin
47. one 12 fone 38 fone 39 E Fone 47 5 1 Fone 55 fone change the entire zone list in selected status change the entire zone list in cleared status o p AI EEE ts MANAGEMENT SOFTWARE 3 Zone status value classifies the PX 6216 8 Bus with color and display it Means number 1 BUS of PX 6216 and display the zone not selected selected status Means number 2 BUS of PX 6216 and display the zone not selected selected status Means number 3 BUS of PX 6216 and display the zone not selected selected status Means number 4 BUS of PX 6216 and display the zone not selected selected status Means number 5 BUS of PX 6216 and display the zone not selected selected status Means number 6 BUS of PX 6216 and display the zone not selected selected status Means number 7 BUS of PX 6216 and display the zone not selected selected status Means number 8 BUS of PX 6216 and display the zone not selected selected status If broadcasting is conducted with other sound source new sound source will be mixed or only new sound source will be broadcasted after stopping the previous broadcasting Depending on BGM broadcasting method Broadcasting by Mixing setup value it will be operated differently Refer to Configuration gt Other Setting Shows that CDP is broadcasted in the zone Shows that CDP and tuner is mixed in the zone and broadcasted 3 Shows
48. regardless of broadcasting priorities When sound source Ch1 which has high priority is being broadcasted if sound source Ch2 which has low priority is broadcasted both sound sources will be mixed regardless of priorities When sound source Ch2 which has low priority is be broadcasted if sound source Ch1 which has higher priority is broadcasted both sound sources will be mixed regardless of priorities e After inserting the priority in item A for each channel and if click All button it will be applied to all output channels Refer to Configuration Input setting for BGM broadcasting type selection Even if BGM priority is 1st it has lower priority than EP Timer RM Entire system priorities are as below EM of gt MIC gt Input Sensor gt Timer Schedule gt RM1 gt RM2 gt RM3 gt RM4 gt BGM Use setup that input source will be used or not Use Not use 6 Monitoring setup the values of equipment About PD 6359 PB 9207 SC 6224 AFD 6214 Monitoring 1 PD 6359 Power Distributor Setup PD equipment Max equipment number 20 3 PB 9207 Battery Charger Setup PB equipment Max equipment number 20 3 SC 6224 Speaker Line Checker Setup SC equipment Max equipment number 12 4 AFD 621 A Fault Detector Setup AFD equipment Max equipment number 20 Use setup that equipment will be used or not Number setup the numer of equipment Equip
49. rity is Manager 4 Status Display Icon Display the communication status with server Green for normal and red for communication failure 5 Sound Source Control Function not supported in the remote mode 5 6800 70 MANAGEMENT SOFTWARE 71 6 Preset Selection Screen Preset set in the preset setting window can be selected Preset screen consists of two screens A and B and each displays the 6 presets and total 12 presets can be selected If preset button is clicked only button is selected At this time click right button while setting the preset input output volume EQ source output BUS and zone will be saved Double click the button for saved presets 7 Broadcasting Status Screen Displays the type of broadcasting RM BGM EM etc 8 Power Distributor Button Turn on off the power of the power supplier under stand by status in BGM mode 9 Emergency Broadcasting Button Changed to EM mode 10 PCMIC send the client remote computer MIC input sound source to server unit Macro functions are only available to the person whose user authority is 11 Monitoring The values of equipment About PD 6359 PB 9207 SC 6224 AFD 6214 12 Group Selecting Screen Select the broadcasting zones as the group Only set in the MS 6800 server program 13 Zone Page Selecting Screen Page displayed on the zone selecting screen can be selected 14 Broadcasting Start Finish Button 10
50. s only channel input audio volume will be controlled 47 5 6800 MANAGEMENT SOFTWARE 2 Output Volume controls 8 channel output audio volume of PX 6216 Simultaneous Control Set Status when controlling one channel volume ch ch10 input audio volume will be controlled simultaneously Not set status only channel input audio volume will be controlled Volume All 3 Output EQ controls 8 channel of individual EQ volume of PX 6216 Simultaneous Control simultaneous control will not be supported in output EQ gt 1 Output EQ Channel Ch1 8 Select the output channel and control the EQ Volume 5 6800 48 MANAGEMENT SOFTWARE 4 Digi Link sound source control CDP control controls the CS player which is audio input unit p CDP registered as the source unit can be selected 2 Displays the selected track and playing status CDP control button Pull out play stop forward and backward buttons on it Track can be selected with combinations of numbers is cancel 5 is select buttons TUNER control control the tuner which is audio input unit 1 Preset number of tuner registered as the source unit can be edited 2 Preset number being played will be displayed 3 Preset numbers set in the tuner can be selected with combinations of numbers C is cancel S is select buttons Displays the current broadcasting status 49 5 680
51. sic emergency sound sources in the PV 6232 will be played These sound sources can be added or changed A If PC and PV 6232 is connected with USB cable PC will recognize it as a movable disk Select the disk and check the folder structure in below and if not make the same structure Change the basic emergency sound sources name to EMORG mp3 and copy it in IMSND folder INTER M i AUDIO IMSND d MPXP es VOICE Remove the USB cable and check the operation x Caution if file name and folder structure is wrong normal play will not be possible x Caution if USB cable is not removed normal play will not be possible 3 Change the PV 6232 Communication Speed Baud Rate For EM scenario broadcasting communication speed should be adjusted if PV 6232 is used A Default setting is 19200BPS It should be changed to 9600BPS B How to Change Push the STOP button on PV 6232 then BaudRate 19200BPS will be displayed BaudRate 19200BPS Use 1 buttons on PV 6232 to select 9600BPS BaudRate O600BPS Push the ENTER button on PV 6232 to save and finish the setting Setup will be cancelled if DELETE button on PV 6232 is pushed during communication setting 5 6800 8 MANAGEMENT SOFTWARE Wiring the Equipment Caution when Installing Do not connect wires or communication cables while equipment is on It may cause failure Ex Communication functions of equipment 1
52. tesia Blvd Cerritos CA 90703 USA TEL 41 562 921 0313 FAX 1 562 921 0370 Home Page http www inter m net E mail infoGinter m net Inter M Corporation Seoul OFFICE 653 5 BANGHAK DONG DOBONG KU SEOUL KOREA TEL 82 2 2289 8140 8 FAX 82 2 2289 8149 MADE IN KOREA Home Page http www inter m com E mail overseas inter m com November 2012 132161
53. that tuner and MP3 is mixed in the zone and broadcasted Shows that MIC CDP tuner and MP3 is mixed in the zone and broadcasted Shows that status broadcasting with schedule mode in the zone Shows that status broadcasting with remote MIC mode in the zone 5 6800 54 MANAGEMENT SOFTWARE Shows that CDP and remote is mixed and broadcasted the zone Shows that status broadcasting with schedule mode in the zone Shows that current user has no access on the zone 4 Select zone page button classify with zone page 1 2 3 and SR zone page and used when changing the broadcasting zone Zone page 1 displays the zone list from Zonel to Zone72 Zone page 2 displays the zone list from Zone73 to Zone 44 Zone page displays the zone list from Zone145 to 160 SR Zone page display that PX 6216 output channel is in the list with SRport Refer to Configuration gt Output Setting 7 5 start the broadcasting in the selected zone list 1 6 finish the broadcasting in the selected zone list 4 MIXINGVolume control control the mixing volume for each channel in the output channel 8 channels Mixing volume window will be displayed if mixing volume control of sound source is selected in the menu by right click the mouse on the zone
54. ting group setting should be redone 3l 5 6800 MANAGEMENT SOFTWARE 5 RM Config set up the zone where RMMIC is broadcasted Lim dn arn i 4 1 1 1 Use choose whether RM1 is used or not Use CD Not use RM4 be set and if expansion keypad is used max 48 macros used 2 BGM choose whether Background Music mode is used or not Use 4900 Not use When using it RMMIC and BGM audio is mixed and output When mixing and outputting BGM LEVEL is decreased Choose that BGM mode is used when using the RM by setting up the RM Setup to vertical direction RM1 BGM RM2 BGM RM3 BGM RM4 BGM Ex If number 1 RM is used it will be operated as BMG mixing mode If number 2 RM is used it will not use the BGM mixing mode 3 Select RM select the RM equipment number connected to PX 6216 RM1 1 RMA 4 4 Keypad number select the keypad number Basic basic keypad 1 24 Extend extended keypad 1 24 5 Select zone select the zone will be displayed on the selected zone 6 A B display the zone name A Zonel Zone80 B Zone81 160 7 Select all select all zones 8 Clear all clear all selected zones 5 6800 32 MANAGEMENT SOFTWARE 9 Save setting save the set
55. ting value If RM is extended through ME 6108 ID of RME 9108 on the RM port should be set If number 1 button of RM1 is pushed RM setting outputs from class 1 1st grade to class 8 1st grade Entire 1st grades If output zone is changed in the equipment input output setting zone setting should be redone 6 GPI setting setup the operational method when 16 Input sensors connected to ECS are ON 1 Select ECS select the ECS 6216MS equipment number 2 Select Input Sensor D 3 3 Select the sensor number 2 Choose whether it is selected or not Selected 8 Not selected 3 Select the sensor operation type F Emergency Mode when input sensor is on operate in emergency mode N Normal Sensor Mode when input sensor is on operate in normal mode Normal contact point macro operate with setting values E EP Mic Sensor Mode when input sensor is on operate in Emergency Mic mode P Preset Mode when input sensor is on operate in preset mode In preset operate with setting values 4 Select the mode operation number When Normal Sensor Mode setup the normal mode macro number Numbers 1 16 When P Preset Mode setup the preset mode number Numbers 1 12 33 5 6800 MANAGEMENT SOFTWARE 3 A B display the zone name A Zonel Zone80 Zone81 1 60 4 Select zone Select the zone
56. tion is finished Completed the M5 6800 CLIENT 1 0 0 3 Setup Wizard Chck the Fresh bution to exit tne Setup Vizard MS 6800 68 MANAGEMENT SOFTWARE Starting Client Program 1 LOGIN interii Digital PA System 1 IP insert the IP address of MS 6800 server program 2 Port insert the port of server program Default 4100 3 ID INSERT THE USER NAME 4 Password insert the user PW Case sensitivity 5 Exit finish the program 6 Connect connect to server 7 Close close the login window After closing the window if screen is click login window will pop up again Register the user in the configuration of MS 6800 program Refer to MS 6800 gt Configuration gt ID PW setting 1 PORT Setting 1 SERVER IP insert the server IP to be connected 2 SERVER Port insert the server PORT to be connected 3 User ID insert the user ID 4 PassWord insert the user PW 5 Save save the setting values 69 MS 6800 MANAGEMENT SOFTWARE 2 Client Screen Functions M L 1 Connected serverlP Display the connected IP address 2 Display the Client Remote program version 3 Display the sound source Broadcasting sound source can be selected Sound source can be set in Configuration gt Source When selecting the macro sound source can be selected by using macros set in the configuration Macro functions will be available only for user autho
57. with the system directly Login ID will be displayed on the back 6 Preset Selection Screen 1 Preset set in the preset setting window can be selected 2 Preset screen consists of two screens A and B and each displays 6 presets and total 12 presets can be selected 3 Only button will be selected if preset button is clicked At this time if click right button and setup the preset currently broadcasted input output volume EQ source output BUS and output zone will be saved 4 Saved preset can double click the button 45 5 6800 MANAGEMENT SOFTWARE 7 Broadcasting Status Screen Displays the type of broadcasting RM BGM EM etc 8 Power Distributor Button Turn on off the power of the power supplier under stand by status in BGM mode 9 Emergency Broadcasting Button Changed to EM mode 10 Monitoring monitoring PD 6359 PB 6207 SC 6224 AFD 6214 equipment Of PD 6359 PB 6207 SC 6224 AFD 6214 is Monitoring 11 Group Selection Screen is used when selecting the broadcasting zone and max 16 group can be set Able to set the configuration 12 Zone Page Selection Screen Page displayed on the zone selection screen can be selected 13 Broadcasting Start Finish Button 1 Broadcasting Start After selecting the zone to be broadcasted and push the start button to broadcast 2 Broadcasting Finish Select the zone being broadcasted and push the broadcasting finish button 14 Zon
58. yed 05 tory Cheep i p Communication Status and Equipment Name Display Communication status will be divided as below GREEN normal RED unable to communicate Setup of Equipment can be changed in the Configuration setting gt input 2 Display Charging Voltage Current Display the charging voltage and current of battery Name Input the name of PB 6207 Enter Apply the name of PB 6207 Channel Name Changes If you want to select the channel name to be typed directly current channel will be displayed on below sceen Type the channel name you want then push Enter button SAVE will save the changed status amp IF Close button is pushed the screen will be closed 61 5 6800 MANAGEMENT SOFTWARE 3 SC 6224 Monitoring the status of SC 6224 Speaker Line Checker If SC button is pushed below screen will be displayed BC dud 44 uz ir p Communication Status and Equipment Name Display Communication status will be shown as below GREEN normal RED unable to communicate Equipment name can be changed in the Configuration setting gt input Confirm Button If button is pushed speaker track impedance of all 24 channels will be measured and saved in the memory 2 Page Select Button The status of Max 4 equipments can be displayed per one page and if select button is pushed it will be moved to the relevant page T