Home
CPU-SB303-FIT-3F CPU-SB304-FIT-45F
Contents
1. USB Compact Flash F amp eIT I F A GE LINE OUT nnnn di Ge MiC e rJ nnn 10 100BASE TX Wie a 12 E L1 E 5 1000BASE T uSW ENT RESET pud COM H POWER E e e Ss p a Gao oo ea ES ES E E S Secondary IDE m Cu i jp Ea E44 lo Figure 3 1 Nomenclature CONTEC CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 23 3 Functions of the Various Components Table3 1 Functions of the various parts Name Function Serial port connector D SUB 9 pin COM CRT connector HD SUB 15 pin CompactFlash Compact FLASH insertion connector TYPE 1 or TYPE 2 Any microdrive or CompactFlash that supports True IDE mode can be used Secondary IDE Allows the optional CD ROM DVD ROM drive to be connected if the optional dedicated cable is used C The switch state on or off can be read from IO port 8802 0 POWER Power supply connector MC1 5 3 G 3 5 PHOENIX CONTACT F amp eIT I F F amp eIT series connector 0 6mm pitch 80 pin FX 8C series HIROSE F LED 1 2 SW SB IC 1 CONTEC 24 CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 3 Functions of the Various Components Serial Port Interfac
2. ACPI Controls ACPI 1 State Disabled Figure 4 16 Boot Features Window Factory Settings ACPI 51 State Disabled Enabled or Disabled the stand by mode Enabled CONTEC CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 59 4 BIOS Setup PC Health Menu Main Advanced Security Power C Health Boot Exit gt Hardware Monitor Setup Thermal 0 35 C 95 F 5V 5 00 V 3 3 3 30 VBattery 3 00V Figure 4 17 PC Health Window Hardware Monitor Setup Warning Temperature settings Thermal 0 This field displays the current temperature 5 3 3 VBattery These fields display the current voltage of input lines Hardware Monitor Setup Main Advanced Security Power Boot Exitt Hardware Monitor Setup Warning Temp Termal 0 Disabled Clock Moduration Duty Disabled Figure 4 18 Hardware Monitor Setup Window Factory Settings Please use basically with default setting Warning Temp Disabled Alarm when the temperature increasing Thermal 0 45 113 75 167 Clock Moduration Duty Disabled Lowering the CPU clock decreases the CPU 12 5 87 5 performance to control the heat generated by the CPU CONTEC 60 CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 4 BIOS Setup Boot Menu After you turn on it will a
3. D7 D6 D5 R Line Status Register D4 D3 DTR 0 Inactive HIGH 1 Active LOW RTS 0 Inactive HIGH 1 Active LOW Interrupt control bit 0 Disabled 1 Enabled L Diagnostic local loop back test 0 1 Disabled Enabled D2 DO 0 TEMT HRE BI DR _ Data ready 1 means data received Overrun error 1 means an error detected Parity error 1 means an error detected Framing error 1 means an error detected Break interrupt 1 means break detected L Transmitter empty L Transmitter holding register empty 1 means transmitter buffer empty 1 is set when both the transmitter holding register and the transmitter shift register are empty MSR Modem Status Register D6 D5 D4 D3 D2 Di DO DCD RI DSR CTS DDCD DCTS SCR Scratchpad Register This is an 8 5 data saving register that is user accessible for read and write operations CONTEC Delta CTS Delta DSR Because these Trailing edge RI status bits are A not used in the ta data carrier detect RS 485 the data has no meaning CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 29 3 Functions of the Various Components Setting the Baud rate Software sets the baud rate by dividing the clock input 1 8432MHz by an appr
4. Main Advanced Security Power Health Boot Exit Exit Saving Changes Exit Discarding Changes Load Setup Defaults Discard Changes Save Changes Figure 4 20 Exit Menu Window The following sections describe each of the options on this menu Note that lt Esc gt does not exit this menu You must select one of the items from the menu or menu bar to exit Exit Saving Changes After making your selections on the Setup menus always select either Saving Values or Save Changes Both procedures store the selections displayed in the menus in CMOS short for battery backed CMOS RAM a special section of memory that stays on after you turn your system off The next time you boot your computer the BIOS configures your system according to the Setup selections stored in CMOS Once the selections are saved the following message will appear Press space to continue If you attempt to exit without saving the program asks if you want to save before exiting During boot up PhoenixBIOS attempts to load the values saved in CMOS If those values cause the system boot to fail reboot and press F2 to enter Setup In Setup you can get the Default Values as described below or try to change the selections that caused the boot to fail Exit Discarding Changes If during a Setup Session you change your mind about changes you have made and have not yet saved the values to CMOS you can restore the values you previou
5. 2 The gt mark indicates it has a submenu Figure 4 1 Main Manu Window Factory Settings CONTEC 46 CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 4 BIOS Setup Keystrokes Use the keys listed in the legend bar on the bottom to make your selections or exit the current menu The chart on the following page describes the legend keys and their alternates Load the Default Configuration values for this menu You can make the following selections on the Main Menu itself Use the sub menus for other selections HH MM SS MM DD YYYY Set the system date Primary Master This field is set to Set to the type of the drive on primary IDE master AUTO by default You Primary Slave Set to the type of the drive on primary IDE master 1 can leave it intact for Secondary Master n rmal age Set to the type of the drive on primary IDE master Secondary Slave Set to the type of the drive on primary IDE master 2 Displays amount of conventional memory detected during boot up Displays the amount of extended memory detected during boot up 1 No drive can be connected to the Primary Slave 2 Please do not connect it of the slave alone You can set the boot sequence of the bootable drives by selecting the Boot Sequence from the main menu or opening the Boot Menu CONTEC CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 47 4 BIOS Setup Primary Secondary Maste
6. 1280 x 1024 256 colors 1400 x 1050 1600 x 900 1600 x 1200 1856 x 1392 1920 x 1080 1920 x 1200 16 770 000 colors 1920 x 1440 65 536 colors Ethernet 100BASE TX 10BASE T Ethernet 100BASE TX 10BASE T RJ 45 connector Built in Intel ICH4 RJ 45 connector DP83815 or DP83816 National Ethernet 1000BASE T 100BASE TX 10BASE T Semiconductor RJ 45 connector Intel 82541PI 4 channels USB 2 0 compliant High Full Low 2 channels OHCI Ver 1 0 compliant Speed compliant None P8f2 type keyboard 6 pin MINI DIN connector None type mouse MINI DIN connector 1 255sec 255 level When timing up reset Programmable 16666sec Max Reset or output to IRQ when time is reached Equipped with the dedicated 40 pin half pitch None connector Connects the CD ROM DVD ROM drive Bottom side Life of lithium backup battery Life of lithium backup battery 6 years or more When no power supplied When power supplied 25 10 years or more 25 C Accuracy of realtime clock less than 3 Accuracy of realtime clock less than 3 min month min month 25 C dimensions mm installed vertically metal fittings 900g CONTEC 80 CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 6 Appendix Microsoft Windows XP Professional Embedded Microsoft Windows XP Professional Embedded Operating Microsoft Windows 2000 Professional Microsoft Windows 2000 Professional Systems 1
7. 2 When the F amp eIT BUS is not used for single use it is 45 35W 3 Power capacity tempers with the margin 10 and it is recommended to use the power supply of 70W or more When using the controller unit for single use it is recommended to use the power supply of 50W or more DIN rail connectable power supply is as follows DENSELLAMBDA DLP75 24 1 DIN rail connectable IDEC PS5R SD24 DIN rail connectable OMRON S8VS 06024 DIN rail connectable CONTEC CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 67 5 Specifications System Configuration COM 2 FIT GY DIO 8 8 FIT GY ee ADI12 8 FIT GY USB keyboard USB mouse CNJ SB30 L me 5 d tel FI iie E 28 ch l s 5 B s cH Ig E e MO 2 je amp fiel WO el HO 1 el EO 2 E 3 H Y mo 1 e HO 5 Nd 6 wo 7 iets 105 COM 2 ADI12 8 DIO 8 8 Network RS 232C CF card Figure 5 1 System configuration diagram CONTEC 68 CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 5
8. Disabled Cache E400 E7FF Write Protect Cache E800 EBFF Write Protect Cache 0 EFFF Write Protect Figure 4 3 Cache Memory Features Window Factory Settings Please use it basically by the default setting Cache System BIOS System BIOS is cached and the performance is improved Cache Video BIOS Video BIOS is cached and the performance is improved CONTEC 50 CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 4 BIOS Setup Memory Features Main Advanced Security Power Health Boot Exit Memory Features Enable memory gap Disabled Figure 4 4 Memory Features Window Factory Settings Please use basically with default setting Enable memory gap Disabled If enabled turn system RAM off to free address space for Enabled use with an option board Either a 128K conventional memory gap starting at 512KB or a 1MB extended memory gap starting at 15MB will be created in system RAM PCI Features Main X Advanced Security Power Health Boot Exit PCI Features gt PCI IRQ Figure 4 5 PCI Features Window Factory Settings Please use it basically by the default setting PCI IRQ Displays the PCI IRQ setup submenu You can assign IRQs to individual PCI IRQ lines All PCI slots are connected to IRQ10 by default However this setting is set to
9. Is there any way to recover Windows XP Embedded on CPU SB303 FIT 3F CPU SB304 FIT 45F It can be recovered by using the bundled recovery CD either in a USB based CD DVD ROM drive or Secondary IDE based CD ROM DVD ROM drive connect the optional CD ROM DVD ROM drive IPC CDD 03 to the IDE cable IPC CDC 03 Please provide necessary equipment yourself according to the CD ROM DVD ROM to be used For details of the recovery operation please read the bundled Pre installed OS Recovery Procedures 78 CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 6 Appendix e What is the drive configuration and how big is the capacity at the time of OS pre installation A The drive configuration only takes one drive one partition Consequently only the C drive is available for a CF CPU SB21 FIT GY CPU SB22 FIT GY has a single drive two partitions configuration The capacities are as follows o om pem Te e CPU SB303 FIT 3F C drive Cem 1 seen sme 1 12208 CPU SB304 FIT 45F Windows XP Embedded sp2 EWF partition None CF 2GB The capacities are current as of July 2007 They may be changed in the future EWF partition refers to a management area partition designed for use of the Embedded Write Filter function in the XP Embedded pre installed model Remarks The user is not allowed to make partition changes CONTEC cannot provide the user with any informat
10. Disabled and IRQ is allocated against the PCI device when you set the APIC IO APIC Mode to Enabled in the Advanced Menu CONTEC CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 51 4 BIOS Setup IDE Features Main Advanced Security Power Health Boot Exit IDE Features IDE Device 31 Function 1 Enabled Local Bus IDE adapter Both Hard Disk Pre Delay Disabled SMART Device Monitoring Enabled Figure 4 6 IDE Features Window Factory Settings Please use basically with default setting IDE Device 31 Disabled Enable or Disable the IDE Controller Function 1 Enable Local Bus IDE adapter i The IDE channels setting Hard Disk Pre Delay i Adds a delay before the first access of a hard disk by the BIOS Some hard disks hang if accessed before they have initialized themselves This delay ensures the hard disk has initialized after power up prior to being accessed 12 seconds 15 seconds 18 seconds 21 seconds 30 seconds SMART device Disabled Turn on Self Monitoring Analysis Reporting Technology monitoring Enabled which monitors condition of the hard drive and reports when a catastrophic IDE failure is about to happen CONTEC 52 CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 4 BIOS Setup Video Features Main Advanced Security Power Health Boot Exit Video Features
11. IGD Memory Size UMA 8MB Internal DDC ROM Enabled Splash Screen Size 1024x768 Figure 4 7 Video Features Window Factory Settings Please use basically with default setting IGD Memory Size UMA 1M When Enabled a fixed VGA frame buffer from A000h BFFFh and UMA 8M a CPU to PCI write buffer are implemented UMA 16M UMA 32M Internal DDC ROM i Enables or disables the internal DDC ROM for the CRT interface When Enabled it reads DDC data from the internal DDC ROM In normal cases use it while Enabled Splash Screen Size 640 x 480 Select the panel device resolution 800 x 600 1024 x 768 1280 x 1024 LAN Features Main Advanced Security Power Health Boot Exit LAN Features Internal LAN Device 8 Enabled Figure 4 8 LAN Features Window Factory Settings Please use it basically by the default setting Setting item to Enabled will allow the LAN to operate correctly Setting item to Disabled will remove the LAN from PCI configuration space LAN 10 100BASE TX CONTEC CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 53 4 BIOS Setup USB Features Main Advanced Security Power PC Health Boot Exit USB Features USB Device 29 F7 Enabled Legacy USB Support Enabled Figure 4 9 USB Features Window Factory Settings Please use basically wi
12. Specifications Specifications Table 5 1 Functional Specifications 1 2 CPU SB303 FIT_ CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F Processor 800MHz FSB400MHz Processor 1GHz FSB400MHz Memory None 512MB 200 pin SO DIMM socket x 1 PC2100 DDR266 DDR SDRAM Video Video RAM Using main memory 64Mbyte Max Analog RGB I F x 1 15 pin HD SUB connector x 1 System resolution 1 640 x 480 800 x 600 1024 x 768 1152 x 864 1280 x 600 1280 x 720 1280 x 960 280 x 1024 1400 x 1050 1600 x 900 1600 x 1200 1856 x 1392 1920 x 1080 920 x 1200 16 770 000 colors 920 x 1440 65 536 colors Output Line OUT x 1 Stereo output level 80 200mW Signal to Noise ratio 90dB MIC x 1 Monaural Plug type 3 5 pin JACK CF CARD Type I x 1 Primary IDE Master None Finished mounting CF 2GB 1 partition CF 2GB 1 partition Equipped with the dedicated 40 pin half pitch connector Connects the CD ROM DVD ROM drive Bottom side RS 232C General purpose 2 channels 9 pin D SUB connector Baud rate 50 115 200bps Ethernet 100BASE TX 10BASE T_RJ 45 connector Built in Intel ICH4 JF N2 Ethernet 1000BASE TA100BASE TX OBASE T RJ 45 connector ntel 82541PI USB I F 4 channels USB 2 0 compliant High Full Low Speed compliant Keyboard Mouse I F None 2 F amp elT I F t can be accommodated up to 8 F amp eIT series device modules 3 4 The total power for externally connected units should not exc
13. are the same due to the screen settings while the display parameters are different For display as only one parameter can be stored for one frequency or resolution only either of Windows or MS DOS screen can be displayed properly In this case change the resolution or display frequency of Windows so that it is not the same as for the MS DOS display CONTEC CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 31 3 Functions of the Various Components CompactFlash Slot A CompactFlash compliant card slot is provided You can use TYPE I or TYPE II memory cards or microdrives that support True IDE mode Also you can boot the system from the CompactFlash hereafter referred to as CF by inserting a card containing an operating system MS DOS Windows and Linux etc Remember to format the CF before installing the OS For formatting the CompactFlash card use a USB based FDD The CPU SB303 FIT 3F CPU SB304 FIT 45F has a 2 GB CF card plugged in the slot in which Windows XP Embedded is already installed Power supply for the card Available card voltages and current values for each slot are listed below Table 3 8 Power supply for the card Current Max Not supplied 800mA Not supplied Orientation of the CF card insertion When inserting the CF card direct the backside of the CF card the side with edge of the card to Ethernet connecter side and a side with narrow groove to the eje
14. 00H is stop WDT MOV AL 00H MOV 2 MOV AL AAH OUT DX AL A CAUTION The timer s intervals have a tolerance of 2 seconds CONTEC 74 CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 6 Appendix Hardware Monitor Hardware Monitor function is included in Hardware Monitor controller Winbond W83627HG on this product You can read Temperature Voltage of this product The CD ROM F amp elIT Series Setup Disk which is bundled with this product contains a hardware monitoring utility To use the bundled hardware monitoring utility execute setup exe in APISBP SB30 Utility MTRAS Disk1 and install CONTEC Hardware Monitor Check the CONTEC s Web site http www contec com fit pagel5 htm for more information on the latest F amp eIT Series Setup Disk Temperature Two Thermistors are mounted on this product as following You can read Temperature of this position Voltage You can read 3 3V 45V VTT 1 5V Vcore of this product VTT 1 5V CPU I O voltage Vcore CPU core voltage CONTEC CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 75 6 Appendix Q amp A Common to CPU SB30 Series Can a bootable CF created on a different PC and CF used by CPU SB10 series CPU SB20 series A The setting BPB required for disk access the BIOS parameter block differ depending on the BIOS manufacturer and these are written to the CF when
15. FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 7 1 Before Using the Product Image diagram e Ferrite core adi Cable TURN 1 TURN 2 TURN 3 TURN 4 Pasting figure of IDE connector protective label Paste the attached IDE connector protective label so that the IDE connector on side of main body may be hidden CONTEC 8 CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 1 Before Using the Product FCC PART 15 Class A Notice NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference at his own expense WARNING TO USER Change or modifications not expressly approved the manufacturer can void the user s authority to operate this equipment CONTEC CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 9 1 Before Using the Product Environment Use this product in the following environment If used in an unauthorized environment the mo
16. IBM PC DOS 2000 Ver 7 0 Microsoft Windows Me TurboLinux 10Server 2 6 8 1 kernel Microsoft Windows 98 SE IBM PC DOS 2000 Ver 7 0 Linux 2 4 17 kernel 1 Verified Operating Systems Basic OS operation VGA LAN and sound driver operation has been confirmed CONTEC does not guarantee that all OS functions will operate correctly Differences other than the specification are as follows Restoring OS embedded system and installing OS are easy by equipping with the secondary IDE CF eject button is provided CF card retaining mechanism is available The DIN rail installation part can be removed The screw holes on the cabinet allow this product to be mounted on a wall using a jig without a DIN rail Precautions when Replacing CPU SB20 xxx FIT GY with This Product Hardware The physical dimensions shape weight input power supply voltage and device module connection method differ between the two products Also the PS 2 keyboard and mouse cannot be used Use both the keyboard and mouse for USB The CF card used for CPU SB2x cannot be used for this product if the card is simply inserted to it Software The watchdog setting method differs For the CPU SB30 series the Windows XP Embedded pre installed model has a single partition configuration Therefore if the EWF function is enabled data cannot be saved to a CF For that reason save any data which you need to save using storage such as a USB memory device and n
17. Specifications Physical Dimensions C d nos LP t 7 120 74 7 7 5 P 9s TIC E Em m 94 Ounum o ol Seg Ee Emm EE WE ke 315 E 8 e E mm Figure 5 2 Physical Dimensions When mounting the DIN rail installation metal fittings 4 M3 6 5 87 Including bottom side lt r2 Maximum ppr penetration p depth 5mm 0100010000001 8 orenat b SAREGAMA 8 8 42 4 20 74 7 48 TIL OUL TE Im 94 Sp He OO e e lt o LE e fe 6 M3 Maximum enetration UUUUUUUULUUUUUUUUUU depth 4mm 000 i ek zn QUU 002 B o 000 e mm Figure 5 3 Physical Dimensio
18. WDT Start but to perform WDT Start continuously at the time of a re start CONTEC CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 71 6 Appendix Q The following example is written in Intel8086 assembly language Example programming MOV 2 AL 87H OUT DX AL OUT DX AL MOV DX 2EH MOV AL 2BH OUT DX AL MOV DX 2FH MOV AL ODH OUT DX AL MOV 2 AL 07H OUT DX AL MOV 2 MOV AL 08H OUT DX AL MOV 2 MOV AL 30H OUT DX AL MOV 2 AL 01H OUT DX AL MOV 2 MOV AL F5H OUT DX AL MOV 2 72 CONTEC CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 6 Appendix MOV AL 00H OUT DX AL MOV DXJ2EH MOV AL AAH OUT DX AL 3 lt WDT START counter set and a start gt MOV DXJ2EH MOV AL 87H OUT DX AL OUT DX AL MOV DXJ2EH AL 07H OUT DX AL MOV 2 MOV AL 08H OUT DX AL MOV DX2EH MOV AL F6H OUT DX AL MOV 2 The data of an example is 15 seconds 01H 1sec FFH 255sec MOV AL OFH 0FH 15Sec MOV 2 MOV AL AAH OUT DX AL CONTEC CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 73 6 Appendix MOV 2 AL 87H OUT DX AL OUT DX AL MOV DX 2EH AL 07H OUT DX AL MOV DX 2FH MOV AL 08H OUT DX AL MOV 2 MOV AL F6H OUT DX AL MOV 2 The data of
19. it is formatted For this reason you cannot typically use a CF from another PC In addition to use CF on CPU SB30 series you must format it on CPU SB30 series and also install an OS e What should I use for the power supply A You can also use any competitor s product output 12V 24VDC sold on the market When determining the wiring layout refer to the Connection Procedure in Chapter 2 and take note of the cable size and length restrictions for both the power supply and other cables For more details on the power supply refer to Chapter5 Specifications About power supply e Battery replacement A Forclock and CMOS backup battery replacement contact your retailer 05 operating systems for which operation has been confirmed and an example of their installation procedures A The operation of the following OS s has been confirmed IBM PC DOS 2000 Version 7 0E Microsoft Windows XP Professional 2000 Professional TurboLinux 10 Server Linux 2 6 8 1 kernel Anexample of the installation procedures is included in the SB30 folder for API SBP W32 Jun 2007 or later version Can I add more memory A No You cannot add extra memory Q Is there an auto power off function that allows the device to switch off automatically after an OS such as Windows shuts down A No The power cannot be turned off automatically due to the specifications of the AT power supply However if you use a UPS with
20. 0mA Before connecting a USB device that requires high current consumption to this product make sure that the current consumption does not exceed the power capacity of the power supply unit to be used This product supports the use of a USB based floppy disk drive FDD allowing booting of various OS PC DOS boot disk Windows XP 2000 setup boot disk Booting from a USB CD ROM drive is supported For details on how to install the OS refer to the CPU SB303 FIT OS installation procedure in the bundled CD ROM F amp elT Series Setup Disk For details on the latest CPU SB303 FIT OS installation procedure visit to the CONTEC web site to download Table 3 10 USB connector B1 B4 pie 09 A1 A4 Pin No Signal name Pin No Signal name A1 USBO USB1 A2 USBO Data B2 USBI Data USBO Data B3 USB1 Data A4 USB0 GND B4 USB1 GND AN CAUTION Although the USB controller of this product is compliant with the USB 2 0 standard High Full Low Speed it may not function properly for some USB devices bus powered USB hard disk unit USB card reader etc CONTEC CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 35 3 Functions of the Various Components Fast Ethernet The system is equipped with a Fast Ethernet Network mode Transmission rate Max network path length Controller Operation at 100 Mbps requires a Catego
21. 304 FIT 400 77 For CPU SB303 FIT 3F CPU SB304 FIT 45F 78 Difference from 5 20 80 Precautions when Replacing CPU SB20 xxx FIT GY with This 81 Difference from CPU SB303 FIT Series ce e tne ree bti e tm er teas 82 CONTEC CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 1 Before Using the Product 1 Before Using the Product This section explains information you need to know about this product before you use it About the Module Operated by an OS such as Windows XP this microcontroller unit can be used as a general purpose PC or a controller for a measurement control communication device from CONTEC F amp elT Series CPU SB303 Series contains a power saving high performance Celeron M processor 800MHz 852GM chip set 512MB of DDR SDRAM memory and communication interfaces such as USB2 0 and 1000BASE T CPU SB304 Series contains a power saving high performance Celeron R M processor 1GHz 852GM chip set 512MB of DDR SDRAM memory and communication interfaces such as USB2 0 and 1000BASE T The adoption of a heat sink provides a completely naturally air conditioned fanless
22. 5 BIOS Setup inei EE OU ER ERE ane reread 45 Starting tlie Setup SCEGeD s Gee siia n o AREE a EEEN EEKE A E 46 Mentone rr 46 Keystroke Sen acini Sree eee 47 Primary S condaty Master nee etii iei RP Hed a eH EHE 48 Adyanced Menu one e erp Ee REN RR 49 Cache Memory Features s ceci ec ER ERE 50 Memory Features eiii eia te ir eer ot ES AERE ER NO ERG EXE TE EORR EE RURSUS 51 PEIL Featutes e IDE Features x Video Features 53 EAN Feature S 53 USB Features e EEE EE E R E ESE 54 Audio Features 54 Features 595 K yboard SEN P RERUM MR Eee ta entes 56 Boot Feature sssaaa Enana aE E E AE EOE Eea SE Aara aara SE t 57 CONTEC iv CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F UT mnm 61 62 5 Specifications 65 ROTE 65 Aion 68 Physical Dimensions EH EXVERI I eh t eet tiere d 69 6 Appendix 71 Watchdog Timer WDT Setting 71 Hardware Monitor Temperature M amp 76 Common to CPU SB30 Series 76 For CPU SB303 FIT CPU SB
23. 5F 4 BIOS Setup 4 BIOS Setup BIOS Setup BIOS setup sets various settings during startup When using the system for the first time be sure to run BIOS setup Once set up the specified details will be backed up This chapter describes the setup utility built into BIOS The BIOS setup screen allows you to set the time specify the boot device and make hardware settings such as settings for COM and other embedded devices CAUTION restore the default settings press F9 on the setup screen Please note that set data might not be maintained in the state that the board is not built into the system case while transporting it though set data in CMOS is backed up with the battery CONTEC CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 45 4 BIOS Setup Starting the Setup Screen To start the PhoenixBIOS Setup utility Turn on or reboot your system PhoenixBIOS displays this message Press F2 to enter SETUP Pressing F2 displays the Main Menu which looks like this Main Menu Main Advanced Security Power Health Boot Exit System Time HH MM SS System Date MM DD YYYY 1 gt Primary Master Auto 2 Primary Slave Auto Secondary Master Auto Secondary Slave Auto System Memory XxxKB Extended Memory XxxxxKB General key operation help 1 It shows Item Specific Help if the item has help information
24. D 1 Transmit receive data 1 4 TRD 2 Transmit receive data 2 5 TRD 2 Transmit receive data 2 6 TRD 1 Transmit receive data 1 7 TRD 3 Transmit receive data 3 8 TRD 3 Transmit receive data 3 LINK ACT LAN driver Install the appropriate LAN driver for your OS from the bundled CD ROM F amp elIT Series Setup Disk For more details on the latest F amp eIT Series Setup Disk check the CONTEC s web site http www contec com fit page7 htm A CAUTION Network status display LED Link status indicator Data send receive indicator In case of CPU SB304 range of operating guarantee temperature is 0 35 C when connecting the 1000BASE T If you use it in the range of 35 50 C set it to LOOBASE TX or 1OBASE T CONTEC CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 37 3 Functions of the Various Components How to set CPU SB304 as 100BASE TX or IOBASE T Windows XP 1 Click Start button 2 Click Control Panel 3 Click Performance and Maintenance 4 Click System then System Properties window is displayed 5 Click Hardware then click Device Manager 6 Click in Network adapters then double click Intel R PRO 1000 MT Network Connection 7 Click detailed setting tab then select Link speed and duplex 8 Click Link Speed tab and then select one setting from 100Mbps Full
25. Duplex 100Mbps Half Duplex 10Mbps Full Duplex or 10Mbps Half Duplex in Speed and Duplex which suits the environment for LAN connection CONTEC 38 CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F POWER This is a power supply connector Power supply 12 24VDC 5 Table 3 13 Power supply connector Connector used MC1 5 3 G 3 5 PHOENIX CONTACT Vit J Vel og 12 24VDC n Pin No Signal name Meaning 1 Vit Power supply 12 24VDC 2 Vi Power supply GND 3 FG Frame ground 3 Functions of the Various Components Applicable plug provided with module MC1 5 3 ST 3 5 Made by PHOENIX CONTACT For AWG28 16 cable The length of cable from the external power supply to the above connector must be no more than 40cm for AWG24 16 cable no more than 15cm for AWG28 and no more than 30cm for AWG26 When connecting remove approximately 7mm of insulation from the end of the cable Applya conductor tightening torque of 0 22 0 25 Nm LINE OUT The audio line OUT output Plug type 93 5 pin jack stereo Output level 80 200mW Signal to Noise ratio 90dB MIC The audio MIC Input Plug type 63 5 pin jack Sound driver Install the appropriate sound driver for your OS from the bundled CD ROM F amp eIT Series Setup Disk For more details on the latest F amp eIT Series Setup Disk check the CONTEC s w
26. F amp eIT Series F amp eIT Series Micro Controller Unit 2GB CF XP Embedded Model CPU SB303 FIT 3F CPU SB304 FIT 45F OS Uninstalled Model CPU SB303 FIT CPU SB304 FIT 400 User s Manual CONTEC CO LTD Check Your Package Thank you for purchasing the CONTEC product The product consists of the items listed below Check with the following list that your package is complete If you discover damaged or missing items contact your retailer CPU SB303 FIT 3F CPU SB303 FIT CPU SB304 FIT 45F CPU SB304 FIT 400 2GB CF XP OS Uninstalled Embedded Model ModeD Name Pes Pes Module EIE F amp eIT module fixing parts DIN rail installation metal fittings 1 set Product Configuration List CD ROM F amp elT Series Setup Disk 1 CF Card Retaining Bracket Po IDE connector protective label CompactFlash with Windows XP Embedded installed 1 END USER LICENSE AGREEMENT FOR MICROSOFT SOFTWARE Windows XP Embedded None None None None 1 The CD ROM contains various software and User s Manual this manual 2 Itis attached to CPU SB304 FIT 45F CPU SB304 FIT 400 License Agreement Notes on Windows XP Embedded Configuration images i Power connector IDE connector protection label F amp eIT module retaining fixing parts DIN rail installation bracket metal fittings M LI END USER LICEN
27. ONTEC ii CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F Table of Contents Check Your Package Copyright e ii Trademarks eere eco ie be e e ta eb ii Table OF Contents e E e Ne iii 1 Before Using the Product 1 About the Module tet PIRE ERE TREE 1 gcn 1 Verified Operating Systems eee pP REOR RED 3 Support Softwares NBN 4 List OF Options Fe M 4 Customer SUpDOft EU BER PE UESTRE ERREUR ETE REIS 3 M 5 Limited Orie Ye r Warranty 5 How to Obtam Service etre teer ri RE EDU HR EIER E MONS tee 5 Bride 5 Safety Precautions iE M 6 Salety Informations ene RR REFER E 6 Handling Precautionis inpr 6 Environment RERO NOE REDEUNT RETE Ee Ro 10 InSpecton a ER tu 10 Mitch EN 10 10 2 Hardware Setup 11 Gethin eS Carte m 11 Attaching the CF Card Retaining Bracket tnter nennen 11 Mounting Removing the Device Module sess 12 Stack Connection Locking DEVICES 12 Mounting Device Modul eves 12 Removing the Module Mounting on Removing a DIN 14 Mounti
28. SE _ Notes on AGREEMENT FOR Windows XP Module First step guide F amp eIT Series Recovery CompactFlash MICROSOFT SOFTWAR Embedded Setup Disk media N CAUTION For operating this product power supply 12 24VDC is required separately For more details on the power supply refer to Chapter5 Specifications About power supply CONTEC CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 1 Copyright Copyright 2007 CONTEC CO LTD ALL RIGHTS RESERVED No part of this document may be copied or reproduced in any form by any means without prior written consent of CONTEC CO LTD CONTEC CO LTD makes no commitment to update or keep current the information contained in this document The information in this document is subject to change without notice All relevant issues have been considered in the preparation of this document Should you notice an omission or any questionable item in this document please feel free to notify CONTEC CO LTD Regardless of the foregoing statement CONTEC assumes no responsibility for any errors that may appear in this document or for results obtained by the user as a result of using this product Trademarks F amp elT is a registered trademark of CONTEC CO LTD MS Microsoft and Windows are trademarks of Microsoft Corporation Other company and product names mentioned herein are generally trademarks or registered trademarks of their respective owners C
29. U SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 2 Hardware Setup Mounting on a DIN rail installation metal fittings 1 Pull down the DIN rail installation metal fitting lever on this product If a device module is connected push the fixing hook up using a slotted screwdriver to make it lockable this should be done on all connected device modules Figure 2 6 Mounting ona DIN rail 1 3 Press here to life the fixing hook 2 Hook the unit an object consisting of a controller and a module from the upper part of the DIN rail and press the lower part of the unit onto the DIN rail 35mm DIN rail Figure 2 6 Mounting ona DIN rail 2 3 CONTEC CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 15 2 Hardware Setup 3 Lift up the DIN rail installation fitting lever on this product Attach the bundled lever fixing screws If a device module is connected the fixing hook will be locked automatically therefore the device module can be attached with a single motion Figure 2 6 Mounting on a DIN 3 3 Removing from a DIN Rail N CAUTION To disconnect any connected device from the other modules remove all the device modules which are connected to this product from the DIN rail before
30. USB CD ROM drive or USB connected FDD For more details on this refer to USB ports in Chapter3 Functions of the Various Components Nomenclature or CPU SB303 FIT OS installation procedure the bundled CD ROM F amp eIT Series Setup Disk Check the CONTEC s Web site http www contec com fit pagel5 htm for more information on the latest F amp eIT Series Setup Disk For CPU SB303 FIT 3F CPU SB304 FIT 45F only Q Can I install to CPU SB303 FIT 3F CPU SB304 FIT 45F and use an application which was used by CPU SB21 256 FIT GY or CPU SB22 256 FIT GY Yes Youcan use a development application that uses API SBP W32 supported by CPU SB30 series It should however be noted that the application processing speed may change due to differences in the hardware specifications such as CPU If the speed change impacts the operation make some adjustments such as for the application processing method In addition please run the actual program to check its operation in order to find out how big the change actually is If you are going to use an application that was developed with API SBP W32 which is not supported by CPU SB30 series please use the May 2007 or later version after rebuilding it How long does it take for CPU SB303 FIT 3F CPU SB304 FIT 45F to boot up after the power is turned on It takes approximately 50 60 seconds when no application is installed The boot time includes the time needed for icons to appear
31. ace the product In no event will the warrantor be liable for any incidental or consequential damages due to such defect or consequences that arise from inexperienced usage misuse or malfunction of this device CONTEC CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 5 1 Before Using the Product Safety Precautions Understand the following definitions and precautions to use the product safely Safety Information This document provides safety information using the following symbols to prevent accidents resulting in injury or death and the destruction of equipment and resources Understand the meanings of these labels to operate the equipment safely A DANGER DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury Ay WARNING WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury A CAUTION CAUTION indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury or in property damage Handling Precautions DANGER Please do not use the product in environments subject to flammable and corrosive gas Otherwise it can bring on exploding fire electric shock and trouble CAUTION Do not use or store the equipment in a hot or cold place or a place that is subject to severe temperature changes Examples Under
32. an auto power off function you can let the device turn off automatically Please note that we do not provide any UPS operational information CONTEC 76 CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F e 6 Appendix Can I use any commercial CD ROM drive As the IDE connector has a special shape please use our optional CD ROM DVD ROM drive connect the optional CD ROM DVD ROM drive IPC CDD 03 to the IDE cable IPC CDC 03 which is designed specifically for this Should I note it with ON OFF of the power supply After turning off the power wait for at least five seconds before turning it back on If the power is turned on immediately after being turned off the product may malfunction Q Is it possible to display in the maximum resolution A To display in the resolution more than 1400 x 1050 you need to change Internal DDC ROM of Video Features in BIOS setting to Disabled Q Nothing is displayed on the screen A e When you boot this product in the situation that Internal DDC ROM of Video Features in BIOS setting is Disabled and the monitor cable is disconnected the screen is not displayed To display the screen press Ctrl Alt and F1 keys On rare occasions Windows does not boot when USB device is connected When USB device is connected and Legacy USB Support in BIOS setting is Enable default Windows might not be able to boot on rare occasions When Legacy USB func
33. are Setup Installation orientation Wall ceiling installation for single use The system can be installed in either orientation 5 Orientation 6 which does not lend itself to heat dissipation should be avoided In orientation 5 the system can be connected to other modules In that case however install it on a DIN rail leaving 45mm or more underneath Figure 2 9 Installation orientation Wall ceiling installation for single use CONTEC 20 CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F Spacing between the system unit and any surrounding objects 2 Hardware Setup Secure a distance of at least 50mm between the top of the main unit single use and any surrounding objects and also a distance of at least 10mm between each side of the unit and any surrounding objects To place the unit upright use the bundled rubber feet to secure a distance of at least 5 8mm underneath If a device module is connected secure a distance of at least 5 8mm at each side of the device module Do not locate the module in a fully enclosed housing This restriction does not apply if the side of the enclosure has ventilation slits next to the module 10mm 50mm 10mm or more or more or more Si
34. ated version from the CONTEC s Web site http www contec com fit page5 htm For more details on the supported OS applicable language and new information please visit the CONTEC s Web site List of Options CF Card CPU SB303 FIT CPU SB304 FIT 400 CF 1GB A 1GB CompactFlash for Fix Disk CF2GB A 2GB CompactFlash for Fix Disk CFAGB A 4GB CompactFlash for Fix Disk CF 8GB A 8GB CompactFlash for Fix Disk CD ROM DVD ROM drive IPC CDD 03 CD ROM DVD ROM drive 1 IPC CDC 03 Connection cable for CD ROM DVD drive 400mm Please purchase the optional connection cable IPC CDC 03 CONTEC 4 CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 1 Before Using the Product Customer Support CONTEC provides the following support services for you to use CONTEC products more efficiently and comfortably No driver software is provided with this module Please download the latest drivers from the CONTEC web site http www contec com Documents including important notes on the use of the module are also posted on the web site Please visit the CONTEC web site before using the module Web Site Japanese http www contec co jp English http www contec com Chinese http www contec com cn Latest product information CONTEC provides up to date information on products CONTEC also provides product manuals and various technical documents in the PDF Free download You can download updated driver soft
35. ct button of the CF slot then insert Groove wide Pin area Groove narrow A CAUTION Ifyou feel resistance when inserting the CF card it could be a wrong insertion If you further insert forcefully the CF connector and CF card could be broken When inserting in wrong orientation the CF connector and CF card could be broken CONTEC 32 CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F Secondary IDE Connector 3 Functions of the Various Components This connector allows you to connect the optional CD ROM DVD ROM drive IPC CDD 03 to the IDE cable IPC CDC 03 using the cable bundled with the drive It does not support connection to any device hard disk etc other than the optional product Table 3 9 Secondary IDE Connector Connector used 40 pin half pitch type 1 27mm pitch B20 A20 Connector used B1 SAIL Pin No Signal name Direction Pin No Signal name Direction Al RESET Output Bl GND A2 DD7 110 2 JO A3 DD6 10 B3 DD9 JO A4 DD5 4 DD10 JO A5 DD4 JO B5 DD11 JO A6 DD3 JO B6 DD12 JO AT DD2 JO B7 DD13 JO A8 DD1 vO B8 DD14 9 DDO B9 DD15 10 GND B10 N C All DDRQ Input B11 GND A12 DIOW Output B12 GND 13 DIOR Output B13 GND Al4 IOCHRDY Input B14 DALE Output 15 DDACK O
36. cting the F amp eIT series module By referring to this chapter connects the F amp eIT series module to the CPU SB30 series When using the CPU SB30 series on a standalone basis go to STEP2 STEP2 Connecting the cables Connect the cables for the CRT and other external devices to the CPU SB30 series STEP3 Turning on the power After re checking that STEPS 1 to 2 have been correctly performed turn on the power If something goes wrong after the power is turned on immediately turn off the power and make sure that the system is correctly set up Attaching the CF Card Retaining Bracket 1 After inserting a CF Card fasten the bundled CF Card retaining bracket with a screw Use the bracket especially when any vibration or impact is expected Figure 2 1 Attaching the CF Card Retaining Bracket CONTEC CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 11 2 Hardware Setup Mounting Removing the Device Module Stack Connection Locking Devices This product has two openings at the top and bottom to which the locking devices are connected Figure 2 2 Stack connection locking device Mounting the Device Module 1 Insert the stack hook by aligning it with the hook insertion inlet for the other device 2 Mount the module onto this product using the bundled F amp eIT module fixing parts If a stack connector protective cover is attached the connection operation should be performed after the cove
37. de Top Side EE 20mm or more Side 5 8mm or more Bottom 5 8mm or more Bottom 50mm or more Top e e 000 imm LCD CUOI Figure 2 10 Spacing between the module and any surrounding objects 7 2 CONTEC CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 21 2 Hardware Setup 20mm or more Side ALT TIT Ez faa vez 45mm or more Bottom 45mm or more Bottom Figure 2 10 Spacing between the module and any surrounding objects 2 2 CONTEC 22 CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 3 Functions of the Various Components 3 Functions of the Various Components
38. direct sunlight Near a heat source Do not use or store the equipment in a place that is subject to extreme humidity or dust It will be extremely dangerous to use the equipment when its interior is contaminated with water or liquid or conducting debris When using the equipment in an environment that is subject to water or conducting debris consideration should be given to the installation of a control panel with a structure that keeps dust out Do not use or store the equipment in a place that is subject to shock or vibrations Do not use or store the product near equipment generating a strong magnetic field or radio waves It may cause malfunction Do not use or store the equipment in air with diffused chemicals or in an environment in which the equipment can come into contact with chemicals When attaching or detaching a module or a connector please be sure that the power cable for the system is unplugged from the outlet Do not modify this product CONTEC will bear no responsibility for any problems etc resulting from modifying this product CONTEC 6 CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 1 Before Using the Product Ifyou notice any malfunction or abnormal conditions such or a strange odor or overheating please unplug the power cord and contact your retailer connect with peripherals use a grounded shielded cable Toclean this product gently wipe it with a sof
39. dule may overheat malfunction or cause a failure Operating temperature 0 50 Operating humidity 10 90 RH No condensation Corrosive gases None Floating dust particles Not to be excessive Inspection Inspect the product periodically as follows to use it safely Check that the bus connector of the module and its cable have been plugged correctly a afn GAN m The ventilation slits are not covered and neither dust nor alien substance is attached to the ventilation slits Storage When storing this product keep it in its original packing form 1 Put the module in the storage bag 2 Wrap it in the packing material then put it in the box 3 Store the package at room temperature at a place free from direct sunlight moisture shock vibration magnetism and static electricity Disposal When disposing of the product follow the disposal procedures stipulated under the relevant laws and municipal ordinances CONTEC 10 CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 2 Hardware Setup 2 Hardware Setup Getting Started Follow the following procedures to set up the CPU SB30 series STEPI Conne
40. e RS 232Cport COMI COM2 The system is equipped with two RS 232C compliant serial port connector This port can be set by means of BIOS setup procedures Table 3 2 SERIAL address and interrupt Factory setting 1 3F8h 3FFh IRQ 4 2 2F8h 2FFh IRQ 3 Table 3 3 Serial port connector Connector used D SUB 9 pin MALE UNC 4 40 inch screw 5 ot9 o o o o o 6 Pin No Signal name Meaning Direction 1 CD Carrier detect Input 2 RD Received data Input 3 TD Transmitted data Output 4 DTR Data terminal ready Output 5 GND Signal ground gt 6 DSR Dataset ready Input 7 RTS Request to send Output 8 CTS Clear to send Input 9 RI Ring indicator Input CONTEC CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 25 3 Functions of the Various Components I O addresses and commands The following table shows COMI addresses and commands Table 3 4 I O addresses 03F8h Transmitter holding register Receive buffer register ow penne seiner w Interrupt enable register 03FAh Ix rR Interrupt ID register 03FBh 03FCh Modem control register oarBh X R Modem status register MSR DLAB Divisor Latch Access Bit value of bit 7 of line control register CONTEC 26 CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 3 Functions of the Various Compone
41. e core should be 0 22 0 25Nm CAUTION The power supply for the device modules connected to the F amp eIT I F is supplied via the stack connector For operating this product power supply 12 24VDC is required separately For more details on the power supply refer to Chapter5 Specifications About power supply CONTEC 18 CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 2 Hardware Setup Installation Conditions Installation orientation Floor desk installation for single use The system can be installed in either orientation 1 or 2 Orientation 3 and 4 which does not lend itself to heat dissipation should be avoided If using orientation 1 do not connect any other modules If using orientation 2 other modules may be connected but ensure a clearance on the bottom side of at least 5 8mm by using the bundled rubber feet gt eae 0 CJL 10 aca gt 00000 OIL EA es 1100000 Floor Figure 2 8 Installation orientation Floor desk installation for single use N CAUTION If this product is installed with the heat sink side up direction of 1 use it in the environment that has cooling air 0 5m s CONTEC CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 19 2 Hardw
42. eb site http www contec com fit page7 htm CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 39 3 Functions of the Various Components F amp eIT I F This is F amp eIT I F connector for the F amp eIT series connection It can connect up to eight device modules The maximum power to be supplied to the F amp eIT I F is 3A Therefore make sure that the total current consumption of connected modules does not exceed 3A Also I O addresses 08xxh and 48xxh are not available due to resource restrictions to this product When a device module is used with its Device ID as 0 or 4 the I O address is 09xxh or 49xxh respectively Table 3 14 F amp eIT I F connector Connector used FX8C 808 SV HIROSE AS 808 08X4 Available connector FX8C 80P SV HIROSE CAUTION When COM 2 FIT GY and COM 1PD FIT GY are connected to this product by using the CF on Windows they cannot be used in the enhanced mode with Device ID s 4 and 5 connect three modules use Device ID s 6 and D For the Device ID setting refer to the device module manual of your own CONTEC 40 CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F Table 3 15 F amp eIT I F pin assignments No Dir Description premegon Pace c Net eonnestea ress bus 01 A gt g
43. eed 3 0 A Watch dog timer 255sec 255 level When timing up reset Hardware monitoring Monitoring of the CPU and board for the temperature and power supply voltage at a single location each RTC CMOS Life of lithium backup battery When no power supplied When power supplied 10 years or more 25 Accuracy of realtime clock less than 3 min month 25 LED Display Power CompactFlash access user programmable LED x 2 1 To display in the resolution more than 1400 x 1050 you need to changelInternal DDC ROM of Video Featureslin BIOS setting to Disabled 2 For the keyboard mouse FDD use the USB I F 3 Ensure that the sum of the maximum current consumptions for each unit does not exceed the current output of the power supply unit 4 The stack connector supplies the power to device modules Note that the maximum allowable current of the stack connector is 3 0A CONTEC CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 65 5 Specifications Table 5 1 Functional Specifications 2 2 Manual switch input Reset switch x 1 user programmable switch x 1 Power Input power voltage 12 24VDC 5 supply Max power When inputting 12V 2 4A consumption When inputting 24V 1 3 External device power Secondary IDE connector 5V 500mA supply capacity CF card slot 3 3 500mA USB 5V 2A 500mA x 4 Table 5 2 Installation environment Line Noise Linenno
44. el than the previous CPU SB20 Series products with approximately 6 time faster processing speed CONTEC CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 1 1 Before Using the Product Ultra low voltage Celeron M 1GHz 852GM chip set and 512MB of memory CPU SB304 FIT 400 CPU SB304 FIT 45F The product has a power saving high performance ultra low voltage Intel R Celeron R M processor with 1GHz FSB 400MHz Intel 852GM chip set and 512MB of memory It is a faster and functionally more advanced model than the previous CPU SB20 Series products with approximately 8 time faster processing speed The adoption of a fan less CF card configuration providing high levels of reliability and quietness The adoption of a heat sink provides a fanless environment while the use of a CF card as a storage device ensures high levels of reliability and quietness In addition from a full consideration of safety the CF card slot comes with a metal bracket to prevent the card from being accidentally disconnected A wide range of power supplies 12 24VDC supported Supporting a wide range of power supplies 12 24VDC the product can be used under various power conditions It is possible to operate by OS such as Windows CPU SB303 FIT CPU SB304 FIT 400 This product supports a variety of applications as a compact embedded controller based on Microsoft Windows XP Professional Embedded Windows 2000 L
45. enus When Set user password you select this unction the following message will appear at the center of the screen to assist you in creating a password Password on boot The setting whether or not it needs password input in system boot Fixed disk boot sector The write protection setting for the boot sector for hard disk protection from virus Diskette access Protection of password setting of the access for the floppy disk Clear all password It can eliminate all password by the supervisor Note When a password has been enabled you will be prompted to enter it every time you try to enter Setup This prevents an unauthorized person from changing any part of your system configuration Additionally when a password is enabled you can also require the BIOS to request a password every time your system is rebooted This would prevent unauthorized use of this board N CAUTION Once a password is registered even the password function itself cannot be cancelled without the password Passwords should be handled with great care CONTEC 58 CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 4 BIOS Setup Power Menu Main Advanced Security Power Health Boot Exit gt ACPI Controls Figure 4 15 Power Menu Window Factory Settings ACPI Controls ACPI detail setting s submenu ACPI Controls Main Advanced Security Power Health Boot Exit
46. environment These products enable functional expansion when an F amp eIT Series device is stack connected to the F amp elT I F This product is faster processing speed approx 6 times faster CPU SB304 approx eight times faster and functionally more advanced USB2 0 RS 232C and LAN doubled than the previous CPU SB20 Series products For more details on the differences from the conventional products refer to Chapter6 Differences from CPU SB20 xxx FIT GY Base model CPU SB303 FIT CPU SB304 FIT 400 Memory 512MB model without OS CF OS pre installed model CPU SB303 FIT 3F CPU SB304 FIT 45F Memory 512MB model with Windows Embedded CF 2GB Features Fits a PC with expansion capability into a small size 94 0 W x 120 0 D x 74 7 H Encased in a compact cabinet 94 0 W x 120 0 D x 74 7 H this product has a range of interfaces such VGA USB2 0 x 4 RS 232C x 2 LAN x 2 1000BASE T 100BASE TX audio and F amp eIT for F amp eIT Series device modules This product also has the Secondary IDE Connector that can be connected to an external CD ROM DVD ROM drive Ultra low voltage Celeron M 800MHz 852GM chip set and 512MB of memory CPU SB303 FIT CPU SB303 FIT 3F The product has a power saving high performance ultra low voltage Intel R Celeron R M processor with 800MHz FSB 400MHz Intel R 852GM chip set and 512MB of memory It is a faster and functionally more advanced mod
47. et by using pin B26 IO_RST The signal B27 CPUSEN indicates a Low level output The IRQx signal represents a signal for which the rise edge is enabled Total power ratings for the power supply pins 5 0VDC 3 0A CLK8MHz SA15 SA0 AEN IOW IOCHRDY SD7 SDO 00 8bit 520 time width Data delay time Data hold time Figure 3 2 F amp eIT I F I O write cycle CONTEC 42 CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 3 Functions of the Various Components CLK8MHz l i SA15 SA0 AEN IOR tior1 i IOCHRDY trpyl d SD7 SDO i e 8501 ns Item Code Min Max Address delay time tSA2 0 AEN delay time 1 tAEN1 IOW4 delay time 2 HOR2 100 125 IOW delay time 1 dom 100 TOW pulse width 8bit 520 IOCHRDY delay time tRDY1 2235 16bit 75 8bit 360 IOCHRDY pulse width tRDY 125 15600 Data sotup time msomi 24 Data noia time 802 Figure 3 3 F amp eIT I F read cycle IRQ unas 1 High level must be maintained until the completion of interrupt processing Figure 3 4 F amp eIT VF interrupt cycle CONTEC CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 43 3 Functions of the Various Components CONTEC 44 CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 4
48. etwork server CONTEC CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 81 6 Appendix Difference from CPU SB303 FIT Series CPU ability is raised more higher than the existing product CPU SB303 FIT clock is changed 800MHz to IGHz There is a difference between CPU SB303and CPU SB 304 in specifications CPU SB303 CPU SB304 Ultra Low Voltage Intel R Celeron R M Ultra Low Voltage Intel R Celeron R M Processor 800MHz FSB400MHz Processor 1GHz FSB400MHz CONTEC 82 CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F CPU SB30x FIT Series User s Manual CONTEC CO LTD July 2010 Edition 3 9 31 Himesato Nishiyodogawa ku Osaka 555 0025 Japan Japanese http www contec co jp English http www contec com Chinese http www contec com cn No part of this document may be copied or reproduced in any form by any means without prior written consent of CONTEC CO LTD 07232010 05292007 Management No 40 681 07232010 rev5 Parts No LYHL265
49. generated 1 high Interrupt generated on overrun parity framing error or break Interrupt cleared when the line status register is read nterrupt generated when the receive buffer register is ready Interrupt cleared when the receive buffer is read nterrupt generated when the transmitter holding register is empty Interrupt cleared when the IIR is read or transmission data is written to the THR Modem status interrupts generated CTS DSR RI CD nterrupt cleared when the modem status register is read R Line Control Register Bit table D6 D5 D4 D2 DO 0 1 STOP bit 1 1 5 STOP bits for 5 bit length 2 STOP bits for 6 7 or 8 bit length 0 Parity disable 1 Parity enable 0 Odd parity 1 Even parity 0 Stick parity disabled 1 Stick parity enabled 0 Break off 1 Break signal sent DLAB divisor latch access bit For accessing the divisor latch register set this bit to 1 For accessing any other registers set this bit to 0 CONTEC 28 CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F Table 3 5 Register functions I O address 3 Functions of the Various Components 3 3 Description 03FCh MCR Modem Control Register D7 D6 D5 D4 D3 D2 Di DO 0 0 0 Loop IRQ X RTS DTR
50. hand 1 Remove the lever fixing screws from the DIN rail installation fitting then pull down the DIN rail installation fitting lever If a device module is connected pull down the fixing hook of the device module to unlock it this should be done on all connected device modules Figure 2 7 Removing the module from the DIN 1 3 CONTEC 16 CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 2 Hardware Setup 2 With the fixing hook unlocked pull the lower part of this product toward you e Figure 2 7 Removing the module from the DIN 2 3 3 By lifting this product you can easily remove it from the DIN rail Figure 2 7 Removing the module from the DIN rail 3 3 CONTEC CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 17 2 Hardware Setup Connection Method Supplying the Power to the Controller 1 This product and a power supply unit about 50W commercial power unit are connected by using the detachable connector either on the unit or module face Use a cable no longer than 40cm AWG24 16 No longer than 15cm for AWG28 and no longer than 30cm for AWG26 Compatible cables are AWG28 16 Strip the cable jacket off about 7mm The fastening torque for the cabl
51. ing Systems Basic OS operation and VGA LAN and sound driver operation has been confirmed CONTEC does not guarantee that all OS functions will operate correctly You can build a Windows XP or Windows 2000 SP3 SP4 environment on the CPU SB303 FIT CPU SB304 FIT 400 by installing the OS using a retail USB based CD ROM drive or FDD You can also install another OS such as DOS if you prepare a retail USB CD ROM drive supported by a startup disk for the OS CAUTION It is not possible to operate by Microsoft Windows 2000 Professional in enhancement odule SMC 2DL FIT CONTEC CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 3 1 Before Using the Product Support Software You should use CONTEC support software according to your purpose and development environment Driver library API SBP W32 Available for downloading free of charge from the CONTEC web site The CPU SB30Series is the Windows version driver library software that provides products in the form of Win32 API functions DLL Various programming languages such as Visual Basic and Visual C can be used to create high speed application software which maximizes the features of the F amp eIT module In addition a diagnostic program which is useful for operation verification is also provided lt Operating environment gt OS Windows XP 2000 Me 98 etc Adaptation language Visual Visual Basic etc You can download the upd
52. inux and PC DOS Possibly used as a controller for a measurement control communication device from the F amp eIT Series This product can be used as a controller for a measurement control communication device from the F amp elT Series The measurement control communication devices which can be used include digital I O analog I O and serial communication modules Upto eight F amp eIT Series device modules can be connected to the F amp eIT I F The F amp eIT I F can accommodate up to eight F amp eIT Series device modules maximum total current of each module is 3A or less Possibly installed in 35mmDIN rail A detachable metal installation part for attaching the main unit to a 35mm DIN rail is bundled by default which can be used according to the installation conditions The system features a unique configuration for its connection to a module on the side in a stacking manner which allows you to configure the system simply and elegantly without using backplanes and other connecting devices CONTEC 2 CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 1 Before Using the Product Verified Operating Systems Operating system for which the CPU SB303 FIT CPU SB304 FIT 400 Model which has no OS operation has been confirmed is as follows Microsoft Windows XP Professional Embedded Microsoft Windows 2000 Professional BM PC DOS 2000 Ver 7 0 TurboLinux 10 Server Linux 2 6 8 1 kernel Verified Operat
53. ion regarding whether or not his partitioning tool can create partitions as such information is not available Please note that if the user makes any partition change CONTEC shall not guarantee the operation Ifthe EWF function is Enabled data cannot be written to the C drive Therefore please use USB memory device or file server to save data such as logs CONTEC CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 79 6 Appendix Difference from CPU SB20 xxx FIT GY CPU SB30 series is more advanced than the CPU SB20 xxx FIT GY Series and comes with a high speed CPU This product is different in specifications it is as follows CPU SB20 xxx FIT GY Series CPU SB22 256 FIT CPU SB21 256 FIT GY CPU SB20 256 FIT GY CPU SB20 128 FIT GY CPU SB30 series CPU SB20 256 FIT GY CPU SB20 128 FIT GY Ultra Low Voltage Intel R Celeron R M Geode SC2200 266MHz Processor 800MHz 1GHz FSB400MHz Intel R 852GM ICH4 512MB 200 pin SO DIMM socket x 1 Micro DIMM socket x 1 CPU SB22 256 FIT PC2100 DDR266 DDR SDRAM CPU SB21 256 FIT GY CPU SB20 256 FIT GY Coming standard with 256Mbyte Micro DIMM CPU SB20 128 FIT GY Coming standard with 128Mbyte Micro DIMM Built in Intel 852GM 15 pin HD SUB connector Built in CPU 15 pin HD SUB connector 640 x 640 x 480 800 x 600 1152 x 864 1280 x 600 480 800 x 600 65 536 colors 1024 x 768 65 536 1280 x 720 1280 x 960 1024 x 768 1280 x 1024 colors
54. ise 6 resistance Static electricity Atmospheric discharge 8kV IEC1000 4 2Level 3 EN61000 4 2Level 3 Vibration Sweep resistance 10 57Hz semi amplitude 0 15mm 57 150Hz 2 0G JIS C60068 2 6 compliant IEC60068 2 6 compliant 15G half sine shock for 11ms in X Y and Z directions JIS C60068 2 27 compliant IEC60068 2 27 compliant Class D grounding previous class 3 grounding 5 Ifthis product is installed with the heat sink side up use it in the environment that has cooling air 0 5m s 6 When PBA75F 24 manufactured by Cosel is used for the AC DC power supply unit 7 In case of CPU SB304 range of operating guarantee temperature is 0 35 C when connecting the 1000 If you use it in the range of 35 50 C set it to 100 or 10 CONTEC 66 CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 5 Specifications About power supply Please use the power supply in which the boot time up to 7 2V is equal to or under 25ms For the required capacity see below Input 12VDC Input 24VDC V A W W Main unit 12 2 4 28 8 unit 24 1 3 31 2 Secondary IDE 5 0 5 2 5 Secondary IDE 5 0 5 2 5 CF Slot 3 8 0 5 1 65 CF Slot 3 8 0 5 1 65 USB 5 2 10 USB 5 2 10 F amp eIT BUS 5 3 15 F amp eIT BUS 5 3 15 Total 57 95 Total 60 35 2 3 1 3 1 When the F amp eIT BUS is not used for single use it is 42 95W
55. nced Menu Window Factory Settings Reset Configuration Data Please use it with No usually There is a trouble such as OS s being not able to start with the device newly added to the system and to make it reset system configuration data ESCD and restructure make itto Yes After resetting it automatically returns to No Installed O S The operating system most frequently used is selected Large Disk Access Mode Normally set to DOS CONTEC CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 49 4 BIOS Setup APIC IO APIC Mode Enable or disable the APIC operation If you change the setting note that you have to reinstall the OS Be sure to use it in Disabled in case of the XP Embedded CPU SB303 FIT 36 and CPU SB304 FIT 456 APIC IO APIC Mode setting is corresponding to the BIOS Ver 1 21 or later Cache Memory Features Main Advanced Security Power Health Boot Exit Cache Memory Features Memory Cache Enabled Cache System BIOS area Write Protect Cache Video BIOS area Write Protect Cache BASE 0 512k Write Back Cache BASE 512k 640k Write Back Cache Extended Memory area Write Back Cache A000 AFFF Disabled Cache B000 BFFF Disabled Cache C800 CBFF Write Protect Cache CC00 CFFF Write Protect Cache D000 D3FF Disabled Cache D400 D7FF Disabled Cache D800 DBFF Disabled Cache DC00 DFFF Disabled Cache E000 E3FF
56. ng on a DIN Rail Installation Metal Fittings eese 14 Mounting on a DIN rail installation metal fittings eee 15 Removing from a DIN 16 Connection 18 Supplying the Power to the 18 Installation Conditions senor eer e eene eric tete p ene PR ERU P Rene ined 19 CONTEC CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F iii 3 Functions of the Various Components 23 Nomenclature isc Serial Port Irnt rface cese ite Displ y Interface ee RORE CompactFlash Sloths inviteiert Ret pO RR RD phe re a e i Secondary IDE CODReCtOL esito iiri b e p i er rr ERO HERE CF LED Redene er EERO Eee i epe eee e etiem POWER LED Green L1 User Programmable LED1 Red L2 User Programmable LED2 Green 34 uS W User Programmable Switch ete de pee e e e eie eerte notae eee tie 34 LS cH P 34 USB ports 35 Fast 36 Gigabit Ethernet e eR GERMAN NOU WIRE ERRARE CARO REESE CET A NC 37 POW EER ios OE EHE DEDERE ES 39 EINB OUT 39 DEDERIS us 39 VA EEEE EE OEE 40 4 BIOS Setup 4
57. ns including screw hole dimensions AN CAUTION The screw holes are located at the top and back of this product Metal fittings for installing this product directly onto a wall or other surface are not bundled nor provided as optional products When using these screw holes to install the product make your own assessment and supply such fittings yourself CONTEC CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 69 5 Specifications CONTEC 70 CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 6 Appendix 6 Appendix Watchdog Timer WDT Setting The watchdog timer serves as a safeguard against possible system lock up in your industrial computer system In most industrial environments there is heavy equipment generators high voltage power lines or power drops that have adverse effects on your computer system For instance when a power drop occurs it could cause the CPU to come to a halt state or enter into an infinite loop resulting in a system lock up The application software created by user with the watchdog timer enabled a RESET automatically generated unless the software periodically triggers the timer within the setting time out interval That is while the system gets hung up the running program can t trigger the timer periodically The timer will generate a reset signal to reboot the system This feature allows a running program to restart in an orderly way when a powe
58. nts Table3 5 Register functions 1 3 T O address 03F8h Description THR Transmitter Holding Register DLAB 0 D6 D5 D4 D2 bit7 MSB 7 Transmission data write only register RBR Reciever Buffer Register DLAB O D6 D5 D4 D2 bit7 MSB ceived data read only register Divisor Latch LSB DLAB 1 D7 06 D5 D4 D2 bit7 SB ud rate setting register LSB Divisor Latch MSB D5 bit7 MSB Baud rate setting register MSB e Register DLAB 0 D2 DO 0 EMS ELSI ERDAI L_ Received data Interrupt enabled Received data register empty Interrupt enabled Receiver line status Interrupt enabled Modem status interrupt enabled Always used at 0 1 Interrupt enabled 0 Interrupt disabled CONTEC CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 27 3 Functions of the Various Components Table 3 5 Register functions 2 3 I O address Description 03FAh IIR Interrupt Identification Register D7 D6 D5 D4 D3 D2 D1 DO 0 0 0 0 0 Interrupt contents gt 1 Interrupt not generated 0 Interrupt generated Priority Description No interrupts
59. opriate factor baud rate can be set by writing one of the values listed in the table below into the Divisor Latch Register LSB MSB Table3 6 Setting the Baud rate Baud rate to be set et in divisor register Error 2304 1536 3 0 16 Ex For a 9600bps setting write 00 7 to divisor latch register MSB and 12 dec to divisor latch register LSB CONTEC 30 CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F Display Interface 3 Functions of the Various Components The system is equipped with a connector for the Display The name of the connector is VGA HD SUB 15P Table 3 7 Display Connnector Connector used HD SUB 15 pin MALE 6 UNC 4 40 inch screw 1 11 o 5 5 07 15 10 Signal name Pin No Signal name 1 RED 9 N C 2 GREEN 10 GND 3 BLUE 11 N C 4 N C 12 N C 5 GND 13 HSYNC 6 GND 14 VSYNC 7 GND 15 N C 8 GND Display driver Install the appropriate audio driver for your OS from the bundled CD ROM F amp elIT Series Setup Disk For more details on the latest F amp eIT Series Setup Disk check the CONTEC s web site http www contec com fit page7 htm CAUTION When the analog display is used Windows MS DOS may not be properly displayed in full screen mode This is because the frequency and resolution of Windows and MS DOS full screen display
60. r Slave The Primary Secondary Master and Slave sub menus accessed from the Main Menu control these types of devices Hard disk drives CF Microdrive CD ROM drives This product supports IDE port for both primary and secondary As the CF slot is assigned to the Primary Master no drive can be connected to the Primary Slave Each IDE port supports Master drives and optional Slave drives in one of the following combinations 1 Master 2 Master 2 Master 1 Slave A CAUTION Change this setting only when an IDE drive which cannot be successfully set by the AUTO setting e g an old model that does not support automatic setting is installed CONTEC 48 CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F Advanced Menu This chapter allows you to configure your system for basic operation 4 BIOS Setup You have the opportunity to select the system s default speed boot up sequence keyboard operation shadowing and security Main Advanced Security Power PC Health Boot Exit Installed O S Large Disk Access Mode APIC IO APIC Mode gt Cache Memory Features gt Features gt PCI Features gt IDE Features gt Video Features gt LAN Features gt USB Features gt Audio Features gt IO Features gt Keyboard Features gt Boot Features Reset Configuration Data No WinXP DOS Disabled Figure 4 2 Adva
61. r glitch or any abnormal condition occurs The watchdog timer comes with 255 level time out interval 1 255 seconds per interval which can be adjusted by software setting There is a tolerance of 2 second for this time out interval To maintain the normal system operation trigger the timer periodically by the user created program in consideration of the tolerance The CD ROM F amp elIT Series Setup Disk which is bundled with this product contains a sample program for the watchdog timer To see the sample program for the watchdog timer decompress HWMandRTCut zip in APISBP SB30 Utility Samples Module Ex If the time out interval is set to 30 seconds the user created program must retrigger the watchdog timer before 28 seconds will have elapsed in consideration of the tolerance If the program failed to retrigger the timer if 28 32 seconds have elapsed the system will automatically reboot The port is defined at address 2e 2fH You can trigger enable disable the timer by writing address 2e 2fH Here is an example for flow chart and programming how to use the watch dog timer 1 Example flow chart START WDT Initial WDT Start If WDT Stop is not performed within the limit time set up by WDT Start system reset occurs When performing the re start of WDT it repeats WDT Start and Stop x It is also possible not to perform WDT Stop instead of performing WDT Stop to
62. r is removed Figure 2 3 Mounting the module CONTEC 12 CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 2 Hardware Setup Removing the Module Remove the F amp eIT module fixing parts from the top and bottom to detach the joined modules Remove the module by inserting a flat head screw driver from N these products side Too much force could breaks the plastic clip Please be careful Ne Figure 2 4 Removing the Module CONTEC CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 13 2 Hardware Setup Mounting on Removing a DIN Rail Mounting on a DIN Rail Installation Metal Fittings Mount the DIN rail installation metal fittings onto the main unit 1 Remove the three screws found at the back of the main unit Figure 2 5 Mounting on a DIN Rail Installation Metal Fittings 1 3 2 Mount the bundled DIN rail installation metal fittings with screws Figure 2 5 Mounting on a DIN Rail Installation Metal Fittings 2 3 It is recommended to use the following methods in order to reinforce the DIN rail to which this product is connected Z6 Keep the distance between screw positions short About 100mm Place square washers 22 24mm under the rail fixing screws Make sure that the heads of the screws do not touch the back of this product Figure 2 5 Mounting on a DIN Rail Installation Metal Fittings 3 3 CONTEC 14 CP
63. ry 5 cable 10 100BASE TX 10M 100Mbps 100m segment Built in ICH4 Intel Table 3 11 Ethernet connector Connector used RJ 45 Pin No Signal Meamimg 1 TD Transmitted data 2 TD Transmitted data 3 RD Received data 4 N C Not connecte 5 N C Not connecte 6 RD Received data 7 N C Not connecte 8 N C Not connecte LINK ACT LAN driver Network status display LED Link status indicator Data send receive indicator Install the appropriate LAN driver for your OS from the bundled CD ROM F amp elT Series Setup Disk For more details on the latest F amp eIT Series Setup Disk check the CONTEC s web site http www contec com fit page7 htm 36 CONTEC CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F Gigabit Ethernet The system is equipped with a Gigabit Ethernet 1000 Network mode Transmission rate Max network path length Controller 10M 100M 1000M bps 100m segment 82541PI Intel 3 Functions of the Various Components Operation at 100 Mbps requires a Category 5 or more cable Operation at 1000 Mbps requires a Category 5e or more cable Table 3 12 Gigabit Ethernet connector Connector used RJ 45 8 1 Pin No Signal name Meamimg 1 TRD 0 Transmit receive data 0 2 TRD 0 Transmit receive data 0 3 TR
64. sly saved to CMOS If you select Discard Changes in the Exit Menu all the selections will be updated and the following message will appear CMOS values have been loaded Press space to continue CONTEC 62 CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 4 BIOS Setup Load Setup Defaults To display the default values for all the Setup menus select Load Setup Defaults from the Main Menu It displays these messages Press space to continue If during boot up the BIOS program detects a problem in the integrity of values stored in CMOS it displays these messages System CMOS checksum bad run SETUP Press Fl to resume F2 to Setup The CMOS values have been corrupted or modified incorrectly perhaps by an application program that changes data stored in CMOS Press F1 to resume the boot or F2 to run Setup with the ROM default values already loaded into the menus You can make other changes before saving the values to CMOS Discard Changes Restore the contents saved previously to CMOS Save Changes Selecting Save Changes saves all the selections without exiting Setup You can return to the other menus if you want to review and change your selections CONTEC CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 63 4 BIOS Setup CONTEC 64 CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 5 Specifications 5
65. t gt gt gt gt gt Reserve Data bus 00 Data bus 02 Data bus 04 Data bus 06 Data bus 08 Data bus 10 Data bus 12 Data bus 14 gt Ground Address enable signal Read signal Write signal Ground Bus clock Ground Wait signal Ground ISA signal Interrupt signal Reserved A33 A34 A35 A36 A387 A38 A39 A40 IN OUT ISA SBHE signal Reserved Reserved Reserved 5 0 power supply 5 0 power supply 5 0 power supply Reserve 5 0V power supply 3 Functions of the Various Components No Dir Description Bo vic ST_x86 D dress dress dress dress dress gt 1 12 8 idi z 5 4 J ojo gJ J gt T D11 D13 D15 ND IOCHCK IRQ7 IRQ5 GND 10_RST CPUSEN GND GND RESERVED RESERVED RESERVED wis leo eck Rev oja ies ul B21 B22 B23 B24 B25 B26 B27 B28 B29 B30 B31 B32 B33 B34 B35 B36 B37 B38 B39 40 I N N UT UT RESERVED RESERVED RESERVED e Q un m 2 CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 3 Functions of the Various Components Remarks The symbol at the end of an item represents negative logic In an I O module normally a pin is res
66. t cloth soaked with water or a neutral detergent Do not use benzene a thinner or other volatile solvents as they can cause the coating to discolor or peel off Life of the components Battery A primary lithium battery is used to back up the internal clock calendar and the CMOS RAM When the power is not drawn and the battery is stored at 25 C it will last over 10 years For changing a battery contact your retailer Regarding PART 15 Class A Notice The ferrite core must be installed in the following each cable so that this product may suit the above mentioned standard Leave Secondary IDE pins unconnected CPU SB303 FIT CPU SB303 FIT 3F LAN 100M Eo4SR301334 SEIWA LAN1000M E04SR301334 SEIWA LINE OUT EO4SR200935A SEIWA Eo4SR200935A SEIWA POWER EO4SR200935A SEIWA E04SR301334 SEIWA CPU SB304 FIT 400 CPU SB304 FIT 45F LINEOUT E04SR170730A sEIWA E04SR170730A_ SEIWA POWER E04SR401938 SEIWA Regarding EMC Instruction Class A Notice The ferrite core must be installed in the following each cable so that CPU SB304 FIT Series may suit the above mentioned standard CPU SB303 FIT Series does not support the CE standard Paste the attached IDE connector protective label to the secondary IDE CPU SB304 FIT 400 CPU SB304 FIT 45F MONITOR E04SR170730A_ SEIWA D 1 1 0458170730 __ SEIWA e n LINEOUT E04SR170730A SEIWA POWER E04SR401938 SEIWA CONTEC CPU SB303
67. t support Plug and Play it may be necessary to set them up manually Some systems manage their communication devices using their chipset while others have separate I O chips on their CPU board to set and manage such devices Use the following chart to configure the Input Output settings Serial port i Disabled turns off the port Serial port B Enabled requires you to enter the base Input Output address and the Interrupt number on the next line Serial port A COMI Serial portB COM2 Base I O Address 3F8 IRQ4 When Enabled is selected one of these combinations is selected IRQ 2F8 IRQ3 CONTEC CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 55 4 BIOS Setup Keyboard Features Main Advanced Security Power Health Boot Exit Keyboard Features Keyboard check Disabled Num Lock On Key Click Disabled Keyboard auto repeat rate 30 sec Keyboard auto repeat delay 1 2 sec Figure 4 12 Keyboard Features Window Factory Settings Enabled Num Lock 2 On or Off turns NumLock on or off at boot up Auto turns NumLock on if it finds a numeric key pad Key Click Disabled Turns audible key click on Enabled Keyboard auto repeat 30 sec Sets the number of times a second to repeat a keystroke 26 7 sec when you hold the key down 21 8 sec 18 5 sec 13 3 sec 10 sec 6 sec 2 sec Keyboard auto repeat 1 4 sec Sets the delay time after
68. th default setting Use the Legacy USB Support during installation when necessary Legacy USB Support setting is supported from BIOS Ver 1 11 and later ERB Device 20 rio Disabled Enabled or disables the USB2 0 Enabled Legacy USB Support Disabled Enabled or disables the Legacy USB Enabled Audio Features Main Advanced Security Power PC_Health Boot Exit Audio Features AC97A Device 31 Function 5 Enabled Figure 4 10 Audio Features Window Factory Settings Please use it basically by the default setting AC97A Device 31 Function 5 Enables disables the chipset Audio device setting CONTEC 54 CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 4 BIOS Setup T O Features Main Advanced Security Power Health Boot Exit IO Features Serial port A Enabled Base I O address 328 Interrupt IRQ 4 Serial port B Enabled Base I O address 2 8 Interrupt 3 Figure 4 11 10 Features Window Factory Settings The CPU communicates with external devices such as printer through devices called Input Output I O ports such as serial and parallel ports Theses I O devices require the use of system resources such as T O addresses and interrupt lines If the devices support Plug and Play ports can be assigned to them during posting by BIOS as well as the Operating System If the I O devices do no
69. the key is held down before it begins to repeat the keystroke CONTEC 56 CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 4 BIOS Setup Boot Features Main Advanced Security Power Health Boot Exit Boot Features Summary screen Disabled Boot time Diagnostic Screen Disabled QuickBoot Mode Disabled Date Time check Enabled Figure 4 13 Boot Features Window Factory Settings Summary Screen Disabled Displays system summary screen during boot up ta pe QuickBoot Mode Disab Enabled skips some POST tests speeding boot time ee ee ee ee led e diagnostic Screen Enable Date Time check Disabled Select to check the RTC Date Time setting during boot up pu Eee CONTEC CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 57 4 BIOS Setup Security Menu Main Advanced Security Power Health Boot Exit Set Supervisor Password Enter Set User Password Enter Supervisor Password Is Clear User Password Is Clear Password on boot Disabled Fixed disk boot sector Normal Diskette access Supervisor Clear Password Enter Figure 4 14 Security Menu Window Factory Settings Feature Description Set supervisor You can enter and change the options of the setup menus password Just can only enter but do not have the right to change the options of the setup m
70. tion is Disable this event does not happen since this is caused by Legacy USB function If this event happens make Legacy USB support in BIOS setting Disable Setting of Legacy USB Support is supported from BIOS Ver 1 11 and later the version is equal to or under BIOS Ver 1 10 you need to upgrade BIOS Please contact your retailer for the BIOS upgrade For CPU SB303 FIT CPU SB304 FIT 400 only e e CONTEC Do you have a list of operating systems for which operation has been confirmed A list is posted on the CONTEC web site at http www contec com fit Please download the latest drivers from the web site As documents including important notes on the use of the module are also posted on the web site please visit the CONTEC web site before using the module Which brands of CF can I use The requirement is that the CF supports True IDE mode As some low price brands of CompactFlash do not support True IDE mode please check with the manufacturer or agent before purchasing CONTEC recommends you use CF made by Transcend Corporation The operation of the following CF s has been tested on CPU SB30 series Transcend 1GB TS1GCF45I D TS1GCF1001 Transcend 2GB TS2GCF45I D TS2GCF1001 Transcend 4GB TS4GCF451I D TS4GCF1001 Transcend 8GB TS8GCF45I D TS8GCF1001 CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F TT 6 Appendix e How can I install an OS in a CF card You can install using a
71. ttempt to load the operating system from the drive of your choice If it cannot find the operating system on that drive it will attempt to load it from one or more other drives in the order specified in the Boot Menu AN CAUTION When specifying a boot device in the Boot Menu make sure that the Operating System is installed to the selected device In most cases the Operating System is preinstalled on the hard drive C which is often used as the OS for booting purposes To use a different drive as a bootable drive the OS may need to be installed on the relevant drive Selecting Boot from the Menu Bar displays the Boot menu which looks like this Main Advanced Security Power Health Boot Exit Removable Devices Hard Drive CD ROM Network Boot Figure 4 19 Boot Menu Window You can arrange the boot order list at the top of this menu to specify the order of the devices from which the BIOS will attempt to boot the Operating System To move a device first select it with the up or down arrows and move it up or down using the lt gt and lt gt keys A CAUTION When more than one hard drive or removable drive is used use the boot order list to specify the drive to be used from the sub menu For more details on this refer to the next page CONTEC CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 61 4 BIOS Setup Exit Menu
72. utput B15 GND A16 INTRQ Input B16 NC 17 DA1 Output B17 NC wee A18 DAO Output B18 DA2 Output A19 CSr Output B19 CS3 Output A20 DACT Output B20 GND CONTEC CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 33 3 Functions of the Various Components CF LED Red Illuminates when the CompactFlash is accessed Note that there is some variation between the specifications of CompactFlash cards If you use a card with different specifications the LED may not illuminate or may remain permanently illuminated POWER LED Green Illuminates when the power is turned on L1 User Programmable LED1 Red Writing 1 to bit O of IO port 8800H illuminates the L1 LED red Reading the IO port state is also permitted L2 User Programmable LED2 Green Writing 1 to bit O of IO port 8801H illuminates the L2 LED green Reading the IO port state is also permitted uSW User Programmable Switch Reading bit 0 of IO port 8802H indicates the switch state value of 1 indicates the switch is pressed and 0 indicates no pressed This IO port bit is read only RESET SW Pressing this button triggers a reset CONTEC 34 CPU SB303 FIT CPU SB303 FIT 3F CPU SB304 FIT 400 CPU SB304 FIT 45F 3 Functions of the Various Components USB ports The system is provided with four USB interfaces compliant with the USB 2 0 standard High Full Low Speed The power supply capacity for each port is 50
73. ware and differential files as well as sample programs available in several languages Note For product information Contact your retailer if you have any technical question about a CONTEC product or need its price delivery time or estimate information Limited One Year Warranty CONTEC products are warranted by CONTEC CO LTD to be free from defects in material and workmanship for up to one year from the date of purchase by the original purchaser Repair will be free of charge only when this device is returned freight prepaid with a copy of the original invoice and a Return Merchandise Authorization to the distributor or the CONTEC group office from which it was purchased This warranty is not applicable for scratches or normal wear but only for the electronic circuitry and original modules The warranty is not applicable if the device has been tampered with or damaged through abuse mistreatment neglect or unreasonable use or if the original invoice is not included in which case repairs will be considered beyond the warranty policy How to Obtain Service For replacement or repair return the device freight prepaid with a copy of the original invoice Please obtain a Return Merchandise Authorization number RMA from the CONTEC group office where you purchased before returning any product No product will be accepted by CONTEC group without the RMA number Liability The obligation of the warrantor is solely to repair or repl
Download Pdf Manuals
Related Search
Related Contents
MT3100 - MT3200 - Automotive Equipment Svc Co Inc Motorola DCT2000 Cable Box User Manual Case Logic INS-3 Model #: 514 INSTALLATION AND OPERATING MANUAL (All versions) Istruzioni per l`uso Détecteur technique universel Detector técnico Samsung BD-P2500 Blu-ray Felhasználói kézikönyv HP hn200p User's Manual Copyright © All rights reserved.
Failed to retrieve file