1. Our complete range of specialist infusion devices Ambulatory Syringe Pump Ambulatory Syringe Pump Pain Management Syringe Pump Ambulatory Infusion Pump Twin Channel Infusion Pump Epidural Infusi n Management Infusion Pump ue Regional Analgesia Infus For more information please contact us using the details below Head Office Southern Office Kincraig Business Park Milton Park Innovation Centre CI e IO l C Kincraig Road Office 217 99 Milton Park Li Dayal Deli Blackpool FY2 oPJ Abingdon OX14 4RY isten gt Develop gt Deliver Fax 01253 896648 Fax 08704416093 g Central Switchboard email info cmemedical co uk 4 INVESTORS 01253 894646 www cmemedical co uk IN PEOPLE MKGT34GEN12
2. Ambulatory Syringe Pump gt cme medical a _ gt With Barrel arm down and no syringe in place Press and Hold C key until START UP screen appears 34 2 Wait until Pre Loading has finished actuator stops moving md 3 Load Syringe Confirm at syringe size and brand B or ao change Real and confir tow nc prompts to volumne duration or volume rate step 4 not applicable if Program Summary 5 ALWAYS check data on the summary matches Prescription before pressing ij key to F Press B key to start infusion NOTE nma press E key to show infusion data REF 300 0415 REV J LOT 5033 7 ey bhi Lid FF S ON OFF Aet 000000000 Rev 0 Lat 0000 0 A small safe reliable and user friendly device suitable for inpatient and outpatient use in a variety of applications cme medical Listen gt Develop gt Deliver The T34 Ambulatory Syringe Pump is accurate reliable user friendly and meets all of the NPSA requirements for Safer Ambulatory Syringe Drivers RRRo19 Applications e Medications analgesics e Palliative care Brittle Asthma e Chemotherapy e General fluid replacement Intended use e Intravenous e Subcutaneous e Percutaneous e Epidural in close proximity to nerves e Intra operative site e Intra arterial When you need an accurate and reliable system which is configurable to a range of applications e Automatic calculation of syringe volu
3. patients Set up instructions are on a label on the front of the pump During operation pump displays time remaining flow rate and a pump operating indication Info key displays volume infused volume to be infused and battery level to allow quick and easy checks e The digital descriptive display guides you step by step throughout the use of the pump When you need a pump that s flexible enough to use on the move and with a range of patients e Suitable for both bedside and ambulatory use e Powered by1x 9V disposable battery recommended rechargeable batteries can also be used e Can be used with most common syringe brands and sizes up to 50ml e Suitable for adult and paediatric use When you need a pump which offers your patients a host of benefits e Your patient will have complete freedom to ambulate during infusion carry pouches are available for easy transportation e Intuitive operation and display features will help your patient to understand their medication and to make basic operational changes Homecare patients will benefit from quick and easy set up functionality e The small and discreet design will give your patient dignity e Built in safety features will instil confidence in your patient knowing they are receiving a high level of care 01253 894646 marketing cmemedical co uk www cmemedical co uk ey Supporting information If you are formulating a Purchasing for Safety Initiative for Safer Ambulatory Sy
4. ion rate calculation in ml hour eliminates the need for manual measurement or rate calculation e Dedicated key operated lockboxes are available to protect the pump syringe and contents from damage or tampering e A comprehensive range of user manuals and RCN accredited training materials are provided to ensure accurate and safe use of the device 01253 894646 marketing cmemedical co uk www cmemedical co uk Pump and accessories Parts Parts Product code Description included description SBOMT34A T34 Syringe Pump and 100 100SM T34 Syringe Pump User Manual 100 090PLANET T34 User Manual SBOMT34DOCKB T34 Docking Station 150 312S T34 Docking Station Mains PSU including RS232 150 311CPC RS232 Lead lead 150 312CPC T34 Docking Station Power Supply 12V 150 755X 134 Docking Station AC Mains Adapter 2x9V BCS88 BodyComm 88 Software SBOMT34DOCKC 134 Docking Station 2x9V 150 312S T34 Docking Station including RS232 Lead 130 050X2 T34 Docking Station Battery Adapter 2x9V 150 311CPC RS232 Lead BCS88 BodyComm 88 Software SBOMT34EA T34 Syringe Pump 100 200PSM T34 Syringe Pump with Extended Memory and Extended Memory User Manual 100 O9OPLANET T34 User Manual SBOMT34LOC Lockbox clear including 100 174SA T34 Lockbox clear 2 keys 170 002X Lockbox key x 2 SBOMT34LOCYEL Lockbox yellow tint 100 174SE T34 Lockbox yellow tint including 2 keys 170 002X Lockbox key x 2 198 201 Car
5. ion software programme which enables efficient and flexible management of all infusion ees 2 3 protocols stored in your T34 Ambulatory Syringe Pump i i j i iio ij FE H it E 2 Use BodyComm to Hit Hi 533 Fes e Download save and print a record of the last 512 sequential iif H t iti t stored events including alarms from your pump event log for FE H une ji display in text and graphic format i sla A HEUL 4 Data captured for each event Ps t A Date amp time e Rate T n e Volume infused e Volume to be infused w Event number e Position of the actuator tai iy W Time duration Syringe type and size n fs 5 3 4 v m e Length of travel Alarm mmHg o 8 i mm versus ml e Battery voltage level Technical specifications Type Syringe pump with motor driven linear actuator PE Postel amit in o o1ml Ue 10 650ml hr in iml increments up to 1 000mI hr available Accuracy 5 system accuracy Syringe sizes Accommodates most syringe brands from 2ml to 50ml Battery 9V alkaline IEC 6LR61 type Battery operation Approximately seven full infusions Alarms The T34 will alarm for the following problems e Occlusion or syringe empty e Pump paused too long e End programme e End battery Syringe displaced e Syringe empty Dimensions 169 X 53 X 23mm Weight 210g without battery 274g with battery 01253 894646 marketing cmemedical co uk www cmemedical co uk
6. me and depending on mode of operation can deliver contents over a specified duration or as ml hour Lockable ml hour setting rate setting suitable for homecare use The Post Occlusion Bolus Reduction System will safely equalise pressure in the line following an occlusion without administering a potential post occlusion bolus e Configurable occlusion pressures for different clinical applications and therapies e Four configurable modes of operation available to suit specific applications o Lockon o Lock off o Rate mode o Rate setting Ee 01253 894646 marketing cmemedical co uk www cmemedical co uk When you need a safety enhanced system which meets all of the NPSA requirements Three point automatic syringe detection and recognition system allows you to quickly and easily set up the pump and will detect most commonly used syringe brands e The built in event log automatically records date and time stamped key presses alarms and errors A lockable keypad prevents most inadvertent key presses Code protected functions only allow authorised personnel to change settings Automatic alarms will draw immediate attention to any pump status requiring intervention e Administer small volumes with high levels of accuracy e Latex free dedicated administration lines with very small priming volumes anti siphon valves and anti kink tubing are available When you need a system which is quick and easy to use allowing you more time for your
7. ringe Drivers the information below will help you to see how the T34 Ambulatory Syringe Pump can help you to meet and exceed the NPSA requirements for risk reduction NPSA 2010 RRRo19 PURCHASING FOR SAFETY INITIATIVE CHECKLIST Required Safety feature 134 feature Rate settings in millilitres ml per hour Automatic calculation of infusion rate and volume in ml hour Mechanisms to stop infusion if the syringe is not properly or securely fitted Three point syringe detection system Alarms that activate if the syringe is removed before the infusion is stopped Immediate syringe displacement alarm which will halt infusion until resolved Lockbox covers and or lock out controlled by password Dedicated key operated lockboxes available plus code protected programmes locked into the pump and a lockable keypad Provision of internal log memory to record all pump events The last 512 sequential events are recorded in the pump event log and can be downloaded to a PC using our own configuration software BodyComm DURING TRANSITION You can depend on a collaborative approach from us to ensure a safe and successful implementation of your new T34 Ambulatory Syringe Pump e Our clinical specialists will assess your training needs and design and implement a training programme that is specific to your needs fit for purpose and achieves your training objectives DURING INFUSION e Automatic infus
8. ry pouch for pump and lockbox single patient use 100 176s Carry pouch for pump and lockbox reusable 100 177S Carry pouch for pump only reusable Administration sets Product Pump Patient Prime Free flow code Colour connection connection Length volume safety 100 1728 Clear Femaleluerlock Maleluerlock 100cm o 5ml Anti siphon valve 100 1708 Clear Female luer lock 25g butterfly 100cm o 5ml Anti siphon needle valve 100 172SB_ Blue Female luer lock Maleluerlock 200cm o 7ml Anti siphon valve amp clamp 100 172SE Yellow Femaleluerlock Maleluerlock 100cm o 5ml Anti siphon valve 100 172SC Blue Female luer lock Maleluerlock 170cm 1 0ml Anti siphon valve Y connector amp clamp 01253 894646 marketing cmemedical co uk www cmemedical co uk CME Support by your side throughout Technical support Your technical support needs are our priority As an ISO 13485 certified support facility we can offer you high quality technical support and training with services developed by our customers for our customers You and your team will benefit from market leading technical training and support services We will work with you to ensure you receive the best possible service package for your needs TRAINING Your role as Biomedical Engineer in supporting and maintaining these sophisticated devices is a very important one That is why we offer a range of technical training courses and materials which are designed to give yo
9. u the knowledge and skills to expertly support your chosen devices EQUIPMENT REPAIR AND SERVICING Our team of highly skilled engineers will support you by ensuring competitive turnaround times Prompt spare parts order fulfilment is guaranteed by our significant stockholding capability SERVICE CONTRACTS When entering into a service contract with CME Medical a partnership is formed to ensure your requirements are identified and addressed from the outset Clinical support You and your team need the confidence to competently and safely operate your chosen infusion devices That is why we have developed a range of education programmes which are based on current and well established principles of learning and training strategies and which follow national standards for medical device training Your competency based training can be delivered either face to face or via e learning We can offer both at the point of purchase and periodically as required Your dedicated Clinical Support Specialist will work with you to develop a training plan which is tailored to your local needs fit for purpose and which will help you to achieve your training objectives Emphasis will be placed on intensive training for your advanced users allowing you to take control of your own cascade training as your organisation goes forward 01253 894646 marketing cmemedical co uk www cmemedical co uk BodyComm l i i BodyComm is an easy to use configurat