Split Air Conditioner
Contents
1. Space to the floor 4 Z Space to the obstruction Ocm Above fl bi Nr l Air inlet side u poca Now Space 16 the wall Space to the wall L a A i WA N Spa e to ihe wall N lt 50cm Above gt A h Ny W Air outlet side Air outlet side Space to the wall lt 50cm Above gt a 19 Install indoor unit C Install the rear panel 1 Alwavs mount the rear panel horizontallv Due to the water trav of indoor unit has been adopted the both way drainage design the outlet of water tray should be adjusted slightly down when installing that is taking the outlet of the water tray as the center of a circle the included angle between the evaporator and level should be 0 or more that is good for condensing water drainage i i Wall Wall 2 Fix the rear panel on the wall with screws Wa Mark on the middle ofit __ Gradienter Y Where is pre covered with plastic granula ace Space 3 Be sure that the rear panel has been fixed SS EE wall 150mm firmly enough to withstand the weight of an above i Jt above adult of 60kg further more the weight should Ni be evenly shared by each screw j c l L bii aD b 7 Right 55mm Rear piping hole Rear piping hole Install the piping hole Indoor Outdoor Make the piping hole b55 in the wall at a slight downward slan
2. The snow guard shall be wider than the air conditioner TITTTITITTVITTITIVITITITTTTTTTITIT IT TTT Height of base in consideration of snow More than 50cm 25 GREE ELECTRIC APPLIANCES INC OF ZHUHAI Add West Jinji Rd Qianshan Zhuhai Guangdong China 519070 Tel 86 756 8522218 Fax 86 756 8669426 E mail gree gree com cn www gree com 66162760
3. Models Air switch capacity 09K 16A 12K 16A Note e Make sure that the Live wire or Zero line as well as the earth wire in the family power socket can not be wrong connected there should be reliable and no short circuit in the diagram e wrong connection may cause fire Earthing requirements 1 Air conditioner is tvpe l electric appliance thus please do conduct reliable earthing measure 2 The vellow green two color wire in air conditioner is earthing wire and cannot be used for other propose It cannot be cut off and be fix it by screw otherwise it would cause electric shock 3 The earth resistance should accord to the National Criterion 4 The user power must offer the reliable earthing terminal Please don t connect the earthing wire with the following place DTap water pipe Gas pipe 8 Contamination pipe 4 Other places that professional personnel consider them unreliable 5 The model and rating values for fuses according the silk print on fuse cover or related PCB board 18 Installation dimension diagram a C Installation dimension diagram ae ae ia Space to the ceiling 415cm Above ee l Space to the wall LL Mooc Above i s __ Air outlet side e The dimensions of the space necessary for correct installation of the appliance including the minimum permissible distances to adjacent structures
4. press this key once again to fix the time then remote controller will send out the signal immediately and hour on off will stop flickering If the time of that no press timer button under flickering status is above 5s the timer setting will quit If the timer has been set press this button once again to quit it ZINN Left and right swing button eThere is no this function for this unit If press this key the main unit will click but it also runs under original status Operation of wireless remote control 4 Names and functions of remote control buttons NOTE This remote control is universal it could be used formanv units some buttons of this control which are not available to this unit will not be described below FAN AUTO aml OPER AIR HEALTH X FAN hl T FILTER mace PA al D T Remote control TEMP JTIMER SLEEP JLIGHT SLEEP Sleep button e Press this button enter into SLEEP state when repressed it will quit The sleep function will be canceled with the stop of the unit There is no SLEEP function under AUTO and FAN mode is the icon for sleep function At COOL DRY mode the SLEEP mode runs after 1hour the setting temp will be increased by 1C 2 hour later setting temp will be increased by 2 C and then will run at this setting temperature At HEAT mode the SLEEP mode runs after 1hour the s
5. GREE Change for Life Owner s Manual Residential Air Conditioners iRvexrep Thank you for choosing Residential Air Conditioners please read this owne manual carefully before operation and retain it for future reference GWHO9KF K3DNA6B GWCO9KF K3DNA5A GWHO9KF K3DNA5A GWCO9KF K3DNA5D GWHO9KF K3DNA9A GWCO9KF K3DNA6A GWHO9KF K3DNA6A GWHO9KF K3DNA5B GWHO9KF K3DNB1A GWHO9KF K3DNA7A GWCO9KF K3DNA7A GWCO9KF D3DNA7A GWCO9KF K3DNA9A GWHO9KF K3DNB3A GWHO9KF K3DNB2A GWCO9KF K3DNB2A GWH12KF K3DNB2A GWH12KF K3DNA7A GWH12KF K3DNA5SA GWH12KF K3DNA9A GWC12KF K3DNA5A GWC12KF K3DNA5D GWC12KF K3DNA6A GWH12KF K3DNA5B GWH12KF K3DNA6A GWH12KF K3DNB1A GWH12KF K3DNA6B GWC12KF D3DNA7A GWC12KF K3DNA7A GWC12KF K3DNA9A GWH12KF K3DNB3A GWC12KF K3DNB2A GWH12KF K3DNB1B CONTENTS Operation and maintenance Notices for operation Notices for use Names and functions of each part Emergency operation Clean and care E o E mg Operation of wireless remote control m o a Troubleshooting Installation service Notices for installation Installation dimension diagram Install indoor unit Check after installation and test operation a L 0 m Install outdoor unit L m Installation and Maintenance of Healthy Filter a Install snow guard Optional Va This symbol stands for the items This symbol stands for the items C should be forbidden should be followed The products in this manual mav be differe
6. Press this button the unit will be started or stopped 7 Simpleness swing mode is defaulted for wireless which can clear the timer or sleeping function of remote controlin this mode press thisb tton ping could turn on or turn off the Up and down last time swing function MODE When unit is turned off synchronously press Mode button and Up and down swing buttons it could Press this button the running mode will change as be switched between the simpleness swing below mode and stationary swing mode at this time N A blinks 2 seconds X e In Stationarv swing mode press this button the A AUTO angle for Up and down swing as show in below oh COOL gt ie lec i DRY 4 ey FAN orF d mi e When up and down swing louver is working XX HEAT Only for cooling and heating unit when tum off the unit the siwng louver will As for cooling only unit it won t have i w N A action when it receives the signal immediatelv stop at current position gt of heating operation shows up and down swing louver swings back and forth as show in the above figure Operation of wireless remote control Names and functions of remote control buttons NOTE This Remote control is universal it could be used formany units some buttons of this control which are not available to this unit will not be described below FAN AUTO aml OPER
7. Having set X FAN function on After turning off the unit bv pressing ON OFF button indoor fan will continue running for about 10 min at low speed In this period press X FAN button to stop indoor fan directly 2 Having set X FAN function off After turning off the unit by pressing ON OFF button the complete unit will be off directly Operation of wireless remote control jk About AUTO RUN When AUTO RUN mode is selected the setting temperature will not be displaved on the LOD the unit will be in accordance with the room temp automaticallv to select the suitable running method and to make ambient comfortable jk About turbo function If start this function the unit will run at super high fan speed to cool or heat quickly so that the ambient temp approachs the preset temp as soon as possible jk About lock Press and buttons simultaneously to lock or unlock the keyboard If the remote controller is locked the icon jg will be displayed on it in which case press any button the mark will flicker for three times If the keyboard is unlocked the mark will disappear jk About switch between Fahrenheit and Centigrade Under status of unit off press MODE and buttons simultaneously to switch C and F About new function of defrosting It indicates after starting this function by remote controller and the unit has been under defrost status If turn off the unit by remote controller the unit will not stop defrosting until
8. filter commonly has its usage lifetime for one year under normal condition As for silver ion filter it is invalid when its surface becomes black green e This supplementary instruction is provided for reference to the unit with healthy filter If the graphics provided herein is different from the physical goods the latter one shall prevail The quantity of healthy filters shall be based on the actual delivery 24 Install snow guard Optional Installation method of snow guard In consideration of snow during installation of outdoor units Note It is required to equip snow guard and a higher foundation base to prevent snow from covering air inlet and outlet Correct Incorrect The snow guard shall be wider than the air conditioner wl 3NOQ wo Aa seasonal wind BODJE cpg JOU ARAREMAR 100cm Above Snow guard Provide at field BA ig More than 50cm 7777 777 77T7777777777T 77 77 Height of base in consideration of snow More than 50cm 3 Snow guard Install in windward side Windward side E gt Sa
9. it is finished if change setting mode by remote controller the function which is set last time won t be carried out until defrosting finished Operation of this function on or off If remote controller is under off status press mode button and X FAN button simultaneously in order to enter or cancel this new function If the unit is under defrost mode dual eight position on remote controller will display H1 If switch to heat mode the position will display H1 which flickers for 5s in which case press button H1 will disappear and setting temp be displayed After remote controller is powered on the new defrost function will be defaulted to be closed Changing batteries and notices 1 Slightly to press the place with 2 along the arrowhead direction to push the back cover of wireless remote control As show in figure 2 Take out the old batteries As show in figure 3 Insert two new AAA1 5V dry batteries and pay attention to the polarity As show in figure 4 Attach the back cover of wireless remote control As show in figure K NOTE When changing the batteries do not use the old or different batteries otherwise it can cause the malfunction of the wireless remote control if the wireless remote control will not be used for a long time please take them out and don t let the leakage liquid damage the wireless remote control The operation should be in its receiving range It should be placed at wh
10. warm water the water with the neutral detergent should below 45 degree and dry it in the shade NOTE Never use water above 45 to clean or it can cause deformation or discoloration Never parch it by fire or can cause a fire or deformation Insert the air filter Reinsert the filters along the direction of arrowhead and then to cover the cover and clasp it 12 Clean and care C Check before use 0 Be sure that nothing obstructs the air outlet and intake vents 6 Check that whether ground wire is properly connected or not B Check that whether the batteries of air conditioner are changed or not 1 Check that whether the installation stand of the outdoor unit is damaged or not If damaged please contact the dealer C Maintain after use D Turn main power off O Clean the filter and indoor and outdoor units bodies B Clear dust and obstructions from the outdoor unit Repaint the rubiginous place on the outdoor unit to prevent it from spreading 8 Adopt the special shield to cover the outdoor unit avoid the rain water dust enter into the unit and get rust 13 Troubleshooting A CAUTION Don t attempt to repair the air conditioner by yourself it can cause an electric shock or fire Please check the following items before asking for repair it can save your time and money Phenomenon Troubleshooting Not operate immediately when the air condit
11. AIR HEALTH X FAN go sj MOY F Ta FILTER amgen 7 h ki JIL K Remote control HEALTHISAVE X FAN TEMP TURBO SLEEP TIMER LIGHT HEALTHSN Health save button HEALTH function there is no this function for this unit If press this key the main unit will click but it also runs under original status e Save energy function Under Cool mode press the right part of this button the remote control will display SE the whole unit will enter into Electricity Save mode repress this button the whole unit will quit this mode other mode button is not available Under the EnergySave mode the Temperature and the Fan speed on the remote control are not adjustable TURBO Turbo button e Set turbo on or off the characters of turbo will appear or disappear by pressing this key under cooling or heating mode Once energized the unit will be defaulted to be turbo off This function can not be set under auto dehumidify or fan mode and characters of turbo won t appear TIMER Timer button e On the status of the unit on press this button to set timer off On the status of the unit off press this button to set timer off Press this kev once words Hour on off will appear and flicker In which case press button to adjust time press button continuously to change timing value quickly the setting time range is from 0 5 to 24 hr
12. N an Mounting 4 plate Fig 9 C Install the connection pipe 1 Align the center of the piping flare with the relevant valve 2 Screw in the flare nut by hand and then tighten the nut with spanner and torque wrench refer to the following Indoor unit piping Taper nut Piping Hex nut diameter_ Tightening torque N 2 m p6 15 20 9 52 31 35 N Fi b 12 50 55 b 16 60 65 A 2 Spanner il L ASA ji a Torque wrench NOTE Firstly connect the connection pipe to indoor unit then to outdoor unit pay attention to the piping bending do not damage the connection pipe the joint nut couldn t tighten too much otherwise it may cause leakage 2l Install outdoor unit C Electric wiring 1 Disassemble the handle on the outdoor unit right side plate 2 Take off cord anchorage Connect and fix power connect Handle cord for cooling and heating unit connect and fix power N 2 3 6 connect cord and signal control wire to terminal block blue 7 x l NN yellow 3 Fix the power connection cable with cord anchorage jj eae green l i 4 for cooling and heating unit use the cord anchorage HTE to fix the power connection cable and the signal Mia wird clamp control wire TA powdr conhect wire 4 Ensure wire has been fixed well INDOOR OUTDOOR 5 Install the handle CONNECT FIG NOTE NDOOR e Wrong wi
13. condensate and defrosting waer can Chassis FL Drain be properly discharged connection 22 Check after installation and test operation 4 Check after installation Items to be checked Possible malfunction Has it been fixed firmly The unit may drop shake or emit noise It insufficient cooling heati Have you done the refrigerant leakage test casey ingutficignt cooling heating Is heat insulation sufficient It may cause condensation and dripping Is water drainage well It may cause condensation and dripping Is the voltage in accordance with the rated It may cause electric malfunction voltage marked on the nameplate or damage the part Is the electric wiring and piping It may cause electric malfunction connection installed correctly and securely or damage the part Has the unit been connected to a secure earth connection Is the power cord specified It may cause electrical leakage It may cause electric malfunction or damage the part Is the inlet and outlet been covered It may cause insufficient cooling heating capacity Has the length of connection pipes The refrigerant capacity is not accurate and refrigerant capacity been recorded C Test Operation 1 Before test operation 1 Do not switch on power before installation isfinished completely 2 Electric wiring must be connected correctly and securely 3 Cut off valves of th
14. e connection pipes should be opened 4 All the impurities such as scraps and thrums must be cleared from the unit 2 Test operation method 1 Switch on power press ON OFF button on the wireless remote control to start the operation 2 Press MODE button to select the COOL HEAT Cooling only unit is not available FAN to check whether the operation is normal or not 23 Installation and Maintenance of Healthy Filter C Installation Instructions 1 Forcibly pull the panel for a specific angle from the two ends of the front panel according to the arrow direction Then pull the air filter downwards to remove it See Fig a 2 Mount the healthy filter onto the air filter as shown in Fig b If the air filter cannot be in stalled please mount the healthy filter on the front case as shown in Fig c 3 Mount the air filter properly along the arrow direction in Fig d and then close the panel cover 4 Cleaning and Maintenance Take out the healthy filter before cleaning and reinstall it after cleaning according to the installation instruction Pav special attention to that silver ion filter can t be cleaned with water while active carbon photocatalvst low temperature conversion LTC catalvst formaldehvde eliminator ca techin or mite killing filter can but can t with brush or hard things Dry it in the shade or sun after cleaning but not by wiping C Service Life D The healthy
15. eat in power supply cord N gt op running and pull out of the pug J 5 16 Q Notices for installation C b Important Notices The unit installation work must be done by qualified personnel according to the local rules and this manual Before installation please contact with local authorized maintenance center if unit is not installed bv the authorized maintenance center the malfunction mav not solved due to discommodious contacts When removing the unit to the other place please firstly contact with the authorized Maintenance Center in the local area the appliance must be positioned so that the plug is accessible C Basic Requirements For Installation Position Install in the following place may cause malfunction If it is unavoidable contact with service center please e Place where strong heat sources vapors flammable gas or volatile object are emitted e Place where high frequency waves are generated by radio equipment welders and medical equipment Place where a lot of salinities such as coast exists e Place where the oil machine oil is contained in the air Place where a sulfured gas such as the hot spring zones is generated Other place with special circumstance C Indoor Unit Installation Position Selection D 1 The air inlet and outlet vent should be far from the obstruction make sure that the air can be blown through the whole room 2 Select a posi
16. emitted The sound of fan or compressor relay is switching on or off When the defrosting is started or stop running it will sound That is due to the refrigerant flowed to the reverse direction 15 Troubleshooting Phenomenon Troubleshooting Indoor unit cannot deliver air In HEAT mode when the temperature of indoor heat exchanger is very low that will stop deliver air in order to prevent cool air Within 2min In HEAT mode when the outdoor temperature is low or high humidity there are much frost be formed on the outdoor heat exchanger that the unit will automatically defrost indoor unit stop blowing air for 3 12min During the defrosting there is water flowing out or vapor be produced In dehumidifying mode sometimes indoor fan will stop in order to avoid condensing water be vapo rized again restrain temperature rising Moisture on air outlet vent If unit is running under the high humidity for a long time the moisture will be condensed on the air outlet grill and drip off H1 Defrosting It is normal O Immediately stop all operations and plug out contact the dealer in following situations Pa There is harsh sound during operation The terrible odors emitted during operation Water is leaking in the room Air switch or protection switch often breaks and power plug Ne Carelessy splash water or something into unit There is an abnormal h
17. ere is 1m away from the TV set or stereo sound sets Fig 2 if the wireless remote control can not operate normally please take them out B Sketch map for after 30s later and reinsert if they cannot normally run please change them changing batteries 10 Emergency operation C Displaver indicator light control of indoor unit a It s a special selective button for the users who are not accustomed to the light at sleeping e Get the displayer indicator light on When setting the light function the mark will display on the remote controller screen by pressing this button In which case the diss player indicator light will be on if the AC receives this signal e Get the displayer indicator light off If cancel the light function the mark will disap per on the remote controller screen by pressing this button In which case the displayer indicator light will be off if the AC receives this signal C Emergencv operation If the wireless remote control is lost or broken please use the manual switch button At this time the unit will run at the Auto mode but the temperature and fan speed cannot be changed The operation was shown as below Manual switch To open the panel the manual switch is on the displaver box Turn on the unit At unit turned off press the button the unit will run at Auto mode immediatelv The microcomputer will accord to the indoor temperature to select Coolin
18. etting temp will be decreased bv 1 C 2 hours later setting temp will be decreased by 2 C then it will run at setting temperature X FAN X FAN button e Set X FAN on the characters of X FAN will appearjor off the characters of X FAN disappear bv pressing this kev under cool or dehumidifv mode Once energized the unit will be defaulted to be X FAN off This function can not be set under auto fan or heat mode and the characters of X FAN won t appear Note X FAN is the alternative expression of BLOW for the purpose of understanding LIGHT Light button e Press this button to select LIGHT on or off in the displaver When the LIGHT on is set the icon w will be displayed and the indicator light in the displayer will be on When the LIGHT off is set the icon will be displayed and the indicator light in the displayer will be off TEMP Temp display button e After powered on displaying presetting temperature is defaulted According to customer requirements to display if there are no requirements the presetting temp erature displaying is defaulted there is no signal display on the remote control Press this button display lt i display the presetting temperature display D J display indoor ambient temperature A will not change current display status If current display status is indoor ambient temp when received other remote control sginal then will display pre
19. g Heating Fan and obtain the comfortable effect e Turn off the unit At unit turned on press the button the unit will stop working Iil Clean and care Afessten Turn power off and pull out the power plug before cleaning air conditioner or it mav cause electric shock Never sprinkle water on the indoor unit and the outdoor unit for cleaning because it can cause an electric shock Volatile liquid e g thinner or gasoline will damage the air conditioner So wipe the units with a dry soft cloth or a cloth slightly moistened with water or cleanser C Clean the front panel When cleaning the front panel please dip the cloth into the water temperature of 45 C below then to drv the cloth and wipe the dirtv part Note Please do not to immerse the front panel in water due to there are microcomputer components and circuit diagrams on the front panel C Clean the air filter Recommended once everv three months D NOTE If dust is much more around the air conditioner the air filters should be cleaned many times After taking off the filter don t touch the fin of indoor unit in order to avoid hurt your fingers Take down the air filter At the slot of surface panel to open an angle pull the air filter downward and take it out please see the Fig 4 a b 2 Clean the air filter To clean the dust adhering to the filters you can either use a vacuum Cleaner or wash them with
20. he health problems Don t use the air conditioner for other purposes such as drying clothes preserving foods etc Splashing water on the air conditioner can cause an electric shock and malfunction Don t place a space heater near the air conditioner i Or CO toxicosis may occur for imcomplete burning Notices for use Working principle and special functions for cooling Principle Air conditioner absorbs heat in the room and transmit to outdoor and discharged so that indoor ambient temperature decreased its cooling capacity will increase or decrease by outdoor ambient temperature Anti freezing function If the unit is running in COOL mode and in low temperature there will be frost formed on the heat exchanger when indoor heat exchanger temperature decreased below 0 C the indoor unit microcomputer will stop compressor running and protect the unit Working principle and special functions for heating Principle Air conditioner absorbs heat from outdoor and transmits to indoor in this way to increase room temperature This is the heat pump heating principle its heating capacity will be reduced due to outdoor temperature decrease x If outdoor temperature becomes very low please operate with other heating equipments Defrosting When outdoor temperature is low but high humidity after a long while running frost will form on outdoor unit that will effect the heating effect at this time the au
21. ioner is restarted fe as Waiting ZS TE ou a Once the air conditioner is stopped it will not operate in approximately 3 minutes to protect itself There s unusual smell blowing from the outlet after operation is started a fF gt The unit has no peculiar smell by itself If has that is due to the smell accumulated in the ambient e Solution method Cleaning the filter If problem still has so need to clean air conditioner Please contact with the authorized maintenance center Sound of water flow can be heard during the operation e The air conditioner is started when it is running the compressor started or stopped running or the unit is stopped sometimes there is swoosh or gurgle the sound is due to refrigerant flowing they are not malfuncti ons In COOL mode sometimes the mist emitted from the air outlet vent A e When the indoor temperature and humiditv are very high this phenomenon would happen This is caused bv the room air is swiftly cooled down After running for a while indoor temperature and humiditv will fall down the mist will die awav Creaking noise can be heard when start or stop the unit pe 0 0 _ amp e This is caused by the deformation of plastic due to the changes of temperature 14 Troubleshooting Phenomenon Troubleshooting The unit can not run Breaking o Has
22. nt with the real one according to different D models some models have displayer and some models without displayer the position kand shape of the displaver please refer to the real one Va A This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Do not dispose this product as unsorted municipal waste Collection of such waste separately for special treatment mum is necessary Operation and maintenance notices for operation A K Earth The ground be connected If not please ask the qualified person nel to install Furthermore don t conn ect each wire to the gas pipe water pipe drainage pipe or any other impr oper places hk Be sure to pull out the power plug when not using the air co nditioner for a long time Otherwise the accumulated dust may cause fire or electric shock K Select the most appropriate tem perature er than outside It can preclude the electricity wasted Don t leave windows and doors open for a long time while operating the air conditioner It can decrease the air conditioning capacity Don t block the air intake or outlet vents of bo
23. or unit Air out SET Tewp t BB Cool ik Dry Heat Xy d Run Wireless remote control g Q iU 1 Power cable 2 Remote control 3 Front panel 4 Filter 5 Guide louver 6 Wall pipe ER 7 Bind tape 8 Drainage pipe uu co NI Operation of wireless remote control Names and functions of remote control buttons Note Be sure that there are no obstructions between receiver and remote control Don t drop or throw the remote control Don t let anv liquid in the remote control and put the remote control directiv under the sunlight or anv place where is verv hot Signal a C M TEMPE button e When press button the setting temp will be A increased by 1 C When press button the era mh setting temp will be decreased by 1 c nam k The temp will be changed quickly by pressing Ts the button continuously and setting temp range is 16 30 C gt PE o r e FAN_ FAN speed button Remote control e Press this button once fan speed will change as below oo a ee ee a Low speed uat Middle speed aml High speed Note Under the Drv mode the fan speed isn t adjustable low fan speed is imperative but when operating this button the wireless remote control will send this signal ON OFF ONJOFFbuton ee Swing up and down button
24. repair The height difference of connecting the tubing within 5m the length of connecting the tubing within 10m Select a place where it is out of reach for the children Select a place where will not block the passage and do not influence the city appearance 14 O N DM Bow I7T Notices for installation Safety Requirements For Electric Appliances The power supply should be used the rated voltage and AC exclusive circuit the power cable diameter should be satisfied Don t drag the power cable emphatically It should be reliably earthed and it should be connected to the special earth device the installation work should be operated by the professional The air switch must have the functions of magnetic tripping and heat tripping in order to protect the short circuit and overloading The min distance from the unit and combustive surface is 1 5m The appliance shall be installed in accordance with national wiring regulations An all pole disconnection switch having a contact separation of at least 3mm in all poles should be connected in fixed wiring For models with a power plug make sure the plug is within reach after installation Including an air switch with suitable capacity please note the following table Air switch should be included magnet buckle and heating buckle function it can protect the circuit short and overload Caution please do not use the fuse only for protect the circuit
25. ring may cause spare parts malfunction Ni 2139 e After the cable fixed make sure there should be power a free space between the connection and connect viue connection and fixing place on the lead wire u i Na 21318 OUTDOOR C Air purging and leakage test 1 Connect charging hose of manifold valve to charge end of low pressure valve both high low pressure valves must be tightly shut 2 Connect joint of charging hose to vacuum pump 3 Fully open handle handle of Lo manifold valve 4 Open the vacuum pump to evacuate At the beginning slightly loosen joint nut of low pressure valve to check if there is air coming inside If noise of vacuum pump has been changed the reading of multimeter is 0 Then tighten the nut Liquid pipe ef Gas pipe SD 5 Keep evacuating for more than 15mins and make sure the reading of multi meter is 1 0 x 10 pa 76cmHg 6 Fully open high low pressure valves 7 Remove charging hose from charging end of low pressure valve 8 Tighten bonnet of low pressure valve As shown in Fig 10 C Condensate drainage of outdoor unit no for cooling only The condensate and defrosting water formd during heating in the outdoor unit can be properlv discharged bv drainage pipe Installation method set the drain connection in 25 hole of the chassis has been installed and then connect drainage pipe Od of 2 l with drain nozzle so that
26. se e After tighten the screw slight pull the wire and confirm whether is it firm or not e If the earth wire is wrong connection that may cause electric shock e The cover plate must be fixed and tighten the connection wire if it is poor installed that the dust moisture may enter in or the connection terminal will be affected by outside force and will cause fire or electric shock C Install the indoor unit D External connection electric wire Liquid side piping Gas side pipe e The piping can be lead out from right right rear left left rear 1 When routing the piping and wiring from the left or right side of indoor unit cut off the tailings from the chassis in necessarv Show in Fig 7 1 Cut off the tailings 1 when routing the wiring oniv 2 Cut off the tailings 1 and tailings 2 when routing both the wiring and piping 2 Take out the piping from bodv case wrap the piping electric wire water pipe with tape and pull them through the piping hole As show in Fig 8 3 Hange the mounting slots of the indoor unit on the upper tabs of the rear panel and check if it is firm enough As show in Fig 9 4 The height of the installed location should be 2 5m or more from the floor cao 2 AP Gas side piping Tailing 1 insulation Liquid side j Piping insulation Fig 7 Finally wrap it Ne l with tape Water drainage pipe Ge Right Left rear Na l Right rear Fig 8 Fixing hook T
27. setting temp 5s later return to ambient temp display Other models haven t this function But pressing this button the main unit will click and keep the original status Operation of wireless remote control Guide for operation general operation Press ON OFF button to start the unit after powering the main unit on Note Power the unit on every time the big guide louver and small guide louver will be closed firstly 2 Press MODE button to select desired running mode 3 Press button to set the desired temperature It is unnecessary to set the temperature at AUTO mode Press FAN button to set fan speed the AUTO FAN LOW MID or HIGH could be selected Press SI button to set swing mode HEALTHISAVE End X FAN TEMP TIMER TURBO SLEEP LIGHT C Guide for operation optional operation Press SLEEP button set the sleep mode Press TIMER button then press 4 button to set the cheduled timer on or timer off Press light button to control displaver light on or off Press X FAN button to set X FAN function on or off 5 Press turbo button to set this function on or off E O X FAN TEMP TIMER TURBO SLEEP LIGHT C Introduction for special function K About X FAN function This function indicates that moisture on evaporator of indoor unit will be blowed after the unit is stopped to avoid mould 1
28. t to the Wall pipe outdoor side Insert the piping hole sleeve into the hole to prevent the connection piping and wiring from being damaged when passing through the hole Seal pad Install the water drainage pipe For well draining the drain hose should be placed at a downward slant Wrenched Do not wrench or bend the drain hose or flood its end by water When the long drainage hose passing through indoor should wrap the insulation materials DK Flooded Connect indoor and outdoor electric wires 1 Open the surface panel 2 Remove the wiring cover 3 Route the power connection cord and signal control wire for cooling and heating unit oniv from the back of the indoor unit and pull it toward the front through the wiring hole for connection 4 Connect the interconnection cord to the terminal block and then fix the cord with cord anchorge 5 Reassemble the clampand wiring cover 6 Recover the surface panel Wiring Cover ww 2 3 6 blue ba ro yellow Po green outdoor unit connection 20 Install indoor unit NOTE When connecting the electric wire if the wire length is not enough please contact with the authorized service shop to buv a exclusive electric wire that is long enough and the joint on the wire are not allowed e The electric wiring must be correctiv connected wrong connection mav cause spare parts malfunction Tighten the terminal screw in order to prevent loo
29. th the outdoor and indoor units It can decrease the air conditioning capacity or cause a malfunction Keep combustible spray away from the units more than 1m It can cause afire or explosion Please note whether the installed stand is firm enough or not If it is damaged it may lead to the fall of the unit and cause the injury Don t step on the top of the outdoor unit or place something on it As falling off the outdoor unit can be dangerous jk Don t attempt to repair the air conditioner by yourself The wrong repair will lead to an electric shock or fire so you should contact the service center to repair Notices for operation Jk Ifthe supply cord is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard The airflow direction can be adjusted appro priately At operating adjust the vertical airflow direction by adjusting the louvers of upward do wnward direction And then hold two ends of left and right louver to adjust the horizontal air flow Louver of left right direction Louver of upward downward direction ote Don t insert your hands or stick into the air intake or outlet vents Otherwise it will cause accident jk Don t blow the wind to animals and plants directly It can cause a bad influence to them jk Don t apply the cold wind to the body for a long time It can cause t
30. the power been shut down2 Is power plug loosed Is the circuit protection device tripped off or not Is voltage higher or lower Tested by professionals Is the TIMER correctly used Cooling Heating efficiency is not good C L 00 amp ie Is Temp setting suitable Were inlet and outlet vents obstructed Is filter dirty Are the windows and doors clothed Did Fan speed set at low speed Is there any heat sources in the room Wireless remote control is not available S L 8 The unit is interfered bv abnormal or frequent functions switchover occasionallv the controller cannot operate At this time vou need to pull out of the plug and reinsert it Is it in its receiving range Or obstructed To check the voltage in wireless remote control inside is charged otherwise to replace the batteries Whether the wireless remote control is damaged If water leakage in the room The air humidity is on the high side Condensing water over flowed The connection position of indoor unit drainage pipe is loosed If water leakage in outdoor unit When the unit is running in COOL mode the pipe and connection of pipe would be condensed due to the water cooled down When the unit is running in Auto Defrosting mode the ice thawed and flowed out When the unit is running in HEAT mode the water adhered on heat exchanger dripped off Noise from indoor unit
31. tion where the condensing water can be easily drained out and the place is easily connected for outdoor unit Select a location where the children can not reach Can select the place where is strong enough to withstand the full weight and vibration of the unit And will not increase the noise Be sure to leave enough space to allow access for routine maintenance The height of the installed location should be 250cm or more from the floor Select a place about 1m or more away from TVset or any other electric appliances Select a place where the filter can be easily taken out Make sure that the indoor unit installation should accord with installation dimension diagram requirements Do not use the unit in the immediate surroundings of a laundry a bath a shower or a swimming pool Outdoor Unit Installation Position Selection Select a location from which noise and outflow air emitted by unit will not inconvenience neighbors animals plants Select a location where there should be sufficient ventilation Select a location where there should be no obstructions cover the inlet and outlet vent The location should be able to withstand the full weight and vibration of the outdoor unit and permit safe installation Select a dry place but do not expose under the direct sunlight or strong wind Make sure that the outdoor unit installation dimension should accord with installation dimension diagram convenient for maintenance
32. to defrosting function will act the heat running will stop for 8 10mins During the auto defrosting the fan motors of indoor unit and outdoor unit will stop During the defrosting the indoor indicator flashes the outdoor unit may emit vapor This is due to the defrosting it isn t malfunction After defrosting finished the heating will recover automatically Anti cool wind function In Heat mode under the following three kinds of state if indoor heat exchanger doesn t arrive at certain temp indoor fan will not act in order to prevent cool wind blowing within 2 mins 1 Heating starts 2 After Auto Defrost finished 3 Heating under the low temperature Gentle Breeze In the following situation the indoor unit may blow gentle breeze and the guide louver rotate to a certain position 1 In Heat mode the unit turned on the compressor doesn t arrive the starting condition 2 In Heat mode the temperature arrive at the setting value and the compressor stop running about 1min Notices for use X Working temperature range Indoor sideDB WB C Outdoor sideDB WB C Maximum cooling 32 23 48 Minimum cooling 21 15 10 Maximum heating 27 24 18 Minimum heating 20 15 The operating temperature range outdoor temperature for cooling unit is 21 C 43 C for cooling and heating unit is 5 C 43 C Names and functions of each part Indo