Olympic Operating & Mounting Manual
Contents
1. Phase Blue Neutral via a power socket Product with plug diagram A or connexion box Mechanical thermostat diagram B by a 3 wire cable Brown Phase Blue Neutral Black Pilot wire by means of a connexion box version with pilote wire diagram C In humid areas such as bathrooms and kitchens the power socket must be installed at least 25 cm above the floor The installation must be equipped with a omnipole disconnexion mechanism with a break contact distance of at least 3mm Earthing is prohibited Do not connect the pilot wire black to earth The heater must be installed by a qualified electrician in accordance with the local regulations The heater and the pilot wire black must NOT be connected to earth If the heater wire is damaged it must be replaced by a qualified person to avoid hazard If a pilot or piloted panel heater is protected by 30mA differential e g bathroom the pilot wire s power must be protected on this differential Panel heater cable Fy Neutral Electricity grid Pilot wire black Oscilloscope R f Neutral Mode POWER CUT anned COMFORT ANTI FREEZE STOP 2 4 Lock the appliance on the hook on bracket 2 possible cases Complete N gative Positive ee Commands No current altermation Half altermation Half altermation Phase brown oe 230 V 115V 115 V Berre 1st case only one heater SA The pilot wire free end is insulated and not further conne
2. C15 F117P Convecteur Notice d installation et d utilisation Guide conserver par l utilisateur Convector Documentation for installation and use The user must conserve this guideRUS KOHBEKTOP bl Radiator Standard modell Volume 3 NE PAS COUVRIR i B i L Fil MARRON Phase IE E The product you have just purchased has undergone numerous tests and inspections to guarantee the highest quality We hope it will give you entire satisfaction INSTALLATION OF THE PANEL HEATER Please read the instructions before starting to install the heater Disconnect the power before carrying out any work on the heater Keep these instructions even once you have installed your heater 1 Where to install your heater This equipment was designed to be installed in a residence Please ask your distributor before using it for any other purpose The panel heater should be installed according to normal trade practice and in compliance with legislation in the relevant country the IEE Wiring Regulat
3. ND ADRESS This information is shown on the plate which can be seen on the left side or behind the front grille of the unit FOR SALES IN AUSTRALIA ATLANTIC AUSTRALASIA PTY LTD INSTALLER S STAMP 4 13 25 Church Street Hawthom Victoria 3122 Australia Free call 1800 677 857 Phone 03 9852 9599 Fax 03 9852 9844 web www atlantics com au
4. arte is properly inserted in its housing and that it is operating normally batteries The unit is permanently heating Make sure that it is not in a draft and that the temperature setting has not been changed This unit with electronic control is equipped with a microprocessor that can be distribued by some severe mains voltage dis turbances outside EC standards defining the disturbance protection level If there are any problems thermostat blocked etc switch off the unit power supply fuse circuit breaker etc for about 5 minutes to allow the unit to start again Have your energy distributor check your power supply if the phenomenon occurs frequently WARRANTY CONDITIONS KEEP THIS DOCUMENT IN A SAFE PLACE This certificate should only be produced if you are making a complaint attached with the invoice of the purchase This guarantee is applicable for 2 years from the date of original purchase and shall be valid for no more than 30 months from the date of manufacture Your Atlantic distributor will exchange parts shown to be defective in manufacture The replacement parts will be of charge but Atlantic does not accept responsability for freight or labor charges or losses in transit This guaranteeexcludes damage by neglect shipping or accident and any damage due to incorrect installation use or purposes other than those intended or failure to observe the instructions given UNIT TYPE SERIAL NUMBER CUSTOMER S NAME A
5. cted 2nd case multiple heaters A The pilot wire of all heaters in a control group up to a maximum of 20 units with any one them used as the Master are connected by a 1 0mm2 220 240V insulated cable USING THE PANEL HEATER 1 Description of the control unit 7 and 8 gt TEN I switch stop 0 gt Temperature adjustment control knob V1 gt Heating indicator light 2 Fixing the comfort temperature 3 The comfort temperature is the temperature that you would like while the room is occupied Put the switch to 3 marchell b Mechanical set the control knob to between 4 and 5 Electronical set the control knob on 5 the heating indicator V1 comes on if the room temperature is below the required temperature c Wait a few hours for the temperature to stabilise d If the setting is satisfactory if necessary use a thermometer to check mark the position for future use e If the setting is not satisfactory adjust it and start again from point c 3 Fixing the Eco temperature electronic model This is the required temperature during periods when the room is unoccupied It is recommended that this mode should be used if the room is unoccupied for more than 2 hours a Set the cursor switch knob to b Adjust the control knob between 3 and 4 the heating light V1 comes on if the ambient temperature is lower than the instruction of desired Eco temperature c Wait a few hours until the tem
6. e pilote wire to a programming control or a product equiped with pass program system in order to use these different modes You can control several convectors with a single programmer or a pro duct equiped with pass program system Warning The control unit will consider frost free and off signals in any switch selection RECOMMENDATIONS FOR USE There is no point in setting maximum heating the room temperature will not rise any quicker When you air the room disconnect the panel heater by putting the switch to STOP 0 If you leave for several hours remember to reduce the temperature Absence for less than 2 hours do not touch the controls 2 to 24 hours lower the control knob by two graduations more than 24 hours or in the summer put the control knob to T mecanical put the switch on electronic If you have several units in a room let them operate simultaneously This will give you a more uniform temperature without increasing electricity consumption This device is not intended for use by persons including children with physical sensory or mental disability or by persons lacking experience or knowledge unless they have received from a person in charge of their safety adequate supervision or preliminary instructions on how to use the device Care must be taken at all times to keep children from playing with the device Do not introduce objects or paper into the device Do not totally or partially block the g
7. ions The equipment is class 2 E and is protected against splashed water Therefore it can be installed in volume 2 provided the panel heater s controls cannot be reached by a person using the shower or bath Comply with the minimum clearance distances for positioning of the panel heater If your wall covering is laid on foam a spacer the same thickness as the foam must be placed under the panel heater s sup port This ensures there is free space behind the panel heater to make sure its control settings are not adversely affected Do not install the panel heater gt draught likely to affect the control settings under a fan etc amp Under a fixed mains power socket Except in the UK Please refer to the IEE Regulations 601 06 01 and 601 08 01 BS7671 It is forbiden to install vertical product horizontal position 2 How to install the panel heater 2 1 Release the appliance s hook on bracket We recommend that you place the radiant panel flat face down Have a straight head screwdriver to hand 2 2 Fix the hook on bracket Drilling points A Drilling points B Note Do not use the device in mobile or feets or on casters diagram 5 except the range feet ref 418010 418015 418020 419010 419015 419020 2 3 Connecting the panel heater The panel heater must be powered with 220 240V 50Hz The panel heater must be connected to the mains either by a 2 wire cable Brown
8. perature stabilizes d If the setting is satisfactory if necessary use a thermometer to check mark the position If the setting is not satisfactory adjust it and start again from point c 4 Frost Free mode T This mode is used to keep the temperature at approximately 7 C in the room when you are absent from the house for a prolonged period i e more than 24 hours a Leave the switch on I set the control knob to T mecanical model b Set the switch on T electronic model 5 The heating indicator V1 electronic model This light comes on when the heating element is working It may flash when the temperature has stabilised 6 Locking the controls 9 and 0 It is possible to lock or limit use of the control knob and lock the switch to prevent unauthorised manipulation of the panel heater children etc a Unhook the panel heater from its wall mounting b Remove the slugs P on the back of the thermostat from their mountings Select position to lock the control knob or position L to limit the amount it can be turned Position blocks the switch for Electronic Model 7 Using the pilote wire The product with pilote wire can receive the following signals from a master unit comfort temperature of 2 control knob eco comfort temperature 3 C to 4 C frost free approximately 7 C off Put the switch 1 to the programming mode clock symbol The product must be connected through th
9. rilles on the front or inside of the appliance as this may cause overheating If the supply cord is damaged it must be replaced by a service agent or similarly qualified person in order to avoid a hazard applies to all units All work to the inside of the appliance must be carried out by a licensed electrician MAINTENANCE To maintain performances of your unit you should clean the upper and lower grilles of the unit about twice a year using avacuum cleaner or a brush Have a professional check the inside of the unit every five years Dirt may collect on the grille of the unit if the atmosphere is polluted This phenomenon is due to the poor quality of the ambient air In this case it is recommended to check that the room is well ventilated ventilation air inlet etc and that the air is clean The unit will not be replaced under the guarantee because of this type of dirt The unit casing should be cleaned with a damp cloth never use abrasive products TROUBLE SHOOTING If the unit does not heat Check that the programmer is in COMFORT mode electronical Make sure that the installation circuit breakers are switched on or that the load shedder if you have one has not switched off the unit power supply Check the air temperature in the room The unit does not carry out programming orders version with pilot wire Make sure that the programming unit is being correctly used refer to its user s manual or that the Chronoc