1. User Manual TN450 Tissue Flotation Bath P47673 scientific T e AN N E R Read Priorto Operation Always keep this manual near the unit TANNER User Manual scientific TN450 Tissue Flotation Bath 888 708 5233 Info TannerScientific com www TannerScientific com Contents 1 General Summary Page 2 2 Installation 2 3 SORRY ne 3 4 Technical Parameters 3 5 Equipment Overview 4 6 Operation 5 7 Cleaning amp Maintenance 6 8 Troubleshooting 6 9 Warranty Service 7 Tanner Scientific TN450 Tissue Flotation Bath 1 1 General Summary The TN450 Tissue Flotation Bath is used for heating a tissue ribbon before placing iton a slide for reading Its small size and light weight make ita practical instrument for pathology labs hospitals medical schools and scientific research institutions Features e Digital screen with indicator lights e Controller microprocessor e Four bright LED lights located around the glass bowl e Advanced heating components superior thermal conduction performance homogeneous heating energy savings and reliable quality e Integrated heating block ensures immediate uniform and controlled heating e Real time display of all settings e Memory function and recovery function 2 Installation e The instrument should be installed with a grounding socket e Athree line grounded power source is required Safe Handling e When transpo
2. 11 Key Press to decrease the setting temperature 6 Operation Starting up the Machine e Use the power cord supplied with the instrument The cord must be connected with a grounding socket e Before you connectthe main electrical source please ensure that the power switch is in the O OFF position e Insert one end into the instrument s power plug first and then insert the other end into the power plug in the lab s electrical socket Using the Waterbath 1 Fill the glass dish the appropriate amount of water 2 Properly place the dish into the flotation bath 3 Place the magnetic probe into the bath 4 Turn on the heaters by pressing the BATH button on the key pad 5 Allow waterbath to reach presettemperature before use 6 After use ensure heaters are turned off using the BATH button on the key pad 7 Empty water from the dish clean with mild soap and water then dry Tanner Scientific TN450 Tissue Flotation Bath 5 7 Cleaning amp Maintenance Cleaning e Before you clean the equipment turn off the power switch and pull out the power socket e Only home use cleaning substances may be used for cleaning the instrument Acetone and benzene will damage the paint on the surface of the instrument e Use damp cloth to clean the equipment e Equipment should be cleaned daily Maintenance e Changing the Fuse Keep the model and the specifications ofthe new fuse the same Refer to
3. the Technical Parameters 8 Troubleshooting PROBLEMS CAUSES ELIMINATION Power line is not connected Connect power line turn on again Switch isn t turned on Press the switch and ensure that No response when trying to turn on eis GO Fuse is not connected well the indicator light is on or may be burned out Check fuse replace if necessary TRAY HEAT indicator Magnetic On Off switch Adjust the position of is off when working may be dislocated Magnetic On Off switch Heater is damaged Temperature sensor TRAY HEAT indicator is on is NOT functioning but does NOT heat Contact technical support at 888 708 5233 Temperature sensor may be damaged 6 Tanner Scientific TN450 Tissue Flotation Bath 9 Warranty amp Service Tanner Scientific warrantees this product for a period of one year from the date of purchase provided that the customer complies with the rules ofthis manual Extended warranties are available Contact Tanner Scientific at 888 708 5233 for more information Tanner Scientific will not be responsible for the damage and other problems caused by abuse and misuse of the instrument Service Information If you require any service or parts during the warranty period please contact Tanner Scientific at 888 708 5233 or the sales agent who sold you the unit Priorto calling please have the instrument model and seria
4. cumented consent by Tanner Scientific Statements drawings illustrations and other information regarding contents or technical details of the present user manual are not to be considered as warranted characteristics of our products These are determined only by the contract provisions agreed between us and our customers Refer to the name plate on the back of the unit for the serial number and manufacturing date of this instrument Distributed by Tanner Scientific 1073 Tallevast Rd Sarasota Florida 34243 888 708 5233 Info TannerScientific com www TannerScientific com TANNER scientific 1073 Tallevast Rd Sarasota Florida 34243 888 708 5233 Info TannerScientific com www TannerScientific com
5. l number ready Amendment Tanner Scientific reserves the rightto change the technical parameters of any model for improving the function of our instruments Quality Guarantee e Tanner Scientific will ensure that every instrument sold has been strictly examined to ensure it meets our stringent quality and technical standards e Service terms are only provided for those who regularly use the instrument and operate the instrument according to its instructions Disposal of Unwanted Instruments Discarding the instrument and its parts should be done according to current laws and regulations Tanner Scientific TN450 Tissue Flotation Bath 7 TANNER scientific Information The information notes and figures that appear in this user manual represent the present state of knowledge as we comprehend it Due to continuous improvements in technology and manufacturing technique specific and manufacturing procedures may change For inaccurate statements drawings and technical illustrations in this user manual we exclude liability as far as permissible No liability is accepted for any monetary loss or consequential damage caused by or related to compliance with statements or other information in this user manual Tanner Scientific will update the manual as needed according to the latest technological developments This document is protected under copyright laws Any reproduction of illustrations or text requires prompt do
6. nner Scientific TN450 Tissue Flotation Bath 3 5 Equipment Overview KEYPAD aj HOUSING MAGNETIC ON OFF SWITCH GLASS BATH TEMP CLOCK SET TEMP C uns 7 EE Tissue Flotation Bath 1 Bath On Off Key 6 Actual Temperature Current Time Screen 2 Light On Off Key 7 Hours 3 Heating Indicator 8 Minutes 4 Actual Temperature Key 9 Set Temperature Screen 5 Current Time Key 10 Set Temperature Increase 11 Set Temperature Decrease 4 Tanner Scientific TN450 Tissue Flotation Bath 1 BATH Press this key and the TRAY HEAT indicator will illuminate The unit will then begin to heat Press button again to turn the TRAY HEAT indicator off The unit will then stop heating When the magnetic on off switch is removed from the water the TRAY HEAT indicator should go off and the unit should stop heating The TRAY HEAT indicator will be off if the actual temperature reaches the setting temperature 2 LIGHT Press to turn on the four LED lights 3 TRAY HEAT Light If the machine is heating this light remains on Otherwise it is off 4 TEMP Press to check the actual temperature 5 CLOCK Press to check current time 6 TEMP CLOCK Screen Displays the actual temperature and current time 7 HRS Press to set hours from 0 to 24 8 MIN Press to set minutes from 0 to 59 9 SET TEMP Screen Displays the setting temperature 10 Key Press to increase the setting temperature
7. rting the package handle with care avoid getting wet and keep in upright position e If the outer package is damaged seriously do NOT open and immediately contact Tanner Scientific at 888 708 5233 and the transportation carrier e Unpack the carton and remove all components e Place uniton a stable platform within the lab e DO NOT PUT THE INSTRUMENT NEAR ANY EXPLOSIVE OR FLAMMABLE MATERIALS e Water bath should be stored in a clean and ventilated room in which humidity is less than 8096 2 Tanner Scientific TN450 Tissue Flotation Bath 3 Safety e Keep equipment clear of any flammable chemicals and avoid high heat areas e Avoid prolonged contact with the LCD screen as it can crack and not function correctly e When the instrument is on do NOT touch any heated area with your hand e Turn off the main switch and pull outthe power socket before changing a fuse e Never place an empty dry glass bowl in the bath when the heaters are on The bowl will become very hot and could cause burns when touched e If equipment remains unused for a long time pull out the power socket and install the dust cover to extend the life of the instrument 4 Technical Parameters Temperature Setting Range 0 55 C Temperature Tolerance 1 C Working Voltage AC110V 60Hz Power 400 VA Fuse F6A L 250AC Dimensions for Glass Bowl 13 8 x 8 7 x 1 8 Overall Dimensions 16 2 x 20 1 x 5 9 Weight 21lbs Ta

Download Pdf Manuals

image

Related Search

Related Contents

Easypix GoXtreme Nano  電子マニュアル標準マーク 使い方ガイドライン  Kit 59501 - Air Lift  Philips AZ9040/05 User's Manual  Samsung GE107L-S User Manual  Integración de Moodle® Direct (versión 2) de Turnitin Manual de  Title: Electroservices (Midlands) Ltd. – Client  Mode d`emploi téléchargement ebooks  BASSINETTE CONVERTIBLE TAMMY TAMMY CONVERTIBLE CRIB  Handbuch MST 30-40  