Home
Simon XT Quick Operation Guide
Contents
1. em such as old alarm history by pressing Disarm after checking the status Touchpads and key fobs You can use touchpads and key fobs to control the security system from remote locations in and near your home Interfacing with the system using a touchpad is similar to using the panel Refer to the Simon XT User Manual and the touchpad or key fob documentation for details Status beeps The panel sounds status beeps to alert you to various system events and conditions as shown in Table 3 below Table 3 Status beeps Activity Beep response Doors Windows Exit delay and entry delay beeps sound two times every 5 seconds and two times per second during the last 10 seconds Motions Exit delay and entry delay beeps sound three times every 5 seconds and three times per second during the last 10 seconds Doors Windows Exit delay and entry delay beeps sound four times and Motions every 5 seconds and four times per second during the last 10 seconds Disarm One beep Chime Two beeps Special chime Three beeps Property asset management One beep Information displays only on the Two Way Talking Touch Screen Trouble beeps Six beeps every minute Press Status to stop beeps for 4 hours No activity beeps Twenty beeps every minute for 5 minutes feature must be programmed by the installer P N 466 2399 REV C ISS 9JAN13 Alarm sirens Exterior and interior sirens make three different alarm sou
2. interlogix A UTC Fire amp Security Company Simon XT Quick Operation Guide This is the Quick Operation Guide for Simon XT models 600 1054 95R 11 and 600 1054 95R 11 CN Operation Use this document to quickly begin operating your Simon XT security system Refer to your Simon XT User Manual for full operating details and programming options Note The default master code is 1 2 3 4 when the security system is shipped from the factory You should change your code after your system is installed To operate the security system e Use the front panel buttons to arm disarm the system when you enter or exit your home and to determine which sensors are active and the system status e Use the three fast action keys to communicate with the central monitoring station to report police fire or emergency alarms e Use a combination of the panel buttons and the display menu to program certain user features This method is used by your installer to establish your system configuration Refer to your Simon XT User Manual Table 1 below describes the panel keys and features Table 1 Panel keys and features Control Description Piezo siren Provides alarm beeps and status beeps LCD display Provides a 2 x 16 character array that displays a variety of phrases and icons Doors Windows Press to arm perimeter sensors Motions Press to arm interior sensors Disarm Press to turn off intrusion burglary protection for your sys
3. le condition is corrected To stop the trouble beeps press Status or arm and then disarm the system while the trouble condition exists Trouble beeps will resume 4 hours later unless the trouble condition is corrected Refer to your Simon XT User Manual for details P N 466 2399 REV C ISS 9JAN13 Programming Your Simon XT security system allows you to program certain user options such as access codes time schedules or the system time Refer to your Simon XT User Manual for programming options and details Chimes Use the chime feature to signal when a protected door is opened while the system is disarmed The panel chimes twice when a chime sensor is tripped if the chime mode is enabled This feature allows you to be notified when family members are going in and out of your home The chime and special chime features are turned on or off in the System menu Note If there are no chime sensors in your system the chime option will not appear in the System menu Your installer may have programmed the system to speak the sensor name or make a custom chime sound when a chime sensor is tripped The chime sound if programmed will be played in place of the standard chime beeps To enable or disable the chime feature 1 Scroll until the display shows Chime and then press OK The current setting will flash 2 Scroll to toggle the chime feature on or off and then press OK The setting will stop flashing 3 Press Status to e
4. nds on the premises each indicating a different type of alarm Sirens are programmed by the installer to time out and stop sounding after a specified time Table 4 below describes the siren sounds used by the security system Table 4 Siren sounds Function Fire Intrusion Emergency Interior and Temporal 3 Steady Fast on off panel siren Exterior siren Temporal 3 Steady Note Temporal 3 refers to a continuous pattern of three siren pulses then off for 1 5 seconds three siren pulses then off for 1 5 seconds Panel indicator lights Table 5 below describes the indicator lights on the front panel Table 5 Indicator light Button When button light is on When button flashes Doors and windows armed and no entry delay on Doors and windows armed Doors Windows Motions Motions armed Motion sensors armed and latchkey on Disarm System disarmed System subdisarmed Status System trouble open System in alarm sensor or bypassed sensor OK There are no open sensors Chime solid bell Special chime outlined bell Latchkey on key Latchkey feature on Door will cause chime Motion will cause chime Trouble beeps Your security system is able to automatically test itself for e Power failures e Low batteries e Nonworking sensors e Communication trouble with the central monitoring station When your system detects one of the problems above six rapid beeps sound every minute until the troub
5. s and motion sensors level 4 1 Press Doors Windows 2 Enter your code when the display shows Enter Code if a code is required 3 While the panel is in the process of arming press Motions The display shows Doors Windows amp Motions speaks Doors and Windows On Motions On and the Doors Windows and Motions buttons light up The panel starts an exit delay and sounds exit beeps in groups of four until the exit delay expires Silent exit Press Silent after you arm the system to silence status beeps The silent exit feature silences the status beeps that accompany the exit delay The panel will still beep at the beginning and end of the exit delay Note Enabling silent exit doubles the exit delay time Alarms The system provides a series of alarms that indicate an unusual occurrence When an alarm is active the display shows Alarm Alarm Alarm Press Status 2 4 To cancel the alarm enter a valid master or user code After alarms are canceled the system will be disarmed System status Press Status no code is required to cause the system to display and speak the following types of information e Alarm conditions e Alarm history e Trouble conditions e Open sensors e Bypassed sensors The Status button blinks when an active alarm exists The Status button is lit when an abnormal condition such as a trouble or open sensor exists in the system You can clear certain status entries from the syst
6. such as smoke or carbon monoxide detectors stay active at all times 1 Disarm In this level only 24 hour sensors are active 2 Arm door and This level arms the door and window window sensors sensors while leaving the interior motion exterior sensors disarmed 3 Arm motion sensors This level arms the interior motion interior sensors while leaving the exterior door and window sensors disarmed 4 Arm doors windows This level arms all sensors and motion sensors P N 466 2399 REV C ISS 9JAN13 To disarm level 1 1 Press Disarm 2 Enter your code when the displays shows Enter Code The panel displays and speaks Disarmed the Disarm button lights up and the panel beeps once To arm doors and windows level 2 1 Ensure that all doors and windows are closed 2 Press Doors Windows 3 Enter your code when the displays shows Enter Code if a code is required The panel displays Doors Windows speaks Doors and Windows On and the Doors Windows button lights up The panel starts an exit delay and sounds exit beeps in groups of two until the exit delay expires To arm motion sensors level 3 1 Press Motions 2 Enter your code when the display shows Enter Code if a code is required The display shows Motions speaks Motions On and the Motions button lights The panel starts an exit delay and sounds exit beeps in groups of three until the exit delay expires To arm doors window
7. tem Only intrusion burglary sensors are disarmed Environmental sensors such as smoke and carbon monoxide detectors stay active at all times Status Press to determine system status Silent Press to silence exit beeps when arming Bypass Press to bypass a sensor Emergency cross Press and hold for 2 seconds or press twice quickly to call the central monitoring station and Fire fl ite tame notify them of a nonmedical call for help Police shield Microphone Use to communicate with the central monitoring station after an alarm Control Description Scroll up scroll down Press to scroll through lists of similar items arrows OK Press to select a particular menu item or commit to panel memory a menu item that has just been programmed Numeric keypad Press the keys 0 to 9 and to enter access codes or other numerical data Press to turn lights on Press to turn lights off Speaker Provides voice output and sound key beeps While the panel is idle the text displays Display line 1 Arming level Display line 2 HH MMx Time and status icons Arming and disarming Table 2 below describes the arming levels that you can set from the control panel Table 2 Arming levels Level Function Description 0 Subdisarm If your system includes 24 hour protection sensors you must subdisarm the panel before accessing these areas to avoid causing an alarm Environmental sensors
8. xit A solid bell icon will appear in the display when the chime feature is enabled Special chime The special chime feature allows you to install motion sensors in a patio or at the front door and be notified when someone is approaching those areas These motion sensors are not used for intrusion protection The panel will chime three times if the special chime mode is enabled Note If there are no special chime sensors in your system the special chime option will not appear in the System menu To enable or disable the special chime feature 1 Scroll until the display shows Special Chime and then press OK The current setting will flash 2 Scroll to toggle the special chime feature on or off and then press OK The setting will stop flashing 3 Press Status to exit An outlined bell icon will appear in the display when the special chime feature is enabled Note This menu option will not appear if special chime sensors are not in your system 3 4 Contact information For contact information see www interlogix com www utcfireandsecurity com 2013 UTC Fire amp Security Americas Corporation Inc Interlogix is part of UTC Climate Controls amp Security a unit of United Technologies Corporation All rights reserved 4 4 P N 466 2399 REV C ISS 9JAN13