WS-BATTERY Battery Pack User`s Manual
Contents
1. If an indication stated in above Tables 3 and 4 is shown the BATTERY PACK or BATTERY CHARGER may be faulty If this occurs immediately contact the sales office or service center of LeCroy Corporation 40 Accessory E Specifications a Product Specifications 1 of 2 lt Electrical specifications gt Rated capacity 8 4 Ah or more Nominal voltage 22 2 Vde Maximum charging voltage 25 2 Vdc Discharging end voltage 18 0 Vdc Charging discharging cycle 6 3 Ah or more 75 Charging temperature Charging time at a temperature listed below characteristics with charging current of 5 0A 5 C Approx 5 0 h 20 C Approx 3 0 h 40 C Approx 3 0 h Discharging temperature Discharging capacity at a temperature listed characteristics below with discharging current of 1 8A 5 C 7 7 Ah 92 5 20 C 8 4 Ah 100 40 C 8 0 Ah 95 Specifications are subject to change without prior notice 2 Discharging capacity when charging and discharging under conditions below Charging Charging with constant current and voltage 7 5 A 25 2 V at an atmospheric temperature of 20 C 2 C Discharging Discharging to discharging end voltage 18 0 V with constant current 1 8 A at an atmospheric temperature of 20 C 2 C 3 Average operating voltage when charging and discharging under conditions stated in 2 4 Discharging capacity after re charging after charg
2. Sending Back for Repairs If the instrument is inoperable send it back to LeCroy Corporation Refer to the contact address given at the end of this manual We will repair it without charge as long as it is under warranty When sending back the instrument explicitly describe the following product name serial number description of the trouble and name post phone number of the contact person Table of Contents E Safety Requirements iie eas we Reese et 3 m Product Disposal and RECYCIING eee eeeeseeeeeeneeeeeeeneeereenneeerenaeees 8 m Handling the BATTERY PACK cecceeceeeeeeeeeeeeseeeeeeeeeeneeeneeens 9 a Overview of BATTERY PACK ccceeseceeeeeseeeeeeneeeessneeeess 9 b When the BATTERY PACK is delivered ccceccceeeeereeeees 9 c Storing the BATTERY PACK 2 ccecceeceeeeeeeeeeeeeeeeeeeeseeeeeees 10 d Unpacking and packing the BATTERY PACK c eeseee 11 e Transporting the BATTERY PACK cc cccesesceeeeeeteeeeeseeeees 12 f Longevity of the BATTERY PACK cccesseeeseeeeeeeeeseeeeeeeeeaes 12 g Disposing of the BATTERY PACK cesecceesceeeeeeeneeeeeeeeeaes 12 BM OVGIVICW 3 esi cccecettn deter aaea aae ia ea Adele dice 13 E Configuration i e eiieeii renee ii iedereeen 13 nits ant ete a a aa aa a aara aaa aaar a a a a a eS 15 a BATTERY PACK sidia a ete 15 b DG OUT Cable i ccencn tein ceed liiaeidlediedeeinieee 16 E When
3. XStream gt Services gt Start Battery Management See Figure 5 LeCroyUser Internet My Documents amp Internet Explorer w E mail 4 My Recent Documents gt I Outlook Express 2 My Pictures 2p My music ve Favorites Et Accessories ft REALTEK Gigabit and Fast Ethe eh startup internet Explorer J Outlook Express All Programs Windows Media Player Figure 5 Starting up from Start Menu 19 BATTERY PACK User s Manual 8 Battery Management Wizard is then started up Any of the dialog boxes shown in Figures 6a to 6c may appear e When the dialog box shown in Figure 6a appears click Next and go to step 9 e When the dialog box shown in Figure 6b appears the battery management function is already set enabled When connecting the BATTERY PACK to the oscilloscope for the first time click Restart Battery Management Function and go to step 9 e When the dialog box shown in Figure 6c appears the BATTERY PACK cannot be used in this status since the oscilloscope does not have any hardware for the battery management Click Cancel For details about hardware for the battery management of the oscilloscope contact the sales person or service department of LeCroy Corporation Battery Management Wizard WS BATTERY The battery management function of the oscilloscope is made enabled To make this Function enabled the optional WS BATTERY is absolutely require
4. Negligence of the above instruction is hazardous and may cause an electric shock a fire or a malfunction Do not touch any leaking fluid from the BATTERY PACK If leaking fluid enters your eye s do not rub your eye s immediately wash your eye s completely by flowing clean water and consult a doctor If leaking fluid is sticking to your skin or clothing immediately wash such part completely by flowing clean water If the discharging time of this product becomes extremely short the service life of the BATTERY PACK is expired 5 BATTERY PACK User s Manual If this occurs purchase a new BATTERY PACK To do so contact relevant sales person or sales office of LeCroy Corporation If this product is not used complete the operation of the oscilloscope and turn OFF the POWER switch of this product Failure to do so may cause the oscilloscope to be faulty or the data to be corrupted If the POWER switch is kept turned ON electric power is consumed continuously to supply the electric power to the standby circuit of the oscilloscope Eventually the output voltage becomes lower than the discharging end voltage of the rechargeable and the discharge protection function is activated to shut down the output Do not float the WaveSufer oscilloscope when it is powered by the Battery Pack Use the safety ground cable to connect oscilloscope to earth ground When operating the WaveSurfer oscilloscope from AC line power with the s
5. PACK store the BATTERY PACK in an atmospheric environment where the temperature a range of 5 C to 20 C is recommended and humidity are as low as possible dust is minimized and corrosive gas does not exist The methods for short term and long term storage of the BATTERY PACK are as follows Short term storage Please keep the BATTERY PACK in less than 80 relative humidity and within the range of 20 C to 45 C There is a possibility that metallic parts may corrode and that a leak may be generated if the BATTERY PACK is kept at the environment with high humidity or beyond the limits of the above mentioned temperature Long term storage Please keep the BATTERY PACK within the range of 10 C to 25 C and in less than 80 relative humidity when keeping the BATTERY PACK for a long term The BATTERY PACK should receive a full charge at least once every six months when keeping it for a long term 10 Accessory d Unpacking and packing the BATTERY PACK When the BATTERY PACK is delivered unpack it as described in Figure 1 When packing the BATTERY PACK for some reason such as repair use the original carton boxes bags and cushion materials which have been received at delivery to repack it BATTERY PACK Air cap bag Cushion material A Cushion material A Cushion material B ele ion material B Carton box Figure 1
6. lithium ion battery need to be recycled or disposed of according to the local laws and regulations When disposing of such battery packs ask an appropriate recycling company about local laws and regulations 12 Accessory E Overview This product is an accessory specially designed for the Wavesurfer 400 series oscilloscope and intended to supply DC power to the oscilloscope Normally the oscilloscope is operated with the power cord connected to a commercial AC power supply However the oscilloscope can also be operated by the power supplied from this product This instruction manual describes how to mount this product on the oscilloscope how to connect the product to the charger and oscilloscope and how to perform the operation Before using this product thoroughly read this instruction manual to fully understand its contents E Configuration This product hereafter referred to as BATTERY PACK is used with it mounted on the rear of the oscilloscope as shown in Figure 2 below The DC voltage is output to the BATTERY IN 1 or BATTERY IN 2 connector through the DC OUT cable In Figure 2 the DC OUT cable is connected to the DC OUT indicated on the label connector of the BATTERY PACK The CHARGE CONTROL cable of the charger is connected to the CHARGE CONTROL indicated on the label connector of the BATTERY PACK only when charging the BATTERY PACK NOTE 1 When the AC power cord is connected to the rear of the oscil
7. C Use outside this range causes damage Operation time of oscilloscope Reference value When using the fully charged BATTERY PACK at 20 C with the factory shipment panel settings of the oscilloscope the reference operation time of the oscilloscope is shown below e Oscilloscope model 454 434 424 Approximately 100 min Oscilloscope model 452 432 422 Approximately 140 min Note that the above operation time may vary depending on the operating conditions setup and temperature 42 Accessory c Certifications EC Declaration of Conformity Meets intent of the European Council Directives 73 23 EEC for product safety and 89 336 EEC for electromagnetic compatibility This declaration is based upon compliance of the WS BATTERY to the following standards EN 61326 1997 A3 2003 EMC requirements for electrical equipment for measurement control and laboratory use EN 55022 1994 A1 1995 A2 1997 Radiated Emissions Class A EN 61000 4 2 1999 Electrostatic discharge 4kV contact discharge 8kV air discharge EN 61010 1 2001 Safety requirements for electrical equipment for measurement control and laboratory use 43 LeCroy Corporation 700 Chestnut Ridge Road Chestnut Ridge NY 10977 6499 Tel 845 578 6020 Fax 845 578 5985 Internet www lecroy com 2004 by LeCroy Corporation All rights reserved LeCroy ActiveDSO ProBus JitterTrack WavePro WaveMaster WaveSurfer and Waverunne
8. OWER switch to the 0 side the power is turned OFF and the black indication is shown See Figure 25 LeCroy WS BATTERY niii Oian Bostery Name label POWER switch a MADE N JAPAN a Macufectered by RTE TENT PENTEL MET COE for LeCroy Corp N WARNING EES I TO AVOND ELECTRIC SHOCK ALWAYS CONNECT SCOPE GROUND neers LTO BANIN GROUND UNIEN SCOPE 10 POMERED BY A A pancer KEEP BATTERY PACK AWAY FROM PRE DO NOT SHORT OnEcTLY CONNECT POSITIVE AND NEGATIVE DO NOT OPEN OR EXPOSE TO HEAT ABOVE 60 DEGREES C REFER TO USER MANUAL FOR ADOMONAL SAFETY AND DISPOSAL INFORMATION DUE TO TRANSPORTATION REGULATIONS THIS BATTERY MUST BE SHIPPED AS CLASS 9 HAZARDOUS MATERIAL Figure 25 POWER Switch 38 Accessory c Charge Status Indicators Charge status indicator LED lamps and Push to Test switch battery mark as shown in Figure 26 are provided at the upper portion of the name label Figure 22 The following describes the indication contents Push to test switch Charge status lamps Red LeCroy WS BATTERY BATTERY PACK NOM 22 2V 8 4Ah Lithium lon Battery PUSH MADE IN JAPAN Manufactured by WATSU TEST INSTRUMENTS CORP for LeCroy Corp Figure 26 Charge Status Indicators 1 Contents of charge status LED lamp indications When pressing the Push to Test switch shown in Figure 26 the remaining battery charge level is shown for 4 seconds as described in Table 2 Seven kinds of battery
9. Requirements on pages 3 to 7 LeCroy WS BATTERY BATTERY PACK NOM 22 2V 8 4Ah Lithium lon Battery PUSH MADE IN JAPAN Manufactured by WATSU TEST INSTRUMENTS CORP for LeCroy Corp ZA WARNING TO AVOID ELECTRIC SHOCK ALWAYS CONNECT SCOPE GROUND TERMINAL TO EARTH GROUND WHEN SCOPE IS POWERED BY BATTERY PACK Z DANGER KEEP BATTERY PACK AWAY FROM FIRE DO NOT SHORT DIRECTLY CONNECT POSITIVE AND NEGATIVE TERMINALS DO NOT OPEN OR EXPOSE TO HEAT ABOVE 60 DEGREES C REFER TO USER MANUAL FOR ADDITIONAL SAFETY AND DISPOSAL INFORMATION DUE TO TRANSPORTATION REGULATIONS THIS BATTERY MUST BE SHIPPED AS CLASS 9 HAZARDOUS MATERIAL Figure 22 Name Label 36 Accessory 2 Output Charge control label See Figure 23 The following label is attached to the right of the name label This label shows the input for the charge control and the output of the DC OUT cable A CHARGE CONTROL Figure 23 Output Charge Control Label 3 BATTERY PACK label See Figure 24 The following label is attached to the rear plate surface of the BATTERY PACK oscilloscope mating surface and it shows that the rechargeable manganese lithium ion battery can be recycled Figure 24 BATTERY PACK Label 37 BATTERY PACK User s Manual b POWER Switch Move the POWER switch on the BATTERY PACK to the 1 side The power is turned ON and the green indication is shown On the contrary when moving the P
10. UT cable is connected to BATTERY IN 1 on the rear panel of the oscilloscope click Next Battery Management Wizard gt WS BATTERY Connect the DC OUT cable to BATTERY IN 1 on the rear panel of the oscilloscope For details about how to connect the cable see the instruction manual supplied with the WS BATTERY If this cable is not connected you cannot make the management function enabled Next Cancel Figure 8 Dialog Box Prompting You to Check that the DC OUT Cable Is Connected Properly 23 BATTERY PACK User s Manual 11 The following dialog box is shown while the battery management function is being set enabled Battery Management Wizard WS BATTERY The battery management function is being set enabled now Please wait for a while Figure 9 Dialog Box that Appears while the Battery Management Function Is Being Set Enabled 24 Accessory 12 When the following dialog box appears the battery management function is made enabled after restarting Click Restart Now The oscilloscope will be restarted automatically Battery Management Wizard gt WS BATTERY The battery management Function is made enabled after restarting Windows Restart Now Restart Later Figure 10 Dialog Box that Appears when the Setup Process Is Completed 25 BATTERY PACK User s Manual 13 Follow the steps below to check that the battery management f
11. Unpacking of BATTERY PACK 11 BATTERY PACK User s Manual e Transporting the BATTERY PACK The BATTERY PACK has an aggregate Lithium equivalent greater than 8 grams and falls into the regulatory category of Hazardous Materials class 9 miscellaneous dangerous goods Packaging used to transport the BATTERY PACK must meet the Class 9 Dangerous Goods transport requirements and relevant packing instructions Before shipping the BATTERY PACK consult with your transportation company on specific measures required for shipment of this class of product Please refer to the Web page containing the MSDS Material Safety Data Sheet and United Nations test documents as follows http www lecroy com goto batteryinfo WARNING Due to transportation regulations this product must be transported as Class 9 hazardous material f Longevity of the BATTERY PACK The BATTERY PACK deteriorates while the cycle of the charge and the electrical discharge are repeatedly used Since the BATTERY PACK is a lithium ion battery the period that can be used according to the storage method and use conditions is restricted The expected longevity is 500 times at 20 C as the cycle length Since the BATTERY PACK uses an internal chemical reaction the performance decreases not only while being used but also while it is stored for a long term Please refer to page 10 for the storage method g Disposing of the BATTERY PACK Battery packs such as this
12. Wewavesurrer Accessory LeCroy WS BATTERY BATTERY PACK User s Manual LeCroy WaveSurfer is a trademark of LeCroy Corporation Windows is a registered trademark or a trademark of Microsoft Corporation in the United States and other countries BATTERY PACK User s Manual Foreword Thank you for purchasing LeCroy s BATTERY PACK Before using the BATTERY PACK please read this manual thoroughly to gain a good understanding of it After reading please keep the manual in a safe place This manual describes notes on use and basic usage of the BATTERY PACK Notes Parts of the contents of this manual may be modified without prior notice for improvements in performance and functions Reproduction or reprinting of the contents of this manual without prior permission from LeCroy is prohibited If you have questions about this instrument please contact LeCroy Corporation Refer to the contact address given at the end of this manual Revision History June 2005 1st edition Accessory Checking the Packing Content On delivery of the instrument check each item If any of the items are missing or there is any damage immediately contact LeCroy or the sales office in charge Items to be present BATTERY PACK sisiran onaran nran arene rede r Enisi 1 Accessories Safety Ground Cale sicamor isinsi in E ests 1 User s ramvial EE feseasuveasoatenttersantsumeesasbertataseears 1
13. charge status are shown using the lit off and flashing states of the LED lamps Table 2 Meaning of Charge Status Indicators Battery charge status LED lamp status Sleep status Battery charging request status Remaining level 0 to 10 Remaining level 11 to 20 Remaining level 21 to 40 Remaining level 41 to 60 Remaining level 61 to 80 Remaining level 81 to 100 O Lit Off Flashing 39 BATTERY PACK User s Manual 2 Error indicators When turning ON the indication switch if an error occurs the error is indicated for 4 seconds At this time the LED lamp s is flashing at 2 Hz to show its contents Tables 3 and 4 show the error types during charging and discharging respectively Table 3 Error Indications During Charging Contents of LED indications Over current Charger is faulty LED lamps are flashing one by one Over voltage Charger is faulty LED lamps are flashing one by one Over charging Cell balance is faulty LED lamps are flashing one by one Temperature Faulty environmental LED lamps 1 3 and 5 temperature cell are flashing deterioration etc Table 4 Error Indications During Discharging Contents of LED indications Over current BATTERY PACK is LED lamps 1 3 and 5 faulty are flashing Temperature Faulty environmental LED lamps 1 3 and 5 temperature cell are flashing deterioration etc
14. ctly observe the warnings and cautions stated in this instruction manual to carefully handle the BATTERY PACK The following describes the overview of the BATTERY PACK conditions at shipment and how to store pack and transport the BATTERY PACK When using the BATTERY PACK strictly observe the contents of each description a Overview of BATTERY PACK This BATTERY PACK is composed of a rechargeable manganese lithium ion battery cell protective circuit and peripheral circuitry b When the BATTERY PACK is delivered The BATTERY PACK is generally shipped with approx 30 charged status of the rated capacity The BATTERY PACK is put in sleep status at shipment Sleep status Consumption of the internal circuit is minimized The BATTERY PACK doesn t return to the operating state if the charge operation is not done After the BATTERY PACK is delivered it is necessary to charge to full immediately with special charger WS BATT CHRG Moreover the BATTERY PACK enters sleep mode when electrical discharge not charging lapses for a certain period to minimize power consumption In this case neither lighting LED of the remainder amount display etc nor the output control with the POWER switch can be done It is necessary to charge with the BATTERY PACK to release this sleep mode BATTERY PACK User s Manual c Storing the BATTERY PACK Since a temperature of 25 C or higher has the possibility to deteriorate the BATTERY
15. d Connect the DC OUT cable to BATTERY IN 1 on the rear panel of the oscilloscope For details about cable connection see the instruction manual supplied with the WS BATTERY Cancel Figure 6a Dialog Box that Appears when Using the Battery Management Function for the First Time 20 Accessory Battery Management Wizard ed WS BATTERY The battery management Function is already set enabled Restart Battery Management Function Figure 6b Dialog Box that Appears when the Battery Management Function is Already Active Battery Management Wizard x WS BATTERY Since this oscilloscope does not have any hardware for the battery management the battery cannot be used For details about how to add hardware For the battery management to the oscilloscope contact the sales person local sales representative or service department of LeCroy Corporation J Figure 6c Dialog Box that Appears when the Hardware Is Not Applicable to the Battery 21 BATTERY PACK User s Manual 9 If the following dialog box appears click Exit XStreamDSO Software and then click Next Battery Management Wizard M WS BATTERY The battery management function cannot be made enabled while the XStreamDSO software is running Exit XStreamDS0 Software Figure 7 Dialog Box that Appears when the XStreamDSO Software Is Running 22 Accessory 10 After checking that the DC O
16. e discharge cycle has been performed 500 times at an atmospheric temperature of 20 C 2 C under conditions stated in 2 Since this product is a lithium ion battery the period that can be used according to the storage method and use conditions is restricted The longevity that can be expected is 500 times the cycle length 5 Numeric value in parentheses _ shows the discharging capacity when compared to the fully charged level 41 BATTERY PACK User s Manual b Product Specifications 2 of 2 lt Environmental specifications gt Temperature Operating Charge Discharge 5 C to 40 C Storage non operating 20 C to 45 C Humidity 30 RH to 90 RH Altitude Operating Charge Discharge Up to 6 562 ft 2 000 m lt General specifications gt Outside dimensions 289 5 W x 62 0 H x 260 0 L mm Tolerance 2 mm Length of Safety Ground cable 2000 mm 20 mm Length of DC OUT cable 300 mm 20 mm Weight Approx 2 6 kg 6 Since operation or storage for an extended period of time under high humidity conditions may lead to malfunction avoid such operation or storage 7 Please charge with the BATTERY PACK at the temperature within the range of 5 C to 40 C There is a possibility of the damage of the BATTERY PACK and leaking electricity when charging it outside this range 8 The BATTERY PACK is suitable for use in the range of 5 C to 40
17. e oscilloscope use the BATTERY IN 2 connector on the rear of the oscilloscope The following describes how to replace the BATTERY PACK and how to use the BATTERY IN 2 connector 1 Connect the DC OUT cable of the BATTERY PACK 2 to the BATTERY IN 2 connector on the rear of the oscilloscope NOTE 1 Make sure that the BATTERY PACK 2 is charged fully Turn ON the POWER switch of the BATTERY PACK 2 to be replaced The LED lamp next to the BATTERY IN 2 connector is lit Turn OFF the POWER switch of the BATTERY PACK 1 Disconnect the DC OUT cable of the BATTERY PACK 1 from the BATTERY IN 1 connector Mount the BATTERY PACK 2 on the rear of the oscilloscope NOTE 2 To ensure the operational safety always mount the BATTERY PACK on the rear of the oscilloscope When mounting the BATTERY PACK pay special attention so that the DC OUT cable is not disconnected from the BATTERY IN 2 connector For details about how to mount the BATTERY PACK see b Mounting the BATTERY PACK on the Oscilloscope in the section Operating Procedures on pages 30 and 31 of the instruction manual NOTE 3 After the battery has been replaced do not connect two BATTERY PACKs to the BATTERY IN connectors for an extended period of time 35 BATTERY _PACK User s Manual E Labels and Indicators a Labels The following labels are attached to the BATTERY PACK 1 Name label See Figure 22 Please observe the message and see Safety
18. e for the fist time Additionally always carry out the following operation steps in an environment where the AC power can be connected a Making the Battery Management Function Enabled When using the BATTERY PACK WS BATTERY with the oscilloscope for the first time follow the steps below to make the battery management function enabled and to restart the operation NOTE During the following work supply the AC power to the oscilloscope and never turn OFF the power during this procedure 1 Connect the power cord to LINE on the rear panel of the oscilloscope 2 Connect the DC OUT cable of the fully charged BATTERY PACK to BATTERY IN 1 or BATTERY IN 2 on the rear panel of the oscilloscope NOTE For details about how to connect the DC OUT cable see the section C Connecting the DC OUT Cable on page 19 in this instruction manual 3 Turn ON the POWER switch on the BATTERY PACK Make sure that the green LED to the left of BATTERY IN is lit NOTE For details about POWER switch see the section d Starting up the Oscilloscope on page 20 in this instruction manual 4 Turn ON the ON STANDBY switch on the front panel of the oscilloscope to turn ON the power 5 Wait until the XStreamDSO software is started up completely 18 Accessory 6 From the File menu select Exit to close the XStreamDSO software 7 From the Start menu of Windows select Programs gt LeCroy gt
19. ersonal injury or loss of life It is also important to remember not to connect a grounded device such as a computer or printer to the oscilloscope while it is floating To connect a grounded device to the WaveSurfer oscilloscope while using the Battery the ground cable must be connected between the oscilloscope and earth ground WARNING To avoid electric shock always connect scope ground terminal to earth ground when WaveSurfer oscilloscope is powered by the BATTERY PACK CLEANING The outside of the BATTERY PACK hardware should be cleaned with a soft cloth dampened with either deionized distilled water or isopropyl alcohol Allow the surface to dry completely before returning the instrument to service USE AND MAINTENANCE The BATTERY PACK is a high quality precision instrument To maintain accuracy mechanical shock should be avoided as well as damage to the cables through excessive bending All maintenance and component replacement should be referred to qualified personnel BATTERY PACK User s Manual E Product Disposal and Recycling This electronic product is subject to disposal and recycling regulations that vary by country and region Many countries prohibit the disposal of waste electronic equipment in standard waste receptacles For more information about proper disposal and recycling of your LeCroy product please visit www lecroy com recycle Accessory m Handling the BATTERY PACK Always stri
20. eting the BATTERY PACK Operation After the power of the oscilloscope has entered the standby mode follow the steps below to complete the BATTERY PACK operation 1 Turn OFF the POWER switch of the BATTERY PACK 2 Disconnect the DC OUT cable from the BATTERY PACK f NOTE 3 NOTE 4 If the oscilloscope is driven by the DC power and it is not operated for an extended period of time follow steps e and f described above to complete the oscilloscope operation and turn OFF the POWER switch of the BATTERY PACK If you do not follow warnings displayed on the screen and you operate the oscilloscope continuously the electric power of the BATTERY PACK is consumed and the output voltage supplied to the oscilloscope is interrupted forcibly 33 BATTERY _PACK User s Manual g Removing the BATTERY PACK from the oscilloscope 1 With the upper and lower tabs at two locations on the right kept pushed pull the BATTERY PACK slightly toward you to remove it Tab Figure 21 Removal of BATTERY PACK 2 Slide the BATTERY PACK in the direction opposite to that shown in Figure 16 on page 17 slide rightward to disengage the tabs on the left from the slots in the oscilloscope 34 Accessory E Replacing the BATTERY PACK If the BATTERY PACK is used to drive the oscilloscope for an extended period of time it is necessary to replace the BATTERY PACK To continuously operate the oscilloscope without powering OFF th
21. gure 18 Fastening of BATTERY PACK c Connecting the DC OUT Cable to the Oscilloscope After the BATTERY PACK has been mounted on the oscilloscope follow the steps below to connect the DC OUT cable 1 Connect the DC OUT cable of the BATTERY PACK to the BATTERY IN 1 or BATTERY IN 2 connector at the upper right portion of the rear of the oscilloscope See Figure 19 NOTE Pay special attention so that the BATTERY IN connector position meets the orientation of the positive and negative terminals Do not connect the DC OUT cable to the DC IN connector Sie gt a BATTERY IN position of oscilloscope ae A BATTERY IN 1 BATTERY IN 2 SO 120 DE IN 19 25 A cour 7A MAX DC OUT cable connector Figure 19 Connection of DC OUT Cable 31 BATTERY PACK User s Manual d Starting Up the Oscilloscope After the oscilloscope and BATTERY PACK have been connected with the DC OUT cable follow the operation steps below to start up the oscilloscope 1 Turn ON the POWER switch on the BATTERY PACK See Figure 20 POWER switch Green Figure 20 POWER Switch The BATTERY IN 1 or BATTERY IN 2 LED lamp on the rear of the oscilloscope is then lit This shows that the oscilloscope is ready for operation by the voltage supplied from the BATTERY PACK NOTE 1 When the AC power cord is connected to the rear of the oscilloscope and commercial power is supplied the operation of the oscilloscope b
22. harge LED lamp indications see the section Charge LED Lamp Indications on page 39 Indication switch Charge LED lamps Red LeCroy WS BATTERY BATTERY PACK NOM 22 2V 8 4Ah Lithium lon Battery PUSH MADE IN JAPAN Manufactured by IWATSU TEST INSTRUMENTS CORP for LeCroy Corp Figure 15 Charge Level Indication and Check 29 BATTERY _PACK User s Manual b Mounting the BATTERY PACK on the Oscilloscope 1 With the back plate of the BATTERY PACK matched with the rear of the oscilloscope align the tabs upper and lower portions 2 locations in total which are located on the left when viewed from the rear of the oscilloscope with the slots in the oscilloscope and slide them left to insert them into the slots See Figure 16 Rear of oscilloscope BATTERY PACK Tabs upper and lower portions 2 locations in total Figure 16 Mounting of BATTERY PACK A Left Side 2 Next align the tabs upper and lower portions 2 locations in total which are located on the right when viewed from the rear of the oscilloscope with the slots in the oscilloscope and insert them into the slots See Figure 17 Tabs Figure 17 Mounting of BATTERY PACK B Right Side 30 Accessory 3 Manually turn the screw knobs left and right portions 2 locations in total to fasten the BATTERY PACK to the oscilloscope See Figure 18 NOTE Tighten the left and right screw knobs evenly Screw knob Fi
23. loscope and commercial AC power is supplied the operation of the oscilloscope by the AC power takes precedence NOTE 2 The BATTERY IN 2 connector on the rear of the oscilloscope is used when replacing the BATTERY PACK to continuously operate the oscilloscope For details see the section Replacing the BATTERY PACK 13 BATTERY PACK User s Manual Rear of oscilloscope BATTERY IN BATTERY PACK WS BATTERY 10 20 CHARGE CONTROL i DC OUT cable Figure 2 Configuration of Oscilloscope Driven by DC Power with Use of BATTERY PACK When charging the BATTERY PACK the BATTERY PACK is connected to the BATTERY CHARGER WS BATT CHRG with the CHARGE CONTROL cable supplied with the BATTERY CHARGER and DC OUT cable as shown in Figure 3 below to charge the BATTERY PACK The output voltage is output from the BATTERY CHARGER to the DC OUT indicated on the label connector through the DC OUT cable during charging Additionally the charge voltage is input from the BATTERY CHARGER to the CHARGE CONTROL indicated on the label connector on the BATTERY PACK For details about how to charge the BATTERY PACK see the instruction manual for BATTERY CHARGER DC OUT cable BATTERY PACK ren OUT Battery charger WS BATT CHRG CHARGE CONTROL CHARGE CONTROL cable Figure 3 Configurations for Charging of BATTERY PACK 14 Accessory E Units a BATTERY PACK Figure 4a shows the outside view of this prod
24. r are registered trademarks of LeCroy Corporation Information in this publication supersedes all earlier versions Specifications subject to change without notice WaveSurfer Accessory WS BATTERY LeCroy
25. rge level of approximately 30 When using this product for the first time always charge it before starting the operation If this product is used not charged fully this may cause the product to deteriorate If the output of this product drops a relevant message will appear on the screen of the oscilloscope If this occurs follow the message to replace the BATTERY PACK with a fully charged one or to turn OFF the power to the oscilloscope If the product is used continuously as it is the output voltage drops and the discharge protective function is activated to shutdown the output causing the oscilloscope to be faulty or the data to be corrupted Stop the charging if it is not completed after a charging time of approximately 3 hours at room temperature By pressing the battery mark on the name label of this product the LED lamps five levels are lit to show the remaining battery charge level These LED lamps are lit during charging If the remaining battery charge level exceeds 80 five LED lamps are lit in red When the charging is completed the CHARGE lamp on the battery charger goes off and five LED lamps red also go off If the charging is not completed even after a specified period of charging time has elapsed contact sales office of LeCroy Corporation Do not make the positive and negative terminals of this product short circuited and do not use the product with the positive and negative terminals reversed
26. rge level of the BATTERY PACK becomes 10 or less the following warning message will appear E ow Battery You should change your battery or switch to outlet power immediately to keep from losing your work Figure 14 Warning Message that Appears If the Remaining Battery Charge Level Is 10 or Less 3 Ifthe remaining battery charge level of the BATTERY PACK becomes 5 or less the battery management function closes shuts down the oscilloscope operation 4 If the remaining battery charge level of the BATTERY PACK is already 5 or less when the oscilloscope is started up the oscilloscope operation is shut down 28 Accessory E Operating Procedures Operate the BATTERY PACK using the following procedures a Checking the Remaining Battery Charge Level of the BATTERY PACK 1 An indication switch used to check the remaining battery charge level is provided at the upper portion of the name label of the BATTERY PACK as shown in Figure 15 To check the remaining battery charge level press this switch 2 Five charge LEDs are arranged to the right of the indication switch The remaining battery charge level is shown by lit or flashing LED lamps If the remaining battery charge level is small connect the BATTERY PACK to the BATTERY CHARGER WS BATT CHRG to charge it NOTE 1 For details about how to charge the BATTERY PACK see the instruction manual for BATTERY CHARGER NOTE 2 For details about description of c
27. series oscilloscopes Do not connect the DC OUT cable of the BATTERY PACK to any device other than a WaveSurfer oscilloscope Use of the BATTERY PACK and or the equipment it is connected to in a manner not specified by the manufacturer s may impair the protection mechanisms Connect and disconnect properly Do not disconnect the DC OUT cable while the product is operating Doing so may cause the product to malfunction or the data to be corrupted Do not use in wet damp or explosive atmospheres For indoor use only The BATTERY PACK is intended for indoor use and should be operated in a clean dry environment Do not operate with suspected failures Do not use BATTERY PACK if any part is damaged All maintenance should be referred to qualified service personnel Keep product surfaces clean and dry Before mounting this product always check the connecting procedures stated in this instruction manual For safety reasons make sure to turn off the power switch of the product before carrying out wiring of the connectors and cables Turning on off the power switch controls the on off state of the output Always use the BATTERY CHARGER WS BATT CHRG to charge this product If a battery charger other than that specified is used this may cause an electric shock a fire or a malfunction Accessory Use this product after it has been charged fully This product is generally delivered with an initial remaining battery cha
28. tandard power cord the oscilloscope is connected to earth ground via the third wire in the AC power cord When operating the WaveSufer oscilloscope with the Battery there is no connection to earth ground and the oscilloscope is floating Operating the oscilloscope in this manner causes accessible metal parts to be at the same potential of the probe ground leads This results in a dangerous condition with the potential of elevated voltages present on the oscilloscope causing a shock hazard to the operator and also places stress on the power transformer insulation Over time this stress may result in dangerous failures which create a shock and fire hazard even during properly grounded operation Without AC power and the standard AC power cord the WaveSurfer oscilloscope is not grounded and will be floating unless the included grounding cable is connected between the oscilloscope and earth ground If the oscilloscope probes or channels are connected to circuits or devices that have voltages less than 30Vrms or 42Vpk from earth ground the ground cable is not required For any circuits where voltages greater than 30Vrms or 42Vpk may be present the ground cable must be connected If the operator is unsure if a higher voltage is present the ground cable should be used Operating the oscilloscope in the presence of these voltages without properly grounding the instrument may Accessory result in electrical shock which can result in serious p
29. the BATTERY PACK is delivered 17 E Operation Steps before Using the BATTERY PACK for the First Time rinane aene doin beni eee 18 a Making the Battery Management Function Enabled 18 b Oscilloscope Operation with Use of the BATTERY PACK 28 M Operating Procedures ccccceecceeesseeeeeeeneeeeeseeeeeeseeeeeesneeeesaes 29 a Checking the Remaining Battery Charge Level of the BATTERY PAG Ki 28 erect 200512 Bese eli Ud 2B Re ook atte EP ae Rte dt 29 b Mounting the BATTERY PACK on the Oscilloscope 30 E Replacing the BATTERY PACK E Labels and Indicators M Specifications cceeee c Connecting the DC OUT Cable to the Oscilloscope d Starting Up the Oscilloscope cceeescceeeseeeeeseneeeeesteeeeseaes e Completing the Oscilloscope Setup cccescceessseeeeeeteeees f Completing the BATTERY PACK Operation ccee a Product Specifications 1 Of 2 cccscccssscsessessessesessessesesseseeees b Product Specifications 2 Of 2 ccccscccsssceeesesteeeessseeeeseeeees c Certifications c Accessory E Safety Requirements This section contains information and warnings that must be observed to keep the BATTERY PACK operating in a correct and safe condition You are required to follow generally accepted safety procedures in addition to the safety preca
30. the POWER switch can be done The BATTERY PACK enters sleep mode when electrical discharge not charging lapses for about five days period with a remaining battery charge level of less than 40 Please give the BATTERY PACK a full charge at once with special charger WS BATT CHRG when the BATTERY PACK is delivered Please refer to the BATTERY CHARGER manual for the method of charging with the BATTERY PACK When the charging of the BATTERY PACK begins sleep mode is released It is necessary to fully charge the BATTERY PACK at least once every six months to prevent deterioration of the BATTERY PACK in performance and longevity when storing it for a long term The electrical discharge characteristics for reference are shown in Table 1 when storing the BATTERY PACK at high temperature or for a long term Table 1 Electrical Discharge Characteristics Storage temperature Storage period lectrical discharge duration 30 days Approx 3 02Ah 6 months Approx 1 93Ah 30 days Approx 2 18Ah x The electrical discharge duration service capacity is the data that is measured after the BATTERY PACK is charged at temperature 20 C 2 C and is discharged by 50 and is stored within the conditions shown in the above table 17 BATTERY PACK User s Manual E Operation Steps before Using the BATTERY PACK for the First Time The following operation steps are needed only when using the BATTERY PACK for the oscilloscop
31. uct syne screw POWER switch a ae ns Charge LED Name label Output Charge control label Rubber foot 5 locations Unit mm Figure 4a Outside View of BATTERY PACK 15 BATTERY PACK User s Manual b DC OUT Cable The DC OUT cable is supplied with the BATTERY PACK and it is connected to the BATTERY IN 1 or BATTERY IN 2 connector on the rear of the oscilloscope Figure 4b shows the outside view of the DC OUT cable 2 pin connector consisting of positive and negative terminals is provided on the DC OUT cable as shown in Figure 4b The connector shape is so designed that it is connected with its correct orientation When connecting the DC OUT cable to the BATTERY IN 1 or BATTERY IN 2 connector so that the connector shape is matched with the shape of the mating connector on the rear of the oscilloscope the polarities become correct CAUTION Pay special attention so that the positive and negative terminals of the DC OUT cable are not short circuited To rear of oscilloscope ees BATTERY PACK v FF J o NA 2 pin connector Figure 4b Outside View of DC OUT Cable 16 Accessory E When the BATTERY PACK is delivered The BATTERY PACK is put in the sleep status at shipment Sleep status Status in which the consumption of the internal circuit is minimized Neither lighting LED of the remainder amount display etc nor the output control with
32. unction is set enabled Select the Start menu gt Control Panel gt Power Options CAUTION Various settings displayed in Power options dialog are set to optimize WaveSurfer Please do not change these settings Power Options Properties Power Schemes Alarms Power Meter Advanced Hibernate el Select the power scheme with the most appropriate settings for A this computer Note that changing the settings below will modify the selected scheme Power schemes Home Office Desk v Settings for dore n Desk power scheme When computer is Plugged in Running on Turn off monitor Never N ever Turn off hard disks Never Never System standby Never Never Figure 11 Power Options Dialog Box 26 Accessory 14 When the Power Meter tab is shown this means that the battery management function is set enabled Power Options Properties Power Schemes Alarms Power Meter Advanced Hibemate o Power status Current power source AC power Total battery power remaining 100 Figure 12 Power Meter Dialog Box 27 BATTERY PACK User s Manual b Oscilloscope Operation with Use of the BATTERY PACK 1 When the oscilloscope is operated by the BATTERY PACK the following icon is automatically shown on the taskbar 100 remaining iUa Hivi Tuesday Figure 13 Battery Icon Shown on Taskbar 2 Ifthe remaining battery cha
33. utions specified in this section Safety Symbols amp Terms The following symbols amp terms may appear on the product and they alert you to important safety considerations This symbol is used where caution is required Refer to the accompanying information or documents in order to protect against personal injury or damage to the BATTERY PACK This symbol warns of a potential risk of shock hazard The CAUTION sign indicates a potential hazard It calls attention to a procedure practice or condition which CAUTION if not followed could possibly cause damage to equipment If a CAUTION is indicated do not proceed until its conditions are fully understood and met The WARNING sign indicates a potential hazard It calls attention to a procedure practice or condition which if not WARNING followed could possibly cause bodily injury or death If a WARNING is indicated do not proceed until its conditions are fully understood and met Before using this product ensure that its operating environment will be maintained within these parameters Temperature 5 to 40 C Humidity 30 RH to 90 RH non condensing Altitude Up to 2000 m BATTERY PACK User s Manual CAUTION To avoid personal injury or damage to the BATTERY PACK or the WaveSurfer oscilloscope connected to it review and comply with the following safety precautions Use only as intended The BATTERY PACK is intended to be used only with the LeCroy WaveSurfer
34. y AC power takes precedence The BATTERY PACK automatically switches to the DC power supply operation when the AC power supply is interrupted even though the AC power supply powers both the AC power supply and DC power supply Moreover the BATTERY PACK automatically switches to AC power supply operation if the AC power supply is connected while the DC power supply is used In these cases the switch time of about one second is necessary for the power supply switch in WaveSurfer If the AC power supply is connected and the DC power supply is turned off at the same time or the cord is pulled out when the DC power supply is used WaveSurfer terminates abnormally and data is corrupted because the power supply is interrupted during the switch time 32 Accessory 2 Turn ON the ON Standby switch at the lower left portion of the front panel of the oscilloscope The oscilloscope is then started up NOTE 2 The alert message is displayed on WaveSurfer screen in page 28 Figure 14 when the charge remainder is low At this time follow the instructions that appear on the screen Additionally even though the oscilloscope is driven by the BATTERY PACK you can check the remaining battery charge level using the procedures stated on page 17 e Completing the Oscilloscope Setup Follow steps 1 and 2 stated in Quick Reference Guide supplied with the oscilloscope see pages 7 and 8 to complete the oscilloscope setup Compl