1. The manufacturer declines all responsibility for damage caused by failure to follow instructions lack of maintenance and any unauthorized modification SKI 4 2 Contents of package The instrument is delivered complete with the following paris 1 Universal attachment 2 Power supply cable 3 User manual 3 Installation The shaker incubator should be installed in follow conditions Dry clean and stable work table with a flat horizontal surface Respect minimum spaces of 30 cm around instrument Power supply socket with earth connection Power feed between 220 240 V 50 Hz ee IM 3 1 Instrument parts Picture 1 User manual Room temperature between 15 C and 35 C maximum relative humidity 85 Opening closing handle SKI 4 User manual 4 Display and commands OPERATING MODE PV1 Display MEASURED ON OFF FAN SPEED Displav PV2 Display MEASURED TEMPERATURE SV Display SETTING VALUE PV3 Display TIMER Picture 2 ADJUSTMENT buttons START STOP button MODE button MOVING button Picture 3 SKI 4 User manual DISPLAY COMMAND DESCRIPTION The PV1 display shows the speed value measured by the instrument PV Display The PV2 display shows the temperature value measured by the instrument The PV3 display shows the timer value that may be a finite value or signalize the continuous operating mode SV Display
2. During the setting phase the SV display set value shows in sequence the parameters temperature speed and time During the working cicle it shows the set temperature lt shows the operating mode of the instrument RUN the instrument is working STOP the instrument is switched on but in standby This indicates the working phase of the fan inside the chamber lt shows the percentage of electric power absorption of the instrument th By repeatedly pressing of the MODE button you can proceed to MODE BUTTON the modification of the various operating parameters of the instrument START STOP BUTTON It allows you to start or stop the process of the instrument They allow you to increase or decrease the value of the parameter you are editing The shift key allows you to quickly move between the digits of the value that you are editing On off button SKI 4 User manual 5 Operation 5 1 Switching on the instrument Connect the power cord to a power outlet with a protective ground connection Switch on the shaking incubator with ON OFF button on the right side of the instrument The display light on and the instrument is ready to start with the parameters set during the last operation NOTE if the instrument had finished a process before being switched off it will display on the display End and make beep To stop the buzzer press any key 5 2 Setting of parameters With th
3. SHAKING INCUBATOR ARGO User manual SKI 4 User manual Contents VARA anirame na Rana E E E E E 1 2 CoOn tents of package pe RD RR ee 2 S AUO ee E seimae ince an em seam aednctin cum ceamaednetan 2 3 1 Instrument DAIS is cutstinetsnddcemiNsdacednidianisMidicnlsntdieniMidicelsubdianiahidiceiseidiesiaidiend subdue sieidided seid 2 A DEPAY GIG COMM ANS caga teres reer E GC Cuenca RE E E CA Ep a 3 3 OPCAO EE ee ee re 5 5 1 Switching on the instrument erre eee erre aerea eee a een cre n rena crea nao 5 De OCO pa ae enin E EE E aE EEE EEE 5 5 2 1 Temperature ceca teaser eai seis be id ia q a ia ada 5 D22 OMNO PEE eee ene eee eee ee eee eee ee ee ee eee eee 5 oye NO eee eee eee een ee ee ee ere ne TR 5 5 3 Start stop of cycle of operation e ererereree arena rea aa er ea rre narra area 6 O LUIS ge a o 6 LP PUZLO AM EO ZION E jr a ctamandmstan T sida sam andnstin ein EEE A A 7 8 Disposal of electronic equipment eee erre aeee aee a caneca acena cena naanao 7 SKI 4 User manual 1 Warranty Thank you for purchasing an ARGO LAB instrument In normal use conditions the instrument is guaranteed for a period of 24 months from the date of purchase The warranty is valid only if the product is original It does not apply to any product or parts of it that have been damaged due to incorrect installation improper connections improper use accident or abnormal conditions of operation
4. e display would display the following message SKI 4 User manual 7 Pulizia e manutenzione Proper maintenance and cleaning of the instrument guarantee its good conditions It s possible to clean with any detergent provided it is not aggressive and or corrosive You should clean the inside and outside surfaces with a standard all purpose cleaner sprayed on a soft cloth Before proceeding with any cleaning or decontamination the user must ensure that the method used does not damage the instrument IMPORTANT lf the instrument must be returned for service it is necessary to provide for proper cleaning and possible decontamination by pathogens of the same It is also recommended to put the instrument in its original packaging to send it in for repairs 8 Disposal of electronic equipment The electrical and electronic equipment marked with this symbol may not be disposed of in landfills In accordance with EU Directive 2002 96 EC the European users of electrical and electronic equipment have the opportunity to give back to the distributor or manufacturer upon purchase of a new one The illegal disposal of electrical and electronic equipment is punished with an administrative fine
5. e instrument switched on it s possible to modify the operating parameters inside the setting mode using the button MODE Pressing short press more times the MODE button the SV display set value shows the different parameters in the follow sequence TEMPERATURE STIRRING SPEED TIMER NOTE All parameters can be changed also while the instrument is working 5 2 1 Temperature With the instrument in stanby phase or during the operation pressing one time the MODE button short press the SV display blink and shows the temperature value set in that moment Use the amp button to increase and decrease the value of temperature from RT 5 C to 60 C Press again the MODE button short press to confirm the value and pass to the next parameter 5 2 2 Stirring speed With the instrument in stanby phase or during the operation pressing one time the MODE button short press the SV display blink and shows the temperature value set in that moment Use the amp button to increase and decrease the value of speed from 40 to 300 rpm Press again the MODE button short press to confirm the value and pass to the next parameter 5 2 3 Timer With the instrument in stanby phase or during the operation pressing one time the MODE button short press the SV display blink and shows the temperature value set in that moment Use the amp button to increase and decrease the value of timer from O to 99
6. h and 59 min Press again the MODE button short press to confirm the value and pass to the next parameter NOTES The timer starts when you press the START button If you do not set a definite time but is left to the value 00 00 the instrument will work in continuous mode that will not stop until the operator stops it manually by pressing the STOP button SKI 4 User manual 5 3 Start stop of cycle of operation After setting of parameters it s possible start the operating cycle pressing the START button in long way about 4 seconds The instrument starts its working cycle and simultaneously also the timer staris To stop the working cycle press the STOP button The instrument stops the display shows End and it beeps NOTE To stop the buzzer press a keys 6 Alarms The instrument can make some acoustic visual alarms to report any anomalies TEMPERATURE EXCESS if the temperature measured by the sensor inside the instrument exceeds the set temperature by more than 3 C the heating would stop and the instrument would emit an audible warning The beep can be stopped by pressing any key MOTOR OVERLOAD if the motor has been in overloaded for more than 10 seconds due to excessive load fluctuations the instrument will emit an audible warning The beep can be stopped by pressing any key PROBLEMS ON TEMPERATURE SENSOR in the case where the temperature sensor has problems th