Home

BM04101 Molift Quick Raiser English - Rev H 08/05/2013

image

Contents

1. BM04101 Molift Quick Raiser English Rev H 08 05 2013 molift by Etac e Assemble the knee pad bracket on the col Locking wheel umn by removing the locking wheel Place the knee pad bracket around the column and on the bolt where the locking wheel is placed and tighten the locking wheel Make sure the bracket is placed with the level side up Fixing bolts for column Slide the driving handle onto the top of the column by guiding the head of the fixing knob into the T groove of the column The handle shall be pointing upwards as shown on the picture below Tighten the knob firmly when the handle is in the desired position Guide the wire of the hand control through the ring at the base of the drive handle The hand control has a hook enabling it to hang on the handle Page 7 of 20 molift by Etac e Attach the lifting arm to the trolley on the col umn ORI and QR2 On the trolley there is a small safe ty lock which has to be pushed up to ensure a correct attachment of the lifting arm on the trolley Open the safety lock and then guide the arm in place over the two bolts in the trol ley Lock the safety lock by pushing it down Be careful not to put fingers or similar under the lifting arm between arm and trolley Dan ger of personnel injury QR2 Place the lifting arm install the bolt and attach with the screws Torque 28 Nm Secure screws with Loctite 2701 e Place the batter
2. Find your distributor visit Molift com molift
3. 62 dB Operating forces Buttons on hand control 3 4 N Height of legs ca 100 mm Measurements 1 265 x 610 x 1 280 mm LxWxH All measurements in illustrations are in millime tres 00 Ir 1280 S9TL OSII 1730 245 360 610 BM04101 Molift Quick Raiser English Rev H 08 05 2013 1200 Page 12 of 20 Technical data Molift Quick Raiser 2 Weight complete lifter excl battery 37 4 kg incl battery 38 4 kg Weight disassembled Chassis complete 22 kg Column complete 11 9 kg Lifting arm U shape 3 5 kg Material Aluminium steel and plastics Motor Lifting motor 12 V DC Leg spreading motor 12 V DC Battery 14 4 V NiMH 2 2 Ah Battery charger Mascot type 2215 10 22 cells NiCd NiMH Protection IP24 Number of lift with fully charged battery 40 lifts 75 kg 50 cm molift Safe Working Load SWL 200 kg 560 Ibs Lifting range 0 850 mm under patient Lifting speed 28 mm sec 75 kg Turning diameter 1 450 mm Sound level max A weighted sound power level L 62 dB Operating forces Buttons on hand control 3 4 N Height of legs ca 100 mm Measurements 1 265 x 610 x 1 280 mm LxWxH All measurements in illustrations are in millime tres 17221 S9TL OSL 1280 q E 213 V oF g 1720 245 360 3 610 BM041
4. but if sliding too much before locking it may cause an uneven lift and discomfort for the patient Check that the rope has a knot in the end molift Using a V shaped arm e Fasten the sling to the lifting arm by pulling the ropes firmly into the rope locks from the inside and out as shown in the illustration When lift ing the patient the ropes will lock even tight er due to the weight of the patient The patient should grab and hold the handlebars of the lift ing arm if possible O If the patient is large and heavy it is recom mended to lock the rope from the outside and in to increase the width of the ropes This will reduce any pinching effect to the patients chest Using a U shaped arm Ona U arm the ropes is attached to the lifting arm by pulling them firmly from above into the rope locks as shown on the illustration Page 5 of 20 molift Move the Quick Raiser in front of the patient Movement and place it in such a way that the patient can place the feet on the footplate on the chassis If necessary help the patient placing the feet correctly The patient should not be standing straight up during movement this can be experi enced as uncomfortable Be careful during movement not to run into furni o The distance from the front edge of the lift ture walls doors etc er to the kneepads increases when they are moved upwards The lifter shall not be used to lift or move us e Ad
5. arm Trolley Knee support Legs FRONT forward direction of travel rg Page 3 of 20 molift General Safety precautions General Before putting a Molift Quick Raiser into operation the operator must ensure that the lifter and acces sories are in good working order especially with regards to safety A Molift Quick Raiser shall only be used when all safety devices and equipment is in place and fully operational The lifter must be taken out of service immediately or not returned to service if faults and or irregularities that may have influence on the safety are discovered Injury to personnel or equipment may occur if Molift Quick Raiser is Used in an incorrect manner and if e covers are removed by unauthorised personnel e used incorrectly e insufficient maintenance e load exceeds maximum limit The SWL stated on the lifter is the maximum load e unauthorised repair of electrical devices The lifter has an expected lifetime of 10 years or 30 000 lifts with max load SWL when all recommended service is performed Lift and transferring Molift Quick Raiser 1 and 2 have SWL Safe Working Load on 160 kg meaning that they are tested and approved for lifting patients up to 160 kg Molift Quick Raiser 2 has a SWL on 200 kg Attempts of lifting patients with a higher weight may lead to danger of personal injury The patient lifter may tip over if used incor rectly Ignorance of warnings and instru
6. nnns The equipment has been tested and is in full working order Yes E No H utn J q Date aaa sha SIENITO uuu uma aE E eA aE E qaykaqhiwasassakusqaqQkesascpasthuqya BM04101 Molift Quick Raiser English Rev H 08 05 2013 Page 18 of 20 C DECLARATION OF CONFORMITY molift y Etac Etac AS Etac Supply Gj vik Hadelandsveien 2 2816 Gj vik NORWAY Telephone 47 4000 1004 hereby declare that Molift QUICK RAISER 1 Molift QUICK RAISER 2 and Molift QUICK RAISER 2 patient lifters and that the accessoires used only together with this product are in conformity with The Council Directive concerning medical devices 93 42 EEC and according to this classified as medical equipment class 1 Expiration date 30 May 2017 Molift QUICK RAISER 1 2 2 is manufactured in conformity with the following national or international standards that also might implement a harmonised standard 1SO10535 2006 Hoists for the transfer of disabled persons Requirements and test methods e ISO 14971 2007 Medical equipment Risik analysis Notified body Danish Technological Institute Wood Technology NEMKO AS Gregersensvej 3 Gaustadalleen 30 DK 2630 Taastrup N 0314 OSLO Denmark Norway Tel 45 7220 2301 Tel 47 2296 0342 Title Site Manager Name Knut Martin Fresaker Company Etac AS Etac Supply Gj vik 30 05 2012 wr anm Il Date Signature BM04101 Molift Quick Raiser English Rev H 08 05 2013 Page 19 of 20
7. of movement of a per son The lifter is only intended for lift and transfer to and from a sitting position e Molift Quick Raiser 1 has fixed legs while Molift Quick Raiser 2 2 has spreadable legs e Molift Quick Raiser 1 and 2 has a lifting capac ity of 160 kg Safe Working Load SWL e Molift Quick Raiser 2 has a lifting capacity of 200 kg Safe Working Load SWL All three variants of Molift Quick Raiser is de scribed in this manual and when Molift Quick Raiser is written it applies for all three if not it is specified by number 1 2 or 2 Molift Quick Raiser 1 2 and 2 are CE labelled ac cording to Council Directive 93 42 EEC concern ing medical devices as medical equipment class 1 and has been tested and approved by third party according to standards IEC 60601 1 IEC 60601 1 2 and NS EN ISO 10535 2006 Before using the patient lifter Before using a patient lifter the operator must be trained accordingly Practice lifting a colleague and be lifted by others It is important not only to know how to move another person using the lifter but also how it is to be lifted Try out and practice using all the relevant slings for the different types of lifter and movement you may encounter Before lifting a person you should explain the procedure When using the lifter it s also important to use the correct sling and accessories according to e type of disability e Size e weight type of movement The lift
8. 01 Molift Quick Raiser English Rev H 08 05 2013 1200 Page 13 of 20 molift Labels and symbols The main label for the lifter is placed on the chas sis behind the column Nominal battery voltage and protection class imolift QUICK RAISER 2 Model name SWL maximum load SWL 160 kg 14 4V DC IP24 Part number Serial number as bar code number Read user manual Etac AS Etac Supply Gjovik Hadelandsvn 2 N 2816 Gj vik Norway 47 4000 1004 www molift com c Manufacturer Separate waste collection Indoor use only CSA tested Type BF Applied part and approved IEC 60601 CE mark molift QUICK RAISER On the left side of the column there is a short guide Read user manual Check that lifter has no damage or faults before use checklist before use Place user in upright position Position with near 90 in ankles and knees Attachment of sling on U shaped arm Attachment of sling on V shaped arm Lifting the user carefully user leaning backwards Explanation of symbols used in this manual This symbol is used to point out instructions and information related to work place safety where injury may occur if the information is disregarded or ignored Follow these instruc tions be careful and attentive at all times This symbol indicates important and useful information If taken into consideration it will help the operator of the lifter to
9. a damp cloth using an appro priate detergent Regular cleaning is recommend ed and should accordingly be added to internal routines Inspection should be performed to uncover unex pected damages or errors Monthly maintenance e Check that the lifter has no loose parts or vis ible damages e Remove hair and pile from the castors and ver ify that the castors rotates without abnormal friction e Verify that the contacts of the hand control and charger is firmly in place e Clean contact and hand control with spirit or similar to remove grease and dirt e Verify that the cables for the hand control ac tuator and charger are intact e Run the lifter up and down to verify that it runs normally e Take contact with your local Molift service rep resentative dealer if there are faults or errors Periodic inspection Molift recommend periodic inspection of the lifter once a year according to checklist on page 18 Pe riodic inspection is to be performed by authorized personnel One checklist is to be filled in and signed for each lifter after inspection The owner of the lifter is re sponsible for keeping the list for information BM04101 Molift Quick Raiser English Rev H 08 05 2013 molift Service The lifter has a service lamp on chassis which will give a signal when service of the lifter is required The service lamp gives a green light when the lift er can be used normally Er Service lamp The electronics m
10. aise the patient carefully until the buttocks are clear from the seating and tighten the belt Unlock the wheels on the lifter and move the patient to the next location BM04101 Molift Quick Raiser English Rev H 08 05 2013 Page 6 of 20 Assembly and disassembly Unpacking e The lifter comes in a cardboard box Verify that the box has no apparent damage If damaged check the contents and contact your dealer for assistance if components are damaged e The box contains as standard a chassis lifting column knee support lifting arm drive handle hand control battery battery charger power chord and documentation Parts from lifters with different lifting capacity must not be used Assembly The battery must not be in the battery holder on the column during assembly e Atthe bottom of the column there are two bolts for fixing the column to the chassis Loos en the bolts enough to slide the column into the chassis until the red arrow on the front is pointing on the edge of the chassis see pic ture Tighten the bolts properly with the Allen key on the top of the column see page 10 to fix the column to the chassis Both bolts must be attached to chassis The QR2 column has a pin in the bottom to be fitted in the chassis e If the column stops before the arrow has reached the edge you will have to retract the column and try turning the motor spline head to align it with the connector at the base of the column
11. c tions may lead to personal injury Read in structions carefully before attempting to lift anyone Pay close attention to your actions Ensure that both ropes of the sling are securely fas tened to avoid the user slipping or falling BM04101 Molift Quick Raiser English Rev H 08 05 2013 Use the drive handles when manoeuvring the lifter do not push or pull the patient or lifting arm Keep fingers arms or similar away from trol ley during use Danger of clamping between knee support and trolley Torn cut frayed or broken slings can fail re sulting in serious injury to the user Use slings in good condition only Destroy and discard old unusable slings Molift slings shall ONLY be used to lift per sons NEVER use the sling to lift and or move objects of any kind Molift QuickRaiser should not be run con stantly for more than 2 minutes with maxi mum load and rest for minimum 18 min utes If the expected movement does not start when the corresponding button is pressed please consult the fault finding table in the maintenance chapter to locate the fault A A 0 Several factors have to be considered during trans ferring Stand to the side of the user when lifting Ensure that arms and legs are clear of the lift chair bed etc Try to maintain eye contact with the user this will help the user feel safe and comfortable Medical electrical equipment requires spe cial precautions regarding electromagne
12. e separate form for sling Battery charger is an accessory Emergency stop and manual control have been checked and are in working order The lifter has been rolled over the floor preferably under load and moves easily and steadily Leg extender mechanism Quick Raiser 2 and 2 has been fully extended and retracted preferably under load and moves evenly and without noise stops in correct positions The lifter has been fully raised and lowered preferably under load and moves evenly and without noise Servicing unnecessary because the servicing lamp is on green and the lifter is under 5 years old Compulsory in case of faults under one of the above points The lifter has been removed from service and clearly marked OUT OF ORDER Completed Compulsory where lifter has been checked and approved The lifter has passed the safety check and been affixed with the Molift safety check label duly dated and signed The ticked and signed checklist has been passed to the client and a copy sent to your Molift dealer Comments OM Taults AICS ALIS L L LLULLU aaa aka PEPEES NENESE TOE ORE OEE NEEE Liiter Seria TO uuu u uu usa stans panas Other ID no il any uu au aasuaqasaaayaqqhusaquanaskisaqi Au s E ect SS S SS SSS S S A Inspection carried out by Block capitals IPTE Molift certification no if any for inspector repairer nn n en nennen nennen
13. easures the operating time of the lifter and after a specific time the service lamp will give a signal first yellow light then red in dicating that the lifter needs service Take contact with your local Molift service representative deal er The lifter can still be operated but after a while an audible alarm will sound to remind the opera tor that the lifter needs service immediately Service light codes Servicelight Mode Red Perform service Red sound Perform service immedi ately Flashing yellow Overheating Service includes control and change of worn or damaged parts The service partner uses the Molift Service Tool to read the data from the lifter and for logging serv ice and resetting the service LED The owner is re sponsible to ensure proper logging and written verification performed by authorised service part ner A list of spare parts is avalable on request Page 17 of 20 Checklist for periodic inspection of Molift Personal Lifters Molift Quick Raiser 1 2 and 2 Revision C 12 2008 COMPULSORY SAFETY CHECK annual OK Fault Corrected Visual inspection Whole lifter checked for damage cracks and deformation and found to be in good order Especially raising arm trolley with bolt column chassis wheels and all cables Lifter has been correctly assembled and no parts are missing Especially column attachment knee supports and raising arm Accessories have been checked Se
14. er must be taken out of service imme diately or not returned to service if faults and or irregularities that may have influence on the safety are discovered Page 2 of 20 Molift Quick Raiser use The hand control for Molift Quick Raiser 2 and 2 has four buttons two buttons for raising and low ering and two buttons for adjusting the legs in and out Molift Quick Raiser 1 has only two but tons for raising and lowering In addition there is a diode which gives a light when the battery needs charging Battery Up lamp Legs in Down Emergency lowering and Allen keys Hand control Drive handle em Battery Lifting column Control electronic incl service lamp battery lamp and electrical emer gency lowering Chassis BACK Emergency stop BM04101 Molift Quick Raiser English Rev H 08 05 2013 molift by Etac Check list before use 1 Check that the lifter has no visible damages or missing parts 2 Check that there are no loose parts verify that the lifting arm and column are properly fas tened 3 Check that the emergency stop is not activated and that the lifter is working 4 Check that the battery is charged battery lamp gives no light 5 Check that the service lamp gives a green light If service lamp gives a yellow or red light the lifter should be taken out for service Emergency stop Battery lamp no light Service lamp green light Lifting
15. g the button clockwise until it pops up Electrical emergency lowering does not work when emergency stop is activated Electrical emer gency lowering BM04101 Molift Quick Raiser English Rev H 08 05 2013 Emergency lowering It is possible to perform a emergency lowering if the lifter should malfunction Molift Quick Raiser has both manual and electrical emergency lower ing The manual lowering is done by turning the worm screw using an Allen key this can be found on the top of the column Puncture the label and use the small Allen key in the hole under the yellow label turn the worm screw until the patient is lowered enough Manual emergency lowering Allen key for column fixing bolts Allen key for manual emer J gency lowering Electrical emergency lowering can be found on the chassis Push the emergency lowering button and lower the patient Electrical emergency low ering does not work when the emergency stop is activated eb Replace labels if they are punctured to seal the lifter again Page 10 of 20 Technical data Molift Quick Raiser 1 Weight complete lifter excl battery 29 kg incl battery 30 kg Weight disassembled Chassis complete 15 2 kg Column complete 10 8 kg Lifting arm V shape 2 9 kg Lifting arm U shape 2 4 kg Material Aluminium steel and plastics Motor Lifting motor 12 V DC Battery 14 4 V NiMH 2 2 Ah Battery charger Mascot type 2215 10 22 cells N
16. hange battery with another or charge battery Bad or wobbly connection from lifting column to chassis clean contacts in column base and in side chassis adjust and tighten column bolts Emergency stop activated turn clock wise to reset Hand control disconnected re connect hand control The hand control has failed ex change hand control contact your local service representative Relays electronics malfunctions exchange electronics relays contact your local service repre sentative Motor has failed exchange mo tor contact your local service representative BM04101 Molift Quick Raiser English Rev H 08 05 2013 If you have access to more than one lifter it may be helpful to change parts across lifters to help identify any faults For instance if you suspect the fault to be inside the column exchange the col umn with at functional one from the other lifter to see if the problem is fixed If you are not able to solve the fault or problems by yourself using this manual please contact lo cal authorised service representative If you do not know whom to contact locally please contact your dealer or Etac Supply Gj vik to get help Page 16 of 20 Maintenance Cleaning Detergents must be pH neutral Do not use solvents or strong liquids this may damage surfaces on the lifter For disinfection when needed use isopropyl alcohol Avoid abrasive cleaning products Clean surfaces with
17. iCd NiMH Protection IP24 Number of lift with fully charged battery 40 lifts 75 kg 50 cm 1730 990 molift Safe Working Load SWL 160 kg 560 Ibs Lifting range 0 850 mm under patient Lifting speed 50 mm sec 75 kg Turning diameter 1 100 mm Sound level max A weighted sound power level L 62 dB Operating forces Buttons on hand control 3 4 N Height of legs 70 mm Measurements 1 070 x 610 x 1 280 mm LxWxH All measurements in illustrations are in millime tres 00 65 pa Y r D N 1 fi n i LI Hu Ne HT EI dius B w A em 1280 BM04101 Molift Quick Raiser English Rev H 08 05 2013 Page 11 of 20 molift Technical data Molift Quick Raiser 2 Weight complete lifter excl battery 36 5 kg incl battery 37 5 kg Weight disassembled Chassis complete 22 kg Column complete 11 7 kg Lifting arm V shape 2 9 kg Lifting arm U shape 2 4 kg Material Aluminium steel and plastics Motor Lifting motor 12 V DC Leg spreading motor 12 V DC Battery 14 4 V NiMh 2 2 Ah Battery charger Mascot type 2215 10 22 cells NiCd NiMH Protection IP24 Number of lift with fully charged battery 40 lifts 75 kg 50 cm Safe Working Load SWL 160 kg 560 Ibs Lifting range 0 850 mm under patient Lifting speed 50 mm sec 75 kg Turning diameter 1 450 mm Sound level max A weighted sound power level L
18. just the height of the kneepads so that the ers on sloping surfaces top of the pads are approx two finger widths under the kneecap Loose the locking wheel on the knee support bracket when adjusting Avoid deep pile carpets high thresholds uneven surfaces or other obstacles that may block the cas tors The lifter may become unstable if forced over such obstacles increasing the risk of tipping over If it is necessary to cross obstacles like a low door sill make sure to pull the lifter carefully straight over it with the big wheels first o The scale on the column can be used to note the correct height of the kneepads for differ ent users e Attach the strap to the kneepads around the The lifter shall only be used for movement users legs over short distances It is not a replacement for wheelchair or similar Lowering e Lower the patient into sitting position at the desired place If the patient is to be seated into a wheelchair please observe that the wheel brakes must be locked on the wheelchair when lowering but NOT on the lifter H Ti I i I i c r s a i e Loosen the strap around the users legs and re lease ropes from locks e Remove the lifter and remove the sling w If it proves to be impossible to place the leg perpendicular to the footplate you should pay extra attention when lifting to avoid over stretching the knee joint e R
19. molift QUICK RAISER molift by Etac C BM04101 Molift Quick Raiser English Rev H 08 05 2013 eL eI oo i e lada la molift Table of content About Molift Quick Raiser 1 2 and 2 2 Molift Quick Raiser use 3 Check list before use 3 General Safety precautions 4 Adjusting and transferring 5 Assembly and disassembly 7 Battery and charging 9 Safety devices 10 Technical data Molift Quick Raiser 111 Technical data Molift Quick Raiser 212 Technical data Molift Quick Raiser 22 13 Labels and symbols 14 ACCOSSOLIBS o sstvasssessocssvasacexecncssaseavas 15 Troubleshooting 16 Maintenance 17 Etac AS Etac Supply Gjovik Hadelandsveien 2 2816 Gj vik Norway Teleph 47 40001004 Fax 47 40001008 BM04101 Molift Quick Raiser English Rev H 08 05 2013 www molift com moliftaetac com About Molift Quick Raiser 1 2 and 2 Molift Quick Raiser is designed to cover the need for lift and transfer of patients who are to some ex tent capable to actively participate in the process The lifter has an exceptional design and the shape of the lifter and geometry of the lifting movement imitates the natural pattern
20. nded l SWL 160 kg weight Kg XS Light 20 30 50 65 E blue h Q All lifting straps are approved for 200 kg Rec ommended weight is only mentioned as a guide to choose the correct size BM04101 Molift Quick Raiser English Rev H 08 05 2013 Page 15 of 20 molift Troubleshooting Below you will find a table with fault finding pro cedures to identify and correct faults on the lifter Symptom Possible cause action Lifting column is Locking bolts are not properly wobbly secured or lifting column is not properly in place in the chassis check if the column is correct ly placed in the chassis and or tighten bolts Lifter only moves one way up or down legs only moves one way in or out Fault on hand control exchange with alterative control from other lifter and or new hand control One of the relays electronics has failed exchange the control unit relays contact your local service representative Short circuit between the hand control and lifter clean the con nectors of the hand control and chassis with spirits to remove grease and dirt The lifter moves up and or down by it self legs move by themselves The hand control has failed ex change hand control contact your local service representative Relays electronics malfunctions exchange electronics relays contact your local service repre sentative The lifting arm does not move legs does not move Discharged battery exc
21. s activated The lifter can be stored and trans ported under the following conditions Z wi The lifter is designed for use at standard room temperatures 5 to 40 C Following storage or transport at other temperatures leave the lifter in aroom with a suitable temperature until it reaches a safe operating temperature Pressure 70 106 kPa Humidity 15 93 Temperature 25 70 C Page 8 of 20 Battery and charging Battery care and charging Molift Quick Raiser is supplied with a battery with a 14 4 V cell unit that is placed in the battery hold er on the lifter A charger is also supplied to charge the battery whenever needed The charger can be mounted on a wall surface or placed on a table Battery Charging LED Mains cable Connect the charger mains cable to the wall sock et when charging the battery The Charger must be placed or installed in a way that makes it easy to disconnect mains cable Take care not to dam age the cable Charger has to be used outside the patient environment Place the battery in the charger After a few sec onds the charger LED will change from yellow to orange indicating that the battery is charging When the LED gives a constant green light the bat tery is fully charged The charger has a LED Light Emitting Diode indicating the status of the bat tery as described below No battery Battery capacity The battery light on the hand control will illumi nate if
22. the lifter rest until the lifter is cooled down enough for further use Discarded lifters and batteries should be han dled as electronic waste and collected sepa rately according to local laws and regula tions Page 9 of 20 molift Safety devices Molift Quick Raiser is equipped with several safety devices which are intended to prevent damage to personnel and equipment in case of incorrect use e The lifter has an overload sensor preventing the lifter to be operated with more than SWL e The lifting arm is hinged to prevent the arm from squeezing the patient if it is lowered too much e The lifting arm has rope locks on the lifting arms designed to lock the ropes on the lifting strap when they are loaded e When activating the emergency stop button the power supply will be disconnected and the lifter will stop e Ifan error occurs it is possible to lower the lift ing arm manual or electrical e The lifter has a service lamp which gives a sig nal when the lifter needs service Emergency stop and emergency lowering Contact a service partner if the cause of the stop or malfunction is unknown or if a fault is discovered The lifter is to be taken out of serv ice until the fault is repaired Emergency stop The emergency stop button is placed on the chas sis The emergency stop will cut the power sup ply to the motor when it is activated Activate by pushing the emergency stop button in and re set by turnin
23. the voltage of the battery falls below a cer tain level indicating the need for charging There is still enough capacity to perform 3 5 lift cycles initialization 10 sec BM04101 Molift Quick Raiser English Rev H 08 05 2013 molift 75 kg at this point The battery lamp on the chas sis will only illuminate when a hand control is not connected and the battery needs charging o If the battery is discharged during a lift it is always enough power to lower the user down again New batteries will not achieve full capac ity before it has been fully charged and dis charged a couple of times O The battery has a life expectancy of approx 500 charge cycles O Electrical system Emergency Service lamp Electrical Battery lamp stop emergency lowering On the right side of the chassis there is a service light which will give a signal when the lifter needs service When there is a green light the lifter can be used normally If there is no light push one of the up down buttons to activate the electronics and the service lamp will illuminate See the chap ter Maintenance The electronics has a power save function which makes the system sleep after a while with no ac tivity All lights will go out Activate the system by pushing one of the buttons on the hand control If the lifter is run up and down constantly for a longer period the electronics may be overheated and the lifter will stop Let
24. tic compatibility EMC Portable or mobile radio communication equipment may affect the medical electrical equipment and should be kept minimum 25 cm 10 inches from the lift ers electronics Page 4 of 20 Lifting Adjusting and transferring e Lower the lifting arm to the lowest position Alternatively adjust the legs of the QR2 QR2 to adapt to the lifting situation A To perform a comfortable lift for the patient it is recommended that the patient is sitting in a normal upright position with near 90 in ankles and knees It is also recommended that the patient is wearing suitable shoes or socks with good friction towards the floor If the patient is sitting in a wheelchair it is necessary to put on the wheel chair brakes Its also recommended to lock the wheels of the Quick Raiser when performing the lift Patients with an extremely high or displaced centre of gravity i e lameness on one side of the body or high weight on the upper body may cause the lifter to tip over Such patients should be lifted in a passive lifter i e Molift Partner or Molift Smart and not with an ac tive lifter like Quick Raiser e Place the Molift Easy Raiser sling around the back of the patient as far down as possible Connect the belt and tighten BM04101 Molift Quick Raiser English Rev H 08 05 2013 The ropes must be tightened firmly on the lift ing arm The rope will lock itself due to the weight of the patient
25. work ef ficiently It may help simplify routines and to explain complicated facts The safety control label is also placed on chassis behind the column CONTROL Control the lifter each 12 month according to list for periodic in spection on page 18 This label has desig nated space for the calendar and signed label that the service partners attach to the lifter when periodic in spection is performed Read user manual Page 14 of 20 molift Accessories Sling bag Part no 3048000 Molift Easy Raiser lifting strap Quick Raiser Sandals Molift Easy Raiser Pair of sandals size Small Part no 5020005 e Part no 452100 Part no 3020000 Pair of sandals size Medium Part no 452200 Pair of sandals size Large Molift Easy Raiser lifting strap with support e Part no 452300 Molift Easy Raiser with support Adjustable footplate XS Part no 3019003 Art no 451000 Part no 3019000 Part no 3019001 Extra padding for knee support Part no 3019002 Part no 3019004 Extra padding knee support small Separate support strap e Part no 0455111 XS S M Part no 3019011 j L XL Part no 3019012 Extra padding knee support large e Part no 0455114 Sling size guide Lifting arms Arm complete V shape e Part no 458107 Lifting arm for Molift Quick Raiser 1 and 2 SWL 160 kg Arm complete U shape The strap is adjustable e Part no 458010 Bacon Lifting arm for Molift Quick Raiser 1 and 2 oe me
26. y in the battery holder with the connectors facing down Run each function of the lifter a couple of times without load to veri fy that the lifter works BM04101 Molift Quick Raiser English Rev H 08 05 2013 Etac Supply Gj vik tests all lifters with and without load before shipment The control is an extra precaution to uncover any shipment damage and or incorrect assembly O Checklist Verify that the lifting arm is properly fastened to the trolley e Verify that the lifting column is properly placed into the chassis arrow shall be exactly aligned with the edge of the chassis e Verify that the column is properly fastened with bolts tightened Make sure that the lifter has no damage or cracks and that the lifting arm and column is properly fixed before use Disassembly e Remove the battery e Remove the lifting arm by opening the securi ty lock on the trolley at then pull out the lifting arm e Loosen the lock wheel for the drive handle and pull the handle with plate and locking wheel up and out of the column e Remove the locking wheel for the knee sup port and remove the complete knee support also possible to leave on the column Replace the locking wheel on the bolt on column to avoid it from getting lost e Loosen the column fixing bolts with Allen key and lift out the column Environment conditions For long time storage it is recommended that the battery is removed and the emergency stop but ton i