        FastTrak S150 SX4-M User Manual
         Contents
1.                                    41   Disk Array Terms    1 0    eee 41  Description  E DOCE 41  Memberi uu ner esta Est E goes 42   TYPOS  a obser A eI AR UAR CAR ERE e o us 42   About RAID Levels ssis INI cece eee ees 43  RAID O Strip    r  Ga eantg aed RU adhe eal Rp ee Ge 43   RAIDT  MITO 2 1i ic eic HpEE CENA Mia SR eed ed oe 44   RAID 071  Stripe Mirror                                 45   About Dual Data Redundancy                        46   RAID 5  Block and Parity Striping                         47   JBOD     Single Drive IA Aa ee ee 48  Chapter 6  Troubleshooting  amp  Tips                            49  Motherboard Issues           illl  49  System CMOS Issues                                     50  Drive Related Errors                                      50  Operating System Related Issues                            53  Performance Tips                                        54  Chapter 7  Support eet a ee a e AREE GERE 55  Frequently Asked Questions                                55  Pre Installation  Speed  Device Types  Capacity  Cabling     55   Drive ISSUES   y kou Ru ad aa Poder AA aad tod ss 57  Installation Issues  Capacity  Booting                      59  Post Installation            llli 60  Contact Technical Support                                 60  Limited Warranty             clseeeeeeree eee es 62  Return Product For Repair                                 63  Appendix A  Memory Upgrade Test                            65       vii    FastTrak 
2.                       35  Install Driver in an Existing System                                 36  Confirm Installation                                             36  Red Hat Linux 8 0  9 0   Install Driver During New OS Installation                            37  Install Driver in an Existing System                                 37  SuSE Linux 8 1  8 2   Install Driver During New OS Installation  Single Processor              38  Install Driver During New OS Installation  Multi Processor               38  Install Driver in an Existing System                                 38  Promise RAID Utility for Linux                                     39       29    FastTrak SX4030  SX4060  S150 SX4 M User Manual       Windows Server 2003    Install Driver During New OS Installation    1      Start the installation  Boot from the CD ROM  Press F6 after the message   Press F6 if you need to install third party SCSI or RAID driver  appears     When the Windows Setup window is generated  press S to specify an  Additional Device s    Insert the Promise Technology driver diskette into drive A  and press Enter   Choose Windows 2003 Promise FastTrak S150 SX4 SX4000 Series from  the list that appears on screen  and then press the Enter  1  Press S to use  the driver on the floppy disk and then press Enter to continue with  installation    The Windows 2003 Setup screen will appear again saying    Setup will load  support for the following mass storage devices   The list will include  Windo
3.                     co                                     sxam  PROMISE  FastTrak 5150    AU HU     O  S   Io oo  Cache Memory Socket SDRAM DIMM                                 DO                                     3   150 SX4 M  Attach one Serial ATA data cable to each hard drive  Then  attach the other ends of the cables to the connectors on the FastTrak card   above                                     409  10                                                   Ch3 Ch4 Buzzer LED Pins    PROMISE    FastTrak    bo o  gt  onini    Q  TT CTI     Cache Memory Socket SDRAM DIMM                                                                SX4030   SX4060  Attach the black end of the Ultra ATA cable to each hard  drive  Then attach the blue end to the ATA connectors on the FastTrak card   above      4  Attach the Y cable power splitters to each of the hard drives        FastTrak SX4030  SX4060  S150 SX4 M User Manual       You will now use the onboard FastBuild BIOS utility to create your first array  using the attached drives  For an explanation of the array options  see Chapter 3    of this manual   Important       Even if you plan to use the Promise Array Management Utility to  manage your array  you must still create your first array using the    FastBuild Utility  as described here        Boot your system  If this is the first time you have booted with the FastTrak    1   card and drives installed  the Promise onboard BIOS will display the    following screen  below      Ea
4.        17  Define Array ssc ee ek Ru rk ek 18  Define Array DefinitionMenu                               19  Create a RAID O Array                                 20  Change Stripe Block Size                             20   Assign Drives to a RAID O Array                      20   Set Gigabyte Boundary                             20   Save Array Information                              20   Create a RAID 1 Array                                 21  Create a Mirroring Array with Two New Drives          21  Change the Stripe Block Size                          21   Set Gigabyte Boundary                             21   Save Array Information                              21   Create a RAID 0 1 Array                               22  Assign Drives to a RAID 0 1 Array                    22   Define the ArayasaRAIDOF1                      22  Change the Stripe Block Size                         22   Set Gigabyte Boundary                             22   Save Array Information                              22       FastTrak SX4030  SX4060  S150 SX4 M User Manual       Create a RAID 5 Array                                 23  Change Stripe Block Size for RAID 5 Array              23  Assign Drives to a RAID 5 Array                      23  Set Gigabyte Boundary                             23  Save Array Information                              23  Hot SpareDrives                                     24  Partition and Format Array                             24  Set Disk Array as Bootab
5.    11    FastTrak SX4030  SX4060  S150 SX4 M User Manual       7  Press the arrow keys to move to Disk Assignments  Press the spacebar to  toggle between N and Y for each available drive     8  Assign the appropriate number of disk drives to your array  Refer to the chart                      below   Level Number of Drives  RAID 0 2 30r4  RAID 1 2 only  RAID 0 1 4 only  RAID 5 3or4  JBOD 1 2  3or4                A disk drive that is not assigned to an array will automatically function as a    Hot Spare Drive     9  Press Ctrl Y to save your array configuration     10  Press Esc to exit to the Main Menu  Press Esc again to exit the Utility     11  Press Y to confirm the new array and restart the computer     You have successfully created a new RAID array     Important       You must be partition and format your new array before you can  use it  Use the same method of partitioning and formatting on an  array as you would any other fixed disk added to your computer    system           Chapter 3  FastBuild    Utility    e Setup Quick Reference  below   Define  Create  Array  page 18     FastTrak BIOS Reference  page 15     Array Definition Menu  page 19     Main Menu  page 16   Delete Array  page 27   e View Drive Assignments  page 17   Controller Configuration  page 28    This chapter contains a Setup Quick Reference that is a checklist of tasks  needed to initialize your FastTrak SX4030  SX4060 or  150 SX4 M system   followed by a step by step instructional breakdown of each ta
6.    3     7   8   9     When the New Hardware Wizard appears  click Next   Insert the Promise FastTrak Driver diskette in the A  drive     Under Install Hardware Device Drivers  select Search for a suitable driver     and click Next     Under Locate Driver Files  uncheck Floppy disk drives and CD ROM drives   Check Specify a Location and click Next     Under Insert the manufacturer s installation disk  type A  win2000 and click  OK     Under Driver Files search Results  when a  Win2000 Promise Technology  Inc  FastTrak S150 SX4 SX4000 series  fastsx inf should appears  click  Next     If a Digital Signature Notice appears  click Yes   Under Completing the New Hardware Wizard  click Finish   Click Yes to restart your PC     10  Remove the Promise FastTrak Driver diskette     Note  Check the readme file  included with the downloaded driver files  for  instructions on installing the RAID Console     Confirm Installation    f     2   3   4    From the Windows Desktop  open the Control Panel from My Computer   Click on the System icon   Choose the Hardware tab  and then click the Device Manager button     Click the   in front of SCSI controllers  Win2000 Promise FastTrak S150  SX4 SX4000 Series should appear        36    Chapter 4  Installing Software Drivers       Red Hat Linux 8 0  9 0    Install Driver During New OS Installation  1  Start the RedHat Linux Installation by booting with the installation diskette or  bootable CD ROM     2  Atthe Welcome to Red Hat Linux     installa
7.   0   il    Insert the Promise FastTrak Driver diskette in the A  drive     When the New Hardware Wizard appears  select  nstall from a list or specific  location  advanced  and click Next     Under Please choose your search and installation options  select Don t  search    will choose the driver to install and click Next     Under Select the device driver you want to install  click Have Disk     Under Install from Disk  type A  winxp and click OK    Under Select the device driver you want to install  click Next    If a warning about Windows Logo testing appears  click Continue Anyway   Under Completing the New Hardware Wizard  click Finish    If the New Hardware Wizard appears again  close it    Click Yes to restart your PC    Remove the Promise FastTrak Driver diskette     Note  Check the readme file  included with the downloaded driver files  for  instructions on installing the RAID Console     Confirm Installation  1     ark WN    From the Windows Desktop  open the Control Panel from My Computer   Click on Performance and maintenance    Click on the System icon    Choose the Hardware tab  and then click the Device Manager button     Click the   in front of SCSI controllers  WinXP Promise FastTrak S150 SX4   SX4000 Series should appear        34    Chapter 4  Installing Software Drivers       Windows 2000    Install Driver During New OS Installation    de    Start the installation  Boot from the CD ROM  Press F6 after the message     Press F6 if you need to install third p
8.   utility  PAM User  Manual and FastTrak SX4030  SX4060  S150 SX4 M User Manual    If ANY of the contents are missing or appear to be damaged  please contact your  dealer or distributor immediately     SX4030   SX4060    When you receive the FastTrak SX400  Series card  the package should contain  the items listed below     FastTrak SX4000 Series Controller Card   64 MB SDRAM DIMM Memory Card   Quick Start Guide   FastTrak driver diskette   Four Internal 18 inch  46 cm  Ultra ATA  80 wire 40 pin hard drive cables  Two Y cable power splitters    CD with Drivers  Promise Array Management  PAM  utility  PAM User  Manual and FastTrak SX4030  SX4060  S150 SX4 M User Manual       FastTrak SX4030  SX4060  S150 SX4 M User Manual       If any of the items are missing or appear damaged  please contact your dealer or  distributor immediately     N K pr      Warning    The electronic components on the FastTrak RAID Controller card  are sensitive to damage from Electro Static Discharge  ESD    Observe appropriate precautions at all times when handling the  FastTrak card or its subassemblies        Warning       Before installing the adapter into an existing system  backup any  important or useful data  Failure to follow this accepted PC  practice could result in data loss        Important       In place of the 64 MB SDRAM DIMM included with the FastTrak  card  you can install a SDRAM DIMM of up to 256 MB for  additional capacity and performance  Promise provides a list of  approved DIMMS 
9.  40 235 2600  8 30 5 00pm The Netherlands Time       If you wish to write us for  support     Pacific Rim    E mail Support    Promise Technology Europe B V   Attn  Technical Support  Luchthavenweg 81 125   5657 EA Eindhoven  The Netherlands    support promise com tw       Fax Technical Support     886 3 564 53 13  Attention  Technical Support       Phone Technical Support     886 3 578 23 95  ext  8873   9 00 5 30pm Taiwan Time       If you wish to write us for  support        China       E mail Support    Promise Technology  Inc   Attn  Technical Support   2F  No  30  Industry E  Rd  IX  Science based Industrial Park  Hsinchu  Taiwan  R O C     support china promise com       Fax Technical Support     86 10 6872 3940  Attention  Technical Support       Phone Technical Support     86 10 6872 3941  9 00 6 00pm China Time       If you wish to write us for  support     Promise Technology China  Attn  Technical Support   Room 3213  No  11   South Zhong Guan Cun Street  Hai Dian District  Beijing 100081  P R  China       61    FastTrak SX4030  SX4060  S150 SX4 M User Manual       Limited Warranty    Promise Technology  Inc      Promise     warrants that for three  3  years from the  time of the delivery of the product to the original end user     a  the product will conform to Promise   s specifications     b  the product will be free from defects in material and workmanship under  normal use and service     This warranty     a  applies only to products which are new and in carto
10.  Insert the Promise Technology driver diskette into drive A  and press Enter   Choose WinXP Promise FastTrak S150 SX4 SX4000 Series from the list  that appears on screen  and then press the Enter  1  Press S to use the  driver on the floppy disk and then press Enter to continue with installation   The Windows XP Setup screen will appear again saying    Setup will load    support for the following mass storage devices     The list will include WinXP  Promise FastTrak S150 SX4 SX4000 Series     Note  If you need to specify any additional devices to be installed  do so at  this time  Once all devices are specified  continue to the next step     From the Windows Setup screen  press the Enter  Setup will now load all  device files and then continue the Windows XP installation     Note  Check the readme file  included with the downloaded driver files  for  instructions on installing the RAID Console        33    FastTrak SX4030  SX4060  S150 SX4 M User Manual       Install Driver in an Existing System    Important    If you plan to move the boot drive containing the existing Windows  Server 2003 operating system to the FastTrak card  you MUST  load the FastTrak driver to the boot drive while it is still attached to  your existing hard drive controller     Do not attach the boot drive to the FastTrak card before  completing this step     After installing the FastTrak card and rebooting your system  Windows setup will  show a Found New Hardware dialog box     1   2     2 2  D p Noo  
11.  Responsibilities    You are responsible for determining whether the product is appropriate for your  use and will interface with your equipment without malfunction or damage  You  are also responsible for backing up your data before installing any product and  for regularly backing up your data after installing the product  Promise is not liable  for any damage to equipment or data loss resulting from the use of any product     Return Product For Repair    If you suspect a product is not working properly  or if you have any questions  about your product  contact our Technical Support Staff through one of our  Technical Services  making sure to provide the following information     e Product model and serial number  required     Return shipping address     Daytime phone number     Description of the problem   e Copy of the original purchase invoice       63    FastTrak SX4030  SX4060  S150 SX4 M User Manual       The technician will assist you in determining whether the product requires repair   If the product needs repair  the Technical Support Department will issue an RMA   Return Merchandise Authorization  number     Return ONLY the specific product covered by the warranty  do not ship cables   manuals  diskettes  etc    with a copy of your proof of purchase to     USA and Canada  Promise Technology  Inc   Customer Service Dept   Attn   RMA    1745 McCandless Drive  Milpitas  CA 95035       Other Countries  Return the product to your dealer  or retailer     Contact them fo
12.  SX4030  SX4060  S150 SX4 M User Manual       SuSE Linux 8 1  8 2    Install Driver During New OS Installation  Single Processor    1  Insert the install CD into CD ROM drive     2  When the boot  picture prompts for an installation option  add the following  line to the input box  acpi oldboot     3  Press the left Alt key and insert the FastTrak driver diskette into the floppy  drive   4  Finish the installation normally     Note  Check the readme file  included with the downloaded driver files  for  instructions on installing the RAID Console     Install Driver During New OS Installation  Multi Processor    1  Setthe BIOS to boot from the CD ROM    2  Insert the install CD into CD ROM drive    3  When the boot  prompt appears on the bottom of the screen  type  acpi oldboot into the lower input box    4  Press the left Alt key and insert the FastTrak driver diskette into the floppy  drive   5  Finish the installation normally    Note  Check the readme file  included with the downloaded driver files  for   instructions on installing the RAID Console     Install Driver in an Existing System   1  Insert the FastTrak driver diskette into the floppy drive    2  Type the following commands     mount  dev fdO  media  floppy    cd  media  floppy    install    insmod FastTrak    umount  media  floppy   3  Remove the FastTrak driver diskette from the floppy drive     Note  Check the readme file  included with the downloaded driver files  for  instructions on installing the RAID Conso
13.  Stripes all Drives with Data and Parity Information     The capacity of a RAID 5 array is the smallest drive size multiplied by the total  number of drives  less minus one  Hence  a RAID 5 array with four 100 GB hard  drives will have a capacity of 300 GB  An array with two 120 GB hard drives and  one 100 GB hard drive will have a capacity of 200 GB        47    FastTrak SX4030  SX4060  S150 SX4 M User Manual       JBOD   Single Drive    An alternative to RAID  JBOD capacity is equal to the sum of all drives in the  group  even if the drives are of different sizes     JBOD appears in the User Interface as one or more individual drives     There are no performance or fault tolerance features  When one disk fails  all  data on that disk is lost  The other disks are unaffected        Disk Drive    Figure 5  JBOD manages drives Individually  unlike RAID        48    Chapter 6  Troubleshooting  amp  Tips      Motherboard Issues  below   Operating System Related Issues     System CMOS Issues  page 50 page 53     Drive Related Errors  page 50   Performance Tips  page 54    This section is used to assist with troubleshooting conflicts and FastTrak  SX4030  SX4060 or S150 SX4 M installation problems  Also refer to the  README TXT file on the FastTrak driver and utility diskette for more recent  information as well as the PromiseOnline services listed in Chapter 7     The section is divided into the following categories  Motherboard Issues  System  CMOS Issues  Drive Errors  Operating
14.  System Errors  and Audio Video Editing  Tips     Motherboard Issues  Freeing additional IRQ resources    Since the Promise card supports PCI Interrupt sharing  it is possible to use  IRQs already assigned to another PCI card  Interrupt Sharing is not  supported with onboard IDE controllers  If the onboard IDE controller s  are  not used  you may disable the controllers to free IRQ 14 and or 15     Configuring PCI IRQ resources    Setting the IRQ for a particular PCI slot will be different depending on the  motherboard BIOS  This setting is usually made in the PCI Configuration  and or Plug and Play  PnP  section of the motherboard BIOS setup  There  are three common methods that motherboard BIOS s handle assignment of  IRQs to PCI slots     e Specifically assigning an IRQ to a particular slot   You can tell the  motherboard to use IRQ 10 for PCI slot 1  IRQ 11 for PCI slot 2  etc     e Listing which IRQs are available to be assigned to the PCI slots     This  BIOS has an option where you specify 1st Available IRQ  2nd Available  IRQ  etc  The BIOS then scans the PCI slots for PCI cards and assigns  these IRQs in the order that it finds the PCI cards     e Excluding an IRQ from being used by a PCI slot     If you have an ISA  card that is using an IRQ  change the setting for this particular IRQ from  Available to Used by ISA card so that the motherboard will not assign  this IRQ to a PCI slot     Consult your motherboard manual for information that is specific to your  mother
15.  The capacity of the array will  equal the capacity of the smallest drive multiplied by the number of drives within  the array     Change Stripe Block Size    For RAID 0 arrays  the FastTrak Controller will allow you to change the stripe  block size  The default is 64K  However  certain application environments may  perform optimally with different block size  To change the block size  use the  Arrow keys to highlight the field and the Spacebar to cycle through the available    size selections  16  32 or 64K      Note    You cannot change the block size after the array has been  created        Assign Drives to a RAID 0 Array    Under the Drive Assignments section  highlight a drive and  with the Spacebar   change the Assignment option to Y to add the drive to the disk array  Press Ctrl Y  to save the disk array information  The initial Define Array Menu screen will  appear after you have pressed Ctrl Y  You will see the array defined  You may  select another Array number to define or you may ESC to exit and return to the  Main Menu of FastBuild     Set Gigabyte Boundary  For RAID 0 arrays  FastTrak sets the Gigabyte Boundary to OFF   Save Array Information    Press Ctrl Y to save the Disk Array Information        20    Chapter 3  FastBuild Utility       Create a RAID 1 Array    In the Define Array Definition Menu section  press the Spacebar to cycle through  array types and select RAID 1 for RAID Level  RAID 1 arrays use two disk drives   The capacity of the array will be hal
16.  Y to save the Disk Array Information        23    FastTrak SX4030  SX4060  S150 SX4 M User Manual       Hot Spare Drives    Any extra drive that is not assigned to an array will be recognized as a Spare  Drive  Such drives are designated Free in the View Drive Assignments screen   see below      FastBuild Array Utility 2 xx  c  2002 2005 Promise Technology  Inc       View Drive Assigments         Spare Drives are automatically added to an array once a disk member of the  array has been detected as failed  To restore fault tolerance as quickly as  possible  the FastTrak Controller performs an automatic data rebuild on the spare  drive in the background without the need to restart the system  At a later time  the  failed drive can be physically removed and an extra drive added in its place to  function as the spare drive     Partition and Format Array    Your new RAID array must be partitioned and formatted before use  Use the  same method of partitioning and formatting on an array as you would any other  fixed disk added to your computer system        24    Chapter 3  FastBuild Utility       Set Disk Array as Bootable    You may select which defined array will be used as the bootable array from the  Define Array Menu  press 2 in the Main Menu   Press the up and down arrow  keys to hHighlight the desired array and press the Spacebar  The system will now  recognize this as the first array and an asterisk     will appear next to the array  number indicating it as bootable  see b
17.  in the  array     RAID 5  Block and Parity Striping     For capacity     The FastTrak RAID 5 array is the smallest drive size  multiplied by the number of drives  less one  The larger HDDs will be  truncated  The truncated space on the bigger HDDs will then be unusable     For sustained data transfers     The FastTrak RAID 5 array will write data at  moderate speed but will read data very quickly  The fact that you can use 3  or 4 drives and the effect of parity calculations means defining speed in  terms of a single HDD is difficult and imprecise     JBOD  Just a Bunch of Disks     Technically  JBOD is not a RAID level but a collection of single disk drives   The FastTrak SX4030  SX4060 and 8150 SX4 M support up to four such  drives     Drive Issues    Can   add a drive to a FastTrak SX4030  SX4060 and S150 SX4 M array via  hot swap and dynamically adjust the array size configuration     No  The FastTrak Controller does not support dynamically adjustable RAID  size configurations     Do the HDDs on the FastTrak SX4030  SX4060 and S150 SX4 M have to be  the same size     The HDDs that you use with the FastTrak SX4030  SX4060 and S150 SX4   M do not have to be the same size  If the sizes differ  the FastTrak Controller  will truncate the bigger HDD so the drives match  The resulting difference in  HDD space is unusable  so avoid using HDDs of significantly different  capacities       already have an array on an older FastTrak controller  Can   move that  array to my new FastT
18.  or S150 SX4 M card    e Performance     RAID 0   e Fault Tolerance     RAID 1      Performance plus Fault Tolerance     RAID 0 1  RAID 5    FastBuild also supports Just a Bunch of Disks  JBOD  technology  JBOD allows  you to add up to four disk drives to your computer for expanded storage capacity   However  unlike RAID  JBOD drives function individually  thus there is no  performance increase nor any fault tolerance                           Fault No  of  RAID Level Performance   Tolerance Capacity Drives  RAID 0 Highest No No  Drives x 2 to 4   Stripe  Smallest Drive  RAID 1 Normal Yes Smallest Drive 2   Mirror   RAID 0 1 High Yes 2X Smallest 4   Stripe Mirror  Drive  RAID 5 High Yes Smallest Drive 3 or 4   Distributed x No  Drives  1  Parity   JBOD Normal No Sum of all 1 to4   Single Drive  Drives                      42       Chapter 5  Disk Array Concepts       About RAID Levels    RAID 0  Stripe     Reads and writes sectors of data interleaved between multiple drives  When any  disk member fails  it affects the entire array  Performance is better than a single  drive since the workload is balanced between the array members  This array type  is for high performance systems  Identical drives are recommended for  performance as well as data storage efficiency  The disk array data capacity is  equal to the number of drive members times the smallest member capacity  For  example  one 100 GB and three 120 GB drives will form a 400 GB  4 x 100 GB   disk array      4    Data S
19.  rich  secure  and versatile enterprise wide ATA RAID solution  In addition  the FastTrak 4060  and  150 SX4 M support RAID expansion  The resulting RAID environment  allows users and administrators to configure  manage  and monitor everything  from single arrays on local systems to array networks residing in offsite locations     The FastTrak 8150 SX4 M RAID Controller card supports Serial ATA hard drives   The FastTrak SX4030 and SX4060 RAID Controller cards support  Parallel  ATA  hard drives  At their core  all three FastTrak cards provide advanced RAID  management functions  creating arrays  monitoring them  keeping them online  and operating at optimum efficiency  FastTrak can also perform many other  tasks  such as       Create arrays at various RAID levels  0  1  0 1  5 and JBOD   depending on  the application being used   e  Setupa network of FastTrak RAID servers  all running under different RAID  levels  and monitor those servers from any workstation on the network    e Create a series of FastTrak RAID networks at any number of offsite locations    e Monitor and or repair FastTrak RAID arrays using the Internet from an offsite  location   all without compromising the integrity of secure servers    XOR Acceleration    The FastTrak S150 SX4 M  SX4030 and SX4060 Controllers have a Hardware  XOR accelerator  which offloads the parity calculation workload from the main  CPU and transfers it to the controller card  boosting the performance of the entire  system     Hot S
20.  s   backup any  existing data  Removal of the reserve sector of any drive  permanently deletes all existing data on the hard drive        For RAID 1 arrays  remove the Reserve Sector from the mirrored drive first   this will appear during Step 3 below  then rebuild the mirrored array   Remove the Sector on the Master Drive only as a last resort     For RAID 0 and RAID 5 arrays  removing the Reserve Sector from any of the  drives will destroy the arrayed data     For JBOD  removing the Reserve Sector from any of the drives will destroy  the data on that drive     To remove the Reserve Sector  follow these steps     During boot up  press Ctrl F to enter the FastBuild BIOS utility   2  Choose option 1  View Drive Assignments     3  Press arrow keys to highlight the drive where you wish to remove the  reserve sector     4  Press AIt F1  The following message will appear  Press Ctrl Y to delete  the data in the disk or press any key to abort  The highlighted drive will  start blinking on the screen     5  Press Ctrl TabY  The following message will appear  The Reserved  Sector was wiped  System will reboot when you exit this menu  Press  any key to continueA message will appear that says the reserved sector   which is where array information is kept  on the disk will be wiped  1   Press Y to confirm     6  Take the appropriate action     e For RAID 1 and RAID 5 arrays  repeat this process for each  member of the particular array that is having a problem  When you  are finished  p
21.  the device driver you want to install  click Next    If a warning about Windows Logo testing appears  click Continue Anyway   Under Completing the Found New Hardware Wizard  click Finish    If the New Hardware Wizard appears again  close it       Click Yes to restart your PC     Remove the Promise FastTrak Driver diskette     When the Found New Hardware Wizard appears a second time  select    Install the Software Automatically  Recommended  and click Next   If a warning about Windows Logo testing appears  click Continue Anyway   Under Completing the Found New Hardware Wizard  click Finish     Note  Check the readme file  included with the driver files  for instructions on  installing the RAID Console        31    FastTrak SX4030  SX4060  S150 SX4 M User Manual       Confirm Installation    de    ak U N    From the Windows Desktop  open the Control Panel from My Computer   Click on Performance and maintenance    Click on the System icon    Choose the Hardware tab  and then click the Device Manager button     Click the   in front of SCSI controllers  Windows 2003 Promise FastTrak  S150 SX4 SX4000 Series should appear        32    Chapter 4  Installing Software Drivers       Windows XP    Install Driver During New OS Installation    de    Start the installation  Boot from the CD ROM  Press F6 after the message     Press F6 if you need to install third party SCSI or RAID driver    appears   When the Windows Setup window is generated  press S to specify an  Additional Device s   
22.  their drive positions  This allows  drives to be placed on different FastTrak connectors or cards within the system  without reconfiguring or rebuilding     Disk Array Terms    Description    A disk array is formed from a group of two or more disk drives that appear to the  system as a single drive  The advantage of an array is to provide better  throughput performance and or data fault tolerance     Better performance is accomplished by sharing the workload among multiple  physical drives        41    FastTrak SX4030  SX4060  S150 SX4 M User Manual       Fault tolerance is achieved through data redundancy operation where if one  or  more  drive fails or has a sector failure  a mirrored copy of the data can be found  on another drive s      For optimal results  select identical Serial ATA drives  S150 SX4 M  or Ultra ATA  drives  SX4030   SX4060  to install in disk arrays  The matched performance of  the drives allows the array to function better as a single drive     Member    The individual disk drives in an array are called members  Each member of a  specific disk array has coded in its reserved sector configuration information that  identifies the drive as a member  All disk members in a formed disk array are  recognized as a single physical drive to the system     Types    For most installations  the FastBuild setup Auto Setup  1  option will configure  your system  There are four disk array types in three categories that can be  installed on the FastTrak SX4030  SX4060
23.  your OS as it is  Remember that some operating  systems have varying limits on the sizes of partitions and logical drives that  can be defined  Consult your OS documentation about partitioning larger  drives     What system BIOS setup settings do   use for the drives on the FastTrak   X4030  SX4060 and S150 SX4 M controller     None  The drives on the FastTrak Controller are supported by the FastTrak  BIOS and or OS drivers  not by your system BIOS        58    Chapter 7  Support       How do   partition format my FastTrak SX4030  SX4060 and S150 SX4 M  RAID array     The FastTrak Controller represents the array as a single HDD to your  System  Therefore  anything that you can do to a single HDD you can do to  a FastTrak array     For example  you should use the FDISK and FORMAT utilities to partition  and format the array  You can partition the array as you see fit  You can  format the array with any file system you wish     Installation Issues  Capacity  Booting     Why are some drives recognized by the FastTrak SX4030  SX4060 and S150  SX4 M Array Setup utilities with only partial capacity     Some hard drives ship with a jumper that reduces the addressable capacity  of the drive to prevent problems with older systems that don   t support larger  drives  Consult your hard drive documentation to set the jumper so that you  can use the full capacity of the drive     How can   change the system boot sequence in order to boot from the  FastTrak SX4030  SX4060 and  150 SX4 M a
24. Build utility cannot  rebuild the array  The array must be rebuilt from the last tape backup or other  device  The user should identify and replace the failed drives     For RAID levels 1 and 5  at least two or more drives in the array have failed     For a RAID 0 or JBOD array  at least one drive has failed        15    FastTrak SX4030  SX4060  S150 SX4 M User Manual       Main Menu    FastBuild Array Utility 2 2  c  2002 2005 Promise Technology  Inc              Note       This menu uses number keys 1 through 4 to select options  Many  of the subsequent menu windows require you to press arrow pad  keys in order to highlight options  Press the spacebar to cycle  through choices for the selected option  Press Enter  return  to  select a highlighted option  Press ESC  Escape  to exit the menu        Descriptions of each of the four options from the Main Menu screen  above   appear on the following pages        16    Chapter 3  FastBuild Utility       View Drive Assignments    Press 1 on the Main Menu screen  to see the View Drive Assignments screen   below   This screen does not allow modifications to any of the four fields   FastBuild Array Utility 2 xx  c  2002 2005 Promise Technology  Inc     View Drive Assignrents    SBAGATESTS80027AS  80630  SBAGATEST380023AS  80630    SERAGNIESLT3S0023AS 80630  SEAGMIEST380023A8S 80630            Keys Available    Note       Boctable Array   If  ue  H  Do   ESC  Exit Mob  Serial        Channel  ID     This field shows the FastTrak Contro
25. Erter  Select  Space  Change Boot Drive    Array No      The Array Number column displays all arrays  defined or undefined   addressable by the FastTrak Controller     RAID Level   This column indicates the RAID type applied to a particular array   Total Drv This column displays the number of drives configured for the array     Capacity  MB      This column shows the total capacity in MB  megabytes  for  each array     Status     This column displays the status information for each array  See page 14  for status definitions        18    Chapter 3  FastBuild Utility       Define Array Definition Menu    Selecting an Array from the Define Array Menu brings up the Define Array  Definition Menu screen  below   First  choose the RAID Level you want  In the  Define Array Definition Menu section  press the Spacebar to cycle through array  types     e  RAID 0  Striping    e  RAID 1  Mirroring    e RAID 0 1  Striping   Mirroring   e RAID 5  Data   Parity Striping   e JBOD  Single Drive     See the explanations on the following pages for more information about each  RAID Level and the options that come with them     FastBuild Array Utility 2 xx  c  2002 2005 Promise Technology  Inc       Define Array Definition Mena    Array Nb FAD Isel Thtal Drv Status  Array 1 FAD 5 3 Furncticral  Stripe Block  64 KB Initialize Array  N Gigabyte Panbry  N            Feys Available     1  tp  1  Down  Space  Chang Option ES  Exit  erly  Sxe    Gigabyte Boundary     The Gigabyte Boundary feature is des
26. Inc  or an experienced radio TV technician for  help     This device complies with Part 5 of the FCC Rules  Operation is subject to the  following conditions   1  This device may not cause harmful interference  and  2   this device must accept any interference received  including interference that    may cause undesired operation     Caution       Only digital device equipment CERTIFIED CLASS B should be  attached to this equipment and that must have shielded cables              FastTrak SX4030  SX4060  S150 SX4 M User Manual          Contents    Chapter 1  Introduction                                       1  About This Manual             0 00 OEE eee 1  Product Overview iasanen da Kamia VEREV AAA AO E Ea k 2  Promise Array Management Utility  PAM                        3   Chapter 2  Installation                                        5  Installing the FastTrak Card                                 7  Installing the Disk Drives                                    8   Chapter 3  FastBuild    Utility                                13  Setup Quick Reference                                    13   Setup Checklist                                       13  Common Tasks           0000 eee eee eee eee 13  Enter the FastBuild Utility                            14   Create anv ATAY ai eee Healy Baas Iva eg ee 14  DeleteanArray                                   14  FastTrak BIOS Reference                                  15  Main UA 16  View Drive Assignments                            
27. PROMISE  TECHNOLOGY  INC     FASTTRAK SX4030   SN4060  5730 SN4 M    USER MANUAL       FastTrak SX4030  SX4060  S150 SX4 M User Manual       Copyright     2004 Promise Technology  Inc  All Rights Reserved     Copyright by Promise Technology  Inc   Promise Technology   No part of this  manual may be reproduced or transmitted in any form without the expressed   written permission of Promise Technology     Trademarks    Promise  and the Promise logo are registered in U S  Patent and Trademark  Office  All other product names mentioned herein may be trademarks or  registered trademarks of their respective companies     Important data protection information    You should back up all data before installing any drive controller or storage  peripheral  Promise Technology is not responsible for any loss of data resulting  from the use  disuse or misuse of this or any other Promise Technology product     Notice    Although Promise Technology has attempted to ensure the accuracy of the  content of this manual  it is possible that this document may contain technical  inaccuracies  typographical  or other errors  Promise Technology assumes no  liability for any error in this publication  and for damages  whether direct  indirect   incidental  consequential or otherwise  that may result from such error  including   but not limited to loss of data or profits     Promise Technology provides this publication    as is    without warranty of any kind   either express or implied  including  but 
28. SX4030  SX4060  S150 SX4 M User Manual          viii    Chapter 1  Introduction          About This Manual  below  e Product Overview  page 2    Promise Array Management  page 3    Thank you for purchasing one of Promise Technology s FastTrak SX4030   SX4060 or S150 SX4 M RAID controllers     About This Manual    This User Manual describes how to setup  use and maintain the FastTrak RAID  controller  It also describes how to use the Promise Array Management  PAM   RAID management software     This manual includes a full table of contents  chapter task lists and numerous  cross references to help you find the specific information you are looking for     Also included are four levels of notices     Note       A Note provides helpful information such as hints or alternative  ways of doing a task        Important    An Important calls attention to an essential step or point required  to complete a task  Important items include things often missed     Caution       A Caution informs you of possible equipment damage or loss of  data and how to avoid them        Warning    A Warning notifies you of probable equipment damage or loss of  data  or the possibility of physical injury  and how to avoid them           FastTrak SX4030  SX4060  S150 SX4 M User Manual       Product Overview    FastTrak SX4030 and SX4060 are ATA RAID controllers  The FastTrak S150  SX4 is a Serial ATA RAID controller  When used with Promise Array  Management  PAM   the FastTrak RAID Controllers offer a feature
29. and a testing procedure to ensure compatibility   See Appendix A in this User Manual     Notes       The FastTrak SX4030  SX4060 and  150 SX4 M RAID Controller  cards are PCI Plug n Play  PnP  devices  No changes are  necessary in the motherboard CMOS BIOS Setup for resources or  drive types in most applications        Chapter 2  Installation       Installing the FastTrak Card    The FastTrak RAID Controller card fits into any available   e 32 bit PCI slot  must be PCI 2 2 compliant    e The 32 bit portion of a 64 bit PCI slot   on the PC s motherboard  see Figure 1 below      Remove the cover of your system     2  Remove the inside slot cover of an available 32 bit PCI slot on the  motherboard     Note  FastTrak SX4030 supports only a 33 MHz PCI slot     Ec  9  A De                                                                            3  Install the FastTrak card into the open slot  above   Secure the bracket to the  system s frame    4  Attach your system case s 2  or 4 pin LED cable to the LED connector on the  FastTrak card  see Figures 2 and 3  below   Make sure that pin 1 on the  connector is aligned with pin 1 of the cable     5  Fasten the FastTrak card bracket to the system case  see below         FastTrak SX4030  SX4060  S150 SX4 M User Manual       Installing the Disk Drives    Important       If you wish to include your current bootable Serial ATA drive using  the Windows operating system as part of a bootable Mirrored   RAID 1  array on your FastTrak card  d
30. annels on the FastTrak Controller card   Since each drive s array data identifies itself to the array  it is possible to reorder  the drives without modifying the array setup  This is valuable when adding drives   or during a rebuild        Chapter 3  FastBuild Utility       Delete Array    Press 3 on the Main Menu screen to display the Delete Array Menu  below      FastBuild Anay Ubility 2 2   2002 2005 Promise Technology  Ine   L    Nte       Boctahle  I1  U H  Don  s  Exit     De1  Delete       Caution       Deletion of an existing disk array could result in the loss of all data  from the hard drives of the affected array     Record all array information  including array type  disk members   and stripe block size  in case you wish to undo a deletion     Arrays may possibly be recovered after deletion by immediately    re defining the array with information identical to the original  configuration           To delete an array  highlight the Array you wish to delete and press the Del key     When the following message appears  below   press Ctrl Y to confirm yes to  continue array deletion     P  cC m cc maru sc Wa ER m    o  Ww E EIER es i ee  gt  ii    Press any other key to abort the deletion process        FastTrak SX4030  SX4060  S150 SX4 M User Manual       Controller Configuration    Press 4 on the Main Menu screen to display the Controller Configuration Options  screen  below      FastBuild  tm  Utility 2 xx  c  2002 2005 Promise Technology  Inc     Adapter Configura
31. array exceeds 64GB  Windows 2000     Due to a limitation with FDISK  the utility reports only the storage capacity  that exceeds 64GB  This is a cosmetic  not actual  limitation  Simply create a  single DOS drive partition  reboot  and then format the partition  The Format  command will recognize the total capacity of the partition accurately   Windows will now recognize the total capacity of your array     Unable to Partition or Format Array    There are two possible causes       The FastTrak Controller is the bootable device but the array is not set to  be bootable     e The Reserve Sector of one of the drives has become corrupt or bad    If the FastTrak Controller is the bootable device  make sure that the array is  set to be bootable    1  During boot up  press Ctrl F to enter the FastBuild BIOS utility    2  Choose option 2  Define Array     3  Press the Up and Down Arrow keys to highlight the array that you want  to boot from     4  Press the Spacebar to select   An   asterisk will appear next to the array number indicating it as bootable     The system will now recognize this array as the first array seen  The system  will then use this bootable array as the  fixed  boot C  drive        51    FastTrak SX4030  SX4060  S150 SX4 M User Manual       The Reserve Sector of one of the drives has become corrupt or bad   Removing the Reserve Sector will remedy any issue related directly to a Bad    Reserve Sector     Warning       Before removing the Reserve Sector of the drive
32. arty SCSI or RAID driver    appears   When the Windows Setup window is generated  press S to specify an  Additional Device s    Insert the Promise Technology driver diskette into drive A  and press Enter   Choose Win2000 Promise FastTrak S150 SX4 SX4000 Series from the list  that appears on screen  and then press the Enter    The Windows Setup screen will appear again saying  Setup will load support  for the following mass storage devices     The list will include Win2000  Promise FastTrak S150 SX4 SX4000 Series    Note  If you need to specify any additional devices to be installed  do so at  this time  Once all devices are specified  continue to the next step    From the Windows Setup screen  press the Enter  Setup will now load all  device files and then continue the Windows installation     Note  Check the readme file  included with the downloaded driver files  for  instructions on installing the RAID Console        35    FastTrak SX4030  SX4060  S150 SX4 M User Manual       Install Driver in an Existing System    Important    If you plan to move the boot drive containing the existing Windows  Server 2003 operating system to the FastTrak card  you MUST  load the FastTrak driver to the boot drive while it is still attached to  your existing hard drive controller     Do not attach the boot drive to the FastTrak card before  completing this step     After installing the FastTrak card and rebooting your system  Windows setup will  show a Found New Hardware dialog box     1   2
33. ay already be listing the controller under Other Devices instead   of the Hard disk controllers section  In Device Manager under Other Devices  to see if it lists a PCI Card or RAID Controller  If so  highlight this listing and  click on the Properties button then click on the Driver tab     Depending on your version of Windows  choose either Change Driver or  Update Driver  Follow the on screen prompts to complete installation of the  driver  If Windows asks if you want to test if the device can be removed  safely  click on CANCEL  Reboot the system to complete installation of the  driver        Inaccessible Boot Device    Message Appears During Floppyless  Installation of Windows    You did not press the F6 key at the appropriate time  Reboot the system  and  press the F6 key when the message Press F6 if you need to install third  party SCSI or RAID driver  appears        53    FastTrak SX4030  SX4060  S150 SX4 M User Manual          No Hard Drives Found    Message Appears During CD ROM Installation of  Windows    You did not press the F6 key at the appropriate time  Reboot the system   and press the F6 key when the message Press F6 if you need to install third    party SCSI or RAID driver appears     Performance Tips    Here are some tips that may optimize performance in a RAID 0 striped array   If you are using an audio video editing card  we also recommend reviewing  your card s documentation for additional information    Use a FastTrak array as D  or other non bootable 
34. board        49    FastTrak SX4030  SX4060  S150 SX4 M User Manual       System locks up during boot up or when Windows starts    There may be a possible IRQ conflict with an ISA card  Identify what IRQs  are used by ISA cards  enter the Motherboard PCI Setup  and reserve the  IRQ for use with ISA  PCI slots cannot share IRQs with ISA cards     Miscellaneous problems such as    e FastTrak BIOS does not appear during boot   e FastTrak driver does not load   e Slow data transfer rates   Move the FastTrak card to a different PCI slot   Intermittent data problems    Overclocking the PCI bus may cause the system to hang or data corruption   If you experience either of these problems and you are overclocking the PCI  bus  set the PCI bus back to its normal setting to see if this is causing the  errors     System CMOS Issues  Set Motherboard CMOS Boot sequence to boot to the FastTrak card    On some Motherboard BIOS  it is necessary to set the Boot sequence to  SCSI  A   C  since the Promise card is identified as a SCSI card     Motherboard CMOS displays C  or D  drive failure during startup  See the Drive Related Errors section   Using an Onboard IDE Card with FastTrak card    If an onboard IDE controller is installed with hard disks  enable support in the  Motherboard Standard CMOS Setup for the drives  Note that the onboard  IDE hard drives will then be the bootable hard disk unless the system BIOS  has a boot sequence setting with the option to specify booting to a different  de
35. can   obtain the latest FastTrak drivers     Download the latest drivers from the Promise Technology website at  www promise com     Contact Technical Support    Promise Technical Support provides several support options for Promise users to  access information and updates  We encourage you to use one of our electronic  services  which provide product information updates for the most efficient service  and support    If you decide to contact us  please have the following information available    e Product model and serial number   e BIOS and driver version numbers      Adescription of the problem   situation    e System configuration information  including  motherboard and CPU type   hard drive model s   ATA ATAPI drives  amp  devices  and other controllers     Technical Support Services       Promise Online    Web Site http   www promise com   technical documents  drivers  utilities  etc         North  amp  South America                E mail Support support promise com  Fax Technical Support  408  228 6401  Attention  Technical Support  Phone Technical Support  408  228 6402  7 30 5 30pm M F Pacific Standard Time  If you wish to write us for Promise Technology  Inc   support  Attn  Technical Support    1745 McCandless Drive  Milpitas  CA 95035  USA          60    Chapter 7  Support       Europe  Africa  Middle East    E mail Support    support promise nl       Fax Technical Support     31  0  40 256 9463  Attention  Technical Support       Phone Technical Support     31  0 
36. drive in a Striped Array  For Audio Video editing  keep the original system boot drive on the standard  IDE controller as C  drive  Partitioning software such as FDISK will see the  array as one physical drive  D  or later  This will prevent file fragmentation  and provide better accessibility to the array     Re Configure PCI Latency Setting    The PCI Latency setting appears in some Motherboard BIOS  The setting  governs how much time is allocated to service each PCI slot  Promise  recommends a value of 64  An optimal value will vary from system to    system        54    Chapter 7  Support    e Frequently Asked Questions  below  e Contact Technical Support  page 60    Limited Warranty  page 62     Return Product for Repair  page 63    Frequently Asked Questions    This section lists frequently asked questions involving pre installation  drive  issues  installation  and post installation     Pre Installation  Speed  Device Types  Capacity  Cabling   What kind of hard drives can   use for a FastTrak  150 SX4 M array     You can use any Serial ATA hard drive s  to create arrays on the FastTrak   150 SX4 M  Use matching drives for multiple drive arrays to maximize  capacity usage as well as performance     What kind of hard drives can   use for a FastTrak SX4030 SX4060 array     You can use any Ultra ATA 100  or Ultra ATA 33  hard drive s  to create  arrays on the FastTrak SX4030 SX4060  Use matching drives for multiple   drive arrays to maximize capacity usage as well as perfo
37. elow      FastBuild Anay Utility 2 2   c  2002 2005 Promise Technology  Inc     Define Array Meri       Keys Available         Note       Booctable Array   t  U H  Don ES  Exit Erter  Select  e  Chang Boot Drive    Important       You must reconfigure your PC   s or server   s BIOS in order use  FastTrak card as the bootable controller  The system will then use  the bootable array as the  fixed  boot C  drive           FastTrak SX4030  SX4060  S150 SX4 M User Manual       Disk Array Recognition Order    During computer startup  the disk arrays on the FastTrak Controller card are  recognized in this order       The bootable array  designated in the FastBuild setup   e Other arrays by their numbers  such as Array 1  Array 2         Array Recognition Order determines the order in which each array is assigned  the next available drive letter     By way of example  say that your PC boots from its internal disk drive and has a  CD ROM Drive  In addition  you have a FastTrak S150 TX4 with two arrays   Array1 and Array2  When your system boots  the internal disk drive will be C   the  CD ROM will be D   Array1 will be E  and Array2 will be F      Saved Disk Array Information    Note       Promise suggests that you record information about your disk  array s  for future reference        All disk array data is saved within the reserved sector of each arrayed drive   Another feature of the FastTrak disk array system is to recognize drive members  even if drives are moved to different ch
38. f that of the smaller drive in the array  No  stripe block size option is available when mirroring two drives     Create a Mirroring Array with Two New Drives    As described above  if you select a mirroring array and wish to use two new  drives  follow the directions here  Under the Drive Assignments section  assign  both new drives to the array and save the information by pressing Ctrl Y  Once  the process is complete  you will be returned to the Define Array Menu where the  array will be shown as defined     Note       You may choose to attach an unassigned third drive to the  FastTrak Controller to act as a hot spare replacement  see Page  26     Change the Stripe Block Size   For RAID 1 arrays  FastTrak does not permit you to change the Stripe Block size    Set Gigabyte Boundary    For RAID 1 arrays  FastTrak allows you to toggle the Gigabyte Boundary ON or  OFF  The default is OFF  To toggle Gigabyte Boundary  use the Arrow keys to  highlight the field and the Spacebar to toggle between ON and OFF     Save Array Information    Press Ctrl Y to save the Disk Array Information        21    FastTrak SX4030  SX4060  S150 SX4 M User Manual       Create a RAID 0 1 Array  You must assign four drives to an array before this feature becomes available     Assign Drives to a RAID 0 1 Array    Under the Drive Assignments section  highlight a drive and  with the Spacebar  bar  change the Assignment option to Y to add the drive to the disk array   Continue to add drives to the array u
39. igned for fault  tolerant arrays  RAID 1  0 1 and 5  in which a drive has failed and the user  cannot replace the drive with the same capacity or larger  Instead  the Gigabyte  Boundary feature permits the installation of a replacement drive that is slightly  smaller  within 1 gigabyte  than the remaining working drive  for example  an  80 5 GB drive would be rounded down to 80 GB   This can be helpful in the event  that a drive fails and an exact replacement model is no longer available           For the Gigabyte Boundary feature to work  the Gigabyte Boundary feature must  be set to ON when the original array is created  When enabled  the Gigabyte  Boundary feature rounds the drive capacity of all drives to the common whole GB  drive size  For example  with the Gigabyte Boundary feature enabled  the  remaining working drives can be 80 5 GB and the replacement drive can be 80 3   since all are rounded down to 80GB  This permits the smaller drive to be used   Please note that users will lose a small amount of available storage capacity from  each drive in order to arrive at a common drive size        19    FastTrak SX4030  SX4060  S150 SX4 M User Manual       Create a RAID 0 Array    In the Define Array Definition Menu section  see Figure 8   press the Spacebar to  cycle through array types and select RAID 0 for RAID Level  Assign from one to  four drives to this array  Each member of such an array will no longer be readable  as an independent drive if removed from the array 
40. ins       Ifthe DIMM is OK  the program will show a PASS message similar to  the one below     Promise Memory Test Utility V1 3 01 24 2004 18 07 50    Controller Type                 FastTrak 4060  Memory Speed                 LOOMHz  Memory Size                  128MB  Memory Type                  Non ECC  Memory Test Result   HOST         PASS  Memory Test Result   HDMA            PASS  Memory Test Result   XOR          PASS    The PASS message means you can use the DIMM that is currently  installed     e   fthere is any error  the program will stop and return to DOS and show  error message  Do not use the DIMM    e Ifthe program halts for more than 20 seconds  there may be an error   Check the FastTrak card  DIMM  and your system BIOS  Then run the  test again        66    
41. ith their arrays     FastTrak SX4030  SX4060 and S150 SX4 M implement five RAID levels as  follows     RAID 0  Stripe     For capacity     The FastTrak RAID 0 array will be as big as the smallest HDD  in the array times however many HDDs are in the array  Any larger HDDs  will simply be truncated  The truncated space on the bigger HDDs will then  be unusable     For sustained data transfers     Using a FastTrak Controller  a RAID 0 array  consisting of two HDDs will transfer at about twice the speed of the slowest  HDD in the array  A RAID 0 array consisting of four HDDs will transfer at  about three times the speed of the slowest HDD in the array     RAID 1  Mirror     For capacity     The FastTrak RAID 1 array will be as big as the smallest HDD  in the array  The larger HDD will simply be truncated  The truncated space  on the bigger HDD will then be unusable     For sustained data transfers     The FastTrak RAID 1 array will write data at  the rate of the slowest HDD in the array  The FastTrak array will read data at  twice the rate of the slowest HDD in the array     RAID 0 1  Stripe Mirror     For capacity     The FastTrak RAID 0 1 array will be one half the size of the  smallest HDD in the array  The larger HDDs will be truncated  The truncated  space on the bigger HDDs will then be unusable        56    Chapter 7  Support       For sustained data transfers     The FastTrak RAID 0 1 array consisting of  four HDDs will transfer at about twice the speed of the slowest HDD
42. ive  You can attach a  third drive to the FastTrak SX4030  SX4060 or 8150 SX4 M card without  assigning it to the array  Such a drive will be activated to replace a failed drive  that is part of a mirrored array  A rebuild takes place automatically in the  background to mirror the good drive data on to the spare  At a later time  the  system can be powered off and the failed drive can be physically removed and  replaced  Spare drives must be the same or larger capacity than the smallest  array member        44    Chapter 5  Disk Array Concepts       RAID 0 1  Stripe Mirror     A combination of RAID 0 and RAID 1 arrays  It can increase performance by  reading and writing data in parallel while protecting data with duplication  A  minimum of four drives are required     With a four drive disk array  two pairs of drives are striped  Each pair mirrors the  data on the other pair of striped drives  The data capacity is similar to a standard  Mirroring array with half of total capacity dedicated for redundancy     Data Stripe     p             Data  Mirror       Disk Drives    Figure 3  RAID 0 1 starts with a two drive Striped array copies it onto two  additional drives to make a Mirror       45    FastTrak SX4030  SX4060  S150 SX4 M User Manual       About Dual Data Redundancy    One unique  though rarely occurring  feature of RAID 0 1 is dual fault tolerance   In some cases  two drives can fail simultaneously and still maintain the integrity  of data  There are six combinations i
43. k SID SM ny ELSE 1102  o 200382555 Bomise Erimnolany  Te All rigts tesenei    Theta ON Sia GI MB    Nb Array is frel    Bess  lt 1 toeta uhu    n  Unite     Bess  lt  gt  toari mekbhni ia           2  Press the Ctrl F keys to display the FastBuild Utility Main Menu  below      FastBuild Array Utility 2 2   c  2002 2005 Promise Technology  Inc                 10    Chapter 2  Installation       3  Press 2 on the Main Menu screen to display  the Define Array Menu appears   below      FastBuild Aray Utility 2 20  c  2002 2005 Promise Techrology  In     Define Anay Men     RAID Isel Total Drv Capacity  VB        4  Press the arrow keys to highlight an array number you wish to define and  press Enter to select it  The Define Array Definition Menu will next appear   below         FastBuild Array Utility 2 30   c  2002 2005 Promise Technology  Inc             Keys Available     t  U  1  Down  Scece  Chang Cpticen ES  Eit  r r  Sxe       5  Choose the RAID Level you want  In the Define Array Definition Menu  section  press the Spacebar to cycle through array types     RAID 0  Stripe    RAID 1  Mirror    RAID 0 1  Stripe   Mirror   RAID 5  Data   Parity Stripe   JBOD  Single Drive     6  Press the arrow keys to move to the next option  Option choices depend on  the RAID Level you selected     Initialize Array  zero the disk drives  RAID 5 only   Stripe Block Size  the default 64KB is best for most applications   Gigabyte Boundary  allows use of slightly smaller replacement drives     
44. le                              25  Disk Array Recognition Order                            26  Saved Disk Array Information                           26  Delete Array    o d toad vanae Qoa ig dita EpI Cb bee dius 27  Controller Configuration                                   28  Chapter 4  Installing Software Drivers                          29  Windows Server 2003  Install Driver During New OS Installation                   30  Install Driver in an Existing System                        31  Confirm Installation             llle 32  Windows XP  Install Driver During New OS Installation                   33  Install Driver in an Existing System                        34  Confirm Installation             llle 34  Windows 2000  Install Driver During New OS Installation                   35  Install Driver in an Existing System                        36  Confirm Installation             llle 36  Red Hat Linux 8 0  9 0  Install Driver During New OS Installation                   37  Install Driver in an Existing System                        37  SuSE Linux 8 1  8 2  Install Driver During New OS Installation                   38  Install Driver in an Existing System                        38  Promise RAID Utility for Linux                               40       vi    Contents       Chapter 5  Disk ArrayConcepts                              41  About  FastIrak    x aman dane ae eate Mem toe ada ee males 41  About Adapter BIOS                                   41  Reserve Sector    
45. le        38    Chapter 4  Installing Software Drivers       Promise RAID Utility for Linux    To install the utility  type the following commands     mount  dev fdO  mnt  Imnt install util  umount  mnt    To use the utility  type the following commands     cd  usr local promise    sxcslapp       39    Chapter 5  Disk Array Concepts      About FastTrak  below    Disk Array Terms  below  e About RAID Levels  page 43    About FastTrak    FastTrak SX4030  SX4060 and S150 SX4 M are high performance RAID  Controller cards that feature concurrent data channel operation and onboard  BIOS  The channels on the FastTrak card support concurrent operation that  allows for overlapped I O under multi tasking operating systems and sharing the  workload between multiple drives     About Adapter BIOS    The FastTrak card contains a BIOS code that extends the standard disk service  routine provided through Int13  The BIOS is bootable for DOS and other  operating systems that rely on the system BIOS for drive operation  When the  FastTrak BIOS appears during bootup  press Ctrl F to enter the FastBuild setup  to select from menu settings     Reserve Sector    Array configuration data about the drive member and other members in the disk  array are saved on a special location on the disk drives called the reserve sector   If any member of the array becomes corrupt or lost  the redundant configuration  data on the other members can be used for rebuilds     Disk array members do not have a memory of
46. ll join the assigned drives together and split  or stripe  data among  them  Each member of such an array will no longer be readable as an  independent drive if removed from the array     The capacity of the array will equal the capacity of the smallest drive multiplied by  one less than the total number of drives assigned to the array     Note    If you choose to use three drives  an additional unassigned drive  can be your hot spare drive in case of drive failure  see below      Change Stripe Block Size for RAID 5 Array    For RAID 5 arrays  the FastTrak Controller allows you to change the stripe block  size  The default is 64K  To change the block size  press the Arrow keys to  highlight the field and the Spacebar to cycle through the available size selections     Assign Drives to a RAID 5 Array    Under the Drive Assignments section  highlight a drive  and  press the Spacebar  to change the Assignment option to Y to add the drive to the disk array  Press  Ctrl Y to save the disk array information  The initial Define Array Menu screen will  appear after you have pressed Ctrl Y  You will see the array defined  You may  ESC to exit and return to the Main Menu of FastBuild     Set Gigabyte Boundary    For RAID 5 arrays  the FastTrak Controller allows you to toggle the Gigabyte  Boundary ON or OFF  The default is OFF  To toggle Gigabyte Boundary  press  the Arrow keys to highlight the field and the Spacebar to toggle between ON and  OFF     Save Array Information    Press Ctrl
47. ller channel ID  1 4  to which  a particular drive is attached     Drive Model   This field identifies the manufacturer  model  and model number  if  applicable  of each drive installed on the FastTrak Controller card     Capacity  MB    This field reflects the capacity in MB  megabytes  of each drive   Assignment   This field identifies the array to which each drive belongs   Assigned drives are labeled with their disk array  1  2  3  etc       Unassigned drives are labeled free and are considered hot spares to provide  fault tolerance  Unassigned drives may also be used to create a new array at  any time     Mode     On the FastTrak S150 SX4  this channel uses Serial ATA technology and  displays a letter S  It does not apply to the FastTrak SX4030   SX4060        17    FastTrak SX4030  SX4060  S150 SX4 M User Manual       Define Array    Press 2 on the Main Menu screen to display  the Define Array Menu  see below    This screen displays any existing arrays  Users commonly create one or two  arrays with FastTrak SX4030  SX4060 or S150 SX4 M     To manually create arrays from the Define Array Menu  below   press the arrow  keys to highlight an array number you wish to define  and press Enter to select it   The Define Array Definition Menu will next appear that allows drive assignments  to the disk array  see below      FastBuild Array Utility 2 2  c  2002 2005 Promise Technology  Inc     Define Anay Meri          Keys Available    Nte       Bootable Array  tlt H  Don  Es Eit 
48. n which two drives can fail  The FastTrak  SX4030  SX4060 or S150 SX4 M card protects the data array in four of those  cases  Assume the drives are configured as follows       CHindicates channels on the FastTrak Controller card      AIB indicates which striped pair the drive belongs to        1 2indicates which part of stripe data        CH1 CH2 CH3 CH4  Drive A1 Drive A2 Drive B1 Drive B2                         Under RAID 0 1  the array maintains data integrity if any 1  2 combination                      survives   Failed Array  Event Dives Status Why   1 A1 A2 Functional B1 B2 retain array integrity  2 B1 B2 Functional A1 A2 retain array integrity  3 A1 B2 Functional B1 A2 retain array integrity  4 B1 A2 Functional A1 B2 retain array integrity  5 A1 B1 Offline B2 A2 contain only half the array data  6 B2 A2 Offline A1 B1 contain only half the array data                      46       Chapter 5  Disk Array Concepts       RAID 5  Block and Parity Striping     RAID 5 calculates parity in order to achieve redundancy rather than writing a  second copy of the data  like RAID 1  Parity is distributed across the physical  drives along with the data blocks  In each case  the parity data is stored ona  different disk than its corresponding data block  RAID 5 makes efficient use of  hard drives and is the most versatile RAID Level  It works well for file  database   application and web servers     Distributed Parity    Data it  Blocks TEM   r  r  r    Disk Drives    Figure 4  RAID 5
49. ner  appear on the screen  Once the BIOS identifies the arrays attached to the  FastTrak Controller card  it will offer an option to enter the FastBuild utility     Press Ctrl F to enter FastBuild utility and display the Main Menu  see page 16      Create an Array    1   2     In the Main Menu press 2 to display the Define Array screen  see page 18      In the Define Array screen  select the array number you want to define using  the arrow keys  and press Enter to display the Define Array Definition Menu  screen     In the Define Array Definition menu  see page 19   highlight the RAID Level  column using the Tab key  and then cycle through the choices using the  Spacebar to select the RAID level you wish to use for the new array     In the Drive Assignments menu  see page 17   press the Down Arrow to  select from the available drives to assign them as members of the new array   Use the Spacebar to toggle between Yes or No or press Y under the  Assignment column to assign the drive  N un assigns the drive     When you are finished assigning drives as array members  press the Ctrl Y  keys to save the array member assignment  The utility will return to the  Define Array Definition Menu screen and the new array will now be visible in  the list     Delete an Array    1     From the Main Menu press 3 to display the Delete Array Menu  see   page 27     In the Delete Array Menu  press the Up and Down Arrow keys to highlight  the array you wish to delete then press the Del key     Pre
50. not limited to implied warranties of  merchantability or fitness for a particular purpose     The published information in the manual is subject to change without notice   Promise Technology reserves the right to make changes in the product design   layout  and driver revisions without notification to its users     This version of the User Manual supersedes all previous versions        Notices       Radio Frequency Interference Statement    This equipment has been tested and found to comply with the limits for a Class B  digital device  pursuant to Part 15 of the FCC Rules  These limits are designed to  provide reasonable protection against harmful interference in a residential  installation  This equipment generates  uses and can radiate radio frequency  energy  and  if not installed and used in accordance with the instruction may  cause harmful interference to radio communications  However  there is no  guarantee that interference will not occur in a particular installation  If this  equipment does cause harmful interference to radio or television reception  which  can be determined by turning the equipment off and on  the user is encouraged  to try to correct the interference by one or more of the following measures        Reorient or relocate the receiving antenna         ncrease the separation between the equipment and receiver     e Connect the equipment into an outlet on a circuit different from that to which  the receiver is connected    e Consult Promise Technology  
51. ns on the date of  purchase     b  is not transferable     C  is valid only when accompanied by a copy of the original purchase  invoice     d  Is not valid on spare parts  fans  and power supplies    This warranty shall not apply to defects resulting from     a  improper or inadequate maintenance  or unauthorized modification s    performed by the end user     b  operation outside the environmental specifications for the product     C  accident  misuse  negligence  misapplication  abuse  natural or  personal disaster  or maintenance by anyone other than a Promise or a  Promise authorized service center     Disclaimer of other warranties    This warranty covers only parts and labor  and excludes coverage on software  items as expressly set above     Except as expressly set forth above  Promise DISCLAIMS any warranties   expressed or implied  by statute or otherwise  regarding the product  including   without limitation  any warranties for fitness for any purpose  quality   merchantability  non infringement  or otherwise  Promise makes no warranty or  representation concerning the suitability of any product for use with any other  item  You assume full responsibility for selecting products and for ensuring that  the products selected are compatible and appropriate for use with other goods  with which they will be used     Promise DOES NOT WARRANT that any product is free from errors or that it will  interface without problems with your computer system  It is your responsibilit
52. ntil you assigned all four drives  Press Ctrl Y  to save the disk array informationthe up arrow to move to RAID Mode     Define the Array as a RAID 0 1    In the Define Array Definition Menu section  press the Spacebar to cycle through  array types and select RAID 0 1 for RAID Level  You will be creating two pairs of  striped drives with identical data on them  The capacity of the array will be half  that of the total number of mirrored drives within the array     Save the information with Ctrl Y  FastBuild automatically creates the RAID 0 1  array and returns you to the Define Array Menu where the array will be shown     Change the Stripe Block Size    For RAID 0 1 arrays  FastTrak allows you to change the stripe block size  The  default is 64K  Press the Arrow keys to highlight the field and the Spacebar to  cycle through the available size selections  16  32  or 64K      Set Gigabyte Boundary    For RAID 0 1 arrays  FastTrak allows you to toggle the Gigabyte Boundary ON  or OFF  The default is ONOFF  To toggle Gigabyte Boundary  press the Arrow  keys to highlight the field and the Spacebar to toggle between ON and OFF     Save Array Information    Press Ctrl Y to save the Disk Array Information        22    Chapter 3  FastBuild Utility       Create a RAID 5 Array    In the Define Array Definition Menu section  press the Spacebar to cycle through  array types and select RAID 5 for RAID Mode  You must configure such an array  using a minimum of three drives     Your array wi
53. o NOT connect the hard  drive to the FastTrak yet  You MUST install the Windows driver  software first onto this drive while it is still attached to your existing  hard drive controller        The FastTrak  150 SX4 RAID Controller card supports only Serial ATA hard  drives  The FastTrak SX4030 and SX4060 RAID Controller cards support only   Parallel  ATA disk drives  For optimal performance  install disk drives of the  same model and capacity  The drives  matched performance allows the array to  function better as a single drive     If you are striping  RAID O  for performance  use up to four new drives  If  mirroring  RAID 1  for protection  you can use two new drives OR use an existing  drive and a new drive  the new drive must be the same size or larger than the  existing drive   If you are planning a RAID 5 array  use three or four new drives     1  SX4030  SX4060 only  Set your hard drives to Master  Cable Select or  Single  depending on drive specification   The Serial ATA Specification  excludes Master Slave settings  so these do not apply to the S150 SX4 card     2  Install the hard drives into the hard drive bays of your system     Caution    Use of removable hard drive enclosures other than Promise  Technology s SuperSwap is not supported and may result in  performance loss or other undesired results           Chapter 2  Installation       Ch1 Ch2 Ch3 Ch4 Buzzer 12C Connector LED Pins                                                                                   
54. oes provide a test to ensure that your DIMM will function reliably in  your FastTrak card     Testing is necessary because an incompatible DIMM can appear to work  properly  only to later experience unexpected errors that can result in data loss or  controller malfunction     Warning  The electronic components on the FastTrak RAID Controller card    h are sensitive to damage from Electro Static Discharge  ESD         Observe appropriate precautions at all times when handling the  FastTrak card or its subassemblies     DIMM Selection    Promise maintains a list of DIMMs that are known to work well with FastTrak  Use  this list as a guide when buying your DIMM  Go to  www promise com support   to view or download the list     DIMM Testing    Promise recommends testing for all DIMMs being used in a FastTrak controller   including those from its currently approved list  Follow this procedure to verify  your DIMM   s compatibility with your FastTrak RAID Controller card    1  Prepare a DOS Boot diskette    2  Copy the Promise Test Utility files to a second diskette     3  Install your SDRAM DIMM into the Cache Memory socket of the FastTrak  card     4  Plug in FastTrak card into a PCI slot on a desktop PC or server   5  Bootthe PC with the DOS Boot diskette     6  Remove the DOS Boot diskette and insert the diskette with the Promise Test  Utility files        65    FastTrak SX4030  SX4060  S150 SX4 M User Manual       7  Atthe DOS prompt  type memtest and press Enter  The test beg
55. r instructions  before shipping the product     You must follow the packaging guidelines for returning products    e Use the original shipping carton and packaging   e   nclude a summary of the product s problem s    e Write an attention line on the box with the RMA number   e     Include a copy of proof of purchase   You are responsible for the cost of insurance and shipment of the product to    Promise  Note that damage incurred due to improper transport or packaging is  not covered under the Limited Warranty     When repairing returned product s   Promise may replace defective parts with  new or reconditioned parts  or replace the entire unit with a new or reconditioned  unit  In the event of a replacement  the replacement unit will be under warranty  for the remainder of the original warranty term from purchase date  or 30 days   whichever is longer     Promise will pay for standard return shipping charges only  You will be required to  pay for any additional shipping options  such as express shipping         64    Appendix A  Memory Upgrade Test    A Dual Inline Memory Module  DIMM  for Synchronous Dynamic Random  Access Memory  SDRAM  providing 64 MB of cache memory is included with the  FastTrak RAID Controller card  Promise has already tested and verified the  DIMM included with the FastTrak card     You can upgrade to a SDRAM DIMM of up to 256 MB for additional capacity and  performance  Promise Technology does not sell larger DIMMs for FastTrak cards   But Promise d
56. rak SX4030  SX4060 and S150 SX4 M controller     Yes  All FastTrak controllers read the arrays the same way and can be  moved from one controller to another        57    FastTrak SX4030  SX4060  S150 SX4 M User Manual       Can   take a drive used in a FastTrak SX4030  SX4060 and S150 SX4 M array  and access it directly with a different controller  such as the one integrated  on the motherboard     Yes  but only under certain configurations  First  the other controller must  address the drives as LBA  not CHS     Second  only the following configurations allow the drive s  to be accessed  individually on another controller       Single drive RAID 0  stripe      One drive from a RAID 1  mirror  array   e JBOD    Other array configurations will not work for this purpose     If   have a problem with one of the drives on the FastTrak SX4030  SX4060  and  150 SX4 M  how can I low level format it to correct the problem     Do NOT do this  Low level formatting hard disk drives is not only  unnecessary but it generally does not correct problems commonly  experienced during use     Errors such as bad sectors or ECC CRC failure are best remedied by  completely replacing the drive  For this reason  do NOT low level format the  drives attached to the FastTrak Controller     Do I have to install disk management software on my array in order to  access the full storage capacity of drives     No  Disk management software will only complicate things  The array should  be fully addressable by
57. ress the Esc key twice to reboot      For RAID 1 arrays  hit the Esc key twice to reboot    7  After rebooting  use FastBuild to re create the array     e For striped arrays  use FDISK and FORMAT after setting up the  array    e For mirrored arrays  rebuild the mirrored array       Chapter 6  Troubleshooting  amp  Tips       Array Constantly Goes Into Critical or Offline Mode During Reboot  See Unable to Partition or Format array  above    Cannot Rebuild Mirrored  RAID 1  Array  See Unable to Partition or Format array  above     Fatal Errors or Data Corruption Are Constantly Reported When Reading or  Writing to Drive Array    See Unable to Partition or Format array  above     Operating System Related Issues    The Operating System no longer boots after creating a Mirrored Array using  your existing boot drive using Windows 2000 XP 2003 Server    This is due to Drive Geometry issues  You can verify this if you move the  original drive back to the onboard controller and it boots successfully  Each  controller can view a drive differently  This can be an issue for a new  controller that loads the original Master Boot Record  MBR  and then has a  problem translating it or the Operating System boot record     For Windows 2000  XP and 2003 Server  Promise recommends a clean  install of the Operating System  This action restores the MBR and OS boot  record  This requires repartitioning and formatting the drive     Promise Windows driver does not appear in Device Manager    Windows m
58. rmance     You can use Ultra ATA 133 drives but their data throughput will be at the  Ultra ATA 100 rate     Will ACPI work with HDDs on the FastTrak SX4030  SX4060 and S150 SX4   M     Yes  The FastTrak Controller supports ACPI S1  S3 and S4 standby modes   Can   use ATAPI devices on the FastTrak SX4030  SX4060 and S150 SX4 M   No  This FastTrak Controller does not support ATAPI devices     Will the FastTrak SX4030  SX4060 and S150 SX4 M work with 66MHz PCI  bus speed     FastTrak SX4060 and 8150 SX4 M work with a 66MHz or 33MHz PCI bus   FastTrak SX4030 works with a 33MHz PCI bus only        55    FastTrak SX4030  SX4060  S150 SX4 M User Manual       How can   change the resources that the FastTrak uses     The FastTrak SX4030  SX4060 and S150 SX4 M are fully PnP  This means  all the resources that it uses are given to it by the PnP BIOS on the  motherboard     The FastTrak Controller supports IRQ sharing  but this feature only works  when ALL the concerned devices support it  If your motherboard allows you  to control the assignment of these resources  you may be able to remedy the  problem by       Changing the IRQ assignments to the PCI slots in the motherboard  BIOS during boot up     e  Resetthe configuration data in your CMOS  This is usually an option in  the PnP section of your CMOS       Otherwise  switch the FastTrak Controller card to a different PCI slot     How do the FastTrak SX4030  SX4060 and S150 SX4 M RAID Controllers  provide storage and data protection w
59. rray     The boot sequence is controlled by the system BIOS  As far as the system  BIOS is concerned  the FastTrak Controller and defined arrays are  categorized as a SCSI device  This allows you to set the boot sequence in  your BIOS setup utility to boot from SCSI first  rather than IDE     If there are multiple SCSI add in controllers in the system  then the boot  sequence among them will be determined exclusively by their PCI slot  priority  PCI slot  1 will be first  slot  2 second  etc  Put the FastTrak  Controller in the PCI slot where it will be accessed ahead of other SCSI  controllers if you want to boot from the array     How can I change the boot sequence between a PCI SCSI card and the  FastTrak SX4030  SX4060 and  150 SX4 M RAID array     Since all PCI devices are PnP  it is difficult to determine which device is  addressed first  Some newer motherboard BlOSes have advanced options  that identify devices and allow you to select which device will be assigned  resources first  Otherwise you may have to physically switch the device  cards on the PCI slots so that the boot device is in the highest priority slot  number  see previous question         59    FastTrak SX4030  SX4060  S150 SX4 M User Manual       Post Installation    Why can   t   see the drives on the FastTrak SX4030  SX4060 and S150 SX4 M  under FDISK     You have not created an array yet  If no array has been created  the system  will not recognize drive s  attached to the FastTrak Controller     How 
60. sk  The second half  of this chapter is a visual and technical description reference including software  screen shots     Setup Quick Reference    Use this reference to make sure you have completed all the tasks necessary to  get your FastTrak SX4030  SX4060 or 8150 SX4 M server running  See Chapter  5 for more information on RAID arrays     Setup Checklist   V   Power up the system and watch for the Promise FastTrak BIOS messages    V when prompted  press Ctrl F to enter the FastBuild utility      V   if you are defining more than one array and booting from one of these  arrays  go to the Define Array menu  Press the Up and Down Arrow keys to  highlight the array then press the Spacebar to make it bootable      V   Restart the system for the changes to take effect   M    Watch for the Promise FastTrak BIOS messages  ensuring that the  messages reflect the array s  you have created     Common Tasks    The following is a listing of steps necessary to complete each type of task  required for setting up the FastTrak SX4030  SX4060 or S150 SX4 M system  through the FastBuild BIOS utility  The tasks are not intended to be a complete   step by step guide to setting up the FastTrak system successfully        13    FastTrak SX4030  SX4060  S150 SX4 M User Manual       Note       There are some advanced RAID array configuration options that  require the PAM utility to set up        Enter the FastBuild Utility    When the system boots  you will see the Promise FastTrak BIOS sign on ban
61. ss the Ctrl Y keys to confirm deletion        Chapter 3  FastBuild Utility       FastTrak BIOS Reference    When the FastTrak BIOS loads during bootup  it displays pertinent information  about the RAID arrays that it finds  Then  it displays Press Ctrl F to allow you to  enter the Array BIOS Configuration Utility  below      Eak SID SM ny ELSE LOD  o 2003 24555 Bomise Bhadan  dr All rigts menel    malaini AN    Nb Array is frel      Bess  lt Q toeta FARK t   undue   Bess  lt  gt  to arto bers            Shown is the first time BIOS Startup for FastTrak S150 SX4 M  The SX4030    SX4060 is similar  The information displayed in the form of a small table contains  the following properties     ID     These represent a unique ID number assigned to each RAID array identified  by the BIOS     Mode   This identifies the RAID mode configuration that the array is defined as   Size     This is the MB  Megabyte  data size of the indicated array     Track Mapping   This is the CHS  Cylinder Head Sector  equivalent of the array  geometry as hosted by the FastTrak BIOS int 13h disk services     Status     Shows one of three possible array status conditions   Functional     The array is fully operational  and no problems are present     Critical     The array is operational  but has lost its fault tolerance  For RAID  array levels 1  0 1 and 5 the array contains a failed drive  The user must  identify and replace the failed drive     Offline     The array is no longer operational and the Fast
62. tion Options      No Parameters Defined for Current Disk s          System Resources Configuraticn      Installed Memory Address   DE100000 Size  512M  Controller IRQ  11    ATA IO Adiress  9000   XR and HMA IO Acttress  9400  Sequence Control IO Adiress  9800  Flash and SRAM Memory Address  DEO00000       The information in the System Resources Configuration section is for display  only  Two items may be useful to the user for troubleshooting  The information presented here is as follows    Installed Memory      Shows the size of the SDRAM DIMM plugged into the FastTrak Controller  card     e Controller IRQ used by the FastTrak card    The other items may be useful if you ever have to contact Technical Support        28    Chapter 4  Installing Software Drivers    Following are driver installation procedures for the FastTrak SX4030  SX4060 or   150 SX4 M RAID Controller cards  Download the latest drivers from the  Promise Technology website at www promise com     Procedure Page Number  Windows Server 2003   Install Driver During New OS Installation                            30  Install Driver in an Existing System                                 31  Confirm Installation sisene nin tte 32  Windows XP   Install Driver During New OS Installation                            33  Install Driver in an Existing System                                 34  Confirm Installation                                             34  Windows 2000   Install Driver During New OS Installation      
63. tion screen  a prompt labeled  boot  will appear at the bottom of the screen  Type linux dd and press Enter     3  When the Installer asks  Do you have a driver disk  click Yes     4  Atthe  nsert your driver disk and press OK to continue  insert the driver  diskette into the floppy drive and click OK At the Devices dialog box  insert  the FastTrak driver diskette in the floppy drive and click OK     5  When the Devices dialog box appears  select Add Device     6  When the Installer asks  What kind of device would you like to add   select  SCSI     7  Scroll down to the Promise FastTrak S150 SX4 ATA RAID Controller and  click OK     8  When the Installer displays Promise FastTrak S150 SX4 ATA RAID  Controller has been found  click Done     9  Continue with the installation normally     Note  Check the readme file  included with the downloaded driver files  for  instructions on installing the RAID Console     Install Driver in an Existing System  1  Insert FastTrak Driver Diskette into the floppy drive   2  Log in as root   3  Type Run mount  r  dev fd0  mnt floppy   4  Run cd  mnt floppy  sh   install     5  When the  nstaller asks  You are installing a driver on an existing OS  Is it true   y n    type Y and press Enter     6  Run cd  umount  mnt floppy   7  Remove the FastTrak Driver Diskette and type reboot to restart the system     Note  Check the readme file  included with the downloaded driver files  for  instructions on installing the RAID Console        37    FastTrak
64. tripe       Disk Drives    Figure 1  RAID 0 writes data to both drives at the same time    Stripe Size     A value can be set from 16KB to 256KB sector size  The size can  directly affect performance  In the FastBuild BIOS  the default is 64KB        43    FastTrak SX4030  SX4060  S150 SX4 M User Manual       RAID 1  Mirror     Writes duplicate data on to a pair of drives while reads are performed in parallel   RAID 1 is fault tolerant because each drive of a mirrored pair is installed on  separate controller channels  If one of the mirrored drives suffers a mechanical  failure  for example  spindle failure  or does not respond  the remaining drive will  continue to function  This is called Fault Tolerance  If one drive has a physical  sector error  the mirrored drive will continue to function     On the next reboot  the FastBuild Utility will display an error in the array and  recommend replacing the failed drive  Users may choose to continue using their  PC  however Promise recommends replacing the failed drive as soon as  possible  Due to redundancy  the drive capacity of the array is half the total drive  capacity  For example  two 100 GB drives that have a combined capacity of 200  GB would have 100 GB of usable storage  With drives of different capacities   there may be unused capacity on the larger drive     Data Mirror    p        Disk Drives    Figure 2  RAID 1 copies the data from one drive to the other     Spare Drive     Under a RAID 1 setup  an extra hot spare dr
65. vice     Drive Related Errors  Critical Array Status Error Reported during Boot    If a critical status error message appears on the FastTrak BIOS startup  screen for a mirrored array  see below   there is a drive in the array that has  failed or is not responding  The FastTrak controller will identify the failed  drive by channel number  The mirrored array has lost its fault tolerance  but  will still perform normal drive reads and writes        50    Chapter 6  Troubleshooting  amp  Tips       Powering the system off and on once to reset the drive  Also confirm that  cables are properly attached and the drive is receiving power  If the drive still  appears to have failed  refer to the Rebuilding an Array option in the Promise  Array Management  PAM  utility as detailed in the PAM User Manual     Drive cannot be formed into an array    Drives must support Serial ATA and be free of media defects to be added  into an array  Promise recommends using new identical drives for each  array  Re secure data and power cabling while checking for proper  alignment  Typically  Pin 1 of the drive is closest to the power connector     System CMOS displays C  or D  drive failure during Startup    Do not reference C  or D  in the Motherboard Standard CMOS for drives  attached to the FastTrak controller  Only enter drive information in the  Motherboard CMOS for drives attached to the onboard IDE controller     FDISK reports a much lower drive capacity if a single physical drive or a  striped 
66. wapping    Each FastTrak S150 SX4 M can support up to four Serial ATA disk drives while  each FastTrak SX4030 and SX4060 can support up to four  Parallel  ATA disk  drives  With either Controller card the drives configured as RAID levels 1  0 1  or  5  Attached drives can be hot swapped when used with the optional Promise  SuperSwap drive enclosures        Chapter 1  Introduction       Promise Array Management Utility  PAM     The Promise Array Management  PAM  utility offers local and remote  management and monitoring of all FastTrak arrays that exist anywhere on a  network  Windows based GUI provides email notification of all major events   alarms  memory cache management  logging for NT 2000 servers  array  maintenance  rebuild  and access to all components in array  server  controller   data channels  individual drives  and enclosure   For information on using PAM   refer to the PAM User Manual  which is included on the CD        FastTrak SX4030  SX4060  S150 SX4 M User Manual          Chapter 2  Installation    Package lists  below  Installing the FastTrak card  page 7  Installing the Disk Drives  page 8    S150 SX4 M    When you receive the FastTrak S150 SX4 M card  the package should contain  the items listed below     FastTrak 8150 SX4 M RAID Controller Card   64 MB SDRAM DIMM Memory Card   Quick Start Guide   FastTrak driver diskette   Four internal 4 wire Serial ATA hard drive data cables  Two Y power splitter cables    CD with Drivers  Promise Array Management  PAM
67. ws 2003 Promise FastTrak S150 SX4 SX4000 Series    Note  If you need to specify any additional devices to be installed  do so at  this time  Once all devices are specified  continue to the next step     From the Windows Setup screen  press the Enter  Setup will now load all  device files and then continue the Windows installation     Note  Check the readme file  included with the downloaded driver files  for  instructions on installing the RAID Console        30    Chapter 4  Installing Software Drivers       Install Driver in an Existing System    Important       If you plan to move the boot drive containing the existing Windows  Server 2003 operating system to the FastTrak card  you MUST  load the FastTrak driver to the boot drive while it is still attached to  your existing hard drive controller     Do not attach the boot drive to the FastTrak card before  completing this step        After installing the FastTrak card and rebooting your system  Windows setup will  show a Found New Hardware dialog box     1     13   14     Insert the Promise FastTrak Driver diskette in the A  drive     When the New Hardware Wizard appears  select  nstall from a list or specific  location  advanced  and click Next     Under Please choose your search and installation options  select Don t  search    will choose the driver to install and click Next     Under Select the device driver you want to install  click Have Disk     Under Install from Disk  type A  wnet wnet and click OK    Under Select
68. y to  back up or otherwise save important data before installing any product and  continue to back up your important data regularly        62    Chapter 7  Support       No other document  statement or representation may be relied on to vary the  terms of this limited warranty     Promise   s sole responsibility with respect to any product is to do one of the  following     a  replace the product with a conforming unit of the same or superior  product     b  repair the product     Promise shall not be liable for the cost of procuring substitute goods  services   lost profits  unrealized savings  equipment damage  costs of recovering   reprogramming  or reproducing of programs or data stored in or used with the  products  or for any other general  special  consequential  indirect  incidental  or  punitive damages  whether in contract  tort  or otherwise  notwithstanding the  failure of the essential purpose of the foregoing remedy and regardless of  whether Promise has been advised of the possibility of such damages  Promise  is not an insurer  If you desire insurance against such damage  you must obtain  insurance from another party     Some states do not allow the exclusion or limitation of incidental or consequential  damages for consumer products  so the above limitation may not apply to you     This warranty gives specific legal rights  and you may also have other rights that  vary from state to state  This limited warranty is governed by the State of  California     Your
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Samsung SPF-85V Bruksanvisning  AGFA SNAPSCAN E52 User's Manual  BISCABUS Horaires été 2015  CX-G2400 基本操作ガイド  User Manual-SNF-7010  EVB-LAN9730-MII Evaluation Board User Manual - SMSC  OmniMount OMN-ECSB  mise en garde  Acer TravelMate TM5744-373G32Mikk : Free Download, Borrow, and Streaming : Internet Archive    Copyright © All rights reserved. 