User`s Manual 3D Mini Controller
Contents
1. AF Aa S amp S amp m oer Ya Nol ey No Dome 1 Dome 2 Dome 3 Dome 4 7 A Aa G amp Keyboard Nod Noy a Noy Dome 5 Dome 6 Dome 7 Dome 8
2. Press PREV to back Dome setup gt Set dome pattern 1 Press the digit and ENTER to select the pattern number 2 Sub menu for pattern setup 3 start the selected pattern 1 Pattern num _ 2 Set pattern 3 Run pattern Dome setup gt Set dome pattern gt Set pattern Press 1 to start the pattern recording The dome will now memorize your PTZ operation When finished press 0 to stop the recording Press PREV to exit the menu Press 1 to start Press 0 to stop Press PREV to back Dome setup gt Set dome tour 1 Press the digit and ENTER to select the tour number 2 Add defined preset position to the tour 3 start the selected tour 1 Tournum _ 2 Insert preset 3 Run tour Dome setup gt Set dome tour gt Insert preset 1 Preset num _ select the defined preset position 1 80 2 Speed PTZ moving speed to this preset 1 8 fastest 3 Dwell Stop time on this preset Max 60 seconds 1 Preset num _ 2 Speed 3 Dwell Use the digit keys to change the value on every option and press ENTER to complete the insert action The LCD will show SUCCESS to confirm the preset and returns to upper menu level Protocol select 1 Matrix Matrix Mode 1 Matrix 2 Dome Setup Dome Protocol 2 Dome Protocol select gt Matix 1 Pelco Matrix Currently only pelco protocol is supported Protocol gt Dome 1 Factory protocol 2 Pelco P protocol 3 Pelco D protocol 4 B02
3. B01 Initial Screen Baudrate 9600bps Cam ID Current camera ID Mon ID Current monitor ID indicates the ouput setting on matrix Protocol Telemetric protocol setting Baudrate Baud Rate setting The LCD back light will be turned off automatically after 15 seconds of idle time PT Operation with Joystick Move the joystick up down left and right to perform pan or tilt operation Depends on the angle of stick the keyboard changes the speed of PT movement On performing the PT action the LCD will show the current movement with arrow signs Zoom operation The keyboard provides camera function keys with following function Wide Tele Zoom out and zoom in Far Near Manual focus control Open Close Manual Iris control PTZ related functions With the keyboard you can activate or setup the integrated function of connected camera device For the supported functions please refer to camera s manual for further details Change currently selected camera Press n CAM n ID of the camera Set define a Preset position Move the PTZ to the desired position and press SET n PRESET To store the current position as a preset n Recall activate Preset position To recall the memorized preset position press n PRESET N The number of preset to be recalled Set Tour function B01 You need to enter the keyboard s menu to setup the tour Pleare refer to the later chapter for setup Recall activa
4. DO NOT CONNECT THE RJ 45 PORT TO ANY COMPUTER NETWORK INTERFACE as this may cause serious damage to the keyboard in the matrix mode Press ENTER to exit Quick Reference N CAM Select the connected device TELE Zoom I n WIDE Zoom Out FAR Manual focus far NEAR Manual focus near CLOSE Manual iris close OPEN Manual iris open SET N PRESET Store current PTZ position as preset N PRESET Recall stored preset position SET 1 SCAN Define current position as the left limit for scan SET 2 SCAN define current position as the right limit for scan 1 SCAN Start the scan SET N J PATTERN Start pattern recording SET O PATTERN Stop the pattern recording and store N J PATTERN Start recorded pattern N TOUR Start the defined tour Connection sample Star Connection with RS Distributor Max 32 devices Keyboard and camera can be connected to a __ RS 485 chain E g with 1 Activated keyboard you can max RS 485 on every dam Connect 31 Speed S Distributor j N Domes a Termination on RS 485 chain Keyboard ae Termination Termination On On Termination Termination Off Off Multiple device connection For a multiple connection you can attach max 4 keyboards to the network Make sure that every keyboard has an unique ID
5. 3D Mini Controller 3 Axis Compact Keyboard Controller User s Manual TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE DO NOT INSERT ANY METALLIC OBJECTS THROUGH THE VENTILATION GRILLS OR OTHER OPENINGS ON THE EQUIPMENT This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL FCC COMPLIANCE STATEMENT FCC INFORMATION THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE LIMITS FOR A CLASS A DIGITAL DEVICE PURSUANT TO PART 15 OF THE FCC RULES THESE LIMITS ARE DESIGHEND TO PROVIDE REASONABLE PROTECTION AGAINST HAMRFUL INTERFERENCE WHEN THE EQUIPMENT IS OPERATED IN A COMMERCIAL ENVIRONMENT THIS EQUIPMENT GENERATES USES AND CAN RADIATE RADIO FREQUENCY ENGERGY AND IF NOT INSTALLED AND USED INACCORDANCE WITH THE INSTRUCTION MANUAL MAY CAUSE HARMFUL INTERFERENCE TO RADIO COMMUNICATIONS OPERATION OF THIS EQUIPMENT IN A RESIDENTIAL AREA IS LIKELY TO CAUSE HARMFUL INTERFERENCE IN WHICH CASE THE USER WILL BE REQUIRED TO CORRECT THE INTERFERENCE AT HIS OWN EXPENSE CAUTION CHANGES
6. Change target monitor Press n MON to change the selected device in the matrix Keyboard Menu Keyboard setup 1 Set KB Parameter 2 About keyboard Keyboard setup Dome setup gt About keyboard Version 1 00 KB ID 008 Protocol select Exit menu Protocol Factory Baudrate 2400 1 Set dome preset 2 Set dome scan 3 Set dome pattern Set KB Parameter 1 2 3 Set dome preset 1 2 Show preset 3 Clear preset SetKBID Input KB ID Joy_calibrate Set baudrate 2400 bps 4800 bps Set KB ID Set baudrate 9600 bps 19200 bps Joy_calibrate 1 Joy is free then Press ENTER Preset num Save preset gt Press prev to back Set eft limi Set right imi 1 Set left limit 2 Set right limit Run scan Press enter sure Press enter sure Success Press prev to back Press prev to back Set dome pattern Set pattern Run pattern ai 2 Set pattern Pattern num Success Press 1 to start Press Oto stop Press prev to back Run pattern Set dome tour Insert preset 1 Tour num 2 Insert preset CamID 001 MonID 001 Protocol Pelco P Baudrate 9600 1 Matrix 2 Dome Enter the keyboard menu To enter the keyboard s setup menu keep the SET Key pressed for 2 seconds To navigate through the menu items use the joystick with up and down to move between the items U
7. OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE COULD VOID THE USERS S AUTHORITY TO OPERATE THE EQUIPMENT CE COMPLIANCE STATEMENT WARNING THIS IS A CLASS A PRODUCT IN A DOMESTIC ENVIRONMENT THIS PRODUCT MAY CAUSE RADIO INTERFERENCE IN WHICH CASE THE USER MAY BE REQUIRED TO TAKE ADEQUATE MEASURES This Symbol indicates that this product should not be treated as household waste When discarding this product it must be sent to appropriate facilities for recycling or recovery By separating this product from other household waste you are helping to reduce the volume of waste incinerators and the natural resource will be conserved Before Starting Refer all work related to the installaion of this product to qualified service personnel or system installers Do not attemp to disassemble the keyboard To prevent electric shock do not remove screws or cover There are no user serviceable parts inside Contact qualified service personnel for maintenance Handle the keyboard with care Donotstrike or shake as this may damage the keyboard It should be protected against extreme pressure vibration and humidity during transportation storage and operation Damages caused by improper transportation avoid the warranty Do not operate the apliance beyond its specified temperature humidity or power source ratings Do not use the keyboard inan extreme environment where high temperature or high humidity exis
8. nce can be up to 1000 meter depends on cable and environmental condition RS 422 T T R R Rs422 Inteface for telemetric control up to 1200 meters RJ 45 Control interface forr matrix device e g Pelco Cm6700 CM6800 DC Power Input Power supply for the keyboard Voltage range is 9V to 12V in DC or AC without polarity auto sensing When connecedt to the Matrix the keyboard can be powered thourgh the RJ 45 Interface Check list Please make sure that the following chapters are set correctly Cable Connection Make sure that the RS485 422 cable are connected correctly to the camera devices fora XO m D xo EEY RX Ny RX z RS 485 RS 422 Baud Rate The keyboard and the camera devices must have the same baud rate setting in order to establish the data exchange Available settings are 2400 4800 and 9600 Bps For settings on the camera device please refer to camera s manual for further details Protocol Make sure that the keyboard and camera devices are set with the same protocol Currently Pelco and B01 B02 are supported by the keyboard please refer to camera s manual for details Camera ID Make sure that every connected PTZ device is assigned with an unique ID For settings of your keyboard Please refer to later chapters for details LCD Display 3 Axis Joystick Function Keys Digit Keys Camera Function keys Cam ID 001 Mon ID 001 Protocol
9. ress PREV to return to upper level 2400 bps 4800 bps 9600 bps 19200 bps Keyboard Setup gt Set KB Parameter gt Joy_calibrate Release the joystick and press ENTER to confirm the calibrate of zero point Press PREV to return to upper level Joystick is free then press Enter Keyboard Setup gt About keyboard Information about current keyboard Version 1 00 setting Press PREV to return KB ID 001 Protocol B01 Baudrate 9600 bps Dome setup Configure and setup the PTZ related 1 Set dome preset functions such as preset pattern Etc 2 Set dome scan 3 Set dome pattern 4 Set dome tour Dome setup gt Set dome preset Save recall and clear the preset points 1 Save preset p P 2 Show preset 3 Clear preset Dome setup gt Set dome preset gt Save show or clear preset Enter the preset number with the digit key For saving preset move the joystick and press ENTER To show or clear the preset enter the preset number and press ENTER or press PREV to exit Preset num Press PREV to back Dome setup gt set dome scan Setup the 2 Points scan select 1 And 2 To define the left and right limit Select option nr 3 To run the scan 1 Set left limit 2 Set right limit 3 Run Scan Dome setup gt set dome scan gt set left right limit Move the Joystick to the desired position Press ENTER sure and press ENTER for confirmation
10. se right to enter the item or confirm changes Use left to leave the item or discard changes Main Menu In main menu you can select the items by pressing the digit key or use joystick to navigate through the items For returning to upper menu level press PREV key Use the ENTER 1 Keyboard setup 2 Dome setup 3 Protocol select 4 Exit menu key to confirm the changes The display will show SUCCESS when changes are accepted Keyboard Setup Initial setup for the keyboard such as keyboard ID and baud rate Press digit key to enter 1 Set KB Parameter 2 About keyboard Keyboard Setup gt Set KB Parameter Setup keyboards ID Baud rate and calibrates the joystick Joystick up down to select item ENTER to enter the sub menu PREV return to upper level 1 Set KB ID 2 Set baudrate 3 Joy_calibrate Keyboard Setup gt Set KB Parameter gt Set KB ID Use the digit keys to enter the ID and press ENTER to confirm LCD will show SUCCESS when accepted or ERROR if the ID input exceeds the range Input KB ID 1 64 Protocol select 1 Pelco matrix Dome Pelco P Pelco D 1 Preset num 2 Speed Dwell Success Pelco matrix Success Factory Success B02 Keyboard Setup gt Set KB Parameter gt set baudrate Available baud rate Move joystick up or down to select the setting and press ENTER to confirm P
11. te Tour To start the tour press n TOUR N Number of the stored tour Setup 2 Points scan Scan between 2 pre defined points To define the points move to the left end and press SET 1 SCAN and move to the right end and press SET 2 SCAN to store the position For changing the scan speed you need to enter the PTZ s OSD menu Please refer to the users manual for details Start 2 Points Scan Press 1 SCAN to start the scan procedure Start Stop Pattern recording The pattern function records user s PTZ movement and can be recalled when need Depends on the camera device the recording time and supported number of pattern tracks might differ To start the recording procedure press SET n PATTERN n the number of pattern track To stop the pattern recording press SET 0 PATTERN Activate recorded Pattern To activate the recorded pattern press N PATTERN Matrix related functions Switching the input channel Press PREV switch to previous channel Press NEXT switch to next channel Auto switching sequence Press PREV for 2 sec Sequence in rev order Press NEXT for 2 sec Sequence to next channel Press STOP to stop the sequencel Open matrix configuration menu Press SHIFT SET to enter the menu and show on main monitor For the menu details please refer to the users manual of the matrix Confirm changes Press ENTER after every changes in the menu
12. ts Use it within 5 C to 40 C 23 F to 140 F and a humidity below 90 The input power source is 12V DC and requires at least 500mA Read this user s manual carefully before operation Make sure that local electric safty standards are followed when using or installing the keyboard Do not install this Product in a flammable and explosive environment Before installation and mentainence make sure that the keyboard is disconnected from the power source Do not install or operate the keyboard near any high voltage devices or high voltage cable The safety distance should remain atleast 50 m This product should be operated indoor only Technical specifications are subjects to change without prior notice This Manual may contain printing or clerical errors All trademarks mentioned belong to their respective owners Unpacking D KART Eentroller P USER S MANUAL a AC DC Power Supply optional 1x User Manual 1 X Controller Connection RS485 RS422 RJ45 DC ACIV 12V A B T T R R i ea Power Input RS 422 Interface Matrix Interface Matrix ali RS 485 DO NOT CONNECT THE RJ 45 PORT up to 32 Devices TO ANY COMPUTER NETWORK INTERFACE as this may cause serious damage to the keyboard RS 485 A B For connection to PTZ Speed Domes or other device which support telemetric controling with RS 485 interface The max Dista